Integrating Renewable Energy Generated
Electricity To The Grid
Presentation By: Tejaswi Shukla
www.sterlingwilson.com
Introduction
 Regulatory and Policy Environment in India
 The Solar Generation Perspective
 The Grid Perspective
 Conclusion
 References
www.sterlingwilson.com
Solar Power and the Electric Grid
In today’s electricity generation system, different resources make different contributions to the electricity grid. This fact sheet
illustrates the roles of distributed and centralized renewable energy technologies, particularly solar power, and how they will
contribute to the future electricity system. The advantages of a diversified mix of power generation systems are highlighted.
www.sterlingwilson.com
Grid : How does the Electric Grid work?
The electric grid—an interconnected system —maintains an instantaneous balance between supply and demand (generation
and load) while moving electricity from generation source to customer. Because large amounts of electricity are difficult to
store, the amount generated and fed into the system must be carefully matched to the load to keep the system operating
www.sterlingwilson.com
National Technical Regulations in India:
There are three important regulations by way of which the CEA outlines the technical and safety requirements for
distributed generation;
• The CEA’s ‘Technical Standards for Connectivity of the Distributed Generation Resources’ Regulations, 2013 are
applicable to any solar system that is connected at voltage level below 33kV. The CEA regulations cover the roles and
responsibilities of the developer/ system owner and of the Distribution Company (DISCOM), the equipment standards
and codes of practice for safety, and the system requirements for safe voltage, frequency, harmonics, etc.
• The CEA’s ‘Installation and Operation of Meters’ Regulation 2006 (draft amendment in 2013 includes distributed solar
generation) regulates metering standards.
• The CEA’s ‘Measures of Safety and Electricity Supply Regulations, 2010 govern safety for generators. The CEA regulation
‘Technical Standards for Connectivity of the Distributed Generation Resources’ mentions that safety standards should
be in accordance to this code. However, these safety codes are aligned more towards large-scale thermal power plants
as opposed to small-distributed solar plants
In addition, states in India have also prescribed some technical requirements for distributed solar PV through government
policies, and regulations brought out by the SERCs.
Regulatory and Policy Environment in
India
www.sterlingwilson.com
COMBINED SUMMARY OF STATE
POLICIES FOR SOLAR POWER
www.sterlingwilson.com
The Solar Generation Perspective
This section of the PPT deals with the standards and regulations around system level components, mainly the inverter and other Balance of
System (BOS) components. It examines the technical regulations, as well as the electrical parameters associated with them. In light of the
corresponding standards in Germany, the U.S. and Australia, the PPT reviews India’s standards, analyses their adequacy and suggests
potential options going forward.
Current regulations – India and Abroad
THD
• Germany adopts the International Electrotechnical Commision (IEC) 61000-3-2 53, 61000-3- 12 54 standards that stipulate equipment
standards for harmonics. These standards are for LV equipment with input current ≤16A (IEC 61000-3-2) and with input current >16A and
≤75A (IEC 61000-3-12).
• The USA adopts the IEEE 519 55 which addresses the limitations for current and voltage harmonic on termination through Individual
Harmonic Limits and Total Harmonic Distortion (THD) limits. The voltage distortion limit established by the standard for general systems is
5% THD. In this standard, the Total Demand Distortion (TDD), determined by the ratio of available short circuit current to the demand
current (Isc/IL), is used as the base number to which the limits are applied. There are specific limits mentioned for various harmonics for
different TDD values. The actual measurement that one takes with a typical harmonic analyser is a snapshot and provides an
instantaneous measurement that is referred to as THD. IEEE does not provide equipment standards like the IEC. continue………..
www.sterlingwilson.com
The Solar Generation Perspective
• In Australia, the AS4777 states that the total harmonic distortion (THD) (to the 50th harmonic) shall be less than 5%.
• India also adopts the IEEE 519 on similar lines of Australia and the USA.
The present harmonics standard in India is adequate and in line with the best global practices. Additionally, the adoption of IEEE 519 is not a
major economic or technical hurdle for the inverter manufacturers to incorporate into their systems.
Flicker
Random or repetitive variations in the root mean square (RMS) voltage between 90% and 110% of nominal voltage can be generated by the
solar system and produce a phenomenon known as ‘flicker’. Flicker is so named because of the rapid, visible change of luminance in lighting
equipment.
DC injection into AC grid
DC current within the low voltage AC network could cause significant disturbances within distribution and measurement transformers. The
most significant being “half cycle saturation”, where a transformer, which normally operates with a very small exciting current, starts to draw as
much as a hundred times the normal current. This results in the transformer operating beyond the design limits. Other effects within
transformers include excessive losses (i.e. overheating) , generation of harmonics, acoustic noise emission, and residual magnetism. In addition,
there is evidence for the seriousness of corrosion risks associated with DC currents in the grid. PV inverters can cause a DC bias due to the
mechanisms: imbalance in state impedances of switches, different switching times for switches, and imperfection in implementing the timing of
drivers .
www.sterlingwilson.com
The Solar Generation Perspective
– Anti-islanding function
Islanding refers to the condition in which a distributed solar system continues to supply to a load even though grid power from
the utility is no longer present. Islanding can be dangerous to utility workers, who may not realise that a circuit is still powered
when working on repairs or maintenance. For that reason, the inverter in the PV systems must detect islanding and stop
supplying power if the grid is down. This feature is referred to as ‘anti-islanding’. The island so formed is known as an
‘unintentional island’. There are two methods to detect an islanding operation: passive and active. Passive techniques are
based on measurement of instantaneous voltage, instantaneous frequency, phase deviations, vector surge relay, and detection
