Flow Solutions Division
Mechanical Seal Piping Plans
Single Seals plans 01, 02, 11, 13, 14, 21, 23, 31, 32, 41
Dual Seals plans 52, 53A, 53B, 53C, 54
Quench Seals plan 62
Gas Seals plans 72, 74, 75, 76
Flowserve’s Flow Solutions Division recognizes one of the most effective ways to
achieve long, uninterrupted mechanical seal life is to create a healthy
environment around the seal faces. Piping plans help keep mechanical seals
running cool and clean, promote safe handling of dangerous fluids, and extend
the operational availability of rotating equipment. This reference book is intended
to provide a concise summary of the most essential piping plans used
successfully in today’s process plants.
Each plan shows all the standard and optional auxiliary components referenced
in API Standard 682 2nd edition although not all components are needed in all
applications. Consult your local Flowserve Flow Solutions Sales Engineer to
identify the right solution that satisfies your application requirements.
Mechanical Seal Piping Plans
printed in USA © 2003 Flowserve Corporation
For each piping plan identified in API Standard 682 2nd edition and recommended by
Flowserve, each page set of this book shows:
Seal End View Piping Plan Layout What, Why, and Where
Pump Cross-section Mechanical Seal
outlet
inlet
pressure source,
normally open
pressure gage
pressure switch
level switch (high)
level switch (low)
cooling in
cooling coils
drain,
normally closed
level gage
cooling out
reservoir
liquid fill,
normally closed
Flow Solutions Division
What
• Pressurized barrier fluid circulation through reservoir.
• Fluid is circulated by a pumping ring in the dual seal assembly.
Why
• Isolate process fluid.
• Zero process emissions.
Where
• Used with dual pressurized seals (Arrangement 3 or “double”).
• High vapor pressure fluids, light hydrocarbons.
• Hazardous/toxic fluids.
• Heat transfer fluids.
• Dirty/abrasive or polymerizing fluids.
• Mixers/agitators and vacuum service.
Presventative Maintenance - Reference Appendix A
• Piping loop must self-vent to reservoir locate at highest elevation.
• Reservoir must be pressurized at all times - typically gas charge up to 200 psi (14bar).
• Barrier fluid must be compatible with process.
• Reservoir level gage indicates both inboard and outboard seal leakage.
Plan53A
Plan53A
seal
end view
Preventative Maintenance
• Viewed from drive end
• Shows preferred gland
connection orientation
• Illustrated schematic
of auxiliary components
• Describes piping plans,
their purpose, and
typical applications
• Simplified centrifugal
pump shown for all
plans
• Shows typical seal
arrangements
• Provides general tips to
improve reliability and for
troubleshooting
Plan01
seal
end view
internal porting
Flow Solutions Division
Plan01
What
Internal seal chamber flush from pump discharge.
Operates similar to Plan 11.
Why
Seal chamber heat removal.
Seal chamber venting on horizontal pumps.
Reduce risk of freezing/polymerizing fluid in exposed Plan 11 piping.
Where
Custom seal chamber, most likely an ANSI/ASME pump.
Clean, moderate temperature fluids.
Used with single seals, rarely with dual seals.
Preventative Maintenance
Flush typically can not be directed over seal faces and seal heat removal is limited.
Calculate flush flow rate based on head loss through internal porting.
Plan02
seal
end view
open throat seal chamber shown
Flow Solutions Division
Plan02
What
Dead-ended seal chamber with no flush.
Why
Simplicity - no environmental controls.
Where
Large bore/open throat seal chambers in moderate temperature services.
Cooling jacket seal chambers in high temperature services.
Clean fluids.
Top-entry mixers/agitators with dry seals.
Preventative Maintenance
Process must have adequate boiling point margin to avoid vaporization.
Cooling fluid in seal chamber jacket may be needed at all times in hot services.
Often used in combination with steam quench, Plan 62.
Plan11
seal
end view
inlet
orifice
Flow Solutions Division
Plan11
What
Seal flush from pump discharge through orifice.
Default single seal flush plan.
Why
Seal chamber heat removal.
Seal chamber venting on horizontal pumps.
Increase seal chamber pressure and fluid vapor margin.
Where
General applications with clean fluids.
Clean, non-polymerizing fluids.
Preventative Maintenance
Use an orifice with a minimum 0.125" (3 mm) diameter.
Calculate flow rates to size orifice for adequate seal chamber flow.
Increase boiling point margin with proper orifice and throat bushing sizing.
Flush should be directed over seal faces with piping at 12 O’clock position.
Typical failure mode is a clogged orifice - check temperatures at pipe ends.
Plan13
seal
end view
outlet
orifice
Flow Solutions Division
Plan13
What
Recirculation from seal chamber to pump suction through orifice.
Standard flush plan on vertical pumps.
Why
Continuous seal chamber venting on vertical pumps.
Seal chamber heat removal.
Where
Vertical pumps.
Seal chamber pressure is greater than suction pressure.
Moderate temperature fluids with moderate solids.
Non-polymerizing fluids.
Preventative Maintenance
Vent piping loop prior to starting vertical pumps.
Use an orifice with a minimum 0.125" (3 mm) diameter.
Calculate flow rates to size orifice for adequate seal chamber flow.
Reduce seal chamber pressure with proper orifice and throat bushing sizing.
Typical failure mode is a clogged orifice - check temperatures at pipe ends.
Plan14
seal
end view
orifices
outlet
inlet
Flow Solutions Division
Plan14
What
Seal flush from pump discharge and recirculation to pump suction with orifices.
Combination of Plan 11 and Plan 13.
Why
Continuous seal chamber venting on vertical pumps.
Seal chamber heat removal.
Increase seal chamber pressure and fluid vapor margin.
Where
Vertical pumps.
Clean, non-polymerizing fluids at moderate temperatures.
Preventative Maintenance
Use an orifice with a minimum 0.125" (3 mm) diameter.
Calculate flow rates to size orifice for adequate seal chamber flow.
Increase boiling point margin with proper orifice and throat bushing sizing.
Flush should be directed over seal faces.
Vent piping loop prior to starting vertical pumps.
Typical failure mode is a clogged orifice - check temperatures at pipe ends.
Plan21
seal
end view
drain,
normally
closed
inlet
vents,
normally closed
cooling in
cooler
cooling out
orifice
cooling coils
Flow Solutions Division
Plan21
What
Seal flush from pump discharge through orifice and cooler.
Cooler in Plan 11 flush increases heat removal.
Why
Seal cooling.
Reduce fluid temperature to increase fluid vapor margin.
Reduce coking.
Where
High temperature service, typically less than 350° F (177° C).
Hot water over 180° F (80° C).
Clean, non-polymerizing fluids.
Preventative Maintenance
Seal cooler and piping must have air vents at highest elevation - vent before starting.
When using 682 Seal Cooler, pipe with series flow to maximize heat transfer.
Use an orifice with a minimum 1/8" (3 mm) diameter.
Calculate flow rates to size orifice for adequate seal chamber flow.
Increase boiling point margin with proper orifice and throat bushing sizing.
Regularly monitor device inlet and outlet temperatures for signs of clogging or fouling.
Plan23
seal
end view
outlet
inlet
drain,
normally
closed
vent,
normally closed
cooling in
cooler
cooling out
cooling coils
Flow Solutions Division
Plan23
What
Seal flush from internal pumping device through cooler.
Standard flush plan in hot water services.
Why
Efficient seal cooling with low cooler duty.
Increase fluid vapor margin.
Improve water lubricity.
Where
High temperature service, hot hydrocarbons.
Boiler feed water and hot water over 180° F (80° C).
Clean, non-polymerizing fluids.
Preventative Maintenance - Reference Appendix A
Seal cooler and piping must have air vents at highest elevation - vent before starting.
