OPEN CHANNEL FLOW
Open channel flow is a flow of liquid, basically water in a conduit with a free surface. The open
channel flows are driven by gravity alone, and the pressure gradient at the atmospheric interface
is negligible.
Closed duct flows are full of fluid, have no free surface within, and are driven by a pressure
gradient along the duct axis.
That is a surface on which pressure is equal to local atmospheric pressure.
Open channel flows are characterized by the presence of a liquid-gas interface called the free
surface. Some are natural flows such as rivers, creeks and floods, some are human made
systems such as fresh water aquaducts, irrigation, sewers and drainage ditches.
An open channel always has two sides and a bottom, where the flow satisfies the no-slip
condition. Therefore even a straight channel has a three-dimensional velocity distribution. Some
measurements of straight channel velocity contours are shown below.
The profiles are quite complex, with maximum velocity typically occurring in the midplane
about 20% below the surface.
COMPARISON OF OPEN CHANNEL FLOW AND PIPE FLOW
OPEN CHANNEL FLOW PIPE FLOW
Open channel flow must have a free surface. No free surface in pipe flow.
A free surface is subject to atmospheric
pressure.
No direct atmospheric pressure, hydraulic
pressure only.
Flow area is determined by the geometry of the
channel plus the level of free surface, which is
likely to change along the flow direction and
with as well as time.
Flow area is fixed by the pipe dimensions. The
cross section of a pipe is usually circular.
The cross section may be of any from circular
to irregular form of natural streams, which may
change along the flow direction and as well as
with time.
The cross section of a pipe is usually circular.
The depth of flow, discharge and the slopes of
channel bottom and of the free surface are
interdependent.
No such dependence.
TYPES OF OPEN CHANNEL FLOWS
The most common method of classifying open channel flow is by the rate of change of the free
surface depth. The simplest and most widely analyzed case in uniform flow.
Type of flow Description
Steady flow When discharge (Q) does not change with time.
Uniform flow When depth of fluid does not change for a selected length or section of
the channel.
Uniform steady flow When discharge does not change with time and depth remains constant
for a selected section. Cross section should remain unchanged, referred
to as a prismatic channel.
Varied steady flow When depth changes but discharge remains the same.
Varied unsteady flow When both depth and discharge change along a channel length of
interest.
Rapidly varying flow Depth change is rapid.
Gradually varying
flow
Depth change is gradual.
1. Rapidly varying flow
2. Gradually varying flow
3. Hydraulic jump
4. Weir and waterfall
5. Gradually varying
6. Hydraulic drop due to change in channel slope
PARAMETER USED IN OPEN CHANNEL FLOW ANALYSIS
Hydraulic radius, R of open channel flow
R is a ratio of flow cross sectional area, A and wetted perimeter (WP)
WP
A
R =
R : Hydraulic radius
A : Flow cross sectional area
WP : Wetted perimeter
Reynolds number for open channel flow.
υμ
ρ VRVR
==Re
Re < 500 – laminar flow
Re > 2000 – turbulent flow
Reynolds number for pipe flow
υμ
ρ VDVD
==Re
Re < 2000 – laminar flow
Re > 4000 – turbulent flow
Froude number, Fr
The Froude number (Fr) is a dimensionless number defined as the ratio of channel velocity to
the speed of propagation of a small disturbance wave in the channel.
For a rectangular or very wide constant depth channel, Froude number can be defined as :
hgy
V
Fr ==
speedwaveSurface
velocityFlow
where,
V = Velocity
g = gravity
yh = Hydraulic depth
T
A
yh =
A = Area
T = Top width of the channel
Fr < 1.0 → Sub-critical flow
Fr = 1.0 or when hgyV = → Critical flow
Fr > 1.0 → Super-critical flow
A combination of both numbers is used to describe channel flow conditions.
THE CHEZY FORMULA
Uniform flow can occur in long straight runs of constant slope and constant channel cross
section. The water depth is constant at nyy = , and the velocity is constant at 0VV = . The slope be
θtan0 =S , where θ is the angle the bottom makes with the horizontal, considered positive for
downhill flow. From Bernoulli equation, the head loss becomes:
LSzzhf 021 =−=
where L is the horizontal distance between section 1 and 2.
Head loss from Darcy-Weisbach is:
g
V
D
L
fh
h
f
2
2
=
radiusHydraulic
diameterHydraulic
44
=
=
×==
h
h
hh
R
D
WP
A
RD
2
1
0
2
12
1
0
8
SR
f
g
V h ⋅⋅⎟⎟
⎠
⎞
⎜⎜
⎝
⎛
=
For a given shape and bottom roughness, the quantity
2
1
8
⎟⎟
⎠
⎞
⎜⎜
⎝
⎛
f
g
is constant and can be denoted by C.
2
1
8
⎟⎟
⎠
⎞
⎜⎜
⎝
⎛
=
f
g
C
Finally, the velocity V0 can be expressed as :
( )2
1
0
2
1
0
2
1
2
1
0
8
SRCSR
f
g
V hh ⋅=⋅⋅⎟⎟
⎠
⎞
⎜⎜
⎝
⎛
=
( )2
1
0SRCAQ h⋅=
These are called Chezy formulas, first developed by the French engineer Antoine Chezy in
conjuction with his experiments on the Saine River and the Courpalet Canal in 1769.
The quantity C, called the Chezy coefficient, varies about 60 ft½
/s for small rough channels to
160 ft½
/s for large smooth channels (30 m½
/s to 90 m½
/s in SI units).
EXAMPLE
A straight rectangular channel is 6 ft wide and 3 ft deep and laid on a slope of 2°. The friction
factor is 0.022.
SOLUTION
sft108
022.0
2.3288 2
1
=
×
==
f
g
C
2
ft1836 =×=A
ft5.1
363
18
=
++
==
WP
A
Rh
°= 2tan0S
( ) ( )( ) ( )( ) /sft4502tan5.118108 3
2
1
2
1
0 =°×=⋅= SRCAQ h
For SI units, it can be used directly.
Uniform steady flow and Manning’s equation
When discharge remain the same and depth does not change, then we have uniform steady flow.
In this condition, the surface of water is parallel to the bed of the channel. To make sure water
(liquid) flow inside the channel, it must have certain angle of inclination, or the channel’s slope.
The slope of the channel (S) can be expressed as :-
• An angle = 1 degree
• As percent = 1%
• As fraction = 0.01 or 1 in 100
Manning’s equation is used to estimate the velocity of flow in a channel.
The SI units form of Manning’s equation:-
2
1
3
2
0.1
SR
n
V ⋅⋅=
V = Velocity of flow in a channel (m/s)
n = Channel surface roughness. Values developed through experimentation.
R = Hydraulic radius (A/WP) in meter
S = Slope of the channel
The English units form of Manning’s equation:-
2
1
3
2
49.1
SR
n
V ⋅⋅=
V = Velocity of flow in a channel (ft/s)
R = Hydraulic radius (A/WP) in feet
Example of the n values:-
The flowrate of a channel could be determined by :-
2
1
3
2
0.1
SAR
n
AVQ ⋅⋅==
where Q is in m3
/s.
For uniform flow, Q is referred to as normal discharge.
The above equation can also be re-arranged such that :-
2
1
3
2
S
nQ
AR =
The left hand side equation is based on channel geometry.
Example #01
Determine normal discharge for a 200 mm inside diameter common clay drainage tile running
half-full if the slope drops 1m over 1000m.
2
1
3
2
0.1
SAR
n
Q ⋅⋅=
013.0=n
2
2
m0157.0
42
1
=×=
D
A
π
m3142.0
2
1
perimeter,Wetted =×= DWP π
m05.0
3142.0
0157.0
===
WP
A
R
001.0=S
/sm1018.5
0.1 332
1
3
2
−
×=⋅⋅= SAR
n
Q
Example #02
Calculate slope of channel if normal discharge is 50 ft3
/s. Channel is formed, unfinished
concrete.
English unit !!!
2
1
3
2
49.1
SAR
n
Q ⋅⋅= →
3
2
2
1
49.1 AR
Qn
S =
017.0
ft24.1
WP
A
R
ft66.9
ft12 2
=
==
=
=
n
WP
A
00169.0=S
(Channel should drop 1.69 feet for every 1000 feet length.
Example #03
