A design proposal with the objective of 1) providing sufficient Lighting to the Dual Carriageway under the King Fahad & Tahalia Roads Intersection during Daytime, Night Time and Emergency scenarios and 2) providing excellent wall grazing effect on the writing on the walls of the underpass.
Dubai Call Girls Pro Domain O525547819 Call Girls Dubai Doux
Fahad & Tahalia Roads Underpass LED Lighting
1. November 01, 2013 _Sector Confidential1
King Fahad & Tahaliya
Roads Intersection
Underpass LED Lighting
Michael T. Santiago|REE.AILP.MIES.
Lighting Applications Design Supervisor
Philips – Saudi Lighting Company
2. November 01, 2013 _Sector Confidential2
King Fahad & Tahaliya Roads Intersection Underpass LED Lighting
OBJECTIVE OF THE LIGTING CALCULATION
1) Provide Sufficient Lighting to Dual Roadway during Daytime, Nighttime and Emergency
2) Provide excellent wall grazing effect on the writing on the wall
3. November 01, 2013 _Sector Confidential3
King Fahad & Tahaliya Roads Intersection Underpass LED Lighting
PLAN OF ROAD
1) Speed of Road
2) Daily Traffic: Heavy (w/o provision for
pedestrians and cyclists)
3) Dual Carriageway with 3-lanes per
direction
4. November 01, 2013 _Sector Confidential4
King Fahad & Tahaliya Roads Intersection Underpass LED Lighting
CONSIDERATION IN CALCULATION
1) Since the covered part of
the Tunnel is about 121m
long, we can consider it to
be a SHORT TUNNEL or an
UNDERPASS.
2) As soon as Luminance on
Threshold (LTH)is known,
we shall target 50% of it.
3) Given is the Allowed Speed
Limit which is 100 km/h
4) The formula to determine
LTH is the L20 Method:
LTH = k x L20
THRESHOLD LUMINANCE
REFERENCE:
CIE 88:2004, 2nd edition - GUIDE FOR THE LIGHTING OF ROAD TUNNELS AND UNDERPASSES
5. November 01, 2013 _Sector Confidential5
King Fahad & Tahaliya Roads Intersection Underpass LED Lighting
CONSIDERATION IN CALCULATION
L20 = LC + LR + LE
L20 = 8 + 3 + 8 kcd/m2
L20 = 19,000 cd/m2
6. November 01, 2013 _Sector Confidential6
King Fahad & Tahaliya Roads Intersection Underpass LED Lighting
CONSIDERATION IN CALCULATION
L20 = 19,000 cd/m2
L20 = 19,000 cd/m2 x 3%
L20 = 570 cd/m2
LTH = k x L20
LTH = 0.08 x 570 cd/m2
LTH = 45.6 cd/m2
FOR SHORT TUNNELS: 45.6 cd/m2 x 50%
LTH = 22.8 cd/m2
Speed (km/h) k
60 0.05
80 0.06
100 0.08
120 0.10
Table A.1.3 Ratio, k, for various speeds
7. November 01, 2013 _Sector Confidential7
King Fahad & Tahaliya Roads Intersection Underpass LED Lighting
TARGET VALUES: UNDERPASS
LAVE EAVE UO UL Emin
Day Time >22.8 cd/m2 >500 lux >0.40 >0.60 NA
Night Time >4 cd/m2 NA >0.40 >0.60 NA
TYPICAL VALUES
LAVE
Maintenance Factor 0.90
q0 0.070
Road Reflectance Class R3
8. November 01, 2013 _Sector Confidential8
King Fahad & Tahaliya Roads Intersection Underpass LED Lighting
TARGET VALUES: WALL GRAZE
King Fahad Road being one of Riyadh’s busiest streets, is bustling with lighted buildings
and multiple road lighting posts and highmasts, thus we can consider it to have high
ambient light level with an average vertical target of 560 lux from beginning to the end
of the wall sign.
9. November 01, 2013 _Sector Confidential9
King Fahad & Tahaliya Roads Intersection Underpass LED Lighting
LIGHTING LAYOUT
Section View
LED6444 will provide Day and
Night lighting to the underpass
eW GrazeMX Powercore
for Wall Grazing & Emergency
10. November 01, 2013 _Sector Confidential10
King Fahad & Tahaliya Roads Intersection Underpass LED Lighting
LIGHTING LAYOUT
Plan View
11. November 01, 2013 _Sector Confidential11
King Fahad & Tahaliya Roads Intersection Underpass LED Lighting
LIGHTING LAYOUT
Wall Mounting Details Luminaire Spacing
12. November 01, 2013 _Sector Confidential12
King Fahad & Tahaliya Roads Intersection Underpass LED Lighting
CALCULATION RESULTS*
*Since the layout is typical and mirrored, we shall show only results of 1 direction
CALCULATION RESULTS SUMMARY FOR DAY TIME LIGHTING
Target Values ENTRANCE (40 m) MIDDLE (41 m) EXIT (40 m)
Eave = 500 lux 480 lux 511 lux 480 lux
G1 (min/ave) = 0.40 0.571 0.901 0.571
Lave = 22.8 cd/m2
22 cd/m² 23 cd/m² 20 cd/m²
U0 = 0.40 0.57 0.86 0.44
UL = 0.60 0.63 0.99 0.49
CALCULATION RESULTS SUMMARY FOR NIGHT TIME LIGHTING
Target Values ENTRANCE (40 m) MIDDLE (41 m) EXIT (40 m)
Eave = 90 lux 92 lux 97 lux 92 lux
G1 (min/ave) = 0.40 0.493 0.685 0.492
Lave = 4.0 cd/m2
4.22 cd/m² 4.41 cd/m² 3.90 cd/m²
U0 = 0.40 0.60 0.87 0.37
UL = 0.60 0.63 0.93 0.49
CALCULATION RESULTS SUMMARY FOR WALL GRAZE LIGHTING
Target Values BEGINNING TO END (160 m)
Eave = 560 lux (North)
600 lux
Eave = 560 lux (South)
596 lux
13. Thank you for your
valued attention!
michael.santiago@philips.com
966-11-4940658 ext 113
966-56-262-3490