of voltage and current harmonics at the point of interconnection. Passive techniques rely on distinct patterns or signatures at
the point of interconnection to the grid. In the active method, schemes including the voltage shift method, slip mode
frequency shift, active frequency drift (AFD), ENS (impedance measurement), and reactive power fluctuation are employed.
These introduce deliberate changes or disturbances into the connected circuit and then observe the response. On the other
hand, a PV system could disconnect from the grid and continue to supply power to the consumer loads of that particular
building using a battery storage system or in synergy with the diesel backup generator. This is known as an ‘intentional island’.
This feature of the inverter should be explored in India, where there are frequent power outages during the day.
www.sterlingwilson.com
An additional advanced function of special relevance to India (with occasional black/brownouts during the daytime) is
‘intentional islanding’. This feature allows the solar PV system to disconnect from the grid in the event of a grid failure and
continue to supply pre-decided critical consumer loads. This is possible in two ways, (a) the hybrid inverter works in the off-
grid mode, continues to charge batteries which power certain loads or (b) the inverter continues to function in grid-tied mode
in synergy with the larger backup system, most likely diesel based generators. The second option is more feasible for larger
loads, most of which have existing diesel generation backup facilities. Utilities are well versed with such backup facilities,
which already have the required safety features which prevent energising the local grid (reverse flow). Using distributed solar
PV in such an intentional island mode is technically feasible and can also reduce costs compared to costlier diesel generation.
This intentional islanding feature is mentioned as a note in the CEA ‘Installation and Operation of Meters’, 2006 draft
amendment regulation released in 2013, but is omitted in the final CEA ‘Technical standards for connectivity of the distributed
generation resources’, 2013 regulations. The CEA should consider allowing this functionality in the future based on pilot
projects and further studies which should focus on critical issues such as technical specifications for safe automatic isolating
equipment at appropriate locations, challenges around anti-islanding control for multiple distributed generators within a
micro-grid, safety concerns for personnel and legal liabilities with regard to intentional islanding, etc.
The Solar Generation Perspective
– Intentional-islanding function
www.sterlingwilson.com
The Solar Generation Perspective
Reactive Power Support
Reactive power (measured in var) arises due to phase differences between voltage and current in the system. This phase
difference is created by electric and magnetic fields in inductive and capacitive loads (devices that have motors or capacitor
banks).
Utilities in India mandate customers with a high load requirement (industries) to maintain a power factor close to one. A
power factor close to one indicates that the loads are not introducing any reactive power demands on the grid. The demands
are met locally by using devices that provide reactive power. For instance, when a motor needs reactive power, it is not
necessary to go all the way back to electric power generators on the transmission grid to get it. One can simply use a capacitor
bank at the location of the motor and it will provide the required reactive power. This way, consumers have to invest in
additional equipment that will allow them to maintain a power factor close to one. However, not all consumers (residential,
small commercial) are mandated by the utilities to invest in such additional infrastructure. In such cases, there may still remain
a small amount of reactive power demand on the grid and the onus is on utilities to manage this effectively.
www.sterlingwilson.com
The Solar Generation Perspective
Current Regulations - India and abroad
• Germany was the first to mandate reactive power support from inverters through the VDE-AR-N 4105 regulation.
• The USA has not presently mandated the need for reactive power support in line with the interconnection standard, IEEE
1547. However, discussions are in process to implement it in the near future. A recent report on recommendations for
smart inverters has recommended mandating this function in California.
• Australia has also proposed this feature in their new AS4777 standard.
• India does not have a reactive power support regulation for distributed generation at present.
Implications of reactive power support on inverter sizing……………….
Benefits of reactive power support……………….
www.sterlingwilson.com
The Solar Generation Perspective
Low/High Voltage Ride-Through (LHVRT)
Fault Ride-Through (FRT) features enable grid-tied inverters to stay connected to the grid during voltage or frequency
fluctuations of extremely short durations. Low/High Voltage Ride-Through (LHVRT) is one such feature. At the time of a failure
(short-circuit or lightning strike), a high current flows through the grid leading to a momentary voltage sag. This would
typically trigger the inverter to trip and disconnect until the voltage on the grid stabilises. In such instances, inverters tripping
(in a high DG solar penetration scenario) can cause the line voltage to decrease further, which in turn can cause other
inverters on the line to trip. This can result in a “cascading effect” that would ultimately rapidly take down all the inverters
connected to the distribution network. LHVRT allows inverters to stay connected if such voltage excursions are for very short
time durations and the voltage returns to the normal range within a specified time frame. LHVRT does not require the
inverter to stay connected if the fault persists beyond a specified time.
India currently does not require inverters to have the LHVRT functionality. While this is unproblematic at lower penetration
levels, it could be an issue at very high penetration levels.
www.sterlingwilson.com
The Grid Perspective
The Electric Grid of the Future
It is adding various technologies to the already existing grid .It covers technologies from the generation sites all the way to the
consumers
www.sterlingwilson.com
The Grid Perspective
The electrical infrastructure of the future will be much more complex than the current one. It will have to integrate
traditional and sustainable energy sources, present and new distribution systems, storage systems, customers with quite
different consumption patterns, demand response based on market signal, and smart control systems.
The Problem: At this moment there are no comprehensive enough engineering models that can cope with the higher level
of complexity of future electric grids.
Can philosophy offer a solution? Dealing with complexity?
The successful integration of renewable energy sources and implementation of smart grid technologies will require a holistic
analysis and design process.
www.sterlingwilson.com
The Grid Perspective
The level of demand for electricity in any one area is so variable that it is more efficient to combine demand from many sites
into an overall regional load. This regional electric load is then met by the output of a fleet of generators that can be controlled
and managed for optimal performance. In part, the grid was developed to allow generators to provide backup to each other
and share load.
Interconnection with Grid :-
In order to take benefit of large amount of dispersed Renewables, integration is a necessity. Hitherto planned, designed,
constructed, and operated grid meant for haulage of large amount of power from conventional sources has to accommodate
the need of such DGR too. Again to take care of uncertainties in this category of generation resources, means of storage too to
be accommodated. This may not limit
to only pumped storage plant, but also may be battery storage system in conjunction with inverter system for ac grid. It calls
for development of smart or intelligent grid that with the application of extensive information and communication technology
can be operated and controlled. Distribution system so long carrying power in one direction may have to be bi-directional to
carry the power in reverse direction, say,
may be from roof-top solar PV generation from customer with proper metering arrangement. In other words, even there
would be possibility of re-shaping of load curve to the advantage of all stake-holders. Even problem of congestion
management may be easy with the ease in pressure on supply
continue………………
www.sterlingwilson.com
The Grid Perspective
company. However, for this upgrading of grid system is a must. With the active participation of consumers a smart grid
would employ communication and information technology to optimize energy usage from generation including green
energy as well as stored with proper metering. In India with the Distribution system and consequently with the Transmission
system initiative towards achieving the same has been taken.
RE grid integration challenges
Wind and solar generation both experience intermittency, a combination of non-controllable variability and partial
unpredictability, and depend on resources that are location-dependent. These three distinct aspects, explained below, each
create distinct challenges for generation owners and grid operators in integrating wind and solar generation
Non-controllable variability: Wind and solar output varies in a way that generation operators cannot control, because wind
speeds and available sunlight may vary from moment to moment, affecting moment-to-moment power output. This
fluctuation in power output results in the need for additional
energy to balance supply and demand on the grid on an instantaneous basis, as well as ancillary services such as frequency
regulation and voltage support.
www.sterlingwilson.com
The Grid Perspective
Integration of RE:
• Strong interconnection to sustain variability.
• Transmission line capacity as per RE generation
• Strengthen Grid code for RE
• Dynamic control system
• Renewable energy management system
www.sterlingwilson.com
The Grid Perspective
Challenges
 Uncontrolled development of capacity addition
 Very large grid : Means Complexity, Comprising of several type of technology.
 Inadequate T & D
 High share of RE fluctuate power
Solution
 Automation of T & D System
 Smart Grid application
 Renewable energy forecasting
www.sterlingwilson.com
The Grid Perspective
An evaluation of European smart grid projects showed that it is very difficult to grasp technological and non-technological
key characteristics of this complex system: the difficulties encountered during the data collection process; the lack of
quantitative data to perform analyses; the recognition of the higher complexity of the system and the lack of proper
integration; the difficulties with the setting of business models; the lack of consumer involvement; the need for proper ICT
infrastructure; the need for better data protection and security; and the need for a legislative framework to ensure proper
division of responsibility. Specific attention to the social implications of renewable sources and innovation in three basic
areas are necessary:
• Integration of sustainable energy sources;
• Development of smart grids to accommodate production and consumption of energy under market signal incentives;
Development of models to understand the non-technological aspects of the production and consumption of energy, e.g.,
social and ethical questions. In addition, these non-technological aspects have to be integrated in the design of sustainable
sources and smart grids.
www.sterlingwilson.com
Conclusion
Integration of large penetration of renewable energy systems at the transmission level will require a careful evaluation of the
philosophy of the design process.
The design needs to consider the complexity of the new system, and deal with it via an Integrated Design Approach, which
must be:
Integral = all aspects (technologies, social / economic, etc.)
Inclusive = all stakeholders – and consider all
Ideals = values, missions and visions
Significant amounts of storage systems may be required for a normative integration of high penetration of renewables.
When technical and economic opportunities can be created by shifting energy over time periods ranging anywhere from
seconds to days, then electricity storage may have value. Additionally, the power electronics in battery systems may have fast
response and ramp capability and the ability to operate at non-unity power factors, which can be used to change ac voltage.
These characteristics may provide additional opportunities to provide ancillary services, like frequency regulation and voltage
support and needs to be taken into account as part of the planning and operation philosophical strategies
www.sterlingwilson.com
References
• National Renewable Energy Laboratory, http://www.nrel.gov/solar/
• T. Flick and J. Morehouse, Securing the Smart Grid: Next Generation Power Grid Security. Burlington, MA,
USA: Syngress, 2010.
• IEEE – PES (Power and Energy Society ), www.ieee-pes.org
• M. Malinowski, K. Gopakumar, J. Rodriguez and M. A. Perez, “A survey on cascaded multilevel inverters,”
IEEE Trans. Ind. Electron., vol. 57, no. 7, pp. 2197-2206, Jul. 2010
www.sterlingwilson.com
THANK YOU

More Related Content

What's hot

Integration of smart grid with renewable energy
Integration of smart grid with renewable energyIntegration of smart grid with renewable energy
Integration of smart grid with renewable energySAGAR D
 
Reactive power management and voltage control by using statcom
Reactive power management and voltage control by using statcomReactive power management and voltage control by using statcom
Reactive power management and voltage control by using statcomHussain Ali
 
Voltage and Frequency Control of the Grid
Voltage and Frequency Control of the GridVoltage and Frequency Control of the Grid
Voltage and Frequency Control of the GridLeonardo ENERGY
 
Loading Capability Limits of Transmission Lines
Loading Capability Limits of Transmission LinesLoading Capability Limits of Transmission Lines
Loading Capability Limits of Transmission LinesRaja Adapa
 
Fixed and variable speed turbine
Fixed and variable speed turbineFixed and variable speed turbine
Fixed and variable speed turbineSonuKumarBairwa
 
What are Ancillary Services In Power System ?
What are Ancillary Services In Power System ?What are Ancillary Services In Power System ?
What are Ancillary Services In Power System ?Power System Operation
 
Permanent magnet motor drives.pptx
Permanent magnet motor drives.pptxPermanent magnet motor drives.pptx
Permanent magnet motor drives.pptxSuvenduMondal12
 
Island Detection and Control Techniques
Island Detection and Control Techniques Island Detection and Control Techniques
Island Detection and Control Techniques Tanveer Riaz
 
Load forecasting
Load forecastingLoad forecasting
Load forecastingsushrut p
 
Distributed generation b 3
Distributed generation b 3Distributed generation b 3
Distributed generation b 3Naresh Thakur
 

What's hot (20)

Storage In Smart Grids
Storage In Smart GridsStorage In Smart Grids
Storage In Smart Grids
 
Grid Integration of PV
Grid Integration of PVGrid Integration of PV
Grid Integration of PV
 
Integration of smart grid with renewable energy
Integration of smart grid with renewable energyIntegration of smart grid with renewable energy
Integration of smart grid with renewable energy
 
Introduction to Microgrid
Introduction to Microgrid Introduction to Microgrid
Introduction to Microgrid
 
Unit commitment
Unit commitmentUnit commitment
Unit commitment
 
statcom
statcomstatcom
statcom
 
Reactive power management and voltage control by using statcom
Reactive power management and voltage control by using statcomReactive power management and voltage control by using statcom
Reactive power management and voltage control by using statcom
 
Demand Side Management
Demand Side ManagementDemand Side Management
Demand Side Management
 
Voltage and Frequency Control of the Grid
Voltage and Frequency Control of the GridVoltage and Frequency Control of the Grid
Voltage and Frequency Control of the Grid
 
Loading Capability Limits of Transmission Lines
Loading Capability Limits of Transmission LinesLoading Capability Limits of Transmission Lines
Loading Capability Limits of Transmission Lines
 
Fixed and variable speed turbine
Fixed and variable speed turbineFixed and variable speed turbine
Fixed and variable speed turbine
 
POWER SYSTEM OPERATION AND CONTROL
POWER SYSTEM OPERATION AND CONTROLPOWER SYSTEM OPERATION AND CONTROL
POWER SYSTEM OPERATION AND CONTROL
 
What are Ancillary Services In Power System ?
What are Ancillary Services In Power System ?What are Ancillary Services In Power System ?
What are Ancillary Services In Power System ?
 
DFIG ppt.pptx
DFIG ppt.pptxDFIG ppt.pptx
DFIG ppt.pptx
 
Permanent magnet motor drives.pptx
Permanent magnet motor drives.pptxPermanent magnet motor drives.pptx
Permanent magnet motor drives.pptx
 
Island Detection and Control Techniques
Island Detection and Control Techniques Island Detection and Control Techniques
Island Detection and Control Techniques
 
Solar pv connected to grid
Solar pv connected to gridSolar pv connected to grid
Solar pv connected to grid
 
Load forecasting
Load forecastingLoad forecasting
Load forecasting
 
Distributed generation b 3
Distributed generation b 3Distributed generation b 3
Distributed generation b 3
 
Islanding
IslandingIslanding
Islanding
 

Similar to Integration of Renewable Energy In Grid

IRJET- Comparative Analysis of Different Converter Topologies Employed for Tr...
IRJET- Comparative Analysis of Different Converter Topologies Employed for Tr...IRJET- Comparative Analysis of Different Converter Topologies Employed for Tr...
IRJET- Comparative Analysis of Different Converter Topologies Employed for Tr...IRJET Journal
 
Control and Implementation of a Standalone DG-SPV-BES micro-grid System using...
Control and Implementation of a Standalone DG-SPV-BES micro-grid System using...Control and Implementation of a Standalone DG-SPV-BES micro-grid System using...
Control and Implementation of a Standalone DG-SPV-BES micro-grid System using...IRJET Journal
 
Dealing With Reactive Power in Islanded Micro Grid Corresponding Power Distri...
Dealing With Reactive Power in Islanded Micro Grid Corresponding Power Distri...Dealing With Reactive Power in Islanded Micro Grid Corresponding Power Distri...
Dealing With Reactive Power in Islanded Micro Grid Corresponding Power Distri...ijtsrd
 
IRJET- Low Volatge Ride through Solution for Wind Energy Conversion System
IRJET- Low Volatge Ride through Solution for Wind Energy Conversion SystemIRJET- Low Volatge Ride through Solution for Wind Energy Conversion System
IRJET- Low Volatge Ride through Solution for Wind Energy Conversion SystemIRJET Journal
 
IRJET- Renewable Energy Hybrid Power System with Improvement of Power Quality...
IRJET- Renewable Energy Hybrid Power System with Improvement of Power Quality...IRJET- Renewable Energy Hybrid Power System with Improvement of Power Quality...
IRJET- Renewable Energy Hybrid Power System with Improvement of Power Quality...IRJET Journal
 
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...IRJET Journal
 
SWES_Unit-V.ppt
SWES_Unit-V.pptSWES_Unit-V.ppt
SWES_Unit-V.pptGopiPasala
 
An adaptive protection scheme to prevent recloser-fuse miscoordination in dis...
An adaptive protection scheme to prevent recloser-fuse miscoordination in dis...An adaptive protection scheme to prevent recloser-fuse miscoordination in dis...
An adaptive protection scheme to prevent recloser-fuse miscoordination in dis...iosrjce
 
A HYBRID AC/DC SOLAR POWERED STANDALONE SYSTEM WITHOUT INVERTER BASED ON LOAD...
A HYBRID AC/DC SOLAR POWERED STANDALONE SYSTEM WITHOUT INVERTER BASED ON LOAD...A HYBRID AC/DC SOLAR POWERED STANDALONE SYSTEM WITHOUT INVERTER BASED ON LOAD...
A HYBRID AC/DC SOLAR POWERED STANDALONE SYSTEM WITHOUT INVERTER BASED ON LOAD...Iaetsd Iaetsd
 
Presentation by A. K. Bohra on Issues & Challenges in Net Metering
Presentation by A. K. Bohra on Issues & Challenges in Net MeteringPresentation by A. K. Bohra on Issues & Challenges in Net Metering
Presentation by A. K. Bohra on Issues & Challenges in Net MeteringAnil Kumar Bohra
 
OVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTION
OVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTIONOVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTION
OVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTIONIRJET Journal
 
Внедрение распределенной энергетики в систему централизованного энергоснабжен...
Внедрение распределенной энергетики в систему централизованного энергоснабжен...Внедрение распределенной энергетики в систему централизованного энергоснабжен...
Внедрение распределенной энергетики в систему централизованного энергоснабжен...НП "Сообщество потребителей энергии"
 
Advancements in inverter technology
Advancements  in inverter technologyAdvancements  in inverter technology
Advancements in inverter technologyBhanu Teja
 
IRJET- Microgrid State of Charge Sharing and Reactive Power Control
IRJET- Microgrid State of Charge Sharing and Reactive Power ControlIRJET- Microgrid State of Charge Sharing and Reactive Power Control
IRJET- Microgrid State of Charge Sharing and Reactive Power ControlIRJET Journal
 
Frequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable loadFrequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable loadIAEME Publication
 

Similar to Integration of Renewable Energy In Grid (20)

IRJET- Comparative Analysis of Different Converter Topologies Employed for Tr...
IRJET- Comparative Analysis of Different Converter Topologies Employed for Tr...IRJET- Comparative Analysis of Different Converter Topologies Employed for Tr...
IRJET- Comparative Analysis of Different Converter Topologies Employed for Tr...
 
Control and Implementation of a Standalone DG-SPV-BES micro-grid System using...
Control and Implementation of a Standalone DG-SPV-BES micro-grid System using...Control and Implementation of a Standalone DG-SPV-BES micro-grid System using...
Control and Implementation of a Standalone DG-SPV-BES micro-grid System using...
 
Dealing With Reactive Power in Islanded Micro Grid Corresponding Power Distri...
Dealing With Reactive Power in Islanded Micro Grid Corresponding Power Distri...Dealing With Reactive Power in Islanded Micro Grid Corresponding Power Distri...
Dealing With Reactive Power in Islanded Micro Grid Corresponding Power Distri...
 
IRJET- Low Volatge Ride through Solution for Wind Energy Conversion System
IRJET- Low Volatge Ride through Solution for Wind Energy Conversion SystemIRJET- Low Volatge Ride through Solution for Wind Energy Conversion System
IRJET- Low Volatge Ride through Solution for Wind Energy Conversion System
 
IRJET- Renewable Energy Hybrid Power System with Improvement of Power Quality...
IRJET- Renewable Energy Hybrid Power System with Improvement of Power Quality...IRJET- Renewable Energy Hybrid Power System with Improvement of Power Quality...
IRJET- Renewable Energy Hybrid Power System with Improvement of Power Quality...
 
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...
IRJET- Grid Integrated Single Phase PV with Shunt Active Filter based Control...
 
SWES_Unit-V.ppt
SWES_Unit-V.pptSWES_Unit-V.ppt
SWES_Unit-V.ppt
 
An adaptive protection scheme to prevent recloser-fuse miscoordination in dis...
An adaptive protection scheme to prevent recloser-fuse miscoordination in dis...An adaptive protection scheme to prevent recloser-fuse miscoordination in dis...
An adaptive protection scheme to prevent recloser-fuse miscoordination in dis...
 
D010622334
D010622334D010622334
D010622334
 
seminar1.ppt
seminar1.pptseminar1.ppt
seminar1.ppt
 
H011117484
H011117484H011117484
H011117484
 
paper_1.pdf
paper_1.pdfpaper_1.pdf
paper_1.pdf
 
A HYBRID AC/DC SOLAR POWERED STANDALONE SYSTEM WITHOUT INVERTER BASED ON LOAD...
A HYBRID AC/DC SOLAR POWERED STANDALONE SYSTEM WITHOUT INVERTER BASED ON LOAD...A HYBRID AC/DC SOLAR POWERED STANDALONE SYSTEM WITHOUT INVERTER BASED ON LOAD...
A HYBRID AC/DC SOLAR POWERED STANDALONE SYSTEM WITHOUT INVERTER BASED ON LOAD...
 
Presentation by A. K. Bohra on Issues & Challenges in Net Metering
Presentation by A. K. Bohra on Issues & Challenges in Net MeteringPresentation by A. K. Bohra on Issues & Challenges in Net Metering
Presentation by A. K. Bohra on Issues & Challenges in Net Metering
 
OVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTION
OVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTIONOVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTION
OVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTION
 
Внедрение распределенной энергетики в систему централизованного энергоснабжен...
Внедрение распределенной энергетики в систему централизованного энергоснабжен...Внедрение распределенной энергетики в систему централизованного энергоснабжен...
Внедрение распределенной энергетики в систему централизованного энергоснабжен...
 
Advancements in inverter technology
Advancements  in inverter technologyAdvancements  in inverter technology
Advancements in inverter technology
 
IRJET- Microgrid State of Charge Sharing and Reactive Power Control
IRJET- Microgrid State of Charge Sharing and Reactive Power ControlIRJET- Microgrid State of Charge Sharing and Reactive Power Control
IRJET- Microgrid State of Charge Sharing and Reactive Power Control
 
G42022933
G42022933G42022933
G42022933
 
Frequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable loadFrequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable load
 

Integration of Renewable Energy In Grid

  • 1. www.sterlingwilson.com Integrating Renewable Energy Generated Electricity To The Grid Presentation By: Tejaswi Shukla
  • 2. www.sterlingwilson.com Introduction  Regulatory and Policy Environment in India  The Solar Generation Perspective  The Grid Perspective  Conclusion  References
  • 3. www.sterlingwilson.com Solar Power and the Electric Grid In today’s electricity generation system, different resources make different contributions to the electricity grid. This fact sheet illustrates the roles of distributed and centralized renewable energy technologies, particularly solar power, and how they will contribute to the future electricity system. The advantages of a diversified mix of power generation systems are highlighted.
  • 4. www.sterlingwilson.com Grid : How does the Electric Grid work? The electric grid—an interconnected system —maintains an instantaneous balance between supply and demand (generation and load) while moving electricity from generation source to customer. Because large amounts of electricity are difficult to store, the amount generated and fed into the system must be carefully matched to the load to keep the system operating
  • 5. www.sterlingwilson.com National Technical Regulations in India: There are three important regulations by way of which the CEA outlines the technical and safety requirements for distributed generation; • The CEA’s ‘Technical Standards for Connectivity of the Distributed Generation Resources’ Regulations, 2013 are applicable to any solar system that is connected at voltage level below 33kV. The CEA regulations cover the roles and responsibilities of the developer/ system owner and of the Distribution Company (DISCOM), the equipment standards and codes of practice for safety, and the system requirements for safe voltage, frequency, harmonics, etc. • The CEA’s ‘Installation and Operation of Meters’ Regulation 2006 (draft amendment in 2013 includes distributed solar generation) regulates metering standards. • The CEA’s ‘Measures of Safety and Electricity Supply Regulations, 2010 govern safety for generators. The CEA regulation ‘Technical Standards for Connectivity of the Distributed Generation Resources’ mentions that safety standards should be in accordance to this code. However, these safety codes are aligned more towards large-scale thermal power plants as opposed to small-distributed solar plants In addition, states in India have also prescribed some technical requirements for distributed solar PV through government policies, and regulations brought out by the SERCs. Regulatory and Policy Environment in India
  • 6. www.sterlingwilson.com COMBINED SUMMARY OF STATE POLICIES FOR SOLAR POWER
  • 7. www.sterlingwilson.com The Solar Generation Perspective This section of the PPT deals with the standards and regulations around system level components, mainly the inverter and other Balance of System (BOS) components. It examines the technical regulations, as well as the electrical parameters associated with them. In light of the corresponding standards in Germany, the U.S. and Australia, the PPT reviews India’s standards, analyses their adequacy and suggests potential options going forward. Current regulations – India and Abroad THD • Germany adopts the International Electrotechnical Commision (IEC) 61000-3-2 53, 61000-3- 12 54 standards that stipulate equipment standards for harmonics. These standards are for LV equipment with input current ≤16A (IEC 61000-3-2) and with input current >16A and ≤75A (IEC 61000-3-12). • The USA adopts the IEEE 519 55 which addresses the limitations for current and voltage harmonic on termination through Individual Harmonic Limits and Total Harmonic Distortion (THD) limits. The voltage distortion limit established by the standard for general systems is 5% THD. In this standard, the Total Demand Distortion (TDD), determined by the ratio of available short circuit current to the demand current (Isc/IL), is used as the base number to which the limits are applied. There are specific limits mentioned for various harmonics for different TDD values. The actual measurement that one takes with a typical harmonic analyser is a snapshot and provides an instantaneous measurement that is referred to as THD. IEEE does not provide equipment standards like the IEC. continue………..
  • 8. www.sterlingwilson.com The Solar Generation Perspective • In Australia, the AS4777 states that the total harmonic distortion (THD) (to the 50th harmonic) shall be less than 5%. • India also adopts the IEEE 519 on similar lines of Australia and the USA. The present harmonics standard in India is adequate and in line with the best global practices. Additionally, the adoption of IEEE 519 is not a major economic or technical hurdle for the inverter manufacturers to incorporate into their systems. Flicker Random or repetitive variations in the root mean square (RMS) voltage between 90% and 110% of nominal voltage can be generated by the solar system and produce a phenomenon known as ‘flicker’. Flicker is so named because of the rapid, visible change of luminance in lighting equipment. DC injection into AC grid DC current within the low voltage AC network could cause significant disturbances within distribution and measurement transformers. The most significant being “half cycle saturation”, where a transformer, which normally operates with a very small exciting current, starts to draw as much as a hundred times the normal current. This results in the transformer operating beyond the design limits. Other effects within transformers include excessive losses (i.e. overheating) , generation of harmonics, acoustic noise emission, and residual magnetism. In addition, there is evidence for the seriousness of corrosion risks associated with DC currents in the grid. PV inverters can cause a DC bias due to the mechanisms: imbalance in state impedances of switches, different switching times for switches, and imperfection in implementing the timing of drivers .
  • 9. www.sterlingwilson.com The Solar Generation Perspective – Anti-islanding function Islanding refers to the condition in which a distributed solar system continues to supply to a load even though grid power from the utility is no longer present. Islanding can be dangerous to utility workers, who may not realise that a circuit is still powered when working on repairs or maintenance. For that reason, the inverter in the PV systems must detect islanding and stop supplying power if the grid is down. This feature is referred to as ‘anti-islanding’. The island so formed is known as an ‘unintentional island’. There are two methods to detect an islanding operation: passive and active. Passive techniques are based on measurement of instantaneous voltage, instantaneous frequency, phase deviations, vector surge relay, and detection of voltage and current harmonics at the point of interconnection. Passive techniques rely on distinct patterns or signatures at the point of interconnection to the grid. In the active method, schemes including the voltage shift method, slip mode frequency shift, active frequency drift (AFD), ENS (impedance measurement), and reactive power fluctuation are employed. These introduce deliberate changes or disturbances into the connected circuit and then observe the response. On the other hand, a PV system could disconnect from the grid and continue to supply power to the consumer loads of that particular building using a battery storage system or in synergy with the diesel backup generator. This is known as an ‘intentional island’. This feature of the inverter should be explored in India, where there are frequent power outages during the day.
  • 10. www.sterlingwilson.com An additional advanced function of special relevance to India (with occasional black/brownouts during the daytime) is ‘intentional islanding’. This feature allows the solar PV system to disconnect from the grid in the event of a grid failure and continue to supply pre-decided critical consumer loads. This is possible in two ways, (a) the hybrid inverter works in the off- grid mode, continues to charge batteries which power certain loads or (b) the inverter continues to function in grid-tied mode in synergy with the larger backup system, most likely diesel based generators. The second option is more feasible for larger loads, most of which have existing diesel generation backup facilities. Utilities are well versed with such backup facilities, which already have the required safety features which prevent energising the local grid (reverse flow). Using distributed solar PV in such an intentional island mode is technically feasible and can also reduce costs compared to costlier diesel generation. This intentional islanding feature is mentioned as a note in the CEA ‘Installation and Operation of Meters’, 2006 draft amendment regulation released in 2013, but is omitted in the final CEA ‘Technical standards for connectivity of the distributed generation resources’, 2013 regulations. The CEA should consider allowing this functionality in the future based on pilot projects and further studies which should focus on critical issues such as technical specifications for safe automatic isolating equipment at appropriate locations, challenges around anti-islanding control for multiple distributed generators within a micro-grid, safety concerns for personnel and legal liabilities with regard to intentional islanding, etc. The Solar Generation Perspective – Intentional-islanding function
  • 11. www.sterlingwilson.com The Solar Generation Perspective Reactive Power Support Reactive power (measured in var) arises due to phase differences between voltage and current in the system. This phase difference is created by electric and magnetic fields in inductive and capacitive loads (devices that have motors or capacitor banks). Utilities in India mandate customers with a high load requirement (industries) to maintain a power factor close to one. A power factor close to one indicates that the loads are not introducing any reactive power demands on the grid. The demands are met locally by using devices that provide reactive power. For instance, when a motor needs reactive power, it is not necessary to go all the way back to electric power generators on the transmission grid to get it. One can simply use a capacitor bank at the location of the motor and it will provide the required reactive power. This way, consumers have to invest in additional equipment that will allow them to maintain a power factor close to one. However, not all consumers (residential, small commercial) are mandated by the utilities to invest in such additional infrastructure. In such cases, there may still remain a small amount of reactive power demand on the grid and the onus is on utilities to manage this effectively.
  • 12. www.sterlingwilson.com The Solar Generation Perspective Current Regulations - India and abroad • Germany was the first to mandate reactive power support from inverters through the VDE-AR-N 4105 regulation. • The USA has not presently mandated the need for reactive power support in line with the interconnection standard, IEEE 1547. However, discussions are in process to implement it in the near future. A recent report on recommendations for smart inverters has recommended mandating this function in California. • Australia has also proposed this feature in their new AS4777 standard. • India does not have a reactive power support regulation for distributed generation at present. Implications of reactive power support on inverter sizing………………. Benefits of reactive power support……………….
  • 13. www.sterlingwilson.com The Solar Generation Perspective Low/High Voltage Ride-Through (LHVRT) Fault Ride-Through (FRT) features enable grid-tied inverters to stay connected to the grid during voltage or frequency fluctuations of extremely short durations. Low/High Voltage Ride-Through (LHVRT) is one such feature. At the time of a failure (short-circuit or lightning strike), a high current flows through the grid leading to a momentary voltage sag. This would typically trigger the inverter to trip and disconnect until the voltage on the grid stabilises. In such instances, inverters tripping (in a high DG solar penetration scenario) can cause the line voltage to decrease further, which in turn can cause other inverters on the line to trip. This can result in a “cascading effect” that would ultimately rapidly take down all the inverters connected to the distribution network. LHVRT allows inverters to stay connected if such voltage excursions are for very short time durations and the voltage returns to the normal range within a specified time frame. LHVRT does not require the inverter to stay connected if the fault persists beyond a specified time. India currently does not require inverters to have the LHVRT functionality. While this is unproblematic at lower penetration levels, it could be an issue at very high penetration levels.
  • 14. www.sterlingwilson.com The Grid Perspective The Electric Grid of the Future It is adding various technologies to the already existing grid .It covers technologies from the generation sites all the way to the consumers
  • 15. www.sterlingwilson.com The Grid Perspective The electrical infrastructure of the future will be much more complex than the current one. It will have to integrate traditional and sustainable energy sources, present and new distribution systems, storage systems, customers with quite different consumption patterns, demand response based on market signal, and smart control systems. The Problem: At this moment there are no comprehensive enough engineering models that can cope with the higher level of complexity of future electric grids. Can philosophy offer a solution? Dealing with complexity? The successful integration of renewable energy sources and implementation of smart grid technologies will require a holistic analysis and design process.
  • 16. www.sterlingwilson.com The Grid Perspective The level of demand for electricity in any one area is so variable that it is more efficient to combine demand from many sites into an overall regional load. This regional electric load is then met by the output of a fleet of generators that can be controlled and managed for optimal performance. In part, the grid was developed to allow generators to provide backup to each other and share load. Interconnection with Grid :- In order to take benefit of large amount of dispersed Renewables, integration is a necessity. Hitherto planned, designed, constructed, and operated grid meant for haulage of large amount of power from conventional sources has to accommodate the need of such DGR too. Again to take care of uncertainties in this category of generation resources, means of storage too to be accommodated. This may not limit to only pumped storage plant, but also may be battery storage system in conjunction with inverter system for ac grid. It calls for development of smart or intelligent grid that with the application of extensive information and communication technology can be operated and controlled. Distribution system so long carrying power in one direction may have to be bi-directional to carry the power in reverse direction, say, may be from roof-top solar PV generation from customer with proper metering arrangement. In other words, even there would be possibility of re-shaping of load curve to the advantage of all stake-holders. Even problem of congestion management may be easy with the ease in pressure on supply continue………………
  • 17. www.sterlingwilson.com The Grid Perspective company. However, for this upgrading of grid system is a must. With the active participation of consumers a smart grid would employ communication and information technology to optimize energy usage from generation including green energy as well as stored with proper metering. In India with the Distribution system and consequently with the Transmission system initiative towards achieving the same has been taken. RE grid integration challenges Wind and solar generation both experience intermittency, a combination of non-controllable variability and partial unpredictability, and depend on resources that are location-dependent. These three distinct aspects, explained below, each create distinct challenges for generation owners and grid operators in integrating wind and solar generation Non-controllable variability: Wind and solar output varies in a way that generation operators cannot control, because wind speeds and available sunlight may vary from moment to moment, affecting moment-to-moment power output. This fluctuation in power output results in the need for additional energy to balance supply and demand on the grid on an instantaneous basis, as well as ancillary services such as frequency regulation and voltage support.
  • 18. www.sterlingwilson.com The Grid Perspective Integration of RE: • Strong interconnection to sustain variability. • Transmission line capacity as per RE generation • Strengthen Grid code for RE • Dynamic control system • Renewable energy management system
  • 19. www.sterlingwilson.com The Grid Perspective Challenges  Uncontrolled development of capacity addition  Very large grid : Means Complexity, Comprising of several type of technology.  Inadequate T & D  High share of RE fluctuate power Solution  Automation of T & D System  Smart Grid application  Renewable energy forecasting
  • 20. www.sterlingwilson.com The Grid Perspective An evaluation of European smart grid projects showed that it is very difficult to grasp technological and non-technological key characteristics of this complex system: the difficulties encountered during the data collection process; the lack of quantitative data to perform analyses; the recognition of the higher complexity of the system and the lack of proper integration; the difficulties with the setting of business models; the lack of consumer involvement; the need for proper ICT infrastructure; the need for better data protection and security; and the need for a legislative framework to ensure proper division of responsibility. Specific attention to the social implications of renewable sources and innovation in three basic areas are necessary: • Integration of sustainable energy sources; • Development of smart grids to accommodate production and consumption of energy under market signal incentives; Development of models to understand the non-technological aspects of the production and consumption of energy, e.g., social and ethical questions. In addition, these non-technological aspects have to be integrated in the design of sustainable sources and smart grids.
  • 21. www.sterlingwilson.com Conclusion Integration of large penetration of renewable energy systems at the transmission level will require a careful evaluation of the philosophy of the design process. The design needs to consider the complexity of the new system, and deal with it via an Integrated Design Approach, which must be: Integral = all aspects (technologies, social / economic, etc.) Inclusive = all stakeholders – and consider all Ideals = values, missions and visions Significant amounts of storage systems may be required for a normative integration of high penetration of renewables. When technical and economic opportunities can be created by shifting energy over time periods ranging anywhere from seconds to days, then electricity storage may have value. Additionally, the power electronics in battery systems may have fast response and ramp capability and the ability to operate at non-unity power factors, which can be used to change ac voltage. These characteristics may provide additional opportunities to provide ancillary services, like frequency regulation and voltage support and needs to be taken into account as part of the planning and operation philosophical strategies
  • 22. www.sterlingwilson.com References • National Renewable Energy Laboratory, http://www.nrel.gov/solar/ • T. Flick and J. Morehouse, Securing the Smart Grid: Next Generation Power Grid Security. Burlington, MA, USA: Syngress, 2010. • IEEE – PES (Power and Energy Society ), www.ieee-pes.org • M. Malinowski, K. Gopakumar, J. Rodriguez and M. A. Perez, “A survey on cascaded multilevel inverters,” IEEE Trans. Ind. Electron., vol. 57, no. 7, pp. 2197-2206, Jul. 2010