1. Passive House School in Bremen Passive House in Hamburg Passive House School in Klaus/Austria
Perspectives for the future -
Passive House Technology
Univ.-Prof. Dr. Wolfgang Feist,
University of Innsbruck, Austria and
Passive House Institute, D-64283 Darmstadt
Germany
www.passivehouse.com
4. fresh air exhaust air ventilation with
thermal heat recovery
insulation
filter
extract
air supply air
tripple
pane
and
insulated
windows
5. 200 1400
Gesamtkosten Kapital und Energie [€/m²] in Greece ( Χαλκίδα ) Außenwand mit 1300
180
WDVS Mineralwolle 1200
160 bei Neubau
1100
kumulierter Primärenergie-
ökonomisch
optimaler Bereich
140 7 bis 21 cm 1000
einsatz kWh/m²
900
120
800
U=0,37 U=0,15
100 W/(m²K) W/(m²K)
700
U=0,24 600
80
W/(m²K)
500
"Optimum" Mineralwolle 150 kWh/m³
60 400
ökologisch optimaler Bereich 20
40 bis 130 cm 300
200
20
100
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60
Dicke der Dämmung [cm]
Randbedigungen 2012 35 kKh 2,5% Realzins, 10 Cent/kWh, 30 a Dämmkosten 1.15 €/cm
6. Sustainable Solutions:
energy + glazings
advanteges: not only
Triple low-e energy savings, but
• higher surface temp.
double low-e • better comfort
• no condensation
• no drafts
2-pane
• better preservation of
the structure
single
7. Different Window Sizes:
small -> Heating big -> Cooling
40
Heizwärme und Kühlkälte kWh/m²a
Heizwärme in Greece ( Χαλκίδα )
35
Kühlkälte
30
25
20
15
10
5
0
0% 20% 40% 60% 80% 100%
Fenstergröße
10. Die Zeit ist weltweit reif für’s Passivhaus
Das internationale Passivhaus-
Netzwerk
The International Network for
Passive House knowledge
http://www.passivehouse-international.org
11. passipedia
Teil 1: Allgemeine Information für die breite Öffentlichkeit
Teil 2: Informationen und Tools für die Mitglieder
12. englisch
Congress Center
Frankfurt am Main
19 - 20 April 2013
with exhibition and
framework programme
(17. – 21. April 2013)
www.passivehouseconference.org
And this is not utopic and it is not just theory! It is existing technology, well approved and affordable. This photography shows the very first passive house which has been built in 1990 and is occupied since October 1991. It is a four units row house – all four dwellings being passive houses. The house is a typical German masonry construction with thick insulation on the outside, specially developed windows and heat recovery systems in each dwelling. The architect Prof. Bott/Ridder and Westermeyer have done a good job to avoid thermal bridging. The house was built by private owners. There was a more than five years scientific monitoring programme (financed by the Hessian government) to gain results out of this building and to learn about the behavior of energy efficient construction. You still see the weather station on top of the roof.
And this is not utopic and it is not just theory! It is existing technology, well approved and affordable. This photography shows the very first passive house which has been built in 1990 and is occupied since October 1991. It is a four units row house – all four dwellings being passive houses. The house is a typical German masonry construction with thick insulation on the outside, specially developed windows and heat recovery systems in each dwelling. The architect Prof. Bott/Ridder and Westermeyer have done a good job to avoid thermal bridging. The house was built by private owners. There was a more than five years scientific monitoring programme (financed by the Hessian government) to gain results out of this building and to learn about the behavior of energy efficient construction. You still see the weather station on top of the roof.
Left hand side: ordinary window. There is a Net Energy loss . Right hand side: Super-window, Net Energy gain. Produced by European small enterprises.
The buildings shown so far have been very well insulated as part of their retrofit. The highest remaining heat loss after that is ventilation – but you can not reduce ventilation, in the contrary, fresh air is important for the health of the persons living in the buildings. But there is a solution: Heat can be recovered from the extract air before it is exhausted. Modern European air-to-air heat exchangers have recovery rates between 80 and 90%. Also with this technology Europe is world leader.
Die iPHA (internationale Passivhaus Vereinigung) … hat inzwischen Mitglieder aus mehr als 40 Ländern. Überall auf der Welt entstehen nationale Passivhaus-Initiativen: Passivhäuser können mit dem weltweit frei verfügbaren Know-How an jedem Bauplatz auf dem Globus mit regional verfügbaren Materialien gebaut werden – und natürlich sieht ein Passivhaus in Sanghai ganz anders aus als ein solches in St. Petersburg: Die funktionalen Kriterien bleiben exakt die gleichen, ebenso wie die Methoden (die Physik ist überall gleich). Durch unterschiedliche klimatische und kulturelle Randbedingungen enstehen aber Lösungen mit verscheidenen Materialien und Konstruktionen. (weiterführend: http://www.passivehouse-international.org/)
Know-How ist der Schlüssel Die Passipedia hält die wichtigsten Informationen zum Passivhaus bereit: Wie ist der Standard definiert und warum gerade so? Wie plane ich, wie baue ich in Passivhaus? Welche Komponenten brauche ich und was kosten die ungefähr? Wo gibt es Erfahrungen mit dem Bau und mit dem Wohnen im Passivhaus? (Z.B. darf man im Passivhaus die Fenster öffnen?) Alle diese Informationen finden Bauherren im allgemein zugänglichen ersten Teil der Passipedia. Für Fachleute gibt es zusätzliche Informationen – und auch die frei für die Mitglieder einer zur iPHA affiliierten Organisation: Wie führe ich einen Drucktest im Passivhaus durch? Welche Materialien und Konstruktionen eignen sich für luftdichte Anschlüsse? Welche Besonderheiten gibt es bei Sonderbauaufgaben (z.B. Bürogebäude, Schulen,…) Wie handhabe ich das PHPP bei besonderen Aufgaben.