Project GoalProject Goal
The goal of our project is to save livesThe goal of our project is to save lives
by speeding up medical response toby speeding up medical response to
persons in need. By creating apersons in need. By creating a
relatively inexpensive, wireless homerelatively inexpensive, wireless home
monitoring system, we hope to add amonitoring system, we hope to add a
new dimension to health care.new dimension to health care.
3. 3
Project ImplementationProject Implementation
Create a compact low cost biotelemetry unitCreate a compact low cost biotelemetry unit
that will monitor patient’s blood pressure,that will monitor patient’s blood pressure,
heart rate and temperatureheart rate and temperature
Transmit patient data wirelessly for evaluationTransmit patient data wirelessly for evaluation
at local PCat local PC
LabVIEW to display real time patient data andLabVIEW to display real time patient data and
evaluate data for emergency situationevaluate data for emergency situation
6. 6
Reasons for Rejecting TonometerReasons for Rejecting Tonometer
Precision manufacturing requiredPrecision manufacturing required
Lack of available design informationLack of available design information
Time constraintsTime constraints
7. 7
Electrocardiogram (ECG)Electrocardiogram (ECG)
Chosen as replacement for bloodChosen as replacement for blood
pressure sensorpressure sensor
Allows measurement of patient’s pulseAllows measurement of patient’s pulse
Can be further expanded for accurateCan be further expanded for accurate
cardiac diagnosticscardiac diagnostics
8. 8
ECG CircuitECG Circuit
Three electrodes used to obtain signalThree electrodes used to obtain signal
- Left arm, Right Arm (Signal)- Left arm, Right Arm (Signal)
- Right Chest (Ground)- Right Chest (Ground)
Amplitude of ECG signal is a few millivoltsAmplitude of ECG signal is a few millivolts
Differential amplifier used to measureDifferential amplifier used to measure
changes in biopotentials sent throughchanges in biopotentials sent through
electrodeselectrodes
Non-inverting amplifier used to further amplifyNon-inverting amplifier used to further amplify
signal to a few voltssignal to a few volts
12. 12
Temperature SensorTemperature Sensor
Contact device desired to provide accurateContact device desired to provide accurate
reading of body temperaturereading of body temperature
- supplier could not provide sensor- supplier could not provide sensor
Used ambient sensor to replace contactUsed ambient sensor to replace contact
sensorsensor
- provided acceptable output for testing- provided acceptable output for testing
purposespurposes
- required amplification for improved- required amplification for improved
dynamic accuracydynamic accuracy
13. 13
ScalabilityScalability
Easily expandable for more sensoryEasily expandable for more sensory
inputsinputs
- add A/D converter- add A/D converter
- add few lines of code to Basic Stamp- add few lines of code to Basic Stamp
14. 14
Data Conversion and TransmissionData Conversion and Transmission
Analog to Digital ConverterAnalog to Digital Converter
Basic Stamp 2Basic Stamp 2
Transmitter and ReceiverTransmitter and Receiver
TTL to RS-232TTL to RS-232
15. 15
A/D converterA/D converter
Sensors output analog signals whichSensors output analog signals which
need to be converted to digital signalsneed to be converted to digital signals
8-bit conversion maps 0-5 Volts to a8-bit conversion maps 0-5 Volts to a
byte representing 0 to 255byte representing 0 to 255
A/D selected by Basic Stamp andA/D selected by Basic Stamp and
outputs serial TTLoutputs serial TTL
16. 16
Basic Stamp 2Basic Stamp 2
Used to combine multiple sensor outputs inUsed to combine multiple sensor outputs in
order to transmit on one frequencyorder to transmit on one frequency
Alternates between sensors’ digital signalsAlternates between sensors’ digital signals
and sends them into the transmitterand sends them into the transmitter
Provides a clock and enable signals for A/DProvides a clock and enable signals for A/D
convertersconverters
Adds delimiters to make it easier to separateAdds delimiters to make it easier to separate
and analyze data in LabVIEWand analyze data in LabVIEW
17. 17
TransceiverTransceiver
Decision on transceiver typeDecision on transceiver type
- Motorola MC13176- Motorola MC13176
vs.vs.