When using 682 Seal Cooler, pipe with parallel flow to minimize head loss.
Seal chamber requires close clearance throat bushing to isolate process fluid.
Tangential seal gland taps should enter at bottom and exit at top.
Regularly monitor cooler inlet and outlet temperatures for signs of plugging or fouling.
Process fluids with iron should flow through magnetic separator before cooler.
Plan31
seal
end view
inlet
cyclone separator
Flow Solutions Division
Plan31
What
Seal flush from pump discharge through cyclone separator.
Centrifuged solids are returned to pump suction.
Why
Seal chamber heat removal.
Solids removal from flush and seal chamber.
Where
Dirty or contaminated fluids, water with sand or pipe slag.
Non-polymerizing fluids.
Preventative Maintenance
Cyclone separator works best on solids with a specific gravity twice the process fluid.
Seal chamber pressure must be nearly equal to suction pressure for proper flows.
Piping should not include an orifice and is not expected to vent the seal chamber.
Typical failure mode is clogged separator or pipes - check temperatures at pipe ends.
Plan32
seal
end view
inlet
flow
meter
isolation
valvepressure
gage
check
valve
from clean
source,
normally
open
strainer
Flow Solutions Division
Plan32
What
Seal flush from an external clean source.
Why
Seal chamber heat removal.
Process and solids removal from seal chamber.
Increase seal chamber pressure and fluid vapor margin.
Where
Dirty or contaminated fluids, paper pulp.
High temperature service.
Polymerizing and/or oxidizing fluids.
Preventative Maintenance
Use throat bushing sized to hold pressure or maintain flow velocity.
To restrict dirty process fluid, regulate injection flow rate.
To increase fluid vapor margin, regulate injection pressure.
Injection fluid must be compatible with process fluid.
Regularly monitor control system for closed valves or signs of plugging.
Plan41
seal
end view
inlet
drain,
normally
closed
vents,
normally closed
cooling in
cooler
cooling out
cooling coils
cyclone
separator
Flow Solutions Division
Plan41
What
Seal flush from pump discharge through cyclone separator and cooler.
Combination of Plan 21 and Plan 31.
Why
Seal cooling.
Solids removal from flush and seal chamber.
Where
High temperature service, typically less than 350° F (177° C).
Dirty or contaminated fluids, water with sand or pipe slag.
Non-polymerizing fluids.
Preventative Maintenance
Seal cooler and piping must have air vents at highest elevation - vent before starting.
When using 682 Seal Cooler, pipe with series flow to maximize heat transfer.
Cyclone separator works best on solids with a specific gravity twice the process fluid.
Seal chamber pressure must be nearly equal to suction pressure for proper flows.
Typical failure mode is clogged separator or pipes - check temperatures at pipe ends.
seal
end view
Plan52
outlet
inlet
drain,
normally
closed
vent,
normally open
cooling in
pressure gage
cooling out
cooling coils
reservoir
pressure switch
level gage
level switch (high)
level switch (low)
liquid fill,
normally closed
orifice
Flow Solutions Division
Plan52
What
Unpressurized buffer fluid circulation through reservoir.
Fluid is circulated by a pumping ring in the dual seal assembly.
Why
Outboard seal acts as a safety backup to the primary seal.
Zero to very low process emissions.
No process contamination is allowed.
Where
Used with dual unpressurized seals (“tandem”).
High vapor pressure fluids, light hydrocarbons.
Hazardous/toxic fluids.
Heat transfer fluids.
Preventative Maintenance - Reference Appendix B
Piping loop must self-vent to vapor recovery/flare system near atmospheric pressure.
Process vapor pressure is generally greater than reservoir pressure.
Buffer fluid must be compatible with process leakage.
Primary seal leakage is indicated by increased vent pressure.
Reservoir level gage indicates outboard seal leakage.
Plan53A
seal
end view
outlet
inlet
pressure source,
normally open
pressure gage
pressure switch
level switch (high)
level switch (low)
cooling coils
cooling in
drain,
normally
closed
cooling out
reservoir
liquid fill,
normally closed
level gage
Flow Solutions Division
Plan53A
What
Pressurized barrier fluid circulation through reservoir.
Fluid is circulated by a pumping ring in the dual seal assembly.
Why
Isolate process fluid.
Zero process emissions.
Where
Used with dual pressurized seals (“double”).
High vapor pressure fluids, light hydrocarbons.
Hazardous/toxic fluids.
Heat transfer fluids.
Dirty/abrasive or polymerizing fluids.
Mixers/agitators and vacuum service.
Preventative Maintenance - Reference Appendix B
Piping loop must self-vent to reservoir located at highest elevation.
Pressurize reservoir at all times, maximum gas charge 150 - 200 psi (10 - 14 bar).
Barrier fluid must be compatible with process.
Reservoir level gage indicates both inboard and outboard seal leakage.
Plan53B
seal
end view
outlet
inlet
pressure source,
normally closed
pressure
gage
pressure switch
drain,
normally
closed
liquid fill,
normally closed
vent,
normally closed
bladder
accumulator
finned
pipe
Flow Solutions Division
Plan53B
What
Pressurized barrier fluid circulation with bladder accumulator.
Fluid is circulated by a pumping ring in the dual seal assembly.
Why
Isolate process fluid.
Zero process emissions.
Higher pressure than Plan 53A.
Where
Used with dual pressurized seals (“double”).
High vapor pressure fluids, light hydrocarbons.
Hazardous/toxic fluids.
Heat transfer fluids.
Dirty/abrasive or polymerizing fluids.
Preventative Maintenance - Reference Appendix B
Piping loop must be fully vented before starting.
Accumulator must be pressurized at all times, usually by gas charge.
Barrier fluid must be compatible with process.
Regularly monitor barrier pressure - manually add barrier fluid when pressure decays.
Plan53C
outlet
inlet
seal
end view
vent,
normally closed
pressure gage
pressure switch
level switch (low)
cooling in
drain,
normally
closed
cooling out
liquid fill,
normally closed
level gage
cooling coils
Flow Solutions Division
Plan53C
What
Pressurized barrier fluid circulation with piston accumulator.
Fluid is circulated by a pumping ring in the dual seal assembly.
Why
Isolate process fluid.
Zero process emissions.
Higher pressure than Plan 53A.
Dynamic tracking of system pressure.
Where
Used with dual pressurized seals (“double”).
High vapor pressure fluids, light hydrocarbons.
Hazardous/toxic fluids.
Heat transfer fluids.
Preventative Maintenance - Reference Appendix B
Piping loop must be fully vented before starting.
Reference line must tolerate process contamination without plugging.
Barrier fluid must be compatible with process.
Reservoir level gage indicates both inboard and outboard seal leakage.
Plan54
seal
end view
outlet
inlet
from / to external
circulating system
Flow Solutions Division
Plan54
What
Pressurized barrier fluid circulation by external system.
Why
Isolate process fluid.
Zero process emissions.
Seal cannot induce circulation.
Where
Used with dual pressurized seals (“double”).
High vapor pressure fluids, light hydrocarbons.
Hazardous/toxic fluids.
Heat transfer fluids.
Dirty/abrasive or polymerizing fluids.
Mixers/agitators.
Preventative Maintenance
Piping loop must be fully vented before starting.
Circulating system must be pressurized and energized at all times.
Barrier fluid must be compatible with process.
Circulating system level gage indicates both inboard and outboard seal leakage.
Plan62
seal
end view
inlet
drain
pressure
gage
steam trap
(steam quench)
quench,
normally
open
drain,
normally
open
Flow Solutions Division
Plan62
What
External quench on atmospheric side of seal.
Quench fluids typically steam, nitrogen, or water.
Why
Prevent solids buildup on atmospheric side of seal.
Prevent icing.
Where
Used with single seals.