Design a rectangular channel in formed, unfinished concrete with below mention specifications.
Normal flowrate = 5.75 m3
/s
S = 1.2%
Normal depth = half of the width of the channel.
Since we have to design the channel, use this equation.
2
1
3
2
S
nQ
AR =
Y=B/2
B
( )
892.0
012.0
75.5017.0
2
1
2
1
3
2
=
×
==
S
nQ
AR
22
2
BB
BBYA =×==
BYBWP 22 =+=
4
B
WP
A
R ==
892.0
42
3
2
2
3
2
=⎟
⎠
⎞
⎜
⎝
⎛
⎟⎟
⎠
⎞
⎜⎜
⎝
⎛
=
BB
AR
m88.0
m76.1
=
=
Y
B
Example #04
In a rectangular channel as mention in Example #03, the final width was set at 2m and the
maximum discharge is 12m3
/s. Find the normal depth for this maximum discharge.
2
1
3
2
S
nQ
AR =
Y=B/2
2
( )
862257.1
012.0
12017.0
2
1
2
1
3
2
=
×
==
S
nQ
AR
YA 2=
YWP 22 +=
Y
Y
WP
A
R
22
2
+
==
( ) 862257.1
22
2
2
3
2
3
2
=⎟
⎠
⎞
⎜
⎝
⎛
+
=
Y
Y
YAR
Cannot solve directly. Use trial and error method. Can use MS Excel datasheet.
From Excel,
The normal depth must be 1.348 meter.
From MS Excel worksheet:
CONVEYANCE AND MOST EFFICIENT CHANNEL SHAPES
2
1
3
2
0.1
SAR
n
Q ⋅⋅=
Other than the S term, all other terms are related to channel cross section and its features.
These terms together are referred to as the Conveyance (K) of the channel.
3
2
0.1
AR
n
K ⋅=
Then,
2
1
SKQ ⋅=
WP
A
R =
K is maximum when wetted perimeter (WP) is the least for a give area. This is also the most
efficience cross section for conveying flow.
For circular section, half full flow is the most efficient.
COMPOUND SECTIONS
It is occurs when channel shape changes with flow depth. It is a typical idea in natural stream
sections during flooding.
At normal condition, water flows in the main channel. During floods, water spills over the flood
plain.
We need to know the flowrate, Q at various depths or vice-versa. So that we could design
channels or determine channel safety for various flood magnitudes.
Example #05
Channel type: Natural channel with levees.
Slope: 0.00015
Determine the normal discharge, Q for depth 3 ft and 6 ft.
COMPOUND SECTION
This is more realistic situation, where the channel roughness (value of n) may be different for
floodplain than the main channel.
In this case, we need to determine velocity for each sub-section, and then sum up the discharges
for the sections.
Example #06
Slope: 0.5%
n for bank = 0.06
n for main channel = 0.03
Calculate discharge for depth of 8 feet?
50051003
4008502
3204801
=×=
=×=
=×=
A
A
A
10551003
5735042
844801
=+=
=++=
=+=
P
P
P
∑=
=
⎟⎟
⎠
⎞
⎜⎜
⎝
⎛
=
n
i
ii
i
i
i
i
VAQ
S
P
A
n
V
1
2
13
2
49.1
( )( ) ( ) ( ) ( )
/sft9010
06.0
500105/500
03.0
40057/400
06.0
32084/320
005.049.1
2
3
2
3
2
3
2
2
1
=
⎥
⎥
⎦
⎤
⎢
⎢
⎣
⎡
×
+
×
+
×
=
Q
Q
ENERGY PRINCIPLES FOR OPEN CHANNEL FLOW
Energy at particular point in the channel is potential energy and kinetic energy.
Specific energy:
2
22
22 gA
Q
y
g
V
yE +=+=
areaflowsectionalCross
Discharge
Velocity
flowofDepth
=
=
=
=
A
Q
V
y
Total energy:
2
22
22 gA
Q
zy
g
V
zyE ++=++=
datumthefrombottomchanneltheofHeight=z
Example:
Rectangular channel width = 2 m
Depth = 1 m
Q = 4.0 m3/s 2 m
1 m
2 m
Height above datum = 2 m
Determine the specific energy and total energy.
Specific energy:
( )( )( )
m20.1
281.92
4
1
2 2
22
=+=+=
g
V
yE
Datum
Total energy:
E = datum height + specific energy = 2.0 + 1.2 = 3.2 m
Specific energy diagram
The specific energy can be plotted graphically as a function of depth of flow.
k
s
E
gA
Q
Ey
gA
Q
y
g
V
yE
energy,Kinetic
2
energy)(potentialenergy,Static
22
2
2
2
22
=
=
+=+=
Relationship between y and static energy, Es
Relationship between y and kinetic energy, Ek
2
2
2gA
Q
Ek =
For a rectangular channel;
Substitute Q with specific discharge (discharge per unit width),
B
Q
q =
Substitute area, A with, yBA ⋅=
2
2
2
2
22 gy
q
gA
Q
Ek ==
EXAMPLE
A rectangular channel, width is 4 m, flowrate is 12 m3
/s and depth of flow is 2.5 m.
Draw specific energy diagram
Find critical and alternate depth?
2
2
2
2
2
2
gy
q
yE
gA
Q
yE
+=
+=
/sm3
4
12 2
===
B
Q
q
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0 1 2 3 4 5 6
Energy
y
static E = y
kinetic E
total E
Meaning from the graph:
1. The diagram applies for a given cross section and discharge.
2. As the depth of flow increases, the static energy increases, and the kinetic energy
decreases
3. The total energy curve approaches the static energy curve for high depths and the
kinetic energy curve for small depths
4. The specific energy is minimum (Emin) for a particular depth – this depth happens to
be the critical depth – Depth for which the Froude’s number = 1.0. velocity = Vc.
5. Emin – only energy value with a singular depth!
6. Depths less than the critical depths – supercritical flow. Froude Number > 1.0. V > Vc.
7. Depths greater than the critical depths – subcritical flow. Froude Number < 1.0. V < Vc.
8. For all other energy values – there are two depth associated – one greater than the
critical depth and one less than the critical depth.
9. The two depths associated with the same energy values are referred to as – Alternate
depths
10. As discharge increases, the specific energy curves move to the upper right portion of
the chart.
2
2
2
2
2
2
gy
q
yE
gA
Q
yE
+=
+=
There is a minimum value of E at a certain value of y called the critical depth.
3
2
2
2
10
gy
q
dy
dE
−==
It shows that Emin occurs at yc
3
1
2
23
1
2
⎟⎟
⎠
⎞
⎜⎜
⎝
⎛
=⎟⎟
⎠
⎞
⎜⎜
⎝
⎛
=
gb
Q
g
q
yc
The associated minimum energy is ;
( ) cc yyEE
2
3
min ==
The depth, yc corresponds to channel velocity equal to the shallow-water wave propagation
speed, C0.
gy
V
Fr =
( ) 22232
ccccc yVygygyq ===
By comparison it follows that the critical channel velocity is:
( ) 0
2
1
CgyV cc ==
1=Fr
For , no solution exists.minEE <
For , two solutions are possible:minEE >
(1) Large depth with cVV < , called sub-critical.
(2) Small depth with , called super-critical.cVV >
In sub-critical flow, disturbances can propagate upstream because wave speed .VC >0
In super-critical flow, waves are swept downstream: Upstream is a zone of silence, and a small
obstruction in the flow will create a wedge-shape wave exactly analogous to the Mach waves.
The angle of these waves must be:
( )
V
gy
V
C 2
1
101
sinsin −−
==μ
The wave angle and the depth can thus be used as a simple measurement of super-critical flow
velocity.
Critical depth, yc
m971.0
81.9
3 3
1
23
1
2
=⎟⎟
⎠
⎞
⎜⎜
⎝
⎛
=⎟⎟
⎠
⎞
⎜⎜
⎝
⎛
=
g
q
yc
Minimum specific energy, Emin
( ) m457.1971.0
2
3
2
3
min === cyE
Since given depth was 2.5 m > 0.971 m, the given depth is sub-critical and the other depth
should be super-critical.
Now, determining alternate depths (Energy at 2.5 m)
m57.2
5.281.92
3
5.2
2 2
2
2
2
=
××
+=+=
gy
q
yE
This energy value is the same for the other alternate (super-critical) depth, so;
2
2
81.92
3
57.2
y
y
××
+=
Determine value of y by trial and error method. (use Excel ok)
super-critical alternate depth, y = 0.467 m
HYDRAULIC JUMP
In open channel flow a supercritical flow can change quickly back to a subcritical flow by
passing through a hydraulic jump
The upstream flow is fast and shallow.
The downstream flow is slow and deep.
The hydraulic jump is quite thick, ranging in length from 4 to 6 time the downstream depth.
It is very important that such jumps be located on specially designed aprons; otherwise the
channel bottom will be badly scoured by the agitation.
Jumps also mixed fluids very effectively and have application to sewage and water treatment
designs.
0 open channel   intro 5
0 open channel   intro 5