Linx ModulesLinx Modules
- Factors- Factors
complexity of transceivercomplexity of transceiver
compactness of unitcompactness of unit
19. 19
LINX modulesLINX modules
Easy to implement transmitter andEasy to implement transmitter and
receiverreceiver
Does not require extensive externalDoes not require extensive external
circuitrycircuitry
Transmits digital dataTransmits digital data
20. 20
ReceiverReceiver
Meets design specifications forMeets design specifications for
receiving data up to 30 feetreceiving data up to 30 feet
Use MAX232 to convert data for serialUse MAX232 to convert data for serial
input into PCinput into PC
Make serial connection to PCMake serial connection to PC
24. 24
LabVIEWLabVIEW
Used to display and analyze dataUsed to display and analyze data
Suitable for serial port applicationsSuitable for serial port applications
Provides user with interactive displayProvides user with interactive display
Ease of programmingEase of programming
25. 25
Importing DataImporting Data
Data acquired through serial portData acquired through serial port
- serial port read program available in- serial port read program available in
LabVIEWLabVIEW
Used delimiters to separate two signalsUsed delimiters to separate two signals
for processingfor processing
Sampling rate limited by A/D convertersSampling rate limited by A/D converters
26. 26
Processing DataProcessing Data
Obtaining heart rate from simulatedObtaining heart rate from simulated
ECG using function generatorECG using function generator
Converting temperature data to degreesConverting temperature data to degrees
FahrenheitFahrenheit
Comparing data to predeterminedComparing data to predetermined
thresholds set by user (physician)thresholds set by user (physician)
27. 27
DisplayDisplay
Waveforms and data displayed inWaveforms and data displayed in
real-timereal-time
Front panel indicators show when vitalFront panel indicators show when vital
signs reach thresholdssigns reach thresholds
Call for medical attention made whenCall for medical attention made when
thresholds reachedthresholds reached
29. 29
Problems and ChallengesProblems and Challenges
Building blood pressure unitBuilding blood pressure unit
Obtaining proper temperature sensorObtaining proper temperature sensor
LINX module transmitting at fixedLINX module transmitting at fixed
frequencyfrequency
Importing ECG data to LabVIEWImporting ECG data to LabVIEW
Noise in bench supply voltagesNoise in bench supply voltages
30. 30
ImprovementsImprovements
Contact temperature sensorContact temperature sensor
Better A/D’sBetter A/D’s
Housing for circuitHousing for circuit
Data Acquisition Card for LabVIEWData Acquisition Card for LabVIEW
Open communications channel for helpOpen communications channel for help
31. 31
PossibilitiesPossibilities
Integrate GPSIntegrate GPS
Compact and comfortableCompact and comfortable
Expanded analytical capabilitiesExpanded analytical capabilities
Display on telemetry unitDisplay on telemetry unit
Dispense medicationDispense medication
34. 34
ThanksThanks
We’d like to express our appreciation toWe’d like to express our appreciation to
Dr. Thomas Ferrell of Oak RidgeDr. Thomas Ferrell of Oak Ridge
National Laboratories, Shao Hsia, LeeNational Laboratories, Shao Hsia, Lee
Rumsey, and Prof Andrew Webb forRumsey, and Prof Andrew Webb for
their contributions to the success of ourtheir contributions to the success of our
project.project.
35. 35
ConclusionConclusion
We feel this is the future of health careWe feel this is the future of health care
in a system of rising costs and patientin a system of rising costs and patient
volume. It provides more efficientvolume. It provides more efficient
means of monitoring patients as well asmeans of monitoring patients as well as
providing the patient with peace of mindproviding the patient with peace of mind
without being restricted to a hospitalwithout being restricted to a hospital
bed.bed.