SlideShare a Scribd company logo
1 of 36
Download to read offline
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
SWITCHRACKS
Feam Catalogue 01 - 95
Switchracks
On Request Accessories:
•Stainless steel pipes and fittings
•Galvanized steel epoxy painted supporting rack
•Stainless steel supporting rack
•Internal anticondensate painting orange RAL-2004
•External colours different from standard
Mechanical characteristics
Boxes	 marine grade copper free aluminum - stainless steel
Painting	 external epoxy powders grey RAL-9006 colour
Screws	 external stainless steel
Gaskets	 silicon rubber
Pipes and fittings	 galvanized steel
Supporting rack	 hot dip galvanized steel
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts)
Classification: Group II - Category 2G 2D
CUSTOM DESIGNED
SWITCHRACKS, PANEL BOARDS,
MOTOR STARTERS Ex Enclosures
SWITCHRACK
ATEX 94/9/EC NEC - NEMA 4, 7, 9
EXECUTION/ INSTALLATION II 2 GD Ex d IIB+H2 / IIC Class I - Groups B, C and D / Class II - Groups E, F, and G / Class III
PROTECTION - 4, 7 BCD, 9 EFG
AMBIENT TEMPERATURE -60° + 130°C -20°C ÷ +40°C
MECHANICAL DEGREE IP65 - IP66 IP66
CERTIFICATION AND
COMPLIANCES -
UL Standard 1203 - 4° Ed. (15 Sett. 2006)
Explosion-Proof / Dust-Ignition-Proof
Electrical Equipment for Use in Hazardous (Classified) Locations
ANTISEISMIC TEST
FOR PERFORMING
zone UBC 3 e MSK > VIII < IX
zone UBC 4 MSK > IX
CERTIFICATE REF. CESI doc.: A9022645
RULES OF COMPLIANCE CEI EN 60068-2-57 Cat.1; CEI EN 60068-3-3
YOUR PARTNER FOR SAFETY
Since 1961
SWITCHRACKS
96 - Feam Catalogue 01
Ex Enclosures 		
SWITCHRACKS, PANEL BOARDS - General Information
INFORMATIONS:
Test and inspections:
All components and documents are tested and checked at the various working stages , according to FEAM’s “Quality Pans”.
The above mentioned Plans call for all test and checks necessary to ensure an execution “on purpose”. Whenever a strict, documented quality
control execution is required please advise FEAM Sales Department. When the switchrack is completed ,an effective working inspection is
carried out, and an “inspection report” is written. Customer’s inspectors are allowed in FEAM’s workshop to survey working evolution and
to witness final inspection.
Standard Tests and Checks:
• Visual and dimensional control
• Working control
• Equipment control
Ordering:
The following technical information are needed to work out a switchrack. A direct consult with FEAM Sales Department is however
advisable, especially when problems of space arise.
A) Area classification and mode of protection.
B) Applicable standards
C) Power and auxiliary wiring diagrams or full, detailed description of switchrack’s work
D) Maximum overall dimensions.
Possibility of double front execution
E) Location of incoming and outgoing cable entries
F) Threading, size and number of hubs
G) Type of cable entries
H) Painting cycle, type and color
I) Switchrack’s location (indoor or outdoor)
L) Request of protective canopy(if needed)
N) “Vendor List” of components to be respected (if any)
Responsibility:
Once acknowledged the order, FEAM Technical Dept. issues electrical and mechanical manufacturing drawings.
These drawings are sent to customer “for approval” and whichever change has to be advised as soon as possible.
We take full responsibility for engineering, purchasing and assembling of components ,wiring and erection of the ensemble ready
for installation.
REMARK:
Due to the development of the national and international specifications and of the technology, the above technical characteristics showed
on this bulletin can be considered as binding on our confirmation only.
Description:
“SWITCH-RACK” is a word usually adopted to indicate an ensemble of control units, signaling units, motor starters, switching units, and so on.
Switch-racks are mechanically assembled on robust frame with various fixing solutions (ground, wall, etc.), electrically wired up on purpose.
FEAM since over 40 years, designs and manufacturers switch-racks according to its own diagram or according to customer’s specifications, in full
compliance with European CENELEC standards.
• Grinding check
• Insulation resistance measuring
• Insulation test / Electrical running test
• Mechanical running control
• Hydrostatic test
• Insulation test
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EJB
EJB
Feam Catalogue 01 - 97
Ex Enclosures
ENCLOSURES
On Request Accessories:
•External epoxy painting with colour on request
•Internal anticondensate painting orange RAL-2004
•O-Ring gaskets on cover
•Glass windows on cover
•Drain and breather valves
Mechanical characteristics
Body/cover	 marine grade copper free aluminium light alloy
Screws	 stainless steel
Internal mounting plate	 hot dip galvanized steel / aluminum
Fixing	 fixing lugs AL UNI EN 1706:1999 - galvanized steel stirrups sp. 10mm (EJB71 AND EJB91 ONLY)
Hinges	 On the long side - cast on enclosure body and cover
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
TERMINAL BOARD
Modular terminal strip / power distribution bars
ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d IIB+H2 T6
II 2 G Ex d [ia/ib] IIB+H2 T6
II 2 D Ex tD A21 T85°C
II 2 G Ex d IIB+H2 T6
II 2 G Ex d [ia/ib] IIB+H2 T6
II 2 D Ex tD A21 T85°C
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
A21 TA85°C
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
A21 TA85°C
AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C
PROTECTION DEGREE IP66 IP66 IP66 IP66
CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
POWER UNITS
Current and voltage transformers / power supplies / rectifiers
ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d IIB+H2 T6…T3
II 2 D Ex tD A21 T85°C…150°C
II 2 G Ex d IIB+H2 T6…T3
II 2 D Ex tD A21 T85°C…150°C
1 Ex d IIB+H2 T6…T3
A21 TA85°C…150°C
1 Ex d IIB+H2 T6…T3
A21 TA85°C…150°C
AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C
PROTECTION DEGREE IP66 IP66 IP66 IP66
CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
CONTROL AND SIGNALLING UNITS
Lighting, power and receptacles distribution panelboards / switchracks / dol and dy motor starters / control and signalling panelboards
ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d IIB+H2 T6…T3
II 2 (1) G Ex d [ia] IIB+H2 T6…T3
II 2 (2) G Ex d [ib] IIB+H2 T6…T3
II 2 D Ex tD A21 T85°C…150°C
II 2 G Ex d IIB+H2 T6…T3
II 2 (1) G Ex d [ia] IIB+H2 T6…T3
II 2 (2) G Ex d [ib] IIB+H2 T6…T3
II 2 D Ex tD A21 T85°C…150°C
1 Ex d IIB+H2 T6…T3
1 Ex d [ia] IIB+H2 T6…T3
1 Ex d [ib] IIB+H2 T6…T3
A21 TA85°C…150°C
1 Ex d IIB+H2 T6…T3
1 Ex d [ia] IIB+H2 T6…T3
1 Ex d [ib] IIB+H2 T6…T3
A21 TA85°C…150°C
AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C
PROTECTION DEGREE IP66 IP66 IP66 IP66
CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
EJB
EJB-11	 175	 175	 -	 125	 78	 165	 90	 115	 115	 95 - 95	 3,60	 A
EJB-21	 285	 245	 267	 169	 160	 276	 122	 217	 175	 180 - 140	 10,50	 A
EJB-22	 300	 200	 222	 177	 195	 221	 130	 240	 140	 235 - 135	 12,50	 A
EJB-30	 415	 315	 340	 168	 280	 306	 120	 340	 245	 325 - 225	 18,50	 A
EJB-31	 415	 315	 340	 250	 280	 306	 200	 340	 245	 325 - 225	 20,50	 A
EJB-51	 568	 365	 388	 257	 360	 376	 203	 495	 295	 460 - 260	 36,50	 A
EJB-61	 670	 470	 490	 360	 500	 470	 310	 595	 395	 560 - 360 	 57,00	 A
EJB-63	 670	 470	 490	 235	 500	 470	 184	 595	 395	 560 - 360	 47,00	 A
EJB-71	 742	 542	 572	 425	 500	 456	 360	 645	 445	 590 - 390 	 110,00	 A
EJB-91	 960	 660	 700	 460	 700	 526	 370	 830	 530	 758 - 448 	 202,00	 A
EJB-2	 365	 255	 340	 193	 325	 300	 152	 327	 218	 300 - 190	 17,00	 B
EJB-3	 468	 310	 395	 210	 432	 355	 168	 440	 282	 400 - 240	 23,00	 B
EJB-4	 492	 380	 470	 270	 450	 430	 217	 458	 346	 410 - 300	 33,00	 B
EJB-6	 610	 415	 510	 327	 560	 455	 260	 564	 184	 525 - 325	 65,00	 B
G
HxL
C
B
A
D
F
E
Via M. Pagano, 3
I-20090Trezzano s/N
ITALY
www.feam-ex.com
II2 GD
CUSTODIA tipo
ENCLOSURE type
V Hz A
BKI 08 ATEX 019 Ta
W
Ex d IIB+H Ex tD A21 IP66T °C
NON APRIRE SOTTOTENSIONE
DO NOT OPENWHILE ENERGIZED
Ad ogni apertura del coperchio
ripristinare il grasso ai siliconi.
accertarsi che le valvole di respirazione
e drenaggio siano sempre chiuse
Renew silicone grease every tyme
cover is opened. and make sure
that the drain and breather valves
are always closed.
VA
11.00.88
S.r.l.
2 T
years/n
0722
G
HxL
B
E
A
D
C
F
B
A
98 - Feam Catalogue 01
Ex Enclosures
EJB Technical features
Reference details
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
H
[mm]
L
[mm]
INT. PLATE
X - Y [mm]
WEIGHT
[Kg]
DETAIL
YOUR PARTNER FOR SAFETY
Since 1961
EJB
Via M. Pagano, 3
I-20090Trezzano s/N
ITALY
www.feam-ex.com
II2 GD0722
CUSTODIA tipo
ENCLOSURE type
V Hz A
BKI 08 ATEX 019 Ta
W
Ex d IIB+H Ex tD A21 IP66T °C
NON APRIRE SOTTOTENSIONE
DO NOT OPENWHILE ENERGIZED
Ad ogni apertura del coperchio
ripristinare il grasso ai siliconi.
accertarsi che le valvole di respirazione
e drenaggio siano sempre chiuse
Renew silicone grease every tyme
cover is opened. and make sure
that the drain and breather valves
are always closed.
VA
11.00.88
S.r.l.
2 T
years/n
A
B
F1	 X	 X	 X	 X	 X	 X	 X	 X	 60	 60	 C
F2	 X	 X	 -	 X	 X	 X	 X	 X	 75	 75	 C
F3	 -	 X	 X	 X	 X	 X	 X	 X	 110	 75	 C
F4	 -	 X	 -	 X	 X	 X	 -	 -	 150	 75	 C
F5	 -	 -	 -	 X	 X	 X	 -	 -	 150	 150	 C
F6	 -	 -	 -	 X	 X	 X	 -	 -	 300	 75	 C
F7	 -	 -	 -	 X	 X	 X	 -	 -	 300	 150	 C
F8	 -	 -	 -	 -	 -	 X	 -	 -	 300	 300	 C
F9	 -	 -	 -	 -	 -	 X	 -	 -	 450	 300	 C
EJB-11	 12 x 1	 8 x 1	 6 x 1	 4 x 1	 2 x 1	 -	 -	 -	 95 - 95
EJB-21	 30 x 1	 20 x 1	 14 x 1	 12 x 1	 8 x 1	 6 x 1	 2 x 1	 1 x 1	 180 - 140
EJB-22	 44 x 1	 30 x 1	 20 x 1	 18 x 1	 12 x 1	 10 x 1	 4 x 1	 2 x 1	 235 - 135
EJB-30	 52 x 2	 32 x 2	 24 x 2	 20 x 2	 14 x 2	 12 x 1	 8 x 1	 4 x 1	 325 - 225
EJB-31	 52 x 2	 32 x 2	 24 x 2	 20 x 2	 14 x 2	 12 x 1	 8 x 1	 4 x 1	 325 - 225
EJB-51	 80 x 2	 46 x 2	 36 x 2	 30 x 2	 22 x 2	 18 x 2	 16 x 1	 6 x 1	 460 - 260
EJB-61	 92 x 3	 58 x 3	 46 x 3	 38 x 3	 28 x 3	 26 x 2	 22 x 2	 12 x 1	 560 - 360
EJB-63	 92 x 3	 58 x 3	 46 x 3	 38 x 3	 28 x 3	 26 x 2	 22 x 2	 12 x 1	 560 - 360
EJB-71	 110 x 3	 70 x 3	 56 x 3	 46 x 3	 34 x 3	 28 x 2	 24 x 2	 12 x 1	 590 - 390
EJB-91	 140 x 3	 90 x 3	 70 x 3	 60 x 3	 44 x 3	 36 x 3	 32 x 2	 14 x 2	 758 - 448
EJB-2	 54 x 1	 34 x 1	 26 x 1	 22 x 1	 16 x 1	 12 x 1	 6 x 1	 2 x 1	 300 - 190
EJB-3	 70 x 2	 46 x 2	 36 x 2	 30 x 2	 22 x 2	 18 x 1	 10 x 1	 4 x 1	 400 - 240
EJB-4	 70 X 2	 40 x 2	 32 x 2	 26 x 2	 20 x 2	 14 x 2	 10 x 1	 4 x 1	 410 - 300
EJB-6	 80 x 3	 50 x 3	 36 x 3	 28 x 3	 18 x 3	 16 x 2	 12 x 2	 6 x 1	 525 - 325
C
Feam Catalogue 01 - 99
Ex Enclosures
EJB Glass Windows on Cover
Reference details Reference details
plate
WINDOW
CODE
ENCLOSURE CODE DIMENSIONS
DETAIL
EJB-11 EJB-21 EJB-22 EJB-30/31 EJB-51 EJB-61/63 EJB-71 EJB-91 A [mm] B [mm]
PLATE X-Y
EJB Indicative quantity of terminals and relevant section
CODE
SECT. 2,5
[mm/sq]
SECT. 6,0
[mm/sq]
SECT. 10,0
[mm/sq]
SECT. 16,0
[mm/sq]
SECT. 35,0
[mm/sq]
SECT. 50,0
[mm/sq]
SECT. 70,0
[mm/sq]
SECT. 240,0
[mm/sq]
INT. PLATE X - Y
[mm]
YOUR PARTNER FOR SAFETY
Since 1961
EJB
EJB-11		 120x120	 6	
EJB-21		 200x155	 12	
EJB-22		 240x120	 15	
EJB-30		 305x205	 30	
EJB-31		 305x205	 30	
EJB-51		 465x265	 54	
EJB-61		 575x370	 56	
EJB-63		 575x370	 56	
EJB-71		 590x390	 48	
EJB-91		 800x500	 54	
EJB-2		 290x180	 24	
EJB-3		 380x220	 40	
EJB-4		 390x280	 47	
EJB-6		 500x310	 55	
1	 GK 1/2”	 G 1/2”	 1/2” NPT	 M20
2	 GK 3/4”	 G 3/4”	 3/4” NPT	 M25
3	 GK 1”	 G 1”	 1” NPT	 M32
4	 GK 1-1/4”	 G 1-1/4”	 1-1/4” NPT	 M40
5	 GK 1-1/2”	 G 1-1/2”	 1-1/2” NPT	 M50
6	 GK 2”	 G 2”	 2” NPT	 M63
7	 GK 2-1/2”	 G 2-1/2”	 2-1/2” NPT	 M75
8	 GK 3”	 G 3”	 3” NPT	 M85
E
F
A
B
D
C
EJB-11	 125x60	 4	 2	 2	 1	 1	 -	 -	 -
EJB-21	 200x90	 10	 7	 5	 3	 2	 2	 1	 -
EJB-22	 215x130	 15	 11	 8	 6	 6	 3	 2	 1
EJB-30	 320x65	 13	 7	 5	 5	 4	 3	 -	 -
EJB-31	 320x150	 28	 18	 14	 11	 8	 6	 3	 2
EJB-51	 460x155	 44	 27	 24	 20	 12	 10	 6	 3
EJB-61	 550x250	 72	 50	 36	 32	 21	 21	 14	 8
EJB-63	 550x130	 36	 29	 18	 16	 14	 7	 5	 4
EJB-71	 600x270	 78	 55	 50	 36	 32	 21	 18	 10
EJB-91	 745x290	 112	 84	 65	 55	 40	 28	 23	 14
EJB-1	 175x115	 12	 6	 6	 5	 3	 2	 1	 1
EJB-2	 310x105	 17	 12	 10	 9	 5	 4	 3	 2
EJB-3	 425x115	 30	 17	 14	 12	 9	 5	 4	 3
EJB-C237	 200x60	 6	 4	 3	 2	 2	 -	 -	 -
	 125x60	 4	 2	 2	 1	 1	 -	 -	 -
	 160x90	 8	 5	 4	 3	 2	 1	 1	 -
	 110x130	 9	 5	 5	 4	 2	 1	 1	 1
	 225x65	 9	 5	 4	 3	 3	 2	 -	 -
	 225x150	 20	 12	 9	 8	 6	 5	 2	 1
	 255x155	 24	 15	 12	 11	 6	 6	 3	 2
	 350x250	 48	 30	 24	 20	 12	 12	 8	 6
	 350x130	 24	 17	 12	 10	 8	 4	 3	 3
	 400x270	 48	 35	 35	 24	 20	 15	 12	 6
	 440x290	 70	 42	 35	 35	 24	 18	 13	 8
	 175x115	 12	 6	 6	 5	 3	 2	 1	 1
	 200x105	 11	 8	 6	 5	 3	 2	 2	 1
	 270x115	 18	 11	 8	 8	 6	 3	 2	 2
	 130x60	 4	 2	 2	 2	 1	 -	 -	 -
100 - Feam Catalogue 01
Ex Enclosures
EJB Body and Cover Enclosures Drilling Layout
wall DRILLING AREA
REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
Cover DRILLING AREA
Reference details
Reference details
ENCLOSURE
CODE
DRILLING
AREA A-B
[mm]
QUANTITY ALLOWED ENTRIES FOR
size (from 1 to size 8)
1 2 3 4 5 6 7 8
DRILLING AREA
C-D [mm]
QUANTITY ALLOWED ENTRIES FOR
size (from 1 to size 8)
1 2 3 4 5 6 7 8
ENCLOSURE
CODE
DRILLING AREA E-F
[mm]
MAX OPERATORS
PERMITTED
EJB Threads comparation table
size UNI 6125 ISO 228/1 ASA B2.1 ISO 965/I
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EJBinx
EJB INX
Feam Catalogue 01 - 101
Ex Enclosures
ENCLOSURES
On Request Accessories:
•External epoxy painting (any colours)
•Internal anticondensate painting orange RAL-2004
•O-Ring gaskets on cover
•Glass windows on cover
Mechanical characteristics
Body & cover	 stainless steel AISI-316 L
Screws	 stainless steel
Internal mounting plate	 stainless steel / aluminum
Fixing	 fixing lugs stainless steel AISI-316 L - stainless steel stirrups sp.10mm (EJB71 AND EJB91 ONLY)
Hinges	 applied
Opening handle	 insulating material fixed on cover by stainless steel screws
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
TERMINAL BOARD
Modular terminal strip / power distribution bars
ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d IIB+H2 T6
II 2 G Ex d [ia/ib] IIB+H2 T6
II 2 D Ex tD A21 T85°C
II 2 G Ex d IIB+H2 T6
II 2 G Ex d [ia/ib] IIB+H2 T6
II 2 D Ex tD A21 T85°C
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
A21 TA85°C
1 Ex d IIB+H2 T6
1 Ex d [ia/ib] IIB+H2 T6
A21 TA85°C
AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C
PROTECTION DEGREE IP66 IP66 IP66 IP66
CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0
EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
POWER UNITS
Current and voltage transformers / power supplies / rectifier
ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d IIB+H2 T6…T3
II 2 D Ex tD A21 T85°C…150°C
II 2 G Ex d IIB+H2 T6…T3
II 2 D Ex tD A21 T85°C…150°C
1 Ex d IIB+H2 T6…T3
A21 TA85°C…150°C
1 Ex d IIB+H2 T6…T3
A21 TA85°C…150°C
AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C
PROTECTION DEGREE IP66 IP66 IP66 IP66
CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0
EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
CONTROL AND SIGNALLING UNITS
Lighting, power and receptacles distribution panelboards / switchracks / dol and dy motor starters / control and signalling panelboards
ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d IIB+H2 T6…T3
II 2 (1) G Ex d [ia] IIB+H2 T6…T3
II 2 (2) G Ex d [ib] IIB+H2 T6…T3
II 2 D Ex tD A21 T85°C…150°C
II 2 G Ex d IIB+H2 T6…T3
II 2 (1) G Ex d [ia] IIB+H2 T6…T3
II 2 (2) G Ex d [ib] IIB+H2 T6…T3
II 2 D Ex tD A21 T85°C…150°C
1 Ex d IIB+H2 T6…T3
1 Ex d [ia] IIB+H2 T6…T3
1 Ex d [ib] IIB+H2 T6…T3
A21 TA85°C…150°C
1 Ex d IIB+H2 T6…T3
1 Ex d [ia] IIB+H2 T6…T3
1 Ex d [ib] IIB+H2 T6…T3
A21 TA85°C…150°C
AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C
PROTECTION DEGREE IP66 IP66 IP66 IP66
CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0
EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
EJBinx
EJB-21 INX	 285	 245	 260	 194	 160	 230	 122	 215	 175	 180 - 140	 32,00	 A
EJB-22 INX	 300	 200	 215	 218	 195	 188	 177	 230	 130	 235 - 135	 38,00	 A
EJB-30 INX	 415	 315	 330	 158	 294	 290	 117	 335	 235	 325 - 225	 53,00	 A
EJB-31 INX	 415	 315	 330	 223	 294	 290	 180	 335	 235	 325 - 225	 62,00	 A
EJB-51 INX	 565	 365	 400	 233	 360	 335	 190	 480	 280	 460 - 260	 110,00	 A
EJB-61 INX	 670	 470	 485	 344	 500	 437	 290	 590	 390	 560 - 360 	 152,00	 A
EJB63 INX	 670	 470	 485	 229	 500	 437	 180	 590	 390	 560 - 360	 140,00	 A
EJB-71 INX	 742	 542	 557	 400	 500	 456	 360	 645	 445	 590 - 390	 280,00	 A
EJB-91 INX	 960	 660	 678	 431	 600	 640	 364	 843	 543	 758 - 448 	 618,00	 A
EJB-21 INX	 30 x 1	 20 x 1	 14 x 1	 12 x 1	 8 x 1	 6 x 1	 2 x 1	 1 x 1	 180 - 140
EJB-22 INX	 44 x 1	 30 x 1	 20 x 1	 18 x 1	 12 x 1	 10 x 1	 4 x 1	 2 x 1	 235 - 135
EJB-30 INX	 52 x 2	 32 x 2	 24 x 2	 20 x 2	 14 x 2	 12 x 1	 8 x 1	 4 x 1	 325 - 225
EJB-31 INX	 52 x 2	 32 x 2	 24 x 2	 20 x 2	 14 x 2	 12 x 1	 8 x 1	 4 x 1	 325 - 225
EJB-51 INX	 80 x 2	 46 x 2	 36 x 2	 30 x 2	 22 x 2	 18 x 2	 16 x 1	 6 x 1	 460 - 260
EJB-61 INX	 92 x 3	 58 x 3	 46 x 3	 38 x 3	 28 x 3	 26 x 2	 22 x 2	 12 x 1	 560 - 360
EJB-63 INX	 92 x 3	 58 x 3	 46 x 3	 38 x 3	 28 x 3	 26 x 2	 22 x 2	 12 x 1	 560 - 360
EJB-71 INX	 110 x 3	 70 x 3	 56 x 3	 46 x 3	 34 x 3	 28 x 2	 24 x 2	 12 x 1	 590 - 390
EJB-91 INX	 140 x 3	 90 x 3	 70 x 3	 60 x 3	 44 x 3	 36 x 3	 32 x 2	 14 x 2	 758 - 448
BKI 08 ATEX 019
Via M. Pagano, 3
I-20090Trezzano s/N
ITALY
www.feam-ex.com
NON APRIRE SOTTOTENSIONE
DO NOT OPENWHILE ENERGIZED
Ad ogni apertura del coperchio
ripristinare il grasso ai siliconi.
accertarsi che le valvole di respirazione
e drenaggio siano sempre chiuse
Renew silicone grease every tyme
cover is opened. and make sure
that the drain and breather valves
are always closed.
11.00.88
S.r.l.
II2 GD0722
CUSTODIA tipo
ENCLOSURE type
V Hz A
Ta
W
Ex d IIB+H Ex tD A21 IP66T °C
VA
2 T
years/n
G
HxL
C
B
A
D
F
E
A
102 - Feam Catalogue 01
Ex Enclosures
EJB INX Technical features
Reference details
EJB Indicative quantity of terminals and relevant section
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
H
[mm]
L
[mm]
INT. PLATE
X - Y [mm]
WEIGHT
[Kg]
DETAIL
CODE
SECT. 2,5
[mm/sq]
SECT. 6,0
[mm/sq]
SECT. 10,0
[mm/sq]
SECT. 16,0
[mm/sq]
SECT. 35,0
[mm/sq]
SECT. 50,0
[mm/sq]
SECT. 70,0
[mm/sq]
SECT. 240,0
[mm/sq]
INT. PLATE X - Y
[mm]
YOUR PARTNER FOR SAFETY
Since 1961
EJBinx
Via M. Pagano, 3
I-20090Trezzano s/N
ITALY
www.feam-ex.com
NON APRIRE SOTTOTENSIONE
DO NOT OPENWHILE ENERGIZED
Ad ogni apertura del coperchio
ripristinare il grasso ai siliconi.
accertarsi che le valvole di respirazione
e drenaggio siano sempre chiuse
Renew silicone grease every tyme
cover is opened. and make sure
that the drain and breather valves
are always closed.
11.00.88
S.r.l.
II2 GD0722
CUSTODIA tipo
ENCLOSURE type
V Hz A
Ta
W
Ex d IIB+H Ex tD A21 IP66T °C
VA
2 T
years/n
BKI 08 ATEX 019
A
B
A
B
D
C
F1	 X	 X	 X	 X	 X	 X	 X	 60	 60	 C
F2	 X	 -	 X	 X	 X	 X	 X	 75	 75	 C
F3	 X	 X	 X	 X	 X	 X	 X	 110	 75	 C
F4	 X	 -	 X	 X	 X	 -	 -	 150	 75	 C
F5	 -	 -	 X	 X	 X	 -	 -	 150	 150	 C
F6	 -	 -	 X	 X	 X	 -	 -	 300	 75	 C
F7	 -	 -	 X	 X	 X	 -	 -	 300	 150	 C
F8	 -	 -	 -	 -	 X	 -	 -	 300	 300	 C
F9	 -	 -	 -	 -	 X	 -	 -	 450	 300	 C
EJB-21 INX	 200x90	 10	 7	 5	 3	 2	 2	 1	 -
EJB-22 INX	 215x130	 15	 11	 8	 6	 6	 3	 2	 1
EJB-30 INX	 320x65	 13	 7	 5	 5	 4	 3	 -	 -
EJB-31 INX	 320x150	 28	 18	 14	 11	 8	 6	 3	 2
EJB-51 INX	 460x155	 44	 27	 24	 20	 12	 10	 6	 3
EJB-61 INX	 550x250	 72	 50	 36	 32	 21	 21	 14	 8
EJB-63 INX	 550x130	 36	 29	 18	 16	 14	 7	 5	 4
EJB-71 INX	 600x270	 78	 55	 50	 36	 32	 21	 18	 10
EJB-91 INX	 745x290	 112	 84	 65	 55	 40	 28	 23	 14
	 160x90	 8	 5	 4	 3	 2	 1	 1	 -
	 110x130	 9	 5	 5	 4	 2	 1	 1	 1
	 225x65	 9	 5	 4	 3	 3	 2	 -	 -
	 225x150	 20	 12	 9	 8	 6	 5	 2	 1
	 255x155	 24	 15	 12	 11	 6	 6	 3	 2
	 350x250	 48	 30	 24	 20	 12	 12	 8	 6
	 350x130	 24	 17	 12	 10	 8	 4	 3	 3
	 400x270	 48	 35	 35	 24	 20	 15	 12	 6
	 440x290	 70	 42	 35	 35	 24	 18	 13	 8
C
Feam Catalogue 01 - 103
Ex Enclosures
EJB INX Glass Windows on Cover
Reference details Reference details
plate
PLATE X-Y
EJB INX Body and Cover Enclosures Drilling Layout
Reference details
ENCLOSURE
CODE
DRILLING AREA
A-B [mm]
QUANTITY ALLOWED ENTRIES FOR
size (from 1 to size 8)
1 2 3 4 5 6 7 8
DRILLING AREA
C-D [mm]
QUANTITY ALLOWED ENTRIES FOR
size (from 1 to size 8)
1 2 3 4 5 6 7 8
wall DRILLING AREA
WINDOW
CODE
ENCLOSURE CODE DIMENSIONS
DETAILEJB-21
INX
EJB-22
INX
EJB-30/31
INX
EJB-51
INX
EJB-61/63
INX
EJB-71
INX
EJB-91
INX
A [mm] B [mm]
YOUR PARTNER FOR SAFETY
Since 1961
EJBinx
EJB-21 INX	 200x155	 12	
EJB-22 INX	 240x120	 15	
EJB-30 INX	 305x205	 30	
EJB-31 INX	 305x205	 30	
EJB-51 INX	 465x265	 54	
EJB-61 INX	 575x370	 56	
EJB-63 INX	 575x370	 56	
EJB-71 INX	 590x390	 48
EJB-91 INX	 800x500	 54	
E
F
1	 GK 1/2”	 G 1/2”	 1/2” NPT	 M20
2	 GK 3/4”	 G 3/4”	 3/4” NPT	 M25
3	 GK 1”	 G 1”	 1” NPT	 M32
4	 GK 1-1/4”	 G 1-1/4”	 1-1/4” NPT	 M40
5	 GK 1-1/2”	 G 1-1/2”	 1-1/2” NPT	 M50
6	 GK 2”	 G 2”	 2” NPT	 M63
7	 GK 2-1/2”	 G 2-1/2”	 2-1/2” NPT	 M75
8	 GK 3”	 G 3”	 3” NPT	 M85
104 - Feam Catalogue 01
Ex Enclosures
EJB INX Body and Cover Enclosures Drilling Layout
Cover DRILLING AREA
Reference details
REMARK:
Due to the development of the national and international specifications and of the technology, the above technical characteristics showed
on this bulletin can be considered as binding on our confirmation only.
ENCLOSURE
CODE
DRILLING AREA
E-F [mm]
MAX OPERATORS
PERMITTED
EJB INX Threads comparation table
size UNI 6125 ISO 228/1 ASA B2.1 ISO 965/I
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EJBul
EJB UL
Feam Catalogue 01 - 105
Ex Enclosures
ENCLOSURES
On Request Accessories:
•	External epoxy painting (any colours)
•	Internal anticondensate painting orange RAL-2004
•	O-Ring gaskets on cover
•	Glass windows on cover
•	Drain and breather valves
•	Stainless steel hinges
Mechanical characteristics
Body and cover	 marine grade copper free aluminium light alloy
Screws	 stainless steel - internal / external
Internal plate	 hot dip galvanized steel / aluminium
Fixing	 galvanized steel stirrups th.10mm
Gaskets	 O-RING silicon rubber on cover (option on request)
Installation: hazardous areas - see below table
Classification: see below table
TERMINAL BOARD / POWER UNITS
CONTROL AND SIGNALLING UNITS
NEC - NEMA 4, 7, 9
INSTALLATION Class I - Groups B, C and D / Class II – Groups E, F, and G / Class III
PROTECTION 4, 7 BCD, 9 EFG
AMBIENT TEMPERATURE -20°C ÷ +40°C
MECHANICAL DEGREE IP66
CERTIFICATION AND
COMPLIANCES
UL Standard 1203 - 4° Ed. (15 Sett. 2006)
Explosion-Proof / Dust-Ignition-Proof
Electrical Equipment for Use in Hazardous (Classified) Locations
YOUR PARTNER FOR SAFETY
Since 1961
EJBul
EJB-21UL	 320	 280	 182	 180	 250	 123	 220	 180	 180 - 140	 13,50	 A
EJB-31UL	 450	 350	 253	 294	 335	 187	 350	 250	 325 - 225	 27,00	 A
EJB-51UL	 600	 400	 240	 360	 385	 195	 490	 290	 460 - 260	 52,50	 A
EJB-61UL	 710	 500	 384	 500	 470	 295	 580	 370	 560 - 360 	 114,00	 A
EJB-63UL	 710	 500	 200	 500	 470	 165	 580	 370	 560 - 360	 92,00	 A
EJB-21UL	 12,60	 11,10	 7,20	 7,10	 9,90	 4,90	 8,70	 7,10	 7.10 - 5.60	 31,00	 A
EJB-31UL	 17,80	 13,80	 10,00	 11,60	 13,20	 7,40	 13,80	 9,90	 12.80 - 8.90	 62,00	 A
EJB-51UL	 23,70	 15,80	 9,50	 14,20	 15,20	 7,70	 19,30	 11,50	 18.20 - 10.30	 121,00	 A
EJB-61UL	 28,00	 19,70	 15,20	 19,70	 18,60	 11,70	 22,90	 14,60	 22.10 - 14.20	 262,00	 A
EJB-63UL	 28,00	 19,70	 7,90	 19,70	 18,60	 6,50	 22,90	 14,60	 22.10 - 14.20	 212,00	 A
G
HxL
B
A
D
F
E
EJB-21 UL	 190	 80	 7,50	 3,20	 150	 80	 6,00	 3,20
EJB-31 UL	 320	 140	 12,60	 5,60	 230	 140	 9,10	 5,60
EJB-51 UL	 450	 120	 17,80	 4,80	 250	 120	 9,90	 4,80
EJB-61 UL	 550	 260	 21,70	 10,30	 350	 260	 13,80	 10,30
EJB-63 UL	 550	 150	 21,70	 6,00	 350	 150	 13,80	 6,00
A
CODE
A
[mm]
B
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
H
[mm]
L
[mm]
INT. PLATE
X-Y [mm]
WEIGHT
[Kg]
DETAIL
CODE
A
[inch.]
B
[inch.]
D
[inch.]
E
[inch.]
F
[inch.]
G
[inch.]
H
[inch.]
L
[inch.]
INT. PLATE
X - Y [inch.]
WEIGHT
[lbs]
DETAIL
106 - Feam Catalogue 01
Ex Enclosures
EJB UL Technical features
EJB UL Body Enclosures Drilling Layout
Reference details
ENCLOSURE
CODE
AREA FOR ENTRY INSTALLATION (LONG WALL SIDES) AREA FOR ENTRY INSTALLATION (SHORT WALL SIDES)
A
[mm]
B
[mm]
A
[inch.]
B
[inch.]
C
[mm]
D
[mm]
C
[inch.]
D
[inch.]
YOUR PARTNER FOR SAFETY
Since 1961
EJBul
CA
B
D
	 4”	
-	 -	 -	 -	 -	 -	 -	 -
	 139
	 -									 (5.47)
	 3”	
-	 -	 -	 -	 -	 -	 -
	 115	 126
	 M90								 (4.53)	 (4.96)
	 2 1/2”	
-	 -	 -	 -	 -	 -
	 101	 108	 120
	 M75							 (3.98)	 (4.25)	 (4.72)
	 2”	
-	 -	 -	 -	 -
	 88	 94	 102	 112
	 M63						 (3.46)	 (3.70)	 (4.02)	 (4.41)
	 1 1/2”	
-	 -	 -	 -
	 75	 82	 88	 95	 106
	 M50					 (2.95)	 (3.23)	 (3.46)	 (3.74)	 (4.17)
	 1 1/4”	
-	 -	 -
	 67	 70	 77	 84	 91	 103
	 M40				 (2.64)	 (2.76)	 (3.03)	 (3.31)	 (3.58)	 (4.06)
	 1”	
-	 -
	 58	 63	 66	 73	 80	 86	 99
	 M32			 (2.28)	 (2.48)	 (2.60)	 (2.87)	 (3.15)	 (3.39)	 (3.90)
	 3/4”	
-
	 52	 55	 59	 63	 69	 79	 83	 95
	 M25		 (2.05)	 (2.17)	 (2.32)	 (2.48)	 (2.72)	 (2.99)	 (3.27)	 (3.74)
	 1/2”	 46	 49	 52	 57	 60	 67	 73	 80	 93
	 M20	 (1.81)	 (1.93)	 (2.05)	 (2.24)	 (2.36)	 (2.64)	 (2.87)	 (3.15)	 (3.66)
	 NPT	 1/2”	 3/4”	 1”	 1 1/4”	 1 1/2”	 2”	 2 1/2”	 3”	 4”
	 Metric	 M20	 M25	 M32	 M40	 M50	 M63	 M75	 M90	 -
E
F
EJB-21 UL	 200	 150	 7,90	 6,00	 50	 2,00	
EJB-31 UL	 300	 200	 11,90	 7,90	 50	 2,00	
EJB-51 UL	 460	 260	 18,20	 10,30	 50	 2,00	
EJB-61 UL	 570	 370	 22,50	 14,60	 50	 2,00	
EJB-63 UL	 570	 370	 22,50	 14,60	 50	 2,00	
Feam Catalogue 01 - 107
Ex Enclosures
EJB UL Body Enclosures Drilling Layout
Reference details
WALL DRILLING AREA
MINIMUM DISTANCE BETWEEN WAAL ENTRIES (CENTER TO CENTER)
1st ROW [mm] - 2nd ROW [inch.]
EJB UL Cover Enclosures Drilling Layout
ENCLOSURE
CODE
AREA FOR OPERATORS
INSTALLATION ENCLOSURE COVER
MINUMUM DISTANCE
BETWEEN OPENINGS
(CENTER TO CENTER)
E
[mm]
F
[mm]
E
[inch.]
F
[inch.]
[mm] [inch.]
Cover DRILLING AREA
YOUR PARTNER FOR SAFETY
Since 1961
EJBul
EJB-21 UL	 30 x 1	 20 x 1	 14 x 1	 12 x 1	 8 x 1	 6 x 1	 2 x 1	 1 x 1	 180 - 140	 7.10 - 5.60
EJB-31UL	 52 x 2	 32 x 2	 24 x 2	 20 x 2	 14 x 2	 12 x 1	 8 x 1	 4 x 1	 325 - 225	 12.80 - 8.90
EJB-51 UL	 80 x 2	 46 x 2	 36 x 2	 30 x 2	 22 x 2	 18 x 2	 16 x 1	 6 x 1	 460 - 260	 18.20 - 10.30
EJB-61 UL	 92 x 3	 58 x 3	 46 x 3	 38 x 3	 28 x 3	 26 x 2	 22 x 2	 12 x 1	 560 - 360 	 22.10 - 14.20
EJB-63 UL	 92 x 3	 58 x 3	 46 x 3	 38 x 3	 28 x 3	 26 x 2	 22 x 2	 12 x 1	 560 - 360	 22.10 - 14.20
108 - Feam Catalogue 01
REMARK:
Due to the development of the national and international specifications and of the technology, the above technical characteristics showed
on this bulletin can be considered as binding on our confirmation only.
EJB UL Additional Technical features
PRODUCT COVERED
Explosion-proof enclosures for use in Hazardous Locations, Class I, Groups B, C, and D; Class II, Groups E, F, and G; Class III.
These enclosures are Classified as to explosion and fire hazards only in according to Standard UL1203 4° ed.
The explosion-proof enclosures are suitable for Class I, Group B Hazardous Locations only when provided with from M20 to M90, 1/2 in. to 3 in., supply
connection openings. If other supply connection openings are provided, then the enclosures are suitable for Class I, Groups C & D Hazardous Locations only.
The 1/2 in. NPSM operator openings are only suitable for enclosures marked for Class I, Groups B, C & D Hazardous Locations
The enclosures covered by this Certification may have electrical components installed inside. The installation of electrical components shall not reduce the
mechanical integrity of the enclosures.
The enclosures may or may not be provided with hinges for service of the enclosures only.
PROTECTION AGAINST CORROSION
All ferrous-metal other than stainless steel shall be protected against corrosion, except at joint surfaces and conduit threads There shall be no materials
applied to joint surfaces.
GROUNDING
Internal Ground Screw – Hexagon head screw M6 x 10 with a stainless steel flat and lock washer provided on the base of the enclosure body.
External Ground – Terminal colored green, marked with the letter or word “G”, “GROUND”, or marked with a grounding symbol.
SUPPLY CONNECTIONS
NPT and Metric Supply Connections - The side walls of the enclosure are provided with conduit openings or none may be supplied, in which case field drilling
and tapping instructions are provided with each enclosure. The entry is drilled and tapped completely through the enclosure wall, and the inside edge is
smoothed and well-rounded such that the conductor insulation will not be damaged when installed. All unused openings are closed with plated steel, plated
cast iron or aluminum close-up plugs which are threaded to match the opening. Closer-up Plugs have to be Listed for the same Class, Group and Division as
marked on Enclosure nameplate.
OPERATOR OPENINGS
The cover of the enclosure may be provided with operator openings in the cover only and located only as given in drilling and tapping instructions provided
with each Classified enclosure. All unused openings are closed with plated steel, plated cast iron or aluminum close-up plugs which are threaded to match the
opening. Closer-up Plugs have to be Listed for the same Class, Group and Division as marked on Enclosure nameplate.
EJB UL Indicative quantity of terminals and relevant section
CODE
SECT. 2,5
[mm/sq]
SECT.6,0
[mm/sq]
SECT. 10,0
[mm/sq]
SECT. 16,0
[mm/sq]
SECT. 35,0
[mm/sq]
SECT. 50,0
[mm/sq]
SECT. 70,0
[mm/sq]
SECT. 240,0
[mm/sq]
INT. PLATE X - Y
[mm] [inch.]
Ex Enclosures
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
GUB
GUB
Feam Catalogue 01 - 109
Ex Enclosures
ENCLOSURES
On Request Accessories:
•	External epoxy painting with colour on request
•	Internal anticondensate painting orange RAL-2004
•	O-Ring gaskets on cover
•	Glass windows on cover
•	Drain and breather valves
Mechanical characteristics
Body marine grade copper free aluminium light alloy
Cover marine grade copper free aluminium light alloy
Screws stainless sttel
Internal plate hot dip galvanized steel / aluminium
Fixing fixing lugs AL UNI 4514 casting on enclosure body
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
POWER UNIT / CONTROL AND SIGNALLING UNITS / TERMINAL BOARD
ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d IIC T3…T6
II 2(1) GD Ex d [ia/ib] IIC T6
II 2 D Ex tD A21 T85°C...T200°C
II 2 D Ex tD [iaD/ibD] A21 T85°C
II 2 G Ex d IIC T3…T6
II 2(1) GD Ex d [ia/ib] IIC T6
II 2 D Ex tD A21 T85°C...T200°C
II 2 D Ex tD[iaD/ibD] A21 T85°C
1 Ex d IIC T6, T5,T4X
1 Ex d [ia/ib] IIC T6X
DIP A21 TA (85°C,100°C-135°C)
1 Ex d IIC T6, T5,T4X
1 Ex d [ia/ib] IIC T6X
DIP A21 TA (85°C,100°C-135°C)
AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C
PROTECTION DEGREE IP66 IP66 IP66 IP66
CERTIFICATE REF. BKI 08 ATEX 048 IECEx BKI 09.0004 POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1; EN 61241-11
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
GUB
GUE1	 135	 135	 108	 93	 151	 115	 100	 45	 110	 110	 -	 Ø90	 2,00	 A
GUB0	 168	 168	 140	 123	 190	 140	 154	 80	 140	 140	 -	 110 - 110	 3,50	 A
GUB1	 198	 198	 150	 132	 200	 200	 176	 90	 170	 170	 -	 150 - 150	 5,00	 A
GUB02	 235	 280	 173	 150	 260	 240	 210	 100	 207	 252	 -	 200 - 150	 8,00	 A
GUB03	 280	 305	 225	 198	 308	 207	 275	 125	 248	 273	 -	 220 - 200	 10,50	 A
GUB23	 270	 310	 180	 150	 315	 275	 244	 102	 243	 280	 -	 180 - 180	 10,50	 A
GUB4	 420	 420	 284	 230	 460	 380	 400	 150	 390	 390	 -	 280 - 280	 30,00	 A
GUB5	 600	 600	 334	 310	 630	 550	 580	 210	 550	 550	 -	 490 - 490	 77,00	 A
GUBW11	 180	 180	 146	 130	 210	 146	 160	 77	 152	 152	 80	 145 - 130	 6,50	 B
GUBW02	 235	 280	 167	 150	 260	 240	 210	 100	 207	 252	 120	 200 - 150	 11,00	 B
GUBW03	 280	 305	 235	 298	 308	 270	 275	 125	 248	 273	 195	 220 - 200	 18,00	 B
F
D
O
n
O
T
N
OPE
e L WHI
G R
ENE
D
IZ
E
NON
E
IR
A
P
R
T O
S O T
NO
N S I
E
T E
GU
MATR.-ANNO
S. Nr.-YEAR
www.feam-ex.comS.r.l.
II 2G Ex d[ ] IICT
II 2D Ex tD [ ]A21 IP66T °C
BKI 08 ATEX 0480722
V Hz W A
Ta
NON APRIRE SOTTO TENSIONE /DO NOT OPEN WHILE ENERGIZED
AD OGNI APERTURA DEL COPERCHIO RIPRISTINARE IL GRASSO
AL SILICONE ACCERTARSI CHE LE VALVOLE DI RESPIRAZIONE
E DRENAGGIO SIANO SEMPRE CHIUSE
RENEW SILICONE GREASE EVERY TIME COVER IS OPENED
AND MAKE SURE THAT THE DRAIN AND
BREATHER VALVES ARE ALWAYS CLOSED
11.10.93
C
AD
H
I-L
ØG
E
B
ØG
E
B
ØM
D
C
A
F
H
I-L
A
B
110 - Feam Catalogue 01
Ex Enclosures
GUB Technical features
Reference details
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
Ø G
[mm]
H
[mm]
I
[mm]
L
[mm]
Ø M
[mm]
INT.PLATE
X - Y
[mm]
WEIGHT
[Kg]
DETAIL
YOUR PARTNER FOR SAFETY
Since 1961
GUB
GUE1	 102x50	 2	 1	 1	 1	 /	 /	 /	 /
GUB0	 128x80	 6	 3	 2	 2	 1	 1	 1	 /
GUB1	 148x87	 6	 3	 3	 2	 2	 1	 1	 /
GUB02	 235x82	 11	 6	 5	 4	 3	 3	 2	 /
GUB03	 263x120	 15	 11	 9	 8	 6	 4	 2	 2
GUB23	 270x97	 11	 10	 8	 6	 4	 3	 2	 /
GUB4	 350x140	 23	 18	 14	 11	 10	 7	 4	 3
GUB5	 550x195	 45	 36	 27	 24	 18	 12	 6	 3
GUBW11	 150x77	 6	 4	 3	 2	 2	 1	 /	 /
GUBW02	 235x82	 11	 6	 5	 4	 3	 3	 2	 /
GUBW03	 263x120	 15	 11	 9	 8	 6	 4	 2	 2
	 102x50	 2	 1	 1	 1	 /	 /	 /	 /
	 128x80	 6	 3	 2	 2	 1	 1	 1	 /
	 148x87	 6	 3	 3	 2	 2	 1	 1	 /
	 190x82	 8	 5	 4	 3	 2	 2	 2	 /
	 238x120	 12	 9	 8	 6	 6	 3	 2	 2
	 230x97	 9	 8	 8	 5	 3	 3	 2	 /
	 350x140	 23	 18	 14	 11	 10	 7	 4	 3
	 550x195	 45	 36	 27	 24	 18	 12	 6	 3
	 150x77	 6	 4	 3	 2	 2	 1	 /	 /
	 190x82	 8	 5	 4	 3	 2	 2	 2	 /
	 238x120	 12	 9	 8	 6	 6	 3	 2	 2
A
BB
C
D
Feam Catalogue 01 - 111
Ex Enclosures
GUB Body Enclosures Drilling Layout
ENCLOSURE
CODE
DRILLING
AREA A-B
[mm]
QUANTITY ALLOWED ENTRIES FOR
size (from 1 to size 8)
1 2 3 4 5 6 7 8
DRILLING AREA
C-D [mm]
QUANTITY ALLOWED ENTRIES FOR
size (from 1 to size 8)
1 2 3 4 5 6 7 8
Reference details Reference details
wall DRILLING AREA plate
PLATE
X-Y
PLATE
X-Y
YOUR PARTNER FOR SAFETY
Since 1961
GUB
GUE1	 8x1	 4x1	 4x1	 2x1	 2x1	 /	 /	 /	 Ø90
GUB0	 12x1	 6x1	 6x1	 4x1	 4x1	 2x1	 1x1	 /	 110 - 110
GUB1	 20x1	 10x1	 10x1	 6x1	 6x1	 4x1	 2x1	 1x1	 150 - 150
GUB02	 32x1	 18x1	 16x1	 12x1	 8x1	 6x1	 4x1	 2x1	 200 - 150
GUB03	 34x1	 20x1	 18x1	 14x1	 10x1	 8x1	 6x1	 4x1	 220 - 200
GUB23	 26x1	 16x1	 14x1	 12x1	 8x1	 6x1	 4x1	 1x1	 180 - 180
GUB4	 48x2	 28x2	 24x2	 20x2	 12x2	 10x2	 8x1	 4x1	 280 - 280
GUB5	 64x3	 20x3	 36x3	 30x3	 11x3	 16x3	 16x1	 6x2	 490 - 490
GUBW11	 16x1	 10x1	 8x1	 8x1	 6x1	 4x1	 2x1	 /	 140 - 130
GUBW2	 32x1	 18x1	 16x1	 12x1	 8x1	 6x1	 4x1	 2x1	 200 - 150
GUBW3	 34x1	 20x1	 18x1	 14x1	 10x1	 8x1	 6x1	 4x1	 220 - 200
1	 GK 1/2”	 G 1/2”	 1/2” NPT	 M20
2	 GK 3/4”	 G 3/4”	 3/4” NPT	 M25
3	 GK 1”	 G 1”	 1” NPT	 M32
4	 GK 1-1/4”	 G 1-1/4”	 1-1/4” NPT	 M40
5	 GK 1-1/2”	 G 1-1/2”	 1-1/2” NPT	 M50
6	 GK 2”	 G 2”	 2” NPT	 M63
7	 GK 2-1/2”	 G 2-1/2”	 2-1/2” NPT	 M75
8	 GK 3”	 G 3”	 3” NPT	 M85
112 - Feam Catalogue 01
Ex Enclosures
Gub Sindicative quantity of terminals and relevant section
REMARK:
Due to the development of the national and international specifications and of the technology, the above technical characteristics showed
on this bulletin can be considered as binding on our confirmation only.
CODE
ENCLOSURE
SECT. 2,5
[mm/sq]
SECT. 6,0
[mm/sq]
SECT. 10,0
[mm/sq]
SECT. 16,0
[mm/sq]
SECT. 35,0
[mm/sq]
SECT. 50,0
[mm/sq]
SECT. 70,0
[mm/sq]
SECT. 240,0
[mm/sq]
INT.PLATE X - Y
[mm]
GUB Threads comparation table
SIZE UNI 6125 ISO 228/1 ASA B2.1 ISO 965/I
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EMH9
EMH9Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
Feam Catalogue 01 - 113
Ex Enclosures
On Request Accessories:
•	External epoxy painting with colour on request
•	Internal anticondensate painting
Mechanical characteristics
Body	 marine grade copper free aluminum
Cover	 marine grade copper free aluminum
Round window	 thransparent tempered glass
Gasket	 NBR O-Ring sealing
INSTRUMENT HOUSING
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d IIC T6 / T5
II 2 D Ex tD A21 T85°C / T100°C
1 Ex d IIC T6, T5 X
DIP A21 TA 85°C...100°C
1 Ex d IIC T6, T5 X
DIP A21 TA 85°C...100°C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 02 ATEX 0069X POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 61241-0; EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
INSTRUMENT HOUSING
YOUR PARTNER FOR SAFETY
Since 1961
EMH9
A
B
E
ØH
D
C
GK3/4”
GK3/4”
FG
A
114 - Feam Catalogue 01
Ex Enclosures
EMH9 Technical features
Reference details
REMARK:
Due to the development of the national and international specifications and of the technology, the above technical characteristics showed
on this bulletin can be considered as binding on our confirmation only.
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
ØH
[mm]
WEIGHT
[Kg]
THREADED
ENTRY
DRAIN
VALVE
DETAIL
EMH9.2	 126	 125	 140	 152	 /	 22	 81	 90	 1,50	 1 x 3/4”	 NO	 A
EMH9.22	 126	 125	 140	 152	 164	 22	 81	 90	 1,50	 2 x 3/4”	 NO	 A
EMH9.2V	 126	 125	 140	 152	 /	 22	 81	 90	 1,50	 1 x 3/4”	 YES	 A
EMH9.22V	 126	 125	 140	 152	 164	 22	 81	 90	 1,50	 2 x 3/4”	 YES	 A
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
GUA-EAHF
GUA - EAHF
EAHF
GUA
Feam Catalogue 01 - 115
Ex Enclosures
JUNCTION
AND PULLING BOXES
On Request Accessories:
•	External epoxy painting with colour on request
•	Internal anticondensate painting orange RAL-2004
Mechanical characteristics
Body marine grade copper free aluminum
Cover marine grade copper free aluminum
Screws external - stainless steel
Gasket O-Ring sealing NBR
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
JUNCTION AND PULLING BOXES
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d IIC T6 / T3
II 2 D Ex tD A21 T85°C / T150°C
1 Ex d IIC T6 T85°C o 1 Ex d IIC U
DIP A21 TA 85°C o DIP A21
1 Ex d IIC T6 T85°C o 1 Ex d IIC U
DIP A21 TA 85°C o DIP A21
AMBIENT TEMPERTURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +52°C
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 03 ATEX 0048 POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 61241-0; EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
GUA-EAHF
GUA…16	 87	 77	 100	 75	 40	 70	 70	 7	 0,60	 A
GUA…17	 113	 100	 130	 79	 50	 95	 82	 9	 0,90	 A
GUA…26	 87	 77	 100	 75	 40	 70	 70	 7	 0,60	 A
GUA…27	 113	 100	 130	 79	 50	 95	 82	 9	 0,90	 A
GUA…36	 87	 77	 100	 75	 40	 70	 70	 7	 0,60	 A
GUA…37	 113	 100	 130	 79	 50	 95	 82	 9	 0,90	 A
GUA…59	 154	 135	 169	 110	 75	 100	 130	 7,5	 1,20	 A
GUA…69	 154	 135	 169	 110	 75	 100	 130	 7,5	 1,20	 A
EAHF26	 87	 77	 110	 79	 61	 30	 85	 7	 0,50	 B
GUAB16 2 x 1/2"
GUAB17 2 x 1/2"
GUAB26 2 x 3/4"
GUAB27 2 x 3/4"
GUAB36 2 x 1"
GUAB37 2 x 1"
GUAB59 2 x 1-1/2"
GUAB69 2 x 2"
GUAL16 2 x 1/2"
GUAL17 2 x 1/2"
GUAL26 2 x 3/4"
GUAL27 2 x 3/4"
GUAL36 2 x 1"
GUAL37 2 x 1"
GUAL59 2 x 1-1/2"
GUAL69 2 x 2"
GUAC16 2 x 1/2"
GUAC17 2 x 1/2"
GUAC26 2 x 3/4"
GUAC27 2 x 3/4"
GUAC36 2 x 1"
GUAC37 2 x 1"
GUAC59 2 x 1-1/2"
GUAC69 2 x 2"
GUAT16 3 x 1/2"
GUAT17 3 x 1/2"
GUAT26 3 x 3/4"
GUAT27 3 x 3/4"
GUAT36 3 x 1"
GUAT37 3 x 1"
GUAT59 3 x 1-1/2"
GUAT69 3 x 2"
EAHF26 3 x 3/4"
GUAX16 4 x 1/2"
GUAX17 4 x 1/2"
GUAX26 4 x 3/4"
GUAX27 4 x 3/4"
GUAX36 4 x 1"
GUAX37 4 x 1"
GUAX59 4 x 1-1/2"
GUAX69 4 x 2"
GUAW16 4 x 1/2"
GUAW17 4 x 1/2"
GUAW26 4 x 3/4"
GUAW27 4 x 3/4"
GUAW36 4 x 1"
GUAW37 4 x 1"
GUAW59 4 x 1-1/2"
GUAW69 4 x 2"
GUAD16 3 x 1/2"
GUAD17 3 x 1/2"
GUAD26 3 x 3/4"
GUAD27 3 x 3/4"
GUAD36 3 x 1"
GUAD37 3 x 1"
GUAD59 3 x 1-1/2"
GUAD69 3 x 2"
FIGURAPOSIZIONE IMBOCCHI
1
2
3
4
5
FIGURAPOSIZIONE IMBOCCHI
1
2
3
4
5
6
7
FIGURAPOSIZIONE IMBOCCHI
1
2
3
4
5
FIGURAPOSIZIONE IMBOCCHI
1
2
3
4
5
6
7
FIGURAPOSIZIONE IMBOCCHI
1
2
3
4
5
FIGURAPOSIZIONE IMBOCCHI
1
2
3
4
5
6
7
FIGURAPOSIZIONE IMBOCCHI
1
2
3
4
5
95
ILEENER
GIZED
DONOT
OPENWH
C
G E
D
ØA
H
F
ØB
C
G
E
F
H
D
ØB
ØA
A B
116 - Feam Catalogue 01
Ex Enclosures
GUA - EAHF Technical features
GUA - EAHF Hubs arrangement
GUA - Reference details EAHF - Reference details
CODE
Ø A
[mm]
Ø B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
H
[mm]
WEIGHT [Kg] DETAIL
REFERENCE DETAILS COMPLETE
CODE HUBS REFERENCE DETAILS COMPLETE
CODE HUBS
Detail A
Detail E
Detail B
Detail F
Detail C
Detail G
Detail D
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
HANDLES
HANDLES
OPERATORS (PILOT LIGHTS - PUSH BUTTONS - HANDLES)
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d IIB+H2
II 2 D Ex tD A21
1 Ex d IIB+H2 / IIC T6…T3 1 Ex d IIB+H2 / IIC T6…T3
AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. - - -
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
Feam Catalogue 01 - 117
Ex Enclosures
OPERATORS
(PILOT LIGHTS -PUSH BUTTONS -HANDLES)
Mechanical characteristics
PILOT LIGHTS
Body marine grade copper free aluminium light alloy
Diffuser temperated glass / polycarbonate
ILLUMINATED PUSH BUTTONS
Body stainless steel
Protection ring nickel plated brass
Diffuser temperated glass
Transmission stainless steel AISI 316L
HANDLES
Body marine grade copper free aluminium light alloy
Transmission parts stainless steel AISI 316L
PUSH BUTTONS
Body stainless steel
Protection ring nickel plated brass
Button aluminium light alloy / polycarbonate
Transmission stainless steel AISI 316L
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
YOUR PARTNER FOR SAFETY
Since 1961
HANDLES	
118 - Feam Catalogue 01
Ex Enclosures
HANDLES Technical data
CODE
CONTACTS
DIAGRAM
PUSH BUTTON
COLOUR
THREAD SIZE
BODY
CODE
CONTACTS
DIAGRAM
PUSH BUTTON
COLOUR
THREAD SIZE
BODY
BACK COVER INSTALLATION PADLOCKABLE HANDLE (ELEBERG BRAND CONTACTS)
63÷250AMP SIZE PADLOCKABLE HANDLE (ALL POSITIONS)
CODE CONTACTS DIAGRAM SUPPLY LAMPHOLDER LAMP COLOUR THREAD SIZE BODY
REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
SPRING RETURN PUSH BUTTON WITH LAMP FOR BACK COVER INSTALLATION
PILOT LIGHT FOR BACK COVER INSTALLATION
SPRING RETURN PUSH BUTTON - CONTACTS 10AMP SPRING RETURN MUSHROOM PUSH BUTTON - CONTACTS 10AMP
RELEASE BY KEY STAY-PUT MUSHROOM PUSH BUTTON - CONTACTS 10AMP
TURN TO RELEASE STAY-PUT MUSHROOM PUSH BUTTON - CONTACTS 10AMP
EFP1#AZ1	 1 NO	 LIGHT BLUE	 1/2”
EFP1#AZ2	 1 NC	 LIGHT BLUE	 1/2”
EFP1#AZ3	 1 NO + 1 NC	 LIGHT BLUE	 1/2”
EFP1#AZ4	 2 NO	 LIGHT BLUE	 1/2”
EFP1#AZ5	 2 NC	 LIGHT BLUE	 1/2”
EFP1#BI1	 1 NO	 WHITE	 1/2”
EFP1#BI2	 1 NC	 WHITE	 1/2”
EFP1#BI3	 1 NO + 1 NC	 WHITE	 1/2”
EFP1#BI4	 2 NO	 WHITE	 1/2”
EFP1#BI5	 2 NC	 WHITE	 1/2”
EFP1#BL1	 1 NO	 BLUE	 1/2”
EFP1#BL2	 1 NC	 BLUE	 1/2”
EFP1#BL3	 1 NO + 1 NC	 BLUE	 1/2”
EFP1#BL4	 2 NO	 BLUE	 1/2”
EFP1#BL5	 2 NC	 BLUE	 1/2”
EFP1#GI1	 1 NO	 YELLOW	 1/2”
EFP1#GI2	 1 NC	 YELLOW	 1/2”
EFP1#GI3	 1 NO + 1 NC	 YELLOW	 1/2”
EFP1#GI4	 2 NO	 YELLOW	 1/2”
EFP1#GI5	 2 NC	 YELLOW	 1/2”
EFP1#NE1	 1 NO	 BLACK	 1/2”
EFP1#NE2	 1 NC	 BLACK	 1/2”
EFP1#NE3	 1 NO + 1 NC	 BLACK	 1/2”
EFP1#NE4	 2 NO	 BLACK	 1/2”
EFP1#NE5	 2 NC	 BLACK	 1/2”
EFP1#RO1	 1 NO	 RED	 1/2”
EFP1#RO2	 1 NC	 RED	 1/2”
EFP1#RO3	 1 NO + 1 NC	 RED	 1/2”
EFP1#RO4	 2 NO	 RED	 1/2”
EFP1#RO5	 2 NC	 RED	 1/2”
EFP1#VE1	 1 NO	 GREEN	 1/2”
EFP1#VE2	 1 NC	 GREEN	 1/2”
EFP1#VE3	 1 NO + 1 NC	 GREEN	 1/2”
EFP1#VE4	 2 NO	 GREEN	 1/2”
EFP1#VE5	 2 NC	 GREEN	 1/2”
EFP1F#1	 1 NO	 RED	 1/2”
EFP1F#2	 1 NC	 RED	 1/2”
EFP1F#3	 1 NO + 1 NC	 RED	 1/2”
EFP1F#4	 2 NO	 RED	 1/2”
EFP1F#5	 2 NC	 RED	 1/2”
EFP1FSC#NE1	 1 NO	 BLACK	 1/2”
EFP1FSC#NE2	 1 NC	 BLACK	 1/2”
EFP1FSC#NE3	 1 NO + 1 NC	 BLACK	 1/2”
EFP1FSC#NE4	 2 NO	 BLACK	 1/2”
EFP1FSC#NE5	 2 NC	 BLACK	 1/2”
EFP1FSC#RO1	 1 NO	 RED	 1/2”
EFP1FSC#RO2	 1 NC	 RED	 1/2”
EFP1FSC#RO3	 1 NO + 1 NC	 RED	 1/2”
EFP1FSC#RO4	 2 NO	 RED	 1/2”
EFP1FSC#RO5	 2 NC	 RED	 1/2”
EFP1FSR#GI1	 1 NO	 YELLOW	 1/2”
EFP1FSR#GI2	 1 NC	 YELLOW	 1/2”
EFP1FSR#GI3	 1 NO + 1 NC	 YELLOW	 1/2”
EFP1FSR#GI4	 2 NO	 YELLOW	 1/2”
EFP1FSR#GI5	 2 NC	 YELLOW	 1/2”
EFP1FSR#NE1	 1 NO	 BLACK	 1/2”
EFP1FSR#NE2	 1 NC	 BLACK	 1/2”
EFP1FSR#NE3	 1 NO + 1 NC	 BLACK	 1/2”
EFP1FSR#NE4	 2 NO	 BLACK	 1/2”
EFP1FSR#NE5	 2 NC	 BLACK	 1/2”
EFP1FSR#RO1	 1 NO	 RED	 1/2”
EFP1FSR#RO2 	 1 NC	 RED	 1/2”
EFP1FSR#RO3	 1 NO + 1 NC	 RED	 1/2”
EFP1FSR#RO4	 2 NO	 RED	 1/2”
EFP1FSR#RO5	 2 NC	 RED	 1/2”
EFI-RL		 -	 -	 -	 BLACK	 1/2”
EFI-RC	(with key)	 -	 -	 -	 BLACK	 1”
EFISL 		 -	 -	 -	 BLACK	 3/8”
EFLP3#BL1	 1NO	 12V ÷ 380V ac/dc	 Ba-9s	 BLUE	 M32
EFLP3#BL3	 1NO + 1NC	 12V ÷ 380V ac/dc	 Ba-9s	 BLUE	 M32
EFLP3#GI2	 1NC	 12V ÷ 380V ac/dc	 Ba-9s	 YELLOW	 M32
EFLP3#GI3	 1NO + 1NC	 12V ÷ 380V ac/dc	 Ba-9s	 YELLOW	 M32
EFLP3#RO1	 1NO	 12V ÷ 380V ac/dc	 Ba-9s	 RED	 M32
EFLP3#RO2	 1NC	 12V ÷ 380V ac/dc	 Ba-9s	 RED	 M32
EFLP3#RO3	 1NO + 1NC	 12V ÷ 380V ac/dc	 Ba-9s	 RED	 M32
EFLP3#VE1	 1NO	 12V ÷ 380V ac/dc	 Ba-9s	 GREEN	 M32
EFLP3#VE3	 1NO + 1NC	 12V ÷ 380V ac/dc	 Ba-9s	 GREEN	 M32
EFL1#AZ	 -	 12V ÷ 380V ac/dc	 Ba-9s	 LIGHT BLUE	 1/2”
EFL1#BI	 -	 12V ÷ 380V ac/dc	 Ba-9s	 WHITE	 1/2”
EFL1#BL	 -	 12V ÷ 380V ac/dc	 Ba-9s	 BLUE	 1/2”
EFL1#GI	 -	 12V ÷ 380V ac/dc	 Ba-9s	 YELLOW	 1/2”
EFL1#RO	 -	 12V ÷ 380V ac/dc	 Ba-9s	 RED	 1/2”
EFL1#VE	 -	 12V ÷ 380V ac/dc	 Ba-9s	 GREEN	 1/2”
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
ESA
ESA
JUNCTION BOX
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex e II T5
II 2 G Ex e [ia] IIB/IIC T5
II 2 D Ex tD A21 T100°C
2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X,
2Ex e [ia] IIB/IIC T4, T5 X
DIP A21 TA 100°C
2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X,
2Ex e [ia] IIB/IIC T4, T5 X
DIP A21 TA 100°C
AMBIENT TEMPERATURE -50°C ÷ +175°C -50°C ÷ +175°C -50°C ÷ +175°C
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 02 ATEX 0067X POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-7;
EN 60079-11; 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
On Request Accessories:
•	External epoxy painting with colour on request
• Internal anticondensate painting orange RAL-2004
• Drain and breather valves
Mechanical characteristics
Body marine grade copper free aluminium light alloy
Cover marine grade copper free aluminium light alloy
Screws stainless steel AISI 316L
Internal plate hot dip galvanized steel
Gasket silicon rubber
Feam Catalogue 01 - 119
Ex Enclosures
JUNCTION BOXES
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts)
Classification: Group II - Category 2G 2D
YOUR PARTNER FOR SAFETY
Since 1961
ESA
ESA1313	 130	 130	 85	 115	 115	 71	 114	 114	 112 - 70	 1,20	 A
ESA1717	 170	 170	 95	 155	 155	 81	 154	 154	 150 - 150	 1,50	 A
ESA2216	 220	 160	 95	 205	 145	 81	 204	 144	 200 - 100	 3,80	 A
ESA2222	 220	 220	 110	 205	 205	 97	 204	 204	 200 - 160	 4,40	 A
ESA3322	 330	 220	 120	 312	 202	 103	 316	 206	 294 - 154	 6,40	 A
ESA3333	 330	 330	 130	 312	 312	 114	 316	 316	 290 - 290	 8,80	 A
ESA4433	 440	 330	 150	 420	 310	 155	 426	 316	 400 - 290	 11,40	 A
ESA5242	 520	 420	 180	 496	 396	 165	 506	 406	 460 - 370	 20,20	 A
ESA6348	 630	 480	 180	 610	 460	 165	 598	 466	 550 - 400	 21,30	 A
ESA1313	 88 x55	 2	 1	 1	 1	 /	 /	 /	 /
ESA1717	 150 x 70	 5	 3	 2	 2	 2	 1	 /	 /
ESA2216	 200 x 70	 6	 3	 3	 3	 2	 2	 /	 /
ESA2222	 200 x 85	 8	 5	 3	 3	 3	 2	 2	 /
ESA3322	 285 x 90	 12	 7	 6	 5	 4	 3	 3	 /
ESA3333	 275 x 90	 12	 7	 6	 5	 4	 3	 2	 /
ESA4433	 370 x 110	 20	 14	 12	 12	 6	 5	 3	 /
ESA5242	 420 x 145	 30	 18	 16	 12	 12	 8	 4	 2
ESA6348	 500 x 140	 36	 24	 18	 16	 12	 10	 6	 4
	 88 x55	 2	 1	 1	 1	 /	 /	 /	 /
	 150 x 70	 5	 3	 2	 2	 2	 1	 /	 /
	 120 x 70	 4	 2	 2	 2	 1	 1	 /	 /
	 200 x 85	 8	 5	 3	 3	 3	 2	 2	 /
	 200 x 90	 8	 5	 4	 4	 3	 2	 2	 /
	 275 x 90	 12	 7	 6	 5	 4	 3	 2	 /
	 265 x 110	 14	 10	 8	 8	 4	 3	 2	 /
	 360 x 145	 28	 18	 14	 11	 10	 7	 4	 3
	 400 x 140	 30	 21	 15	 12	 10	 8	 4	 3
A
F
C
B
GxH
DxE
A
B
C
D
ESA1313	 10 x 1	 5 x 1 	 4 x 1	 4 x 1	 3 x 1	 2 x 1	 1 x 1	 /	 112 - 70
ESA1717	 20 x 1	 10 x 1	 8 x 1	 8 x 1	 6 x 1	 3 x 1	 2 x 1	 1 x 1	 150 - 150
ESA2216	 30 x 1	 18 x 1	 14 x 1	 10 x 1	 8 x 1	 3 x 1	 2 x 1	 1 x 1	 200 - 200
ESA2222	 26 x 1	 16 x 1	 12 x 1	 10 x 1	 8 x 1	 4 x 1	 2 x 1	 2 x 1	 200 - 160
ESA3322	 46 x 1	 26 x 1	 22 x 1	 18 x 1	 14 x 1	 10 x 1	 6 x 1	 2 x 1	 294 - 154
ESA3333	 46 x 2	 24 x 2	 22 x 2	 16 x 2	 14 x 2	 10 x 1	 8 x 1	 3 x 1	 290 - 290
ESA4433	 70 x 2	 40 x 2	 32 x 2	 26 x 2	 20 x 2	 14 x 2	 10 x 1	 4 x 1	 400 - 290
ESA5242	 70 x 3	 44 x 3	 34 x 3	 30 x 3	 22 x 3	 18 x 2	 14 x 1	 6 x 1	 460 - 370
ESA6348	 90 x 3	 56 x 3	 44 x 3	 40 x 3	 28 x 3	 24 x 2	 20 x 1	 10 x 1	 550 - 400
A
120 - Feam Catalogue 01
Ex Enclosures
ESA Technical features
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
H
[mm]
INT. PLATE
X - Y [mm]
WEIGHT
[Kg]
DETAIL
Reference details Reference details
wall DRILLING AREA
ESA Body Enclosures Drilling Layout
ESA Indicative quantity of terminals and relevant section
ENCLOSURE
CODE
DRILLING AREA
A-B [mm]
QUANTITY ALLOWED ENTRIES FOR
SIZE (from 1 to size 8)
1 2 3 4 5 6 7 8
DRILLING AREA
A-B [mm]
QUANTITY ALLOWED ENTRIES FOR
SIZE (from 1 to size 8)
1 2 3 4 5 6 7 8
REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
CODE
ENCLOSURE
SECT. 2,5
[mm/sq]
SECT. 6,0
[mm/sq]
SECT. 10,0
[mm/sq]
SEZ. 16,0
[mm/sq]
SEZ. 35,0
[mm/sq]
SECT. 50,0
[mm/sq]
SECT. 70,0
[mm/sq]
SECT. 240,0
[mm/sq]
INT.PLATE X - Y
[mm]
plate X-Y
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
ESX
ESX
Feam Catalogue 01 - 121
Ex Enclosures
JUNCTION BOXES
On Request Accessories:
•	External epoxy painting with colour on request
•	Internal anticondensate painting orange RAL-2004
•	Drain and breather valves
•	Removable flanges on side walls (see identification table)
Mechanical characteristics
Body stainless steel AISI-316L - th. 1,5mm
Cover stainless steel AISI-316L - th. 1,5mm
Screws stainless steel AISI 316L
Internal plate stainless steel AISI-316L - th. 1,5mm
Gasket silicon rubber
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
JUNCTION BOX
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex e II T5
II 2 G Ex e [ia] IIB/IIC T5
II 2 D Ex tD A21 T100°C
2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X,
2Ex e [ia] IIB/IIC T4, T5 X
DIP A21 TA 100°C
2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X,
2Ex e [ia] IIB/IIC T4, T5 X
DIP A21 TA 100°C
AMBIENT TEMPERATURE -50°C ÷ +175°C -50°C ÷ +175°C -50°C ÷ +175°C
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 02 ATEX 0067X POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-7;
EN 60079-11; 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
ESX
A
E
C
G
G1
HxI
B
D
D1
F
ESX-1313 130 130 205 - 88 180 53 - 53 127 127 80-80 1,00 A
ESX-1717 170 170 245 - 88 220 90 - 53 167 167 128-128 2,00 A
ESX-2212 220 120 295 - 88 270 50 - 53 217 117 178-78 2,50 A
ESX-2216(1) 220 165 295 148 88 270 85 113 53 217 162 178-118 3,00 A
ESX-2222(1) 220 220 295 148 88 270 140 113 53 217 217 170-170 4,00 A
ESX-3322(1) 330 220 405 148 108 380 140 113 73 327 217 280-170 5,00 A
ESX-3333(1) 330 330 405 148 108 380 250 113 73 327 327 280-280 6,80 A
ESX-4422 440 220 515 148 - 490 140 113 - 437 217 398-178 7,00 A
ESX-4433 440 330 515 148 - 490 250 113 - 437 327 390-290 8,50 A
ESX-4936 490 360 560 148 - 534 280 113 - 487 357 440-315 9,50 A
ESX-5242(1) 520 420 595 242 148 570 340 206 113 517 417 470-370 12,00 A
ESX-6348 630 480 705 - 148 680 400 113 - 627 477 580-430 16,00 A
ESX-7440(1) 745 400 820 227 148 795 320 191 113 742 397 695-350 18,00 A
A
122 - Feam Catalogue 01
ESX Flanges (gland plates) identification table
Standard availability in stock for enclosures without flanges
Please refer to below diagram to define quntity and position of side walls flanges
FC = flange on short side enclosure FL = Flange On Long Side Enclosure
Number 1 or 2 placed before sentence FC or FL define flange quantities. ATTENTION: on each enclosure side wall is allowed one single flange only
Example:
ESX-3322A-1FC-2FL= Enclosure Dim. 330x220x148mm with 1 flange only on 1 short side + 2 flanges one on each long side
ESX-5242A-2FC-2FL= enclosure Dim. 520x420x242mm with 2 flanges one on each short side + 2 flanges one on each long side
Ex Enclosures
ESX Technical Features
Reference Details
(1) ENCLOSURE DEEP: A = HIGH (see column D) - B = LOW (see column D1) 					
SAMPLE: ESX-2222A = ENCLOSURE DIM. 220x220x148 mm / ESX-2216B = ENCLOSURE DIM. 220x165x88 mm			
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
D1
[mm]
E
[mm]
F
[mm]
G
[mm]
*G1
[mm]
H
[mm]
I
[mm]
INT.PLATE
X-Y [mm]
WEIGHT
[Kg]
DETAIL
YOUR PARTNER FOR SAFETY
Since 1961
ESX
NOTE:
Per tenere conto dell’evoluzione della normativa nazionale ed internazionale e della tecnologia, le caratteristiche riportate in questa
scheda tecnica possono ritenersi impegnative solo dopo nostra conferma.
ESX-2216A 180 - 85 8 5 4 3 2 2 1 /
ESX-2222A 180 - 85 8 5 4 3 2 2 1 /
ESX-3322A 290 - 85 12 8 7 4 4 3 3 /
ESX-3333A 290 - 85 12 8 7 4 4 3 3 /
ESX-4422 400 - 85 16 11 9 7 6 5 4 /
ESX-4433 400 - 85 16 11 9 7 6 5 4 /
ESX-4936 450 - 85 18 13 11 8 6 5 4 /
ESX-5242B 480 - 85 20 14 11 8 7 6 4 /
ESX-5242A 480 - 178 40 28 22 16 14 12 8 4
ESX-6348 590 - 85 24 17 14 10 9 7 5 /
ESX-7440B 705 - 85 30 21 17 13 10 8 6 /
ESX-7440A 705 - 163 53 38 34 26 20 14 9 6
125 - 85 6 3 2 2 1 1 1 /
180 - 85 8 5 4 3 2 2 1 /
180 - 85 8 5 4 3 2 2 1 /
290 - 85 12 8 7 4 4 3 3 /
290 - 85 12 8 7 4 4 3 3 /
290 - 85 12 8 7 4 4 3 3 /
320 - 85 14 9 7 5 4 3 3 /
380 - 85 16 11 9 7 5 4 3 /
380 - 178 32 22 18 14 10 8 6 3
440 - 85 18 13 10 8 6 5 4 /
360 - 85 14 10 8 6 5 4 3 /
360 163 25 18 16 12 10 8 4 3
ESX-2216 214 159 / 119
ESX-2222 214 214 / 119
ESX-3322 324 214 / 119
ESX-3333 324 324 / 119
ESX-4422 434 214 / 119
ESX-4433 434 324 / 119
ESX-4936 484 359 / 119
ESX-5242(1) 514 414 212,5 119
ESX-6348 624 474 / 119
ESX-7440(1) 739 394 197,5 119
TIPO
CUSTODIA
SEZ. 2,5
[mm/sq]
SEZ. 6,0
[mm/sq]
SEZ. 10,0
[mm/sq]
SEZ. 16,0
[mm/sq]
SEZ. 35,0
[mm/sq]
SEZ. 50,0
[mm/sq]
SEZ. 70,0
[mm/sq]
SEZ. 240,0
[mm/sq]
ВНУТР.
ПЛАСТИНА
ESX-1313 3 x 1 3 x 1 2 x 1 2 x 1 2 x 1 1 x 1 1 x 1 / 80 - 80
ESX-1717 20 x 1 10 x 1 10 x 1 6 x 1 6 x 1 4 x 1 2 x 1 1 x 1 128 - 128
ESX-2212 28 x 1 16 x 1 12 x 1 10 x 1 8 x 1 6 x 1 4 x 1 / 178 - 78
ESX-2216(1) 30 x1 18 x 1 14 x 1 10 x 1 8 x 1 3 x 1 2 x 1 1 x 1 178 - 118
ESX-2222(1) 20 x 1 14 x 1 10 x 1 8 x 1 6 x 1 6 x 1 4 x 1 2 x 1 170 - 170
ESX-3322(1) 46 x 1 26 x 1 22 x 1 18 x 1 14 x 1 10 x 1 6 x 1 2 x 1 280 - 170
ESX-3333(1) 48 x 2 28 x 2 24 x 2 20 x 2 12 x 2 10 x 2 8 x 1 4 x 1 280 - 280
ESX-4422 70 x 1 44 x 1 34 x 1 30 x 1 22 x 1 18 x 1 14 x 1 6 x 1 398 - 178
ESX-4433 60 x 2 40 x 2 32 x 2 26 x 2 20 x 2 14 x 2 10 x 1 4 x 1 390 - 290
ESX-4936 70 x 2 44 x 2 36 x 2 30 x 2 22 x 2 18 x 2 14 x 1 8 x 1 440 - 315
ESX-5242(1) 70 x 3 44 x 3 34 x 13 30 x 3 22 x 3 18 x 2 14 x 1 6 x 1 470 - 370
ESX-6348 100 x 3 60 x 3 50 x 3 40 x 3 30 x 3 26 x 3 20 x 2 10 x 1 580 - 430
ESX-7440(1) 120 x 3 76 x 3 60 x 3 50 x 3 34 x 3 30 x 2 24 x 1 12 x 1 695 - 350
E
G
G1
F
G
G1
A C
B
D
ESX-1313 3 x 1 3 x 1 2 x 1 2 x 1 2 x 1 1 x 1 1 x 1 / 80 - 80
ESX-1717 20 x 1 10 x 1 10 x 1 6 x 1 6 x 1 4 x 1 2 x 1 1 x 1 128 - 128
ESX-2212 28 x 1 16 x 1 12 x 1 10 x 1 8 x 1 6 x 1 4 x 1 / 178 - 78
ESX-2216(1) 30 x1 18 x 1 14 x 1 10 x 1 8 x 1 3 x 1 2 x 1 1 x 1 178 - 118
ESX-2222(1) 20 x 1 14 x 1 10 x 1 8 x 1 6 x 1 6 x 1 4 x 1 2 x 1 170 - 170
ESX-3322(1) 46 x 1 26 x 1 22 x 1 18 x 1 14 x 1 10 x 1 6 x 1 2 x 1 280 - 170
ESX-3333(1) 48 x 2 28 x 2 24 x 2 20 x 2 12 x 2 10 x 2 8 x 1 4 x 1 280 - 280
ESX-4422 70 x 1 44 x 1 34 x 1 30 x 1 22 x 1 18 x 1 14 x 1 6 x 1 398 - 178
ESX-4433 60 x 2 40 x 2 32 x 2 26 x 2 20 x 2 14 x 2 10 x 1 4 x 1 390 - 290
ESX-4936 70 x 2 44 x 2 36 x 2 30 x 2 22 x 2 18 x 2 14 x 1 8 x 1 440 - 315
ESX-5242(1) 70 x 3 44 x 3 34 x 13 30 x 3 22 x 3 18 x 2 14 x 1 6 x 1 470 - 370
ESX-6348 100 x 3 60 x 3 50 x 3 40 x 3 30 x 3 26 x 3 20 x 2 10 x 1 580 - 430
ESX-7440(1) 120 x 3 76 x 3 60 x 3 50 x 3 34 x 3 30 x 2 24 x 1 12 x 1 695 - 350
Feam Catalogue 01 - 123
Ex Enclosures
ESX Removable flanges drilling layout
ESX Removable flanges dimensions
ESX Indicative quantity of terminals and relevant section
Reference DetailsCODE E [mm] F [mm] G [mm] G1 [mm]
(1) ENCLOSURE DEEP: A = HIGH (see column C) - B = LOW (see column C1) / SAMPLE: ESX-5242A = ENCLOSURE DIM. 520x420x242 mm
(1) ENCLOSURE DEEP: A = HIGH - B = LOW (see Technical Feature table) 						
flangeS
flanges DRILLING AREA
CODE
ENCLOSURE
SECT. 2,5
[mm/sq]
SECT. 6,0
[mm/sq]
SECT. 10,0
[mm/sq]
SECT. 16,0
[mm/sq]
SECT. 35,0
[mm/sq]
SECT. 50,0
[mm/sq]
SECT. 70,0
[mm/sq]
SECT. 240,0
[mm/sq]
INT.PLATE
X - Y [mm]
ENCLOSURE
CODE
DRILLING
AREA
A-B [mm]
QUANTITY ALLOWED ENTRIES FOR
SIZE (from 1 to size 8)
1 2 3 4 5 6 7 8
DRILLING
AREA
C-D [mm]
QUANTITY ALLOWED ENTRIES FOR
SIZE (from 1 to size 8)
1 2 3 4 5 6 7 8
YOUR PARTNER FOR SAFETY
Since 1961
ESX
ESX-1313 117 - 44 2 2 / / / / / /
ESX-1717 160 - 44 3 3 / / / / / /
ESX-2212 210 - 44 4 4 / / / / / /
ESX-2216B 210 - 44 4 4 / / / / / /
ESX-2216A 210 - 100 8 8 6 5 3 2 2 1
ESX-2222B 210 - 44 4 4 / / / / / /
ESX-2222A 210 - 100 8 8 6 5 3 2 2 1
ESX-3322B 320 - 64 9 6 5 5 4 / / /
ESX-3322A 320 - 100 12 12 10 8 4 4 3 2
ESX-3333B 320 - 64 9 6 5 5 4 / / /
ESX-3333A 320 - 100 12 12 10 8 4 4 3 2
ESX-4422 430 - 100 16 16 14 11 7 5 4 3
ESX-4433 430 - 100 16 16 14 11 7 5 4 3
ESX-4936 480 - 100 20 18 15 12 8 6 4 4
ESX-5242B 510 - 100 22 18 16 13 8 6 5 4
ESX-5242A 510 - 195 44 27 24 21 16 14 10 5
ESX-6348 620 - 100 29 22 20 16 10 7 6 5
ESX-7440B 735 - 100 33 26 24 18 12 9 7 5
ESX-7440A 735 - 180 55 43 38 33 20 18 14 7
A
B
C
D
117 - 44 2 2 / / / / / /
160 - 44 3 3 / / / / / /
110 - 44 2 2 / / / / / /
155 - 44 3 3 / / / / / /
155 - 100 6 6 4 3 2 2 1 1
210 - 44 4 4 / / / / / /
210 - 100 8 8 6 5 3 2 2 1
210 - 64 6 4 3 3 2 / / /
210 - 100 8 8 6 5 3 2 2 1
320 - 64 9 6 5 5 4 / / /
320 - 100 12 12 10 8 4 4 3 2
210 - 100 8 8 6 5 3 2 2 1
320 - 100 12 12 10 8 4 4 3 2
350 - 100 14 14 10 8 5 4 3 3
410 - 100 18 14 13 10 7 5 4 3
410 - 195 36 21 18 15 12 11 8 4
470 - 100 21 16 15 12 7 5 4 3
390 - 100 18 14 12 9 6 4 3 3
390 - 180 30 23 20 15 9 8 6 3
1	 GK 1/2”	 G 1/2”	 1/2” NPT	 M20
2	 GK 3/4”	 G 3/4”	 3/4” NPT	 M25
3	 GK 1”	 G 1”	 1” NPT	 M32
4	 GK 1-1/4”	 G 1-1/4”	 1-1/4” NPT	 M40
5	 GK 1-1/2”	 G 1-1/2”	 1-1/2” NPT	 M50
6	 GK 2”	 G 2”	 2” NPT	 M63
7	 GK 2-1/2”	 G 2-1/2”	 2-1/2” NPT	 M75
8	 GK 3”	 G 3”	 3” NPT	 M85
124 - Feam Catalogue 01
Ex Enclosures
ESX Body Enclosures Drilling Layout
ENCLOSURE
CODE
DRILLING
AREA A-B
[mm]
QUANTITY ALLOWED ENTRIES FOR
SIZE (from 1 to size 8)
1 2 3 4 5 6 7 8
Reference Details Reference Details
body DRILLING AREA plate
DRILLING
AREA C-D
[mm]
QUANTITY ALLOWED ENTRIES FOR
SIZE (from 1 to size 8)
1 2 3 4 5 6 7 8
REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
SIZE UNI 6125 ISO 228/1 ASA B2.1 ISO 965/I
ESX Threads comparation table
PLATE
X-Y
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
GWR
GWR
Feam Catalogue 01 - 125
Ex Enclosures
GLASS FIBRE
REINFORCED POLYESTER RESIN
JUNCTION BOXES
On Request Accessories:
• Drain and breather valves
Mechanical characteristics	
Body glass fibre reinforced polyester resin
Cover glass fibre reinforced polyester resin
Screws external - stainless steel
Internal plate aluminium
Gasket hot dip galvanized steel
Strenght 4 Joule impact resistance
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
JUNCTION BOX
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex e II T6
II 2 D Ex tD A21 T85°C
2Ex e II T6
DIP A21 TA 85°C
2Ex e II T6
DIP A21 TA 85°C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. LOM 02 ATEX 2024 POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1; EN 60079-7;
EN 61241-0; EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
GWR
NONAPRIRESOTTOTENSIONE-DONOTOPENWHILEENERGIZED
B
A
C
GxH
D
C
A
B
D
F
E
GWR11	 64 x 52	 1	 1	 1	 1	 -	 -	 -	 -
GWR14	 90 X 52	 2	 1	 1	 1	 -	 -	 -	 -
GWR21	 108 - 85	 4	 2	 2	 2	 1	 1	 1	 -
GWR22	 108 - 85	 4	 2	 2	 2	 1	 1	 1	 -
GWR42	 278 - 85	 12	 7	 5	 5	 4	 3	 2	 -
GWR44	 310 - 85	 12	 8	 7	 5	 4	 4	 3	 -
GWR84	 640 - 115	 35	 23	 20	 17	 13	 9	 7	 5
	 64 x 52	 1	 1	 1	 1	 -	 -	 -	 -
	 90 X 52	 2	 1	 1	 1	 -	 -	 -	 -
	 37 - 85	 2	 -	 -	 -	 -	 -	 -	 -
	 108 - 85	 4	 2	 2	 2	 1	 1	 1	 -
	 125 - 85	 5	 3	 2	 2	 1	 1	 1	 -
	 125 - 85	 5	 3	 2	 2	 1	 1	 1	 -
	 310 - 115	 17	 11	 9	 8	 6	 4	 3	 2
GWR11N 110 110 84 96 96 53 102 102 - 0,30 A
GWR14N 140 140 84 124 124 53 132 132 - 0,40 A
GWR21(1) 175 87,5 120 123 72 88 165 77,5 - 0,88 A
GWR22(1) 175 175 120 162 123 88 165 165 135 - 135 1,25 A
GWR42(1) 360 175 120 308 162 88 352 165 320 - 135 2,50 A
GWR44(1) 360 360 120 346 308 88 352 352 320 - 320 3,40 A
GWR84(1) 730 360 166 670 340 120 720 350 670 - 310 8,00 A
GWR11 12 x 1 8 x 1 6 x 1 5 x 1 3 x 1 3 x 1 1 x 1 1 x 1 -
GWR14 18 x 1 10 x 1 8 x 1 7 x 1 5 x 1 4 x 1 2 x 1 1 x 1 -
GWR21 18 x 1 10 x 1 8 x 1 7 x 1 5 x 1 4 x 1 2 x 1 1 x 1 -
GWR22 20 x 1 10 x 1 10 x 1 6 x 1 6 x 1 4 x 1 2 x 1 1 x 1 135 - 135
GWR42 48 x 1 28 x 1 24 x 1 20 x 1 12 x 1 10 x 1 4 x 1 2 x 1 320 - 135
GWR44 48 x 2 28 x 2 24 x 2 20 x 2 12 x 2 10 x 2 8 x 1 4 x 1 320 - 320
GWR84 120 x 2 70 x 2 60 x 2 50 x 2 44 x 2 30 x 2 20 x 1 14 x 1 670 - 310
A
126 - Feam Catalogue 01
Ex Enclosures
GWR Technical Features
GWR Body Enclosures Drilling Layout
gwr Indicative quantity of terminals and relevant section
ENCLOSURE
CODE
DRILLING AREA
A-B [mm]
QUANTITY ALLOWED ENTRIES FOR
SIZE (from 1 to size 8)
1 2 3 4 5 6 7 8
DRILLING AREA
A-B [mm]
QUANTITY ALLOWED ENTRIES FOR
SIZE (from 1 to size 8)
1 2 3 4 5 6 7 8
Reference Details Reference Details
wall DRILLING AREA
REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
H
[mm]
INT. PLATE
X - Y [mm]
WEIGHT
[Kg] DETAIL
CODE
ENCLOSURE
SECT. 2,5
[mm/sq]
SECT. 6,0
[mm/sq]
SECT. 10,0
[mm/sq]
SECT. 16,0
[mm/sq]
SECT. 35,0
[mm/sq]
SECT. 50,0
[mm/sq]
SECT. 70,0
[mm/sq]
SECT.240,0
[mm/sq]
INT.PLATE X - Y
[mm]
(1) ENCLOSURE’S COLOUR: N = DARK GREY RAL7021 - B = LIGHT BLUE RAL5015 / EXAMPLE: GWR14N = COLOUR DARK GREY RAL 7021 GWR42B = COLOUR LIGHT BLUE RAL5015
PLATE
X-Y
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
GWRCS-ESX
GWRCS - ESX
Feam Catalogue 01 - 127
Ex Enclosures
Mechanical characteristics - GWRCS
Body glass fibre reinforced polyester resin color dark grey RAL 7021
Cover glass fibre reinforced polyester resin color dark grey RAL 7021
Screws stainless steel
Internal plate stainless steel - aluminium
Gasket silicon
Strenght 4 Joule impact resistance
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
GRP and STAINLESS STEEL
Ex-de PUSH BUTTON STATIONS
On Request Accessories:
•	External epoxy painting with colour on request
•	Internal anticondensate painting orange RAL 2004 (ESX)
•	Drain and breather valves
•	Removable flanges (only stainless steel enclosures)
Mechanical characteristics - ESX
Body stainless steel AISI 316l sp. 1,5mm
Cover stainless steel AISI 316l sp. 1,5mm
Screws stainless steel AISI 316L
Internal plate stainless steel AISI 316L
Gasket silicon
Strenght 4 Joule di resistenza all'urto
JUNCTION BOX FOR CONTROL. SWITCHGEAR and SIGNALLING - GWRCS
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex ed IIC T6
II 2 D Ex tD A21 T85°C
2Ex ed IIC T6
DIP A21 TA 85°C
2Ex ed IIC T6
DIP A21 TA 85°C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. LOM 02 ATEX 2024 POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-7; EN 61241-0;
EN 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
JUNCTION BOX FOR CONTROL. SWITCHGEAR and SIGNALLING - ESX
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex e II T5
II 2 G Ex e [ia] IIB/IIC T5
II 2 D Ex tD A21 T100°C
2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X,
2Ex e [ia] IIB/IIC T4, T5 X
DIP A21 TA 100°C
2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X,
2Ex e [ia] IIB/IIC T4, T5 X
DIP A21 TA 100°C
AMBIENT TEMPERATURE -50°C ÷ +175°C -50°C ÷ +175°C -50°C ÷ +175°C
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 02 ATEX 0067X POCC IT. ГБ05.B02537 No. 07/43-269
RULES OF COMPLIANCE
EN 60079-0; EN 60079-7;
EN 60079-11; 61241-1
ГОСТ Р 51330.9-99 (МЭК 60079-10-95)
ГОСТ Р 51330.13-99 (МЭК 60079-14-96)
ГОСТ Р МЭК 61241-3-99
ГОСТ Р 51330.0 / 1 / 8 / 14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
GWRCS-ESX
NPOT
S
Y CN EG R
EME
S
UAT
O
T
POT
S
Y CN EG R
EME
S
UA
ON
T
OPOT
S
Y CN EG R
EME
S
UA
N
T
POT
S
Y CN EG R
EME
S
UA
ON
T
POT
S
Y CN EG R
EME
S
UA
ON
220
A A A
A
10 10 10 10 10 10
10
10
10 10 10
A
10
10
520242
165148.5
330148.5
120 359.5 120
120 175
175
360
175
359.5
420
ESX 5242
ESX 2216 ESX 3333
GWRCS 44 GWRCS 42
GWRCS 22
NPOT
S
Y CN EG R
EME
S
UAT
O
T
POT
S
Y CN EG R
EME
S
UA
ON
T
OPOT
S
Y CN EG R
EME
S
UA
N
T
POT
S
Y CN EG R
EME
S
UA
ON
T
POT
S
Y CN EG R
EME
S
UA
ON
220
A A A
A
10 10 10 10 10 10
10
10
10 10 10
A
10
10
520242
165148.5
330148.5
120 359.5 120
120 175
175
360
175
359.5
420
ESX 5242
ESX 2216 ESX 3333
GWRCS 44 GWRCS 42
GWRCS 22
NPOT
S
Y CN EG R
EME
S
UAT
O
T
POT
S
Y CN EG R
EME
S
UA
ON
T
OPOT
S
Y CN EG R
EME
S
UA
N
T
POT
S
Y CN EG R
EME
S
UA
ON
T
POT
S
Y CN EG R
EME
S
UA
ON
220
A A A
A
10 10 10 10 10 10
10
10
10 10 10
A
10
10
520242
165148.5
330
330
148.5
120 359.5 120
120 175
175
360
175
359.5
420
ESX 5242
ESX 2216 ESX 3333
GWRCS 44 GWRCS 42
GWRCS 22
NPOT
S
Y CN EG R
EME
S
UAT
O
T
POT
S
Y CN EG R
EME
S
UA
ON
T
OPOT
S
Y CN EG R
EME
S
UA
N
T
POT
S
Y CN EG R
EME
S
UA
ON
T
POT
S
Y CN EG R
EME
S
UA
ON
220
A A A
A
10 10 10 10 10 10
10
10
10 10 10
A
10
10
520242
165148.5
330
330
148.5
120 359.5 120
120 175
175
360
175
359.5
420
ESX 5242
ESX 2216 ESX 3333
GWRCS 44 GWRCS 42
GWRCS 22
NPOT
S
Y CN EG R
EME
S
UAT
O
T
POT
S
Y CN EG R
EME
S
UA
ON
T
OPOT
S
Y CN EG R
EME
S
UA
N
T
POT
S
Y CN EG R
EME
S
UA
ON
T
POT
S
Y CN EG R
EME
S
UA
ON
220
A A A
A
10 10 10 10 10 10
10
10
10 10 10
A
10
10
520242
165148.5
330
330
148.5
120 359.5 120
120 175
175
360
175
359.5
420
ESX 5242
ESX 2216 ESX 3333
GWRCS 44 GWRCS 42
GWRCS 22
NPOT
S
Y CN EG R
EME
S
UAT
O
T
POT
S
Y CN EG R
EME
S
UA
ON
T
OPOT
S
Y CN EG R
EME
S
UA
N
T
POT
S
Y CN EG R
EME
S
UA
ON
T
POT
S
Y CN EG R
EME
S
UA
ON
220
A A A
A
10 10 10 10 10 10
10
10
10 10 10
A
10
10
520242
165148.5
330
330
148.5
120 359.5 120
120 175
175
360
175
359.5
420
ESX 5242
ESX 2216 ESX 3333
GWRCS 44 GWRCS 42
GWRCS 22
GWRCS 44
ESX 5242
GWRCS 22
ESX 3333
GWRCS 42
ESX 2216
128 - Feam Catalogue 01
Ex Enclosures
GWRCS - ESX Typical installation
REMARK:
Due to the development of the national and international specifications and of the technology, the above technical characteristics showed
on this bulletin can be considered as binding on our confirmation only.
GWRCS - ESX examples of application
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
ES
ES
Feam Catalogue 01 - 129
Waterproof Enclosures
JUNCTION BOXES
On Request Accessories:
•	External epoxy painting with colour on request
•	Internal anticondensate painting orange RAL-2004
•	Drain and breather valves
Mechanical characteristics
Body marine grade copper free aluminium light alloy
Cover marine grade copper free aluminium light alloy
Screws stainless steel
Internal plate hot dip galvanized steel / aluminium
Gasket silicon rubber
Installation: Safe Areas
Classification: IP66
JUNCTION BOX
CEI / EN
EXECUTION INDUSTRIAL WATERPROOF
AMBIENT TEMPERATURE -
PROTECTION DEGREE IP66
CERTIFICATE REF. -
RULES OF COMPLIANCE EN 60529
YOUR PARTNER FOR SAFETY
Since 1961
ES
ES1313 130 130 85 115 115 71 114 114 112 - 70 1,20 A
ES1717 170 170 95 155 155 81 154 154 150 - 150 1,50 A
ES2216 220 160 95 205 145 81 204 144 200 - 100 3,80 A
ES2222 220 220 110 205 205 97 204 204 200 - 160 4,40 A
ES3322 330 220 120 312 202 103 316 206 294 - 154 6,40 A
ES3333 330 330 130 310 310 114 316 316 290 - 290 8,80 A
ES4433 440 330 150 420 310 155 426 316 400 - 290 11,40 A
ES5242 520 420 180 496 396 165 506 406 460 - 370 20,20 A
ES6348 630 480 180 610 460 165 598 466 550 - 400 21,30 A
A
F
C
B
GxH
DxE
ES1313 88 x55 2 1 1 1 / / / /
ES1717 150 x 70 5 3 2 2 2 1 / /
ES2216 200 x 70 6 3 3 3 2 2 / /
ES2222 200 x 85 8 5 3 3 3 2 2 /
ES3322 285 x 90 12 7 6 5 4 3 3 /
ES3333 275 x 90 12 7 6 5 4 3 2 /
ES4433 370 x 110 20 14 12 12 6 5 3 /
ES5242 420 x 145 30 18 16 12 12 8 4 2
ES6348 500 x 140 36 24 18 16 12 10 6 4
	 88 x55	 2	 1	 1	 1	 /	 /	 /	 /
	 150 x 70	 5	 3	 2	 2	 2	 1	 /	 /
	 120 x 70	 4	 2	 2	 2	 1	 1	 /	 /
	 200 x 85	 8	 5	 3	 3	 3	 2	 2	 /
	 200 x 90	 8	 5	 4	 4	 3	 2	 2	 /
	 275 x 90	 12	 7	 6	 5	 4	 3	 2	 /
	 265 x 110	 14	 10	 8	 8	 4	 3	 2	 /
	 360 x 145	 28	 18	 14	 11	 10	 7	 4	 3
	 400 x 140	 30	 21	 15	 12	 10	 8	 4	 3
A
B
C
D
ES1313 10 x 1 5 x 1 4 x 1 4 x 1 3 x 1 2 x 1 1 x 1 / 112 - 70
ES1717 20 x 1 10 x 1 8 x 1 8 x 1 6 x 1 3 x 1 2 x 1 1 x 1 150 - 150
ES2216 30 x 1 18 x 1 14 x 1 10 x 1 8 x 1 3 x 1 2 x 1 1 x 1 200 - 200
ES2222 26 x 1 16 x 1 12 x 1 10 x 1 8 x 1 4 x 1 2 x 1 2 x 1 200 - 160
ES3322 46 x 1 26 x 1 22 x 1 18 x 1 14 x 1 10 x 1 6 x 1 2 x 1 294 - 154
ES3333 46 x 2 24 x 2 22 x 2 16 x 2 14 x 2 10 x 1 8 x 1 3 x 1 290 - 290
ES4433 70 x 2 40 x 2 32 x 2 26 x 2 20 x 2 14 x 2 10 x 1 4 x 1 400 - 290
ES5242 70 x 3 44 x 3 34 x 3 30 x 3 22 x 3 18 x 2 14 x 1 6 x 1 460 - 370
ES6348 120 x 3 76 x 3 60 x 3 50 x 3 34 x 3 30 x 2 24 x 1 12 x 1 685 - 340
A
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
H
[mm]
INT.PLATE
X - Y [mm]
WEIGHT
[Kg]
DETAIL
130 - Feam Catalogue 01
Waterproof Enclosures
ES Technical Features
ES Body Enclosures Drilling Layout
ES Indicative quantity of terminals and relevant section
ENCLOSURE
CODE
DRILLING AREA
A-B [mm]
QUANTITY ALLOWED ENTRIES FOR
SIZE (from 1 to size 8)
1 2 3 4 5 6 7 8
DRILLING AREA
C-D [mm]
QUANTITY ALLOWED ENTRIES FOR
SIZE (from 1 to size 8)
1 2 3 4 5 6 7 8
wall DRILLING AREA
Reference Details Reference Details
REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
CODE
ENCLOSURE
SECT. 2,5
[mm/sq]
SECT. 6,0
[mm/sq]
SECT. 10,0
[mm/sq]
SECT. 16,0
[mm/sq]
SECT. 35,0
[mm/sq]
SECT. 50,0
[mm/sq]
SECT. 70,0
[mm/sq]
SECT. 240,0
[mm/sq]
INT.PLATE X - Y
[mm]
PLATE X-Y

More Related Content

What's hot

High Voltage Gas Insulated Substation (GIS) Routine Tests According to IEEE C...
High Voltage Gas Insulated Substation (GIS) Routine Tests According to IEEE C...High Voltage Gas Insulated Substation (GIS) Routine Tests According to IEEE C...
High Voltage Gas Insulated Substation (GIS) Routine Tests According to IEEE C...Ali Sepehri
 
Power System Stability Issues
Power System Stability IssuesPower System Stability Issues
Power System Stability IssuesChandan Kumar
 
Siemens MV GIS Switchgear
Siemens MV GIS SwitchgearSiemens MV GIS Switchgear
Siemens MV GIS Switchgearmichaