Problem: Filter is not cleaning properly
• Check the hoppers
– Make sure hopper has been emptied and valves are
discharging properly
• Search for presence of moisture
– Excess moisture in the compressed air stream will plug
bags and shorten bag life
• Check the operation of the timer
– Check the LED lights on the circuit board and listen for
pulses
– Consult timer manual
Filter is not cleaning properly (cont.)
• Inspect solenoid valves
– Defective valves must be replaced
• Consider condensation
– Condensation from high humidity ventilation air
can plug bags
• Consider installing exterior insulation for dust collector
and ducts
Problem: The dust collector is operating at a
low volume
• Clean plugged filter bags
– Filters should be cleaned in an off-line mode with
the fan turned off for at least 15 minutes
• Evaluate exhaust fan performance
– Check belts, fan rotation, inlet, and inlet design
– Correct problems and re-test fan for flow and
pressure drop
The dust collector is operating at a
low volume (cont.)
• Inspect inlet ducts
– Are inlet ducts
• Plugged?
• Too small?
• Running too long?
• Causing excessive pressure drop due to improper
fittings?
Problem: The dust collector is
operating at a high volume
• Adjust fan speed
– High speeds pull too much air and product
through the system
• Check filter bags
– Any missing or damaged filter bags create a lower
system static loss
– Leads to heavier dust emissions
– Replace and repair bags
Problem: The dust collector is
operating at a high volume
• Make sure inlet ducts are secure and properly
sized
– Check the ductwork static pressure to ensure the
system pressure drop is per the design conditions
– Modify ductwork as needed
– Check ductwork for leaks to be plugged
– Install blast gates to fine tune the CFM at a specific
ventilation point
– Think of this process as “dust control”
rather than “dust collection
Problem: The dust collector is
experiencing excessive dust leakage
• Double check filter bags
– Make sure filter bags are installed properly
• Inspect clean air plenum for leaks
– Visually inspect to find leaks
– If leaks are not visible, use a dye test kit to
determine leak locations
• Remember
– A faulty collector can lead to a shut-down with
costly downtime and airborne dust can threaten
employee health and safety.
– For replacement parts, questions, or general
inquiries, call Sly Inc. at (866) 721-3545 or e-mail
us at info@slyinc.com and we will assist you in
troubleshooting your dust collector problems.
DUST COLLECTOR
TROUBLESHOOTING
www.slyinc.com
866-721-3545
sales@slyinc.com
/SlyIncorporatedStrongsville
@tweetslyinc
/company/sly-incorporated
/SlyIncorporatedStrongsville

More Related Content

Viewers also liked

Automatic drainage cleaning system
Automatic drainage cleaning systemAutomatic drainage cleaning system
Automatic drainage cleaning systemSelf-employed
 
DESIGN OF SUBSURFACE DRAINAGE SYSTEM
DESIGN OF SUBSURFACE DRAINAGE SYSTEMDESIGN OF SUBSURFACE DRAINAGE SYSTEM
DESIGN OF SUBSURFACE DRAINAGE SYSTEMNamitha M R
 
Drainage presentation
Drainage presentationDrainage presentation
Drainage presentationBilly Wiggins
 
Drainage system
Drainage systemDrainage system
Drainage systemAditi Shah
 
Nowe normy kontroli w instytucjach finansowych
Nowe normy kontroli w instytucjach finansowychNowe normy kontroli w instytucjach finansowych
Nowe normy kontroli w instytucjach finansowychKatarzyna Lamczyk
 
BVPresentation
BVPresentationBVPresentation
BVPresentationBen Arditi
 
Developing Breakout Models in FEMAP (Includes Tutorial Walk-throughs)
Developing Breakout Models in FEMAP (Includes Tutorial Walk-throughs)Developing Breakout Models in FEMAP (Includes Tutorial Walk-throughs)
Developing Breakout Models in FEMAP (Includes Tutorial Walk-throughs)Aswin John
 
Flick Film FestivalInternship
Flick Film FestivalInternshipFlick Film FestivalInternship
Flick Film FestivalInternshipKayla Kehler
 
Dávila gómez presentaciónfinal
Dávila gómez presentaciónfinalDávila gómez presentaciónfinal
Dávila gómez presentaciónfinalAndrea Corina Dávila
 