More Related Content

What's hot

Classification of weis new
Classification of weis newClassification of weis new
Classification of weis newsonukhan123
 
Critical flow through an Open channel
Critical flow through an Open channelCritical flow through an Open channel
Critical flow through an Open channelAjoy Kumar Saha
 
Chapter 9:Uniform flow in mobile boundary channel
Chapter 9:Uniform flow in mobile boundary channelChapter 9:Uniform flow in mobile boundary channel
Chapter 9:Uniform flow in mobile boundary channelBinu Karki
 
Open Channel VS Pipe Flow
Open Channel VS Pipe FlowOpen Channel VS Pipe Flow
Open Channel VS Pipe FlowFatma Abdalla
 
UNIT 5 Distribution Works.pptx
UNIT 5 Distribution Works.pptxUNIT 5 Distribution Works.pptx
UNIT 5 Distribution Works.pptxDivs97
 
Chapter 2 open channel hydraulics
Chapter 2 open channel hydraulicsChapter 2 open channel hydraulics
Chapter 2 open channel hydraulicsMohsin Siddique
 
FMHM-4th UNIT-R20-JNTUA.pptx
FMHM-4th UNIT-R20-JNTUA.pptxFMHM-4th UNIT-R20-JNTUA.pptx
FMHM-4th UNIT-R20-JNTUA.pptxMOKSHIT TECH
 
Rapidly varied flow
Rapidly varied flowRapidly varied flow
Rapidly varied flowMood Naik
 
Hardy cross method of pipe network analysis
Hardy cross method of pipe network analysisHardy cross method of pipe network analysis
Hardy cross method of pipe network analysissidrarashiddar
 
flow through open channel
flow through open channelflow through open channel
flow through open channelmohitjain123
 
Lined or non erodible design channel study
Lined or non erodible design channel studyLined or non erodible design channel study
Lined or non erodible design channel studyroidghozi
 
Stage measurement
Stage measurementStage measurement
Stage measurementKiran Yadav
 

What's hot (20)

Gradually varied flow
Gradually varied flowGradually varied flow
Gradually varied flow
 
HYDRAULIC JUMP
HYDRAULIC JUMPHYDRAULIC JUMP
HYDRAULIC JUMP
 
Classification of weis new
Classification of weis newClassification of weis new
Classification of weis new
 
Open channels
Open channelsOpen channels
Open channels
 
Critical flow through an Open channel
Critical flow through an Open channelCritical flow through an Open channel
Critical flow through an Open channel
 
Chapter 9:Uniform flow in mobile boundary channel
Chapter 9:Uniform flow in mobile boundary channelChapter 9:Uniform flow in mobile boundary channel
Chapter 9:Uniform flow in mobile boundary channel
 
Open Channel VS Pipe Flow
Open Channel VS Pipe FlowOpen Channel VS Pipe Flow
Open Channel VS Pipe Flow
 