Oxidizing fluids or fluids that coke, hot hydrocarbons.
Crystallizing fluids or fluids that salt out.
Caustic.
Cold fluids less than 32° F (0° C).
Preventative Maintenance
Quench inlet should be on top of gland with outlet/drain on bottom.
Quench pressure should be limited to 3 psi (0.2 bar) or less.
Use throttle bushing on atmospheric side of seal to direct quench flow to seal drain.
Monitor regularly, checking for closed valves, blocked lines, and steam trap condition.
Plan72
seal
end view
vent
drain
inlet
1
3
2
C
D
A
B
E
F
H
G
1 - drain
2 - vent
3 - gas inlet, normally open
4 - filter drain, normally closed
4
A - filter
B - regulator
C - orifice
D - flow meter
E - flow switch
F - pressure switch
G - pressure gage
H - check valve
Flow Solutions Division
Plan72
What
Unpressurized buffer gas control system.
Containment seal support typically with nitrogen buffer gas.
Why
Zero to very low process emissions.
Safety backup to primary seal.
Where
Used with dual unpressurized containment seals (“tandem”).
High vapor pressure fluids, light hydrocarbons.
Hazardous/toxic fluids.
Clean, non-polymerizing, non-oxidizing fluids.
Used in combination with Plan 75 and/or Plan 76.
Preventative Maintenance
Clean, reliable, low pressure gas must be supplied to seal at all times.
Bottled gas supply is not recommended except as part of emergency backup system.
Primary seal leakage is indicated by pressure in the vent line.
Vent or drain are usually connected to low pressure vapor recovery/flare system.
Plan74
seal
end view
drain
inlet
1
3
2
C
D
A B
EF
G
1 - upset drain, normally closed
2 - gas inlet, normally open
3 - filter drain, normally closed
A - filter
B - regulator
C - flow meter
D - flow switch
E - pressure switch
F - pressure gage
G - check valve
Flow Solutions Division
Plan74
What
Pressurized barrier gas control system.
Gas seal support typically with nitrogen barrier gas.
Why
Isolate process fluid.
Zero process emissions.
Where
Used with dual pressurized gas seals (“double”).
High vapor pressure fluids, light hydrocarbons.
Hazardous/toxic fluids.
Services that do not tolerate liquid barrier seals.
Clean, non-polymerizing fluids.
Moderate temperature fluids.
Preventative Maintenance
Clean, reliable, pressurized gas must be supplied to seal at all times.
Barrier pressure is typically at least 25 psig (1.75 bar) above seal chamber pressure.
Flow meter indicates both inboard and outboard seal leakage.
Bottled gas supply is not recommended except as part of emergency backup system.
seal
end view
Plan75
drain
pressure switch
pressure gage
vent,
normally
open
orifice
level switch (high)
drain,
normally
closed
reservoir located
below seal drain port
isloation
valve
level
gage
Flow Solutions Division
Plan75
What
Drain from containment seal cavity to liquid collector and vapor recovery.
Why
Leakage collection for zero to very low process emissions.
Safety indicator for primary seal.
Where
May be used alone or with Plan 72 on containment seals.
Fluids that condense at ambient temperature.
High vapor pressure fluids, light hydrocarbons.
Hazardous/toxic fluids.
Clean, non-polymerizing, non-oxidizing fluids.
Preventative Maintenance
Collection reservoir must be located below seal drain and downward-sloped piping.
Continuously vent collection reservoir to low pressure vapor recovery/flare system.
Drain collection reservoir to liquid recovery system as needed.
Primary seal leakage is indicated by increased vent pressure.
Monitor regularly for liquid level, valve settings, and low vent pressure.
Plan76
seal
end view
vent
drain
vent,
normally
open
pressure gage
pressure switch
drain,
normally
closed
drain,
normally
closed
orifice
Flow Solutions Division
Plan76
What
Vent from containment seal cavity to vapor recovery.
Why
Leakage collection for zero to very low process emissions.
Safety indicator for primary seal.
Where
May be used alone or with Plan 72 on containment seals.
Fluids that do not condense at ambient temperature.
High vapor pressure fluids, light hydrocarbons.
Hazardous/toxic fluids.
Clean, non-polymerizing, non-oxidizing fluids.
Preventative Maintenance
Continuously vent to low pressure vapor recovery/flare system.
Vent piping should include a condensate drain.
Primary seal leakage is indicated by increased vent pressure.
Monitor regularly for valve settings, blocked lines, and low vent pressure.
seal
side view
seal
end view
3 ft. (0.9 m) max
1.5 - 2 ft.
(0.45 - 0.6 m)
Minimize line losses
Large diameter tubing
Upward sloping lines
Long radius bends
high point vent
low point drain
Vertical
Equipment
Horizontal
Equipment
AppendixA Good Piping Practices Single Seals - Plan 23 shown
seal
side view
seal
end view
AppendixB
Dual Seals - Plan 53A shown
4 ft. (1.2 m) max
low point drain
Vertical
Equipment
Horizontal
Equipment
1.5 - 2 ft.
(0.45 - 0.6 m)
Accessories
Airfin CoolersTM
Forced air or natural
convection seal coolers.
Reservoirs
General duty and
API 682 compliant
reservoirs.
Seal Cooler
Compact design
dual coil seal
cooler
Plans 21, 23 & 41 Plans 21, 23 & 41 Plans 21, 23 & 41
API 682
Seal Cooler
Seal cooler for
complete API 682
specifications.
Plans 53, 53A & 53B
Flow Solutions Division
Accessories
Circulator
Standalone dual seal
support system.
Gas Barrier
Control Panel
Complete control
system for dual gas
seals.
Refill Cart
Mobile cart to
manually fill liquid
reservoirs.
Plan 54 Plans 52 & 53 Plans 72 & 74
Piston
Accumulator
Hydraulically charged
reservoir for dual
seals.
Plan 53C
Accessories
Orifice
Plug and plate
style flush line
orifices.
Magnetic Separator
Iron particle separator
for seal flush.
Plans 11, 13, 14, & 21 Plans 31 & 41
Cyclone Separator
Solid particle separator
used in dirty flush
stream.
Plan 23
Seal Gard I & II
Combination flush
flow regulator and
meter.
Plan 32
Flow Solutions Division
Accessories
Gestra®
Steam Trap
Family of reliable
steam traps for
quench flows.
Bearing Gard II
& BGM
Bearing frame
protection devices.
SLD
Quench lubrication
device with
synthetic grease.
Plan 62 Plan 62 modified
DuraClear
Synthetic lubricants
from barrier fluid to
bearing oil.
Plans 52, 53 & 54
Notes
Notes
Notes
Notes
For your nearest Flow Solutions Division Service
and Sales location, look on the “Contact Us” page of
The information and specifications presented in these piping plans are believed to be accurate, but are supplied for information purposes only and should not be considered certified or as a
guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, with respect to the product. Although Flowserve
Corporation can provide general application guidelines, it cannot provide specific information for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for
the proper selection, installation, operation and maintenance of Flowserve products. Because Flowserve Corporation is continually improving and upgrading its product design, the specifications,
dimensions and information contained herein are subject to change without notice.
Flowserve Corporation Flow Solutions Division
Primary Worldwide Flow Solutions Division Locations Licensees, authorized agents, and affiliated companies located worldwide
GermanyBrazilMexico
Kalamazoo, MI
Phone 269-381-2650
Fax 269-382-8726
United States
Roosendaal
Phone 31-165-581400
Fax 31-165-552622
Netherlands
Dortmund
Phone 49-231-6964-0
Fax 49-231-6964-248
Edmonton, Alberta
Phone 780-464-1188
Fax 780-464-1801
Canada
Sao Paulo
Phone 55-11-4231-6300
Fax 55-11-4231-6326
Tlaxcala
Phone 52-2-461-6791
Fax 52-2-461-6847
Phone 65-6-8465100
Fax 65-6-747-1963
Osaka
Phone 81-72-885-5571
Fax 81-72-885-5575
Singapore Japan
Buenos Aires
Phone 54-11-4709-6800
Fax 54-11-4709-6800 ext 123
Argentina Australia
Marayong NSW
Phone 61-2-8822-7100
Fax 61-2-9679-7511
Scarborough, Ontario
Phone 416-292-2877
Fax 416-292-5190
www.Flowserve.com
REV 12/03
FTA160
Flow Solutions Division

More Related Content

What's hot

Psv scenario-and-calculation
Psv scenario-and-calculationPsv scenario-and-calculation
Psv scenario-and-calculationChingLuh Nike
 
Design and Rating of Trayed Distillation Columns
Design and Rating  of Trayed Distillation ColumnsDesign and Rating  of Trayed Distillation Columns
Design and Rating of Trayed Distillation ColumnsGerard B. Hawkins
 
Pressure Relief Devices_Presenation
Pressure Relief Devices_PresenationPressure Relief Devices_Presenation
Pressure Relief Devices_Presenationsumit handa
 
Flow control valves
Flow control valves Flow control valves
Flow control valves Rahul Sharma
 
Basics Fundamentals and working Principle of Centrifugal Pump.
Basics Fundamentals and working Principle of Centrifugal Pump.Basics Fundamentals and working Principle of Centrifugal Pump.
Basics Fundamentals and working Principle of Centrifugal Pump.SHASHI BHUSHAN
 
psv and pvrvdesign calculation.ppt
psv and pvrvdesign calculation.pptpsv and pvrvdesign calculation.ppt
psv and pvrvdesign calculation.pptssuser73bb74
 
Pumps and types of pumps in detail
Pumps and types of pumps in detailPumps and types of pumps in detail
Pumps and types of pumps in detailFARRUKH SHEHZAD
 
Pumps and Cavitation
Pumps and CavitationPumps and Cavitation
Pumps and CavitationLiving Online
 
FUNDAMENTAL OF VALVE DESIGN
FUNDAMENTAL OF VALVE DESIGN FUNDAMENTAL OF VALVE DESIGN
FUNDAMENTAL OF VALVE DESIGN MOHAMMAD ATIF ALI
 
Overview of Pressure Relief Valve
Overview of Pressure Relief ValveOverview of Pressure Relief Valve
Overview of Pressure Relief ValveAbhishek Nayak
 
sealing system for rotating shafts ( mechanical seals and packing )
sealing system for rotating shafts ( mechanical seals and packing )sealing system for rotating shafts ( mechanical seals and packing )
sealing system for rotating shafts ( mechanical seals and packing )elkeik
 

What's hot (20)

Centrifugal pump sizing tutorial
Centrifugal pump sizing   tutorialCentrifugal pump sizing   tutorial
Centrifugal pump sizing tutorial
 
Psv scenario-and-calculation
Psv scenario-and-calculationPsv scenario-and-calculation
Psv scenario-and-calculation
 
Valves
ValvesValves
Valves
 
Design and Rating of Trayed Distillation Columns
Design and Rating  of Trayed Distillation ColumnsDesign and Rating  of Trayed Distillation Columns
Design and Rating of Trayed Distillation Columns
 
Pressure Relief Devices_Presenation
Pressure Relief Devices_PresenationPressure Relief Devices_Presenation
Pressure Relief Devices_Presenation
 
Flow control valves
Flow control valves Flow control valves
Flow control valves
 
API STD 521
API STD 521API STD 521
API STD 521
 
Basics Fundamentals and working Principle of Centrifugal Pump.
Basics Fundamentals and working Principle of Centrifugal Pump.Basics Fundamentals and working Principle of Centrifugal Pump.
Basics Fundamentals and working Principle of Centrifugal Pump.
 
psv and pvrvdesign calculation.ppt
psv and pvrvdesign calculation.pptpsv and pvrvdesign calculation.ppt
psv and pvrvdesign calculation.ppt
 
Pumps and types of pumps in detail
Pumps and types of pumps in detailPumps and types of pumps in detail
Pumps and types of pumps in detail
 
Pumps and Cavitation
Pumps and CavitationPumps and Cavitation
Pumps and Cavitation
 
Pumps
PumpsPumps
Pumps
 
Control valves
Control  valvesControl  valves
Control valves
 
FUNDAMENTAL OF VALVE DESIGN
FUNDAMENTAL OF VALVE DESIGN FUNDAMENTAL OF VALVE DESIGN
FUNDAMENTAL OF VALVE DESIGN
 
flare system design.pdf
flare system design.pdfflare system design.pdf
flare system design.pdf
 
Pumps
PumpsPumps
Pumps
 
Overview of Pressure Relief Valve
Overview of Pressure Relief ValveOverview of Pressure Relief Valve
Overview of Pressure Relief Valve
 
Industrial valves
Industrial valvesIndustrial valves
Industrial valves
 
Pipe line sizing
Pipe line sizingPipe line sizing
Pipe line sizing
 
sealing system for rotating shafts ( mechanical seals and packing )
sealing system for rotating shafts ( mechanical seals and packing )sealing system for rotating shafts ( mechanical seals and packing )
sealing system for rotating shafts ( mechanical seals and packing )
 

Viewers also liked

Foreign part separator-FPS
Foreign part separator-FPSForeign part separator-FPS
Foreign part separator-FPSHardik Pujara
 
Effect of Geometric Configuration on Performance of Uniflow Cyclone
Effect of Geometric Configuration on Performance of Uniflow CycloneEffect of Geometric Configuration on Performance of Uniflow Cyclone
Effect of Geometric Configuration on Performance of Uniflow CycloneIJERD Editor
 
The Plastic Still
The Plastic StillThe Plastic Still
The Plastic StillHall
 
9 synthesis of reaction separation system lec 9 heterogenous separation
9 synthesis of reaction separation system lec 9 heterogenous separation9 synthesis of reaction separation system lec 9 heterogenous separation
9 synthesis of reaction separation system lec 9 heterogenous separationayimsevenfold
 
Pilot plant testing for hydrocyclone design
Pilot plant testing for hydrocyclone  design Pilot plant testing for hydrocyclone  design
Pilot plant testing for hydrocyclone design reyhane mazahernasab
 
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...Ruturaj Deshpande
 
7. air pollution control
7. air pollution control7. air pollution control
7. air pollution controlBhaskar Arun
 
14 stokes law and grit separators
14 stokes law and grit separators14 stokes law and grit separators
14 stokes law and grit separatorsAkepati S. Reddy
 
Venturi Scrubber - Dedusting
Venturi Scrubber - DedustingVenturi Scrubber - Dedusting
Venturi Scrubber - DedustingTomas Eriksson
 
Ntpc (national thermal power corporation) sipat boiler haxxo24 i~i
Ntpc (national thermal power corporation) sipat boiler haxxo24 i~iNtpc (national thermal power corporation) sipat boiler haxxo24 i~i
Ntpc (national thermal power corporation) sipat boiler haxxo24 i~ihaxxo24
 
Electrostatic precipitator design
Electrostatic precipitator designElectrostatic precipitator design
Electrostatic precipitator designIRS srl
 

Viewers also liked (20)

Mechanical seal
Mechanical sealMechanical seal
Mechanical seal
 
Fm 4
Fm 4Fm 4
Fm 4
 
Foreign part separator-FPS
Foreign part separator-FPSForeign part separator-FPS
Foreign part separator-FPS
 
Effect of Geometric Configuration on Performance of Uniflow Cyclone
Effect of Geometric Configuration on Performance of Uniflow CycloneEffect of Geometric Configuration on Performance of Uniflow Cyclone
Effect of Geometric Configuration on Performance of Uniflow Cyclone
 
The Plastic Still
The Plastic StillThe Plastic Still
The Plastic Still
 
Separator Qdk
Separator QdkSeparator Qdk
Separator Qdk
 
Air pollution notes
Air pollution notesAir pollution notes
Air pollution notes
 
9 synthesis of reaction separation system lec 9 heterogenous separation
9 synthesis of reaction separation system lec 9 heterogenous separation9 synthesis of reaction separation system lec 9 heterogenous separation
9 synthesis of reaction separation system lec 9 heterogenous separation
 
Pilot plant testing for hydrocyclone design
Pilot plant testing for hydrocyclone  design Pilot plant testing for hydrocyclone  design
Pilot plant testing for hydrocyclone design
 
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...
Analysis of Inferior Vena Cava Filter using STAR CCM+’s Lagrangian Particle T...
 
Dehydration bed
Dehydration bed Dehydration bed
Dehydration bed
 
7. air pollution control
7. air pollution control7. air pollution control
7. air pollution control
 
14 stokes law and grit separators
14 stokes law and grit separators14 stokes law and grit separators
14 stokes law and grit separators
 
L 25 and 26 final
L 25 and 26  finalL 25 and 26  final
L 25 and 26 final
 
Venturi Scrubber - Dedusting
Venturi Scrubber - DedustingVenturi Scrubber - Dedusting
Venturi Scrubber - Dedusting
 
VRM
VRMVRM
VRM
 
Cyclone Theory
Cyclone TheoryCyclone Theory
Cyclone Theory
 
Ntpc (national thermal power corporation) sipat boiler haxxo24 i~i
Ntpc (national thermal power corporation) sipat boiler haxxo24 i~iNtpc (national thermal power corporation) sipat boiler haxxo24 i~i
Ntpc (national thermal power corporation) sipat boiler haxxo24 i~i
 
Electrostatic precipitator design
Electrostatic precipitator designElectrostatic precipitator design
Electrostatic precipitator design
 
UASB reactors
UASB reactorsUASB reactors
UASB reactors
 

Similar to Flushing plans

vdocument.in_api-plans-flowserve.pdf
vdocument.in_api-plans-flowserve.pdfvdocument.in_api-plans-flowserve.pdf
vdocument.in_api-plans-flowserve.pdfssuser518208
 
Flowserve_Piping_Plan_Pocket_Pal (1).pdf
Flowserve_Piping_Plan_Pocket_Pal (1).pdfFlowserve_Piping_Plan_Pocket_Pal (1).pdf
Flowserve_Piping_Plan_Pocket_Pal (1).pdfAjinkyaRanaware1
 
API682 Mechanical Seal Plan and Requirements of Mechanical Seals
API682 Mechanical Seal Plan and Requirements of Mechanical SealsAPI682 Mechanical Seal Plan and Requirements of Mechanical Seals
API682 Mechanical Seal Plan and Requirements of Mechanical SealsElango Palaniappan
 
API 682 Seal piping plans.pdf
API 682 Seal piping plans.pdfAPI 682 Seal piping plans.pdf
API 682 Seal piping plans.pdfTeddy Setiady
 
Eagle burgmann api 682 4th edition piping plans_s-ap4-bkte pdfapp v2 13.05.14_en
Eagle burgmann api 682 4th edition piping plans_s-ap4-bkte pdfapp v2 13.05.14_enEagle burgmann api 682 4th edition piping plans_s-ap4-bkte pdfapp v2 13.05.14_en
Eagle burgmann api 682 4th edition piping plans_s-ap4-bkte pdfapp v2 13.05.14_enashraf mohamad
 
Present - Mechanical Seal3.pdf
Present - Mechanical Seal3.pdfPresent - Mechanical Seal3.pdf
Present - Mechanical Seal3.pdfAmorntepAiadphae1
 
Gas Lift Optimization and Troubleshooting
Gas Lift Optimization and Troubleshooting Gas Lift Optimization and Troubleshooting
Gas Lift Optimization and Troubleshooting Bailey LeRoux
 
Change-over-valve-Catalog_EN (1)
Change-over-valve-Catalog_EN (1)Change-over-valve-Catalog_EN (1)
Change-over-valve-Catalog_EN (1)Leser UK
 
Dry Pellet Chlorinator In-Line Chlorinator Model 400 Installation Guide
 Dry Pellet Chlorinator In-Line Chlorinator Model 400 Installation Guide Dry Pellet Chlorinator In-Line Chlorinator Model 400 Installation Guide
Dry Pellet Chlorinator In-Line Chlorinator Model 400 Installation GuideClean Water Systems
 
Condensate Return Solutions.ppt
Condensate Return Solutions.pptCondensate Return Solutions.ppt
Condensate Return Solutions.pptssuser8006c7
 
complete guide to process valves
complete guide to process valves complete guide to process valves
complete guide to process valves Elsayed Amer
 
Valves operation and functions complete guide
Valves operation and functions complete guideValves operation and functions complete guide
Valves operation and functions complete guideElsayed Amer
 
Chapter 51
Chapter 51Chapter 51
Chapter 51mcfalltj
 
Hazard operability study - in Industires and plant
Hazard operability study - in Industires and plantHazard operability study - in Industires and plant
Hazard operability study - in Industires and plantJayaKarthic1
 

Similar to Flushing plans (20)

vdocument.in_api-plans-flowserve.pdf
vdocument.in_api-plans-flowserve.pdfvdocument.in_api-plans-flowserve.pdf
vdocument.in_api-plans-flowserve.pdf
 
Flowserve_Piping_Plan_Pocket_Pal (1).pdf
Flowserve_Piping_Plan_Pocket_Pal (1).pdfFlowserve_Piping_Plan_Pocket_Pal (1).pdf
Flowserve_Piping_Plan_Pocket_Pal (1).pdf
 
Api682
Api682Api682
Api682
 
API682 Mechanical Seal Plan and Requirements of Mechanical Seals
API682 Mechanical Seal Plan and Requirements of Mechanical SealsAPI682 Mechanical Seal Plan and Requirements of Mechanical Seals
API682 Mechanical Seal Plan and Requirements of Mechanical Seals
 
API 682 Seal piping plans.pdf
API 682 Seal piping plans.pdfAPI 682 Seal piping plans.pdf
API 682 Seal piping plans.pdf
 
Api 682 4 th edition piping plans
Api 682 4 th edition piping plansApi 682 4 th edition piping plans
Api 682 4 th edition piping plans
 
Eagle burgmann api 682 4th edition piping plans_s-ap4-bkte pdfapp v2 13.05.14_en
Eagle burgmann api 682 4th edition piping plans_s-ap4-bkte pdfapp v2 13.05.14_enEagle burgmann api 682 4th edition piping plans_s-ap4-bkte pdfapp v2 13.05.14_en
Eagle burgmann api 682 4th edition piping plans_s-ap4-bkte pdfapp v2 13.05.14_en
 
Piping system
Piping systemPiping system
Piping system
 
Present - Mechanical Seal3.pdf
Present - Mechanical Seal3.pdfPresent - Mechanical Seal3.pdf
Present - Mechanical Seal3.pdf
 
Lessons learned solving pilot valve instability issues on LNG storage tanks
Lessons learned solving pilot valve instability issues on LNG storage tanksLessons learned solving pilot valve instability issues on LNG storage tanks
Lessons learned solving pilot valve instability issues on LNG storage tanks
 
Boiler Mountings
Boiler MountingsBoiler Mountings
Boiler Mountings
 
Gas Lift Optimization and Troubleshooting
Gas Lift Optimization and Troubleshooting Gas Lift Optimization and Troubleshooting
Gas Lift Optimization and Troubleshooting
 
Barometric condensor
Barometric condensorBarometric condensor
Barometric condensor
 
Change-over-valve-Catalog_EN (1)
Change-over-valve-Catalog_EN (1)Change-over-valve-Catalog_EN (1)
Change-over-valve-Catalog_EN (1)
 
Dry Pellet Chlorinator In-Line Chlorinator Model 400 Installation Guide
 Dry Pellet Chlorinator In-Line Chlorinator Model 400 Installation Guide Dry Pellet Chlorinator In-Line Chlorinator Model 400 Installation Guide
Dry Pellet Chlorinator In-Line Chlorinator Model 400 Installation Guide
 
Condensate Return Solutions.ppt
Condensate Return Solutions.pptCondensate Return Solutions.ppt
Condensate Return Solutions.ppt
 
complete guide to process valves
complete guide to process valves complete guide to process valves
complete guide to process valves
 
Valves operation and functions complete guide
Valves operation and functions complete guideValves operation and functions complete guide
Valves operation and functions complete guide
 
Chapter 51
Chapter 51Chapter 51
Chapter 51
 
Hazard operability study - in Industires and plant
Hazard operability study - in Industires and plantHazard operability study - in Industires and plant
Hazard operability study - in Industires and plant
 

Recently uploaded

Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Christo Ananth
 
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...RajaP95
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations120cr0395
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )Tsuyoshi Horigome
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)Suman Mia
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).pptssuser5c9d4b1
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlysanyuktamishra911
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingrknatarajan
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduitsrknatarajan
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 

Recently uploaded (20)

Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
 
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 

Flushing plans

  • 1. Flow Solutions Division Mechanical Seal Piping Plans Single Seals plans 01, 02, 11, 13, 14, 21, 23, 31, 32, 41 Dual Seals plans 52, 53A, 53B, 53C, 54 Quench Seals plan 62 Gas Seals plans 72, 74, 75, 76
  • 2. Flowserve’s Flow Solutions Division recognizes one of the most effective ways to achieve long, uninterrupted mechanical seal life is to create a healthy environment around the seal faces. Piping plans help keep mechanical seals running cool and clean, promote safe handling of dangerous fluids, and extend the operational availability of rotating equipment. This reference book is intended to provide a concise summary of the most essential piping plans used successfully in today’s process plants. Each plan shows all the standard and optional auxiliary components referenced in API Standard 682 2nd edition although not all components are needed in all applications. Consult your local Flowserve Flow Solutions Sales Engineer to identify the right solution that satisfies your application requirements. Mechanical Seal Piping Plans printed in USA © 2003 Flowserve Corporation
  • 3. For each piping plan identified in API Standard 682 2nd edition and recommended by Flowserve, each page set of this book shows: Seal End View Piping Plan Layout What, Why, and Where Pump Cross-section Mechanical Seal outlet inlet pressure source, normally open pressure gage pressure switch level switch (high) level switch (low) cooling in cooling coils drain, normally closed level gage cooling out reservoir liquid fill, normally closed Flow Solutions Division What • Pressurized barrier fluid circulation through reservoir. • Fluid is circulated by a pumping ring in the dual seal assembly. Why • Isolate process fluid. • Zero process emissions. Where • Used with dual pressurized seals (Arrangement 3 or “double”). • High vapor pressure fluids, light hydrocarbons. • Hazardous/toxic fluids. • Heat transfer fluids. • Dirty/abrasive or polymerizing fluids. • Mixers/agitators and vacuum service. Presventative Maintenance - Reference Appendix A • Piping loop must self-vent to reservoir locate at highest elevation. • Reservoir must be pressurized at all times - typically gas charge up to 200 psi (14bar). • Barrier fluid must be compatible with process. • Reservoir level gage indicates both inboard and outboard seal leakage. Plan53A Plan53A seal end view Preventative Maintenance • Viewed from drive end • Shows preferred gland connection orientation • Illustrated schematic of auxiliary components • Describes piping plans, their purpose, and typical applications • Simplified centrifugal pump shown for all plans • Shows typical seal arrangements • Provides general tips to improve reliability and for troubleshooting
  • 5. Flow Solutions Division Plan01 What Internal seal chamber flush from pump discharge. Operates similar to Plan 11. Why Seal chamber heat removal. Seal chamber venting on horizontal pumps. Reduce risk of freezing/polymerizing fluid in exposed Plan 11 piping. Where Custom seal chamber, most likely an ANSI/ASME pump. Clean, moderate temperature fluids. Used with single seals, rarely with dual seals. Preventative Maintenance Flush typically can not be directed over seal faces and seal heat removal is limited. Calculate flush flow rate based on head loss through internal porting.
  • 6. Plan02 seal end view open throat seal chamber shown
  • 7. Flow Solutions Division Plan02 What Dead-ended seal chamber with no flush. Why Simplicity - no environmental controls. Where Large bore/open throat seal chambers in moderate temperature services. Cooling jacket seal chambers in high temperature services. Clean fluids. Top-entry mixers/agitators with dry seals. Preventative Maintenance Process must have adequate boiling point margin to avoid vaporization. Cooling fluid in seal chamber jacket may be needed at all times in hot services. Often used in combination with steam quench, Plan 62.
  • 9. Flow Solutions Division Plan11 What Seal flush from pump discharge through orifice. Default single seal flush plan. Why Seal chamber heat removal. Seal chamber venting on horizontal pumps. Increase seal chamber pressure and fluid vapor margin. Where General applications with clean fluids. Clean, non-polymerizing fluids. Preventative Maintenance Use an orifice with a minimum 0.125" (3 mm) diameter. Calculate flow rates to size orifice for adequate seal chamber flow. Increase boiling point margin with proper orifice and throat bushing sizing. Flush should be directed over seal faces with piping at 12 O’clock position. Typical failure mode is a clogged orifice - check temperatures at pipe ends.
  • 11. Flow Solutions Division Plan13 What Recirculation from seal chamber to pump suction through orifice. Standard flush plan on vertical pumps. Why Continuous seal chamber venting on vertical pumps. Seal chamber heat removal. Where Vertical pumps. Seal chamber pressure is greater than suction pressure. Moderate temperature fluids with moderate solids. Non-polymerizing fluids. Preventative Maintenance Vent piping loop prior to starting vertical pumps. Use an orifice with a minimum 0.125" (3 mm) diameter. Calculate flow rates to size orifice for adequate seal chamber flow. Reduce seal chamber pressure with proper orifice and throat bushing sizing. Typical failure mode is a clogged orifice - check temperatures at pipe ends.
  • 13. Flow Solutions Division Plan14 What Seal flush from pump discharge and recirculation to pump suction with orifices. Combination of Plan 11 and Plan 13. Why Continuous seal chamber venting on vertical pumps. Seal chamber heat removal. Increase seal chamber pressure and fluid vapor margin. Where Vertical pumps. Clean, non-polymerizing fluids at moderate temperatures. Preventative Maintenance Use an orifice with a minimum 0.125" (3 mm) diameter. Calculate flow rates to size orifice for adequate seal chamber flow. Increase boiling point margin with proper orifice and throat bushing sizing. Flush should be directed over seal faces. Vent piping loop prior to starting vertical pumps. Typical failure mode is a clogged orifice - check temperatures at pipe ends.
  • 15. Flow Solutions Division Plan21 What Seal flush from pump discharge through orifice and cooler. Cooler in Plan 11 flush increases heat removal. Why Seal cooling. Reduce fluid temperature to increase fluid vapor margin. Reduce coking. Where High temperature service, typically less than 350° F (177° C). Hot water over 180° F (80° C). Clean, non-polymerizing fluids. Preventative Maintenance Seal cooler and piping must have air vents at highest elevation - vent before starting. When using 682 Seal Cooler, pipe with series flow to maximize heat transfer. Use an orifice with a minimum 1/8" (3 mm) diameter. Calculate flow rates to size orifice for adequate seal chamber flow. Increase boiling point margin with proper orifice and throat bushing sizing. Regularly monitor device inlet and outlet temperatures for signs of clogging or fouling.
  • 17. Flow Solutions Division Plan23 What Seal flush from internal pumping device through cooler. Standard flush plan in hot water services. Why Efficient seal cooling with low cooler duty. Increase fluid vapor margin. Improve water lubricity. Where High temperature service, hot hydrocarbons. Boiler feed water and hot water over 180° F (80° C). Clean, non-polymerizing fluids. Preventative Maintenance - Reference Appendix A Seal cooler and piping must have air vents at highest elevation - vent before starting. When using 682 Seal Cooler, pipe with parallel flow to minimize head loss. Seal chamber requires close clearance throat bushing to isolate process fluid. Tangential seal gland taps should enter at bottom and exit at top. Regularly monitor cooler inlet and outlet temperatures for signs of plugging or fouling. Process fluids with iron should flow through magnetic separator before cooler.
  • 19. Flow Solutions Division Plan31 What Seal flush from pump discharge through cyclone separator. Centrifuged solids are returned to pump suction. Why Seal chamber heat removal. Solids removal from flush and seal chamber. Where Dirty or contaminated fluids, water with sand or pipe slag. Non-polymerizing fluids. Preventative Maintenance Cyclone separator works best on solids with a specific gravity twice the process fluid. Seal chamber pressure must be nearly equal to suction pressure for proper flows. Piping should not include an orifice and is not expected to vent the seal chamber. Typical failure mode is clogged separator or pipes - check temperatures at pipe ends.
  • 21. Flow Solutions Division Plan32 What Seal flush from an external clean source. Why Seal chamber heat removal. Process and solids removal from seal chamber. Increase seal chamber pressure and fluid vapor margin. Where Dirty or contaminated fluids, paper pulp. High temperature service. Polymerizing and/or oxidizing fluids. Preventative Maintenance Use throat bushing sized to hold pressure or maintain flow velocity. To restrict dirty process fluid, regulate injection flow rate. To increase fluid vapor margin, regulate injection pressure. Injection fluid must be compatible with process fluid. Regularly monitor control system for closed valves or signs of plugging.
  • 22. Plan41 seal end view inlet drain, normally closed vents, normally closed cooling in cooler cooling out cooling coils cyclone separator
  • 23. Flow Solutions Division Plan41 What Seal flush from pump discharge through cyclone separator and cooler. Combination of Plan 21 and Plan 31. Why Seal cooling. Solids removal from flush and seal chamber. Where High temperature service, typically less than 350° F (177° C). Dirty or contaminated fluids, water with sand or pipe slag. Non-polymerizing fluids. Preventative Maintenance Seal cooler and piping must have air vents at highest elevation - vent before starting. When using 682 Seal Cooler, pipe with series flow to maximize heat transfer. Cyclone separator works best on solids with a specific gravity twice the process fluid. Seal chamber pressure must be nearly equal to suction pressure for proper flows. Typical failure mode is clogged separator or pipes - check temperatures at pipe ends.
  • 24. seal end view Plan52 outlet inlet drain, normally closed vent, normally open cooling in pressure gage cooling out cooling coils reservoir pressure switch level gage level switch (high) level switch (low) liquid fill, normally closed orifice
  • 25. Flow Solutions Division Plan52 What Unpressurized buffer fluid circulation through reservoir. Fluid is circulated by a pumping ring in the dual seal assembly. Why Outboard seal acts as a safety backup to the primary seal. Zero to very low process emissions. No process contamination is allowed. Where Used with dual unpressurized seals (“tandem”). High vapor pressure fluids, light hydrocarbons. Hazardous/toxic fluids. Heat transfer fluids. Preventative Maintenance - Reference Appendix B Piping loop must self-vent to vapor recovery/flare system near atmospheric pressure. Process vapor pressure is generally greater than reservoir pressure. Buffer fluid must be compatible with process leakage. Primary seal leakage is indicated by increased vent pressure. Reservoir level gage indicates outboard seal leakage.
  • 26. Plan53A seal end view outlet inlet pressure source, normally open pressure gage pressure switch level switch (high) level switch (low) cooling coils cooling in drain, normally closed cooling out reservoir liquid fill, normally closed level gage
  • 27. Flow Solutions Division Plan53A What Pressurized barrier fluid circulation through reservoir. Fluid is circulated by a pumping ring in the dual seal assembly. Why Isolate process fluid. Zero process emissions. Where Used with dual pressurized seals (“double”). High vapor pressure fluids, light hydrocarbons. Hazardous/toxic fluids. Heat transfer fluids. Dirty/abrasive or polymerizing fluids. Mixers/agitators and vacuum service. Preventative Maintenance - Reference Appendix B Piping loop must self-vent to reservoir located at highest elevation. Pressurize reservoir at all times, maximum gas charge 150 - 200 psi (10 - 14 bar). Barrier fluid must be compatible with process. Reservoir level gage indicates both inboard and outboard seal leakage.
  • 28. Plan53B seal end view outlet inlet pressure source, normally closed pressure gage pressure switch drain, normally closed liquid fill, normally closed vent, normally closed bladder accumulator finned pipe
  • 29. Flow Solutions Division Plan53B What Pressurized barrier fluid circulation with bladder accumulator. Fluid is circulated by a pumping ring in the dual seal assembly. Why Isolate process fluid. Zero process emissions. Higher pressure than Plan 53A. Where Used with dual pressurized seals (“double”). High vapor pressure fluids, light hydrocarbons. Hazardous/toxic fluids. Heat transfer fluids. Dirty/abrasive or polymerizing fluids. Preventative Maintenance - Reference Appendix B Piping loop must be fully vented before starting. Accumulator must be pressurized at all times, usually by gas charge. Barrier fluid must be compatible with process. Regularly monitor barrier pressure - manually add barrier fluid when pressure decays.
  • 30. Plan53C outlet inlet seal end view vent, normally closed pressure gage pressure switch level switch (low) cooling in drain, normally closed cooling out liquid fill, normally closed level gage cooling coils
  • 31. Flow Solutions Division Plan53C What Pressurized barrier fluid circulation with piston accumulator. Fluid is circulated by a pumping ring in the dual seal assembly. Why Isolate process fluid. Zero process emissions. Higher pressure than Plan 53A. Dynamic tracking of system pressure. Where Used with dual pressurized seals (“double”). High vapor pressure fluids, light hydrocarbons. Hazardous/toxic fluids. Heat transfer fluids. Preventative Maintenance - Reference Appendix B Piping loop must be fully vented before starting. Reference line must tolerate process contamination without plugging. Barrier fluid must be compatible with process. Reservoir level gage indicates both inboard and outboard seal leakage.
  • 32. Plan54 seal end view outlet inlet from / to external circulating system
  • 33. Flow Solutions Division Plan54 What Pressurized barrier fluid circulation by external system. Why Isolate process fluid. Zero process emissions. Seal cannot induce circulation. Where Used with dual pressurized seals (“double”). High vapor pressure fluids, light hydrocarbons. Hazardous/toxic fluids. Heat transfer fluids. Dirty/abrasive or polymerizing fluids. Mixers/agitators. Preventative Maintenance Piping loop must be fully vented before starting. Circulating system must be pressurized and energized at all times. Barrier fluid must be compatible with process. Circulating system level gage indicates both inboard and outboard seal leakage.
  • 34. Plan62 seal end view inlet drain pressure gage steam trap (steam quench) quench, normally open drain, normally open
  • 35. Flow Solutions Division Plan62 What External quench on atmospheric side of seal. Quench fluids typically steam, nitrogen, or water. Why Prevent solids buildup on atmospheric side of seal. Prevent icing. Where Used with single seals. Oxidizing fluids or fluids that coke, hot hydrocarbons. Crystallizing fluids or fluids that salt out. Caustic. Cold fluids less than 32° F (0° C). Preventative Maintenance Quench inlet should be on top of gland with outlet/drain on bottom. Quench pressure should be limited to 3 psi (0.2 bar) or less. Use throttle bushing on atmospheric side of seal to direct quench flow to seal drain. Monitor regularly, checking for closed valves, blocked lines, and steam trap condition.
  • 36. Plan72 seal end view vent drain inlet 1 3 2 C D A B E F H G 1 - drain 2 - vent 3 - gas inlet, normally open 4 - filter drain, normally closed 4 A - filter B - regulator C - orifice D - flow meter E - flow switch F - pressure switch G - pressure gage H - check valve
  • 37. Flow Solutions Division Plan72 What Unpressurized buffer gas control system. Containment seal support typically with nitrogen buffer gas. Why Zero to very low process emissions. Safety backup to primary seal. Where Used with dual unpressurized containment seals (“tandem”). High vapor pressure fluids, light hydrocarbons. Hazardous/toxic fluids. Clean, non-polymerizing, non-oxidizing fluids. Used in combination with Plan 75 and/or Plan 76. Preventative Maintenance Clean, reliable, low pressure gas must be supplied to seal at all times. Bottled gas supply is not recommended except as part of emergency backup system. Primary seal leakage is indicated by pressure in the vent line. Vent or drain are usually connected to low pressure vapor recovery/flare system.
  • 38. Plan74 seal end view drain inlet 1 3 2 C D A B EF G 1 - upset drain, normally closed 2 - gas inlet, normally open 3 - filter drain, normally closed A - filter B - regulator C - flow meter D - flow switch E - pressure switch F - pressure gage G - check valve
  • 39. Flow Solutions Division Plan74 What Pressurized barrier gas control system. Gas seal support typically with nitrogen barrier gas. Why Isolate process fluid. Zero process emissions. Where Used with dual pressurized gas seals (“double”). High vapor pressure fluids, light hydrocarbons. Hazardous/toxic fluids. Services that do not tolerate liquid barrier seals. Clean, non-polymerizing fluids. Moderate temperature fluids. Preventative Maintenance Clean, reliable, pressurized gas must be supplied to seal at all times. Barrier pressure is typically at least 25 psig (1.75 bar) above seal chamber pressure. Flow meter indicates both inboard and outboard seal leakage. Bottled gas supply is not recommended except as part of emergency backup system.
  • 40. seal end view Plan75 drain pressure switch pressure gage vent, normally open orifice level switch (high) drain, normally closed reservoir located below seal drain port isloation valve level gage
  • 41. Flow Solutions Division Plan75 What Drain from containment seal cavity to liquid collector and vapor recovery. Why Leakage collection for zero to very low process emissions. Safety indicator for primary seal. Where May be used alone or with Plan 72 on containment seals. Fluids that condense at ambient temperature. High vapor pressure fluids, light hydrocarbons. Hazardous/toxic fluids. Clean, non-polymerizing, non-oxidizing fluids. Preventative Maintenance Collection reservoir must be located below seal drain and downward-sloped piping. Continuously vent collection reservoir to low pressure vapor recovery/flare system. Drain collection reservoir to liquid recovery system as needed. Primary seal leakage is indicated by increased vent pressure. Monitor regularly for liquid level, valve settings, and low vent pressure.
  • 42. Plan76 seal end view vent drain vent, normally open pressure gage pressure switch drain, normally closed drain, normally closed orifice
  • 43. Flow Solutions Division Plan76 What Vent from containment seal cavity to vapor recovery. Why Leakage collection for zero to very low process emissions. Safety indicator for primary seal. Where May be used alone or with Plan 72 on containment seals. Fluids that do not condense at ambient temperature. High vapor pressure fluids, light hydrocarbons. Hazardous/toxic fluids. Clean, non-polymerizing, non-oxidizing fluids. Preventative Maintenance Continuously vent to low pressure vapor recovery/flare system. Vent piping should include a condensate drain. Primary seal leakage is indicated by increased vent pressure. Monitor regularly for valve settings, blocked lines, and low vent pressure.
  • 44. seal side view seal end view 3 ft. (0.9 m) max 1.5 - 2 ft. (0.45 - 0.6 m) Minimize line losses Large diameter tubing Upward sloping lines Long radius bends high point vent low point drain Vertical Equipment Horizontal Equipment AppendixA Good Piping Practices Single Seals - Plan 23 shown
  • 45. seal side view seal end view AppendixB Dual Seals - Plan 53A shown 4 ft. (1.2 m) max low point drain Vertical Equipment Horizontal Equipment 1.5 - 2 ft. (0.45 - 0.6 m)
  • 46. Accessories Airfin CoolersTM Forced air or natural convection seal coolers. Reservoirs General duty and API 682 compliant reservoirs. Seal Cooler Compact design dual coil seal cooler Plans 21, 23 & 41 Plans 21, 23 & 41 Plans 21, 23 & 41 API 682 Seal Cooler Seal cooler for complete API 682 specifications. Plans 53, 53A & 53B
  • 47. Flow Solutions Division Accessories Circulator Standalone dual seal support system. Gas Barrier Control Panel Complete control system for dual gas seals. Refill Cart Mobile cart to manually fill liquid reservoirs. Plan 54 Plans 52 & 53 Plans 72 & 74 Piston Accumulator Hydraulically charged reservoir for dual seals. Plan 53C
  • 48. Accessories Orifice Plug and plate style flush line orifices. Magnetic Separator Iron particle separator for seal flush. Plans 11, 13, 14, & 21 Plans 31 & 41 Cyclone Separator Solid particle separator used in dirty flush stream. Plan 23 Seal Gard I & II Combination flush flow regulator and meter. Plan 32
  • 49. Flow Solutions Division Accessories Gestra® Steam Trap Family of reliable steam traps for quench flows. Bearing Gard II & BGM Bearing frame protection devices. SLD Quench lubrication device with synthetic grease. Plan 62 Plan 62 modified DuraClear Synthetic lubricants from barrier fluid to bearing oil. Plans 52, 53 & 54
  • 50. Notes
  • 51. Notes
  • 52. Notes
  • 53. Notes
  • 54. For your nearest Flow Solutions Division Service and Sales location, look on the “Contact Us” page of The information and specifications presented in these piping plans are believed to be accurate, but are supplied for information purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, with respect to the product. Although Flowserve Corporation can provide general application guidelines, it cannot provide specific information for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper selection, installation, operation and maintenance of Flowserve products. Because Flowserve Corporation is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Flowserve Corporation Flow Solutions Division Primary Worldwide Flow Solutions Division Locations Licensees, authorized agents, and affiliated companies located worldwide GermanyBrazilMexico Kalamazoo, MI Phone 269-381-2650 Fax 269-382-8726 United States Roosendaal Phone 31-165-581400 Fax 31-165-552622 Netherlands Dortmund Phone 49-231-6964-0 Fax 49-231-6964-248 Edmonton, Alberta Phone 780-464-1188 Fax 780-464-1801 Canada Sao Paulo Phone 55-11-4231-6300 Fax 55-11-4231-6326 Tlaxcala Phone 52-2-461-6791 Fax 52-2-461-6847 Phone 65-6-8465100 Fax 65-6-747-1963 Osaka Phone 81-72-885-5571 Fax 81-72-885-5575 Singapore Japan Buenos Aires Phone 54-11-4709-6800 Fax 54-11-4709-6800 ext 123 Argentina Australia Marayong NSW Phone 61-2-8822-7100 Fax 61-2-9679-7511 Scarborough, Ontario Phone 416-292-2877 Fax 416-292-5190 www.Flowserve.com REV 12/03 FTA160 Flow Solutions Division