Antibiotic Resistance
Antibiotic ResistanceAntibiotic Resistance
Antibiotic ResistanceNIJEESH CH
 

Viewers also liked (14)

Automatic drainage cleaning system
Automatic drainage cleaning systemAutomatic drainage cleaning system
Automatic drainage cleaning system
 
Particle Technology- Centrifugal Separation
Particle Technology- Centrifugal SeparationParticle Technology- Centrifugal Separation
Particle Technology- Centrifugal Separation
 
DESIGN OF SUBSURFACE DRAINAGE SYSTEM
DESIGN OF SUBSURFACE DRAINAGE SYSTEMDESIGN OF SUBSURFACE DRAINAGE SYSTEM
DESIGN OF SUBSURFACE DRAINAGE SYSTEM
 
Drainage presentation
Drainage presentationDrainage presentation
Drainage presentation
 
Drainage system
Drainage systemDrainage system
Drainage system
 
Automatic irrigation system ppt
Automatic irrigation system pptAutomatic irrigation system ppt
Automatic irrigation system ppt
 
Nowe normy kontroli w instytucjach finansowych
Nowe normy kontroli w instytucjach finansowychNowe normy kontroli w instytucjach finansowych
Nowe normy kontroli w instytucjach finansowych
 
BVPresentation
BVPresentationBVPresentation
BVPresentation
 
Tune TVi
Tune TViTune TVi
Tune TVi
 
Developing Breakout Models in FEMAP (Includes Tutorial Walk-throughs)
Developing Breakout Models in FEMAP (Includes Tutorial Walk-throughs)Developing Breakout Models in FEMAP (Includes Tutorial Walk-throughs)
Developing Breakout Models in FEMAP (Includes Tutorial Walk-throughs)
 
Flick Film FestivalInternship
Flick Film FestivalInternshipFlick Film FestivalInternship
Flick Film FestivalInternship
 
Dávila gómez presentaciónfinal
Dávila gómez presentaciónfinalDávila gómez presentaciónfinal
Dávila gómez presentaciónfinal
 
Antibiotic Resistance
Antibiotic ResistanceAntibiotic Resistance
Antibiotic Resistance
 
b_p_T_M_New
b_p_T_M_Newb_p_T_M_New
b_p_T_M_New
 

Recently uploaded

08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking MenDelhi Call girls
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationRidwan Fadjar
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Allon Mureinik
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsEnterprise Knowledge
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slidespraypatel2
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonetsnaman860154
 
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure serviceWhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure servicePooja Nehwal
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Paola De la Torre
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Patryk Bandurski
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsMark Billinghurst
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking MenDelhi Call girls
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptxHampshireHUG
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machinePadma Pradeep
 
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmatics
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmaticsKotlin Multiplatform & Compose Multiplatform - Starter kit for pragmatics
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmaticscarlostorres15106
 
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersThousandEyes
 

Recently uploaded (20)

08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 Presentation
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI Solutions
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slides
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure serviceWhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
WhatsApp 9892124323 ✓Call Girls In Kalyan ( Mumbai ) secure service
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR Systems
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machine
 
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmatics
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmaticsKotlin Multiplatform & Compose Multiplatform - Starter kit for pragmatics
Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmatics
 