UNIT 5 Distribution Works.pptx
UNIT 5 Distribution Works.pptxUNIT 5 Distribution Works.pptx
UNIT 5 Distribution Works.pptx
 
Open channelhydraulics2
Open channelhydraulics2Open channelhydraulics2
Open channelhydraulics2
 
Chapter 2 open channel hydraulics
Chapter 2 open channel hydraulicsChapter 2 open channel hydraulics
Chapter 2 open channel hydraulics
 
Open channel flow
Open channel flowOpen channel flow
Open channel flow
 
FMHM-4th UNIT-R20-JNTUA.pptx
FMHM-4th UNIT-R20-JNTUA.pptxFMHM-4th UNIT-R20-JNTUA.pptx
FMHM-4th UNIT-R20-JNTUA.pptx
 
Rapidly varied flow
Rapidly varied flowRapidly varied flow
Rapidly varied flow
 
Presentation aboout flood routing
Presentation aboout flood routingPresentation aboout flood routing
Presentation aboout flood routing
 
Hardy cross method of pipe network analysis
Hardy cross method of pipe network analysisHardy cross method of pipe network analysis
Hardy cross method of pipe network analysis
 
Presentation 1 ce 801
Presentation  1  ce 801Presentation  1  ce 801
Presentation 1 ce 801
 
Chap1 open channel flow
Chap1 open channel flowChap1 open channel flow
Chap1 open channel flow
 
flow through open channel
flow through open channelflow through open channel
flow through open channel
 
Lined or non erodible design channel study
Lined or non erodible design channel studyLined or non erodible design channel study
Lined or non erodible design channel study
 
Stage measurement
Stage measurementStage measurement
Stage measurement
 

Similar to 0 open channel intro 5

UNIFORM FLOW OCF.pptx
UNIFORM FLOW OCF.pptxUNIFORM FLOW OCF.pptx
UNIFORM FLOW OCF.pptxreenarana28
 
UNIT 1 UNIFORM FLOW.pptx
UNIT 1 UNIFORM FLOW.pptxUNIT 1 UNIFORM FLOW.pptx
UNIT 1 UNIFORM FLOW.pptxreenarana28
 
Basic equation of fluid flow mechan.pptx
Basic equation of fluid flow mechan.pptxBasic equation of fluid flow mechan.pptx
Basic equation of fluid flow mechan.pptxAjithPArun1
 
economic channel section
economic channel sectioneconomic channel section
economic channel sectionVaibhav Pathak
 
Open channel flow equation
Open channel flow equationOpen channel flow equation
Open channel flow equationMrinmoy Majumder
 
Presentation on notches and weirs
Presentation on notches and weirsPresentation on notches and weirs
Presentation on notches and weirssush_vyas
 
Dymanics of open channel flow
Dymanics of open channel flowDymanics of open channel flow
Dymanics of open channel flowMohsin Siddique
 
Friction losses in turbulent flow (Fanning Equation).pdf
Friction losses in turbulent flow (Fanning Equation).pdfFriction losses in turbulent flow (Fanning Equation).pdf
Friction losses in turbulent flow (Fanning Equation).pdfSharpmark256
 
Water measurement
Water measurementWater measurement
Water measurementHina Bhatu
 
6. Flow Through uc Channels (CE).pdf
6. Flow Through uc Channels (CE).pdf6. Flow Through uc Channels (CE).pdf
6. Flow Through uc Channels (CE).pdfRakeshKumar660472
 
Lecture 2 manning
Lecture     2  manning   Lecture     2  manning
Lecture 2 manning LuayHameed
 
Ecuación de continuidad
Ecuación de continuidad Ecuación de continuidad
Ecuación de continuidad ErikCalvopia
 

Similar to 0 open channel intro 5 (20)

UNIFORM FLOW OCF.pptx
UNIFORM FLOW OCF.pptxUNIFORM FLOW OCF.pptx
UNIFORM FLOW OCF.pptx
 
UNIT 1 UNIFORM FLOW.pptx
UNIT 1 UNIFORM FLOW.pptxUNIT 1 UNIFORM FLOW.pptx
UNIT 1 UNIFORM FLOW.pptx
 
CHAPTER NO 2
CHAPTER NO 2 CHAPTER NO 2
CHAPTER NO 2
 
Basic equation of fluid flow mechan.pptx
Basic equation of fluid flow mechan.pptxBasic equation of fluid flow mechan.pptx
Basic equation of fluid flow mechan.pptx
 
Lecture 2.pptx
Lecture 2.pptxLecture 2.pptx
Lecture 2.pptx
 
economic channel section
economic channel sectioneconomic channel section
economic channel section
 
Open channel flow equation
Open channel flow equationOpen channel flow equation
Open channel flow equation
 
Chapter 1bbj.pptx
Chapter 1bbj.pptxChapter 1bbj.pptx
Chapter 1bbj.pptx
 
3.uniform flow.pptx
3.uniform flow.pptx3.uniform flow.pptx
3.uniform flow.pptx
 
Module 4
Module 4Module 4
Module 4
 
Open channel Flow
Open channel FlowOpen channel Flow
Open channel Flow
 
Presentation on notches and weirs
Presentation on notches and weirsPresentation on notches and weirs
Presentation on notches and weirs
 
Dymanics of open channel flow
Dymanics of open channel flowDymanics of open channel flow
Dymanics of open channel flow
 
Friction losses in turbulent flow (Fanning Equation).pdf
Friction losses in turbulent flow (Fanning Equation).pdfFriction losses in turbulent flow (Fanning Equation).pdf
Friction losses in turbulent flow (Fanning Equation).pdf
 
Water measurement
Water measurementWater measurement
Water measurement
 
6. Flow Through uc Channels (CE).pdf
6. Flow Through uc Channels (CE).pdf6. Flow Through uc Channels (CE).pdf
6. Flow Through uc Channels (CE).pdf
 
Lecture 1.pptx
Lecture 1.pptxLecture 1.pptx
Lecture 1.pptx
 
Lecture 2 manning
Lecture     2  manning   Lecture     2  manning
Lecture 2 manning
 
Qb103352
Qb103352Qb103352
Qb103352
 
Ecuación de continuidad
Ecuación de continuidad Ecuación de continuidad
Ecuación de continuidad
 

More from Refee Lubong

Sustainable facility management _ the facility manager's guide to optimizing ...
Sustainable facility management _ the facility manager's guide to optimizing ...Sustainable facility management _ the facility manager's guide to optimizing ...
Sustainable facility management _ the facility manager's guide to optimizing ...Refee Lubong
 
4 reciprocating pump
4 reciprocating pump4 reciprocating pump
4 reciprocating pumpRefee Lubong
 
4 pump 03 reciprocating pump
4 pump 03 reciprocating pump4 pump 03 reciprocating pump
4 pump 03 reciprocating pumpRefee Lubong
 
4 pump 02 centrifugal pump
4 pump 02 centrifugal pump4 pump 02 centrifugal pump
4 pump 02 centrifugal pumpRefee Lubong
 
1 open channel problems 2
1 open channel   problems 21 open channel   problems 2
1 open channel problems 2Refee Lubong
 
1 open channel problems 1-1
1 open channel   problems 1-11 open channel   problems 1-1
1 open channel problems 1-1Refee Lubong
 
Skmm4343 pipe system
Skmm4343 pipe systemSkmm4343 pipe system
Skmm4343 pipe systemRefee Lubong
 

More from Refee Lubong (9)

Sustainable facility management _ the facility manager's guide to optimizing ...
Sustainable facility management _ the facility manager's guide to optimizing ...Sustainable facility management _ the facility manager's guide to optimizing ...
Sustainable facility management _ the facility manager's guide to optimizing ...
 
4 reciprocating pump
4 reciprocating pump4 reciprocating pump
4 reciprocating pump
 
4 pump 03 reciprocating pump
4 pump 03 reciprocating pump4 pump 03 reciprocating pump
4 pump 03 reciprocating pump
 
4 pump 02 centrifugal pump
4 pump 02 centrifugal pump4 pump 02 centrifugal pump
4 pump 02 centrifugal pump
 
4 pump 01 pd pump
4 pump 01 pd pump4 pump 01 pd pump
4 pump 01 pd pump
 
1 resistance
1 resistance1 resistance
1 resistance
 
1 open channel problems 2
1 open channel   problems 21 open channel   problems 2
1 open channel problems 2
 
1 open channel problems 1-1
1 open channel   problems 1-11 open channel   problems 1-1
1 open channel problems 1-1
 
Skmm4343 pipe system
Skmm4343 pipe systemSkmm4343 pipe system
Skmm4343 pipe system
 

Recently uploaded

Curve setting (Basic Mine Surveying)_MI10412MI.pptx
Curve setting (Basic Mine Surveying)_MI10412MI.pptxCurve setting (Basic Mine Surveying)_MI10412MI.pptx
Curve setting (Basic Mine Surveying)_MI10412MI.pptxRomil Mishra
 
Module-1-Building Acoustics(Introduction)(Unit-1).pdf
Module-1-Building Acoustics(Introduction)(Unit-1).pdfModule-1-Building Acoustics(Introduction)(Unit-1).pdf
Module-1-Building Acoustics(Introduction)(Unit-1).pdfManish Kumar
 
Indian Tradition, Culture & Societies.pdf
Indian Tradition, Culture & Societies.pdfIndian Tradition, Culture & Societies.pdf
Indian Tradition, Culture & Societies.pdfalokitpathak01
 
Substation Automation SCADA and Gateway Solutions by BRH
Substation Automation SCADA and Gateway Solutions by BRHSubstation Automation SCADA and Gateway Solutions by BRH
Substation Automation SCADA and Gateway Solutions by BRHbirinder2
 
70 POWER PLANT IAE V2500 technical training
70 POWER PLANT IAE V2500 technical training70 POWER PLANT IAE V2500 technical training
70 POWER PLANT IAE V2500 technical trainingGladiatorsKasper
 
Structural Integrity Assessment Standards in Nigeria by Engr Nimot Muili
Structural Integrity Assessment Standards in Nigeria by Engr Nimot MuiliStructural Integrity Assessment Standards in Nigeria by Engr Nimot Muili
Structural Integrity Assessment Standards in Nigeria by Engr Nimot MuiliNimot Muili
 
tourism-management-srs_compress-software-engineering.pdf
tourism-management-srs_compress-software-engineering.pdftourism-management-srs_compress-software-engineering.pdf
tourism-management-srs_compress-software-engineering.pdfchess188chess188
 
Module-1-(Building Acoustics) Noise Control (Unit-3). pdf
Module-1-(Building Acoustics) Noise Control (Unit-3). pdfModule-1-(Building Acoustics) Noise Control (Unit-3). pdf
Module-1-(Building Acoustics) Noise Control (Unit-3). pdfManish Kumar
 
Turn leadership mistakes into a better future.pptx
Turn leadership mistakes into a better future.pptxTurn leadership mistakes into a better future.pptx
Turn leadership mistakes into a better future.pptxStephen Sitton
 
ADM100 Running Book for sap basis domain study
ADM100 Running Book for sap basis domain studyADM100 Running Book for sap basis domain study
ADM100 Running Book for sap basis domain studydhruvamdhruvil123
 
Robotics Group 10 (Control Schemes) cse.pdf
Robotics Group 10  (Control Schemes) cse.pdfRobotics Group 10  (Control Schemes) cse.pdf
Robotics Group 10 (Control Schemes) cse.pdfsahilsajad201
 
CS 3251 Programming in c all unit notes pdf
CS 3251 Programming in c all unit notes pdfCS 3251 Programming in c all unit notes pdf
CS 3251 Programming in c all unit notes pdfBalamuruganV28
 
Artificial Intelligence in Power System overview
Artificial Intelligence in Power System overviewArtificial Intelligence in Power System overview
Artificial Intelligence in Power System overviewsandhya757531
 
Javier_Fernandez_CARS_workshop_presentation.pptx
Javier_Fernandez_CARS_workshop_presentation.pptxJavier_Fernandez_CARS_workshop_presentation.pptx
Javier_Fernandez_CARS_workshop_presentation.pptxJavier Fernández Muñoz
 
TEST CASE GENERATION GENERATION BLOCK BOX APPROACH
TEST CASE GENERATION GENERATION BLOCK BOX APPROACHTEST CASE GENERATION GENERATION BLOCK BOX APPROACH
TEST CASE GENERATION GENERATION BLOCK BOX APPROACHSneha Padhiar
 
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.elesangwon
 
A brief look at visionOS - How to develop app on Apple's Vision Pro
A brief look at visionOS - How to develop app on Apple's Vision ProA brief look at visionOS - How to develop app on Apple's Vision Pro
A brief look at visionOS - How to develop app on Apple's Vision ProRay Yuan Liu
 
Katarzyna Lipka-Sidor - BIM School Course
Katarzyna Lipka-Sidor - BIM School CourseKatarzyna Lipka-Sidor - BIM School Course
Katarzyna Lipka-Sidor - BIM School Coursebim.edu.pl
 

Recently uploaded (20)

Designing pile caps according to ACI 318-19.pptx
Designing pile caps according to ACI 318-19.pptxDesigning pile caps according to ACI 318-19.pptx
Designing pile caps according to ACI 318-19.pptx
 
Curve setting (Basic Mine Surveying)_MI10412MI.pptx
Curve setting (Basic Mine Surveying)_MI10412MI.pptxCurve setting (Basic Mine Surveying)_MI10412MI.pptx
Curve setting (Basic Mine Surveying)_MI10412MI.pptx
 
Module-1-Building Acoustics(Introduction)(Unit-1).pdf
Module-1-Building Acoustics(Introduction)(Unit-1).pdfModule-1-Building Acoustics(Introduction)(Unit-1).pdf
Module-1-Building Acoustics(Introduction)(Unit-1).pdf
 
Indian Tradition, Culture & Societies.pdf
Indian Tradition, Culture & Societies.pdfIndian Tradition, Culture & Societies.pdf
Indian Tradition, Culture & Societies.pdf
 
Substation Automation SCADA and Gateway Solutions by BRH
Substation Automation SCADA and Gateway Solutions by BRHSubstation Automation SCADA and Gateway Solutions by BRH
Substation Automation SCADA and Gateway Solutions by BRH
 
70 POWER PLANT IAE V2500 technical training
70 POWER PLANT IAE V2500 technical training70 POWER PLANT IAE V2500 technical training
70 POWER PLANT IAE V2500 technical training
 
Structural Integrity Assessment Standards in Nigeria by Engr Nimot Muili
Structural Integrity Assessment Standards in Nigeria by Engr Nimot MuiliStructural Integrity Assessment Standards in Nigeria by Engr Nimot Muili
Structural Integrity Assessment Standards in Nigeria by Engr Nimot Muili
 
tourism-management-srs_compress-software-engineering.pdf
tourism-management-srs_compress-software-engineering.pdftourism-management-srs_compress-software-engineering.pdf
tourism-management-srs_compress-software-engineering.pdf
 
Module-1-(Building Acoustics) Noise Control (Unit-3). pdf
Module-1-(Building Acoustics) Noise Control (Unit-3). pdfModule-1-(Building Acoustics) Noise Control (Unit-3). pdf
Module-1-(Building Acoustics) Noise Control (Unit-3). pdf
 
Turn leadership mistakes into a better future.pptx
Turn leadership mistakes into a better future.pptxTurn leadership mistakes into a better future.pptx
Turn leadership mistakes into a better future.pptx
 
ADM100 Running Book for sap basis domain study
ADM100 Running Book for sap basis domain studyADM100 Running Book for sap basis domain study
ADM100 Running Book for sap basis domain study
 
Robotics Group 10 (Control Schemes) cse.pdf
Robotics Group 10  (Control Schemes) cse.pdfRobotics Group 10  (Control Schemes) cse.pdf
Robotics Group 10 (Control Schemes) cse.pdf
 
Versatile Engineering Construction Firms
Versatile Engineering Construction FirmsVersatile Engineering Construction Firms
Versatile Engineering Construction Firms
 
CS 3251 Programming in c all unit notes pdf
CS 3251 Programming in c all unit notes pdfCS 3251 Programming in c all unit notes pdf
CS 3251 Programming in c all unit notes pdf
 
Artificial Intelligence in Power System overview
Artificial Intelligence in Power System overviewArtificial Intelligence in Power System overview
Artificial Intelligence in Power System overview
 
Javier_Fernandez_CARS_workshop_presentation.pptx
Javier_Fernandez_CARS_workshop_presentation.pptxJavier_Fernandez_CARS_workshop_presentation.pptx
Javier_Fernandez_CARS_workshop_presentation.pptx
 
TEST CASE GENERATION GENERATION BLOCK BOX APPROACH
TEST CASE GENERATION GENERATION BLOCK BOX APPROACHTEST CASE GENERATION GENERATION BLOCK BOX APPROACH
TEST CASE GENERATION GENERATION BLOCK BOX APPROACH
 
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.
 
A brief look at visionOS - How to develop app on Apple's Vision Pro
A brief look at visionOS - How to develop app on Apple's Vision ProA brief look at visionOS - How to develop app on Apple's Vision Pro
A brief look at visionOS - How to develop app on Apple's Vision Pro
 
Katarzyna Lipka-Sidor - BIM School Course
Katarzyna Lipka-Sidor - BIM School CourseKatarzyna Lipka-Sidor - BIM School Course
Katarzyna Lipka-Sidor - BIM School Course
 

0 open channel intro 5

  • 1. OPEN CHANNEL FLOW Open channel flow is a flow of liquid, basically water in a conduit with a free surface. The open channel flows are driven by gravity alone, and the pressure gradient at the atmospheric interface is negligible. Closed duct flows are full of fluid, have no free surface within, and are driven by a pressure gradient along the duct axis. That is a surface on which pressure is equal to local atmospheric pressure. Open channel flows are characterized by the presence of a liquid-gas interface called the free surface. Some are natural flows such as rivers, creeks and floods, some are human made systems such as fresh water aquaducts, irrigation, sewers and drainage ditches.
  • 2.
  • 3. An open channel always has two sides and a bottom, where the flow satisfies the no-slip condition. Therefore even a straight channel has a three-dimensional velocity distribution. Some measurements of straight channel velocity contours are shown below. The profiles are quite complex, with maximum velocity typically occurring in the midplane about 20% below the surface.
  • 4. COMPARISON OF OPEN CHANNEL FLOW AND PIPE FLOW OPEN CHANNEL FLOW PIPE FLOW Open channel flow must have a free surface. No free surface in pipe flow. A free surface is subject to atmospheric pressure. No direct atmospheric pressure, hydraulic pressure only. Flow area is determined by the geometry of the channel plus the level of free surface, which is likely to change along the flow direction and with as well as time. Flow area is fixed by the pipe dimensions. The cross section of a pipe is usually circular. The cross section may be of any from circular to irregular form of natural streams, which may change along the flow direction and as well as with time. The cross section of a pipe is usually circular. The depth of flow, discharge and the slopes of channel bottom and of the free surface are interdependent. No such dependence.
  • 5. TYPES OF OPEN CHANNEL FLOWS The most common method of classifying open channel flow is by the rate of change of the free surface depth. The simplest and most widely analyzed case in uniform flow. Type of flow Description Steady flow When discharge (Q) does not change with time. Uniform flow When depth of fluid does not change for a selected length or section of the channel. Uniform steady flow When discharge does not change with time and depth remains constant for a selected section. Cross section should remain unchanged, referred to as a prismatic channel. Varied steady flow When depth changes but discharge remains the same. Varied unsteady flow When both depth and discharge change along a channel length of interest. Rapidly varying flow Depth change is rapid. Gradually varying flow Depth change is gradual.
  • 6. 1. Rapidly varying flow 2. Gradually varying flow 3. Hydraulic jump 4. Weir and waterfall 5. Gradually varying 6. Hydraulic drop due to change in channel slope
  • 7. PARAMETER USED IN OPEN CHANNEL FLOW ANALYSIS Hydraulic radius, R of open channel flow R is a ratio of flow cross sectional area, A and wetted perimeter (WP) WP A R = R : Hydraulic radius A : Flow cross sectional area WP : Wetted perimeter
  • 8.
  • 9. Reynolds number for open channel flow. υμ ρ VRVR ==Re Re < 500 – laminar flow Re > 2000 – turbulent flow Reynolds number for pipe flow υμ ρ VDVD ==Re Re < 2000 – laminar flow Re > 4000 – turbulent flow
  • 10. Froude number, Fr The Froude number (Fr) is a dimensionless number defined as the ratio of channel velocity to the speed of propagation of a small disturbance wave in the channel. For a rectangular or very wide constant depth channel, Froude number can be defined as : hgy V Fr == speedwaveSurface velocityFlow where, V = Velocity g = gravity yh = Hydraulic depth T A yh = A = Area T = Top width of the channel Fr < 1.0 → Sub-critical flow Fr = 1.0 or when hgyV = → Critical flow Fr > 1.0 → Super-critical flow A combination of both numbers is used to describe channel flow conditions.
  • 11. THE CHEZY FORMULA Uniform flow can occur in long straight runs of constant slope and constant channel cross section. The water depth is constant at nyy = , and the velocity is constant at 0VV = . The slope be θtan0 =S , where θ is the angle the bottom makes with the horizontal, considered positive for downhill flow. From Bernoulli equation, the head loss becomes: LSzzhf 021 =−= where L is the horizontal distance between section 1 and 2. Head loss from Darcy-Weisbach is: g V D L fh h f 2 2 = radiusHydraulic diameterHydraulic 44 = = ×== h h hh R D WP A RD 2 1 0 2 12 1 0 8 SR f g V h ⋅⋅⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ = For a given shape and bottom roughness, the quantity 2 1 8 ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ f g is constant and can be denoted by C. 2 1 8 ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ = f g C
  • 12. Finally, the velocity V0 can be expressed as : ( )2 1 0 2 1 0 2 1 2 1 0 8 SRCSR f g V hh ⋅=⋅⋅⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ = ( )2 1 0SRCAQ h⋅= These are called Chezy formulas, first developed by the French engineer Antoine Chezy in conjuction with his experiments on the Saine River and the Courpalet Canal in 1769. The quantity C, called the Chezy coefficient, varies about 60 ft½ /s for small rough channels to 160 ft½ /s for large smooth channels (30 m½ /s to 90 m½ /s in SI units).
  • 13. EXAMPLE A straight rectangular channel is 6 ft wide and 3 ft deep and laid on a slope of 2°. The friction factor is 0.022. SOLUTION sft108 022.0 2.3288 2 1 = × == f g C 2 ft1836 =×=A ft5.1 363 18 = ++ == WP A Rh °= 2tan0S ( ) ( )( ) ( )( ) /sft4502tan5.118108 3 2 1 2 1 0 =°×=⋅= SRCAQ h For SI units, it can be used directly.
  • 14. Uniform steady flow and Manning’s equation When discharge remain the same and depth does not change, then we have uniform steady flow. In this condition, the surface of water is parallel to the bed of the channel. To make sure water (liquid) flow inside the channel, it must have certain angle of inclination, or the channel’s slope. The slope of the channel (S) can be expressed as :- • An angle = 1 degree • As percent = 1% • As fraction = 0.01 or 1 in 100
  • 15. Manning’s equation is used to estimate the velocity of flow in a channel. The SI units form of Manning’s equation:- 2 1 3 2 0.1 SR n V ⋅⋅= V = Velocity of flow in a channel (m/s) n = Channel surface roughness. Values developed through experimentation. R = Hydraulic radius (A/WP) in meter S = Slope of the channel The English units form of Manning’s equation:- 2 1 3 2 49.1 SR n V ⋅⋅= V = Velocity of flow in a channel (ft/s) R = Hydraulic radius (A/WP) in feet
  • 16. Example of the n values:-
  • 17. The flowrate of a channel could be determined by :- 2 1 3 2 0.1 SAR n AVQ ⋅⋅== where Q is in m3 /s. For uniform flow, Q is referred to as normal discharge. The above equation can also be re-arranged such that :- 2 1 3 2 S nQ AR = The left hand side equation is based on channel geometry.
  • 18. Example #01 Determine normal discharge for a 200 mm inside diameter common clay drainage tile running half-full if the slope drops 1m over 1000m. 2 1 3 2 0.1 SAR n Q ⋅⋅= 013.0=n 2 2 m0157.0 42 1 =×= D A π m3142.0 2 1 perimeter,Wetted =×= DWP π m05.0 3142.0 0157.0 === WP A R 001.0=S /sm1018.5 0.1 332 1 3 2 − ×=⋅⋅= SAR n Q
  • 19. Example #02 Calculate slope of channel if normal discharge is 50 ft3 /s. Channel is formed, unfinished concrete. English unit !!! 2 1 3 2 49.1 SAR n Q ⋅⋅= → 3 2 2 1 49.1 AR Qn S = 017.0 ft24.1 WP A R ft66.9 ft12 2 = == = = n WP A 00169.0=S (Channel should drop 1.69 feet for every 1000 feet length.
  • 20. Example #03 Design a rectangular channel in formed, unfinished concrete with below mention specifications. Normal flowrate = 5.75 m3 /s S = 1.2% Normal depth = half of the width of the channel. Since we have to design the channel, use this equation. 2 1 3 2 S nQ AR = Y=B/2 B ( ) 892.0 012.0 75.5017.0 2 1 2 1 3 2 = × == S nQ AR 22 2 BB BBYA =×== BYBWP 22 =+= 4 B WP A R == 892.0 42 3 2 2 3 2 =⎟ ⎠ ⎞ ⎜ ⎝ ⎛ ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ = BB AR m88.0 m76.1 = = Y B
  • 21. Example #04 In a rectangular channel as mention in Example #03, the final width was set at 2m and the maximum discharge is 12m3 /s. Find the normal depth for this maximum discharge. 2 1 3 2 S nQ AR = Y=B/2 2 ( ) 862257.1 012.0 12017.0 2 1 2 1 3 2 = × == S nQ AR YA 2= YWP 22 += Y Y WP A R 22 2 + == ( ) 862257.1 22 2 2 3 2 3 2 =⎟ ⎠ ⎞ ⎜ ⎝ ⎛ + = Y Y YAR Cannot solve directly. Use trial and error method. Can use MS Excel datasheet. From Excel, The normal depth must be 1.348 meter.
  • 22. From MS Excel worksheet:
  • 23. CONVEYANCE AND MOST EFFICIENT CHANNEL SHAPES 2 1 3 2 0.1 SAR n Q ⋅⋅= Other than the S term, all other terms are related to channel cross section and its features. These terms together are referred to as the Conveyance (K) of the channel. 3 2 0.1 AR n K ⋅= Then, 2 1 SKQ ⋅= WP A R = K is maximum when wetted perimeter (WP) is the least for a give area. This is also the most efficience cross section for conveying flow. For circular section, half full flow is the most efficient.
  • 24.
  • 25. COMPOUND SECTIONS It is occurs when channel shape changes with flow depth. It is a typical idea in natural stream sections during flooding. At normal condition, water flows in the main channel. During floods, water spills over the flood plain. We need to know the flowrate, Q at various depths or vice-versa. So that we could design channels or determine channel safety for various flood magnitudes.
  • 26. Example #05 Channel type: Natural channel with levees. Slope: 0.00015 Determine the normal discharge, Q for depth 3 ft and 6 ft.
  • 27.
  • 28. COMPOUND SECTION This is more realistic situation, where the channel roughness (value of n) may be different for floodplain than the main channel. In this case, we need to determine velocity for each sub-section, and then sum up the discharges for the sections. Example #06 Slope: 0.5% n for bank = 0.06 n for main channel = 0.03 Calculate discharge for depth of 8 feet?
  • 29. 50051003 4008502 3204801 =×= =×= =×= A A A 10551003 5735042 844801 =+= =++= =+= P P P ∑= = ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ = n i ii i i i i VAQ S P A n V 1 2 13 2 49.1 ( )( ) ( ) ( ) ( ) /sft9010 06.0 500105/500 03.0 40057/400 06.0 32084/320 005.049.1 2 3 2 3 2 3 2 2 1 = ⎥ ⎥ ⎦ ⎤ ⎢ ⎢ ⎣ ⎡ × + × + × = Q Q
  • 30. ENERGY PRINCIPLES FOR OPEN CHANNEL FLOW Energy at particular point in the channel is potential energy and kinetic energy. Specific energy: 2 22 22 gA Q y g V yE +=+= areaflowsectionalCross Discharge Velocity flowofDepth = = = = A Q V y Total energy: 2 22 22 gA Q zy g V zyE ++=++= datumthefrombottomchanneltheofHeight=z
  • 31. Example: Rectangular channel width = 2 m Depth = 1 m Q = 4.0 m3/s 2 m 1 m 2 m Height above datum = 2 m Determine the specific energy and total energy. Specific energy: ( )( )( ) m20.1 281.92 4 1 2 2 22 =+=+= g V yE Datum Total energy: E = datum height + specific energy = 2.0 + 1.2 = 3.2 m
  • 32. Specific energy diagram The specific energy can be plotted graphically as a function of depth of flow. k s E gA Q Ey gA Q y g V yE energy,Kinetic 2 energy)(potentialenergy,Static 22 2 2 2 22 = = +=+= Relationship between y and static energy, Es
  • 33. Relationship between y and kinetic energy, Ek 2 2 2gA Q Ek = For a rectangular channel; Substitute Q with specific discharge (discharge per unit width), B Q q = Substitute area, A with, yBA ⋅= 2 2 2 2 22 gy q gA Q Ek ==
  • 34. EXAMPLE A rectangular channel, width is 4 m, flowrate is 12 m3 /s and depth of flow is 2.5 m. Draw specific energy diagram Find critical and alternate depth? 2 2 2 2 2 2 gy q yE gA Q yE += += /sm3 4 12 2 === B Q q
  • 35. 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 0 1 2 3 4 5 6 Energy y static E = y kinetic E total E
  • 37. 1. The diagram applies for a given cross section and discharge. 2. As the depth of flow increases, the static energy increases, and the kinetic energy decreases 3. The total energy curve approaches the static energy curve for high depths and the kinetic energy curve for small depths 4. The specific energy is minimum (Emin) for a particular depth – this depth happens to be the critical depth – Depth for which the Froude’s number = 1.0. velocity = Vc. 5. Emin – only energy value with a singular depth! 6. Depths less than the critical depths – supercritical flow. Froude Number > 1.0. V > Vc. 7. Depths greater than the critical depths – subcritical flow. Froude Number < 1.0. V < Vc. 8. For all other energy values – there are two depth associated – one greater than the critical depth and one less than the critical depth. 9. The two depths associated with the same energy values are referred to as – Alternate depths 10. As discharge increases, the specific energy curves move to the upper right portion of the chart.
  • 38.
  • 39. 2 2 2 2 2 2 gy q yE gA Q yE += += There is a minimum value of E at a certain value of y called the critical depth. 3 2 2 2 10 gy q dy dE −== It shows that Emin occurs at yc 3 1 2 23 1 2 ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ =⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ = gb Q g q yc The associated minimum energy is ; ( ) cc yyEE 2 3 min == The depth, yc corresponds to channel velocity equal to the shallow-water wave propagation speed, C0. gy V Fr = ( ) 22232 ccccc yVygygyq ===
  • 40. By comparison it follows that the critical channel velocity is: ( ) 0 2 1 CgyV cc == 1=Fr For , no solution exists.minEE < For , two solutions are possible:minEE > (1) Large depth with cVV < , called sub-critical. (2) Small depth with , called super-critical.cVV > In sub-critical flow, disturbances can propagate upstream because wave speed .VC >0 In super-critical flow, waves are swept downstream: Upstream is a zone of silence, and a small obstruction in the flow will create a wedge-shape wave exactly analogous to the Mach waves. The angle of these waves must be: ( ) V gy V C 2 1 101 sinsin −− ==μ The wave angle and the depth can thus be used as a simple measurement of super-critical flow velocity.
  • 41.
  • 42. Critical depth, yc m971.0 81.9 3 3 1 23 1 2 =⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ =⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ = g q yc Minimum specific energy, Emin ( ) m457.1971.0 2 3 2 3 min === cyE Since given depth was 2.5 m > 0.971 m, the given depth is sub-critical and the other depth should be super-critical. Now, determining alternate depths (Energy at 2.5 m) m57.2 5.281.92 3 5.2 2 2 2 2 2 = ×× +=+= gy q yE This energy value is the same for the other alternate (super-critical) depth, so; 2 2 81.92 3 57.2 y y ×× += Determine value of y by trial and error method. (use Excel ok)
  • 44.
  • 45. HYDRAULIC JUMP In open channel flow a supercritical flow can change quickly back to a subcritical flow by passing through a hydraulic jump The upstream flow is fast and shallow. The downstream flow is slow and deep. The hydraulic jump is quite thick, ranging in length from 4 to 6 time the downstream depth. It is very important that such jumps be located on specially designed aprons; otherwise the channel bottom will be badly scoured by the agitation. Jumps also mixed fluids very effectively and have application to sewage and water treatment designs.