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
 

Dust Collector Troubleshooting

  • 2. Problem: Filter is not cleaning properly • Check the hoppers – Make sure hopper has been emptied and valves are discharging properly • Search for presence of moisture – Excess moisture in the compressed air stream will plug bags and shorten bag life • Check the operation of the timer – Check the LED lights on the circuit board and listen for pulses – Consult timer manual
  • 3. Filter is not cleaning properly (cont.) • Inspect solenoid valves – Defective valves must be replaced • Consider condensation – Condensation from high humidity ventilation air can plug bags • Consider installing exterior insulation for dust collector and ducts
  • 4. Problem: The dust collector is operating at a low volume • Clean plugged filter bags – Filters should be cleaned in an off-line mode with the fan turned off for at least 15 minutes • Evaluate exhaust fan performance – Check belts, fan rotation, inlet, and inlet design – Correct problems and re-test fan for flow and pressure drop
  • 5. The dust collector is operating at a low volume (cont.) • Inspect inlet ducts – Are inlet ducts • Plugged? • Too small? • Running too long? • Causing excessive pressure drop due to improper fittings?
  • 6. Problem: The dust collector is operating at a high volume • Adjust fan speed – High speeds pull too much air and product through the system • Check filter bags – Any missing or damaged filter bags create a lower system static loss – Leads to heavier dust emissions – Replace and repair bags
  • 7. Problem: The dust collector is operating at a high volume • Make sure inlet ducts are secure and properly sized – Check the ductwork static pressure to ensure the system pressure drop is per the design conditions – Modify ductwork as needed – Check ductwork for leaks to be plugged – Install blast gates to fine tune the CFM at a specific ventilation point – Think of this process as “dust control” rather than “dust collection
  • 8. Problem: The dust collector is experiencing excessive dust leakage • Double check filter bags – Make sure filter bags are installed properly • Inspect clean air plenum for leaks – Visually inspect to find leaks – If leaks are not visible, use a dye test kit to determine leak locations
  • 9. • Remember – A faulty collector can lead to a shut-down with costly downtime and airborne dust can threaten employee health and safety. – For replacement parts, questions, or general inquiries, call Sly Inc. at (866) 721-3545 or e-mail us at info@slyinc.com and we will assist you in troubleshooting your dust collector problems.

Editor's Notes

  1. Check the hoppers A hopper, located in the lower portion of the dust collector, should be checked and emptied when troubleshooting a dust collector. If you don’t have a rotary valve in the hopper of your collector, make sure that the hoppers have been emptied on a regular basis. Additionally, if you do have a rotary valve, check the hopper to ensure the valve is discharging properly and material is not plugging the collector. Full hoppers may promote re-entrance of dust into the air stream, thus drastically increasing the dust load and potentially overload the dust collector. Remember, Sly offers hopper flow enhancement designs to prevent this sort of blockage. Call our Aftermarket Parts Department for more information on helpful features and accessories like poke holes, vibrators, fluidizers, level sensors, heaters, and even sonic horns. Search for presence of moisture Excess moisture in the compressed air stream will cause plugging of the bags and may result in improper cleaning and shortened bag life. This moisture should be combated with compressed air dryers. Additionally, search for any oil leaks, as airborne oil from air compressors can also cause the bags to plug and interrupt the dust collection system. Check the operation of the timer When checking the timer, observe the LED lights on the circuit board for timer operation. Check the LED’s visually and listen for pulses. Consult the timer manual for details on setting the timer’s pulse duration and frequency of cleaning. For further information, call Sly at 800-334-2957.
  2. Inspect solenoid valves Defective solenoid valves can result in failure of the pulse valves to operate properly or at all. To replace these defective valves, contact our Aftermarket Department and we will find the appropriate replacement. Consider condensation Any condensation of water from high humidity ventilation air entering a cool duct or dust collector can cause the bags to plug. Plugged bags will likely need to be replaced as soon as possible to prevent further problems. Exterior insulation for the dust collector and ducts should be considered.
  3. Problem: The dust collector is operating at a low volume. Collectors operating at a low volume will pick up an insufficient amount of dust, costing the plant valuable time and money.  A low air volume may be due to several factors.  Troubleshoot this with the following procedures. Clean plugged filter bags Improper cleaning of filter bags leads to high pressure drop that inevitably leads to a reduced air volume. The filters should be cleaned in an off-line mode, with the fan turned off, for at least 15 minutes.  After this time, start the unit up again. If the pressure drop is still high the filters will need to be replaced. Evaluate exhaust fan performance A number of issues could potentially affect the performance of an exhaust fan. Belts may be slipping, rotation of the fan may be incorrect, the inlet or impeller may be in poor condition, or there may be an improper pressure drop due to a poor inlet design for the ductwork. Any specific problems that are found should be corrected and the fan re-tested for flow and pressure drop.
  4. Inspect inlet ducts If the inlet ducts are plugged, too small, run too long, or cause an excessive pressure drop due to improper connections or fittings, the system air flow will be affected.  Ductwork should be periodically inspected and any specific problems corrected as soon as possible. NOTE:     If a fan damper is supplied, the damper should be closed halfway before startup with a new bag.  Once the pressure drop across the bags has reached approximately 2” w.c., the damper may be opened until the unit is at design volume.  This is best determined by taking a pitot tube traverse of the inlet or outlet duct of the collector.  Any air velocity measuring devices may be used.
  5.   Problem: The dust collector is operating at high volume and picking up excessive product. Collectors operating at excessive volume will pick up too much product, potentially over-working the dust collector and removing valued product from the process. Removing more than just the undesired airborne dust can cost the plant valuable time and money. Troubleshoot as follows: Adjust fan speed If the fan is running at a speed that is higher than design then it will pull too much air through the system causing the pick-up points to draw in excess product.  Check the fan speed and change sheaves/pulleys if needed to bring the speed to design conditions. Check filter bags Any missing or damaged filter bags will create a lower system static loss that can lead to higher conveying air volumes (based on fan curves). The greater problem here is not “excessive product pick-up” at the dust source but heavier dust emissions. Refer to the next section for troubleshooting recommendations.
  6. Make sure inlet ducts are secure and properly sized Inlet ducts that are larger than required and not appropriately customized can lead to lower system static loss, which can lead to higher air flow. Check the ductwork static pressure at several locations and across the fan to verify the system pressure drop is per the design conditions.  Modify the fan or the ductwork to ensure proper pickup volumes and ductwork velocities to prevent powder from settling in the ducting. However, before making any adjustments in the ductwork, check for leaks though flanges, access ports or holes and correct those conditions before taking any measurements. Leaking ductwork will usually mean less available air at the pickup locations and lack of adequate venting of dust in that location. Any non-essential openings should be plugged and any ducting leaks patched to ensure only the appropriate pickup locations are connected to the system. Once this is done, the current operating volumes and static pressures should be measured throughout the system and include the total readings at the exhaust fan. Then compare these measurements to the initial start-up bench marks and design of the ductwork.  Once these values are known, exhaust air at each pick-up point can be controlled with a blast gate. The blast gates serve to fine tune the amount of air volume (CFM) at the specific ventilation point. If you are concerned about picking up too much product, then the blast gate can be adjusted to a more closed-off position, which creates additional static resistance and decreases CFM. Keep in mind, a reduction in air volume also means the duct velocity will decrease. Care should be taken to make sure the velocity does not drop below the recommended velocity required to transport the dust to the dust collector. Low velocities will cause the dust to drop out in the ductwork which can lead to serious ventilation problems and safety issues when the ductwork fills with material. The hood design should also be observed for velocities that are too high, allowing pick up of more dust. Thinking about this process as “dust control” and not “dust collection” may help put it into perspective.  For example, a pick-up point should have a hood or transition which keeps the pick-up velocity low as compared to the high-velocity transport in the ductwork. These values will vary dependent on the application and type of dust involved.
  7. Problem: The dust collector is experiencing excessive dust leakage. This problem is similar to excessive product pickup, but is unrelated to collector volume conditions. Instead, troubleshoot dust leakage as follows: Double check filter bags A clean air plenum, located at the top of the tubesheets. The plenum should be inspected for leaks when troubleshooting a dust collector. If excessive dust leakage is occurring, first check to make sure the filter bags are installed properly. Any improperly installed filters should be reinstalled.  Look for telltale signs of dust on the tubesheet around the faulty filters. Inspect clean-air-plenum for leaks Visually inspect the clean-air-plenum to find the source of the dust leak.  If you cannot determine the source of the leak, fluorescent powders are available which glow under black light. In a dye test, a quantity of the fluorescent powder is introduced into the inlet of the collector with the fan running and the cleaning system off.  Use approximately 1/2 pound of powder per 1,000 square feet of media. Next, the fan should be turned off and the clean-air-plenum inspected with the black light.  The leak point will glow a bright fluorescent color that is more apparent in dim or dark surroundings. A leak test kit is available from Sly Inc. Keeping your dust collection equipment in proper operating condition is essential to maintaining compliance with EPA and OSHA regulations as well as maximizing product recovery.  Troubleshooting is a critical part of the overall system operation.  Paying close attention to small changes in the operation becomes key to keeping your system running smoothly in the way it was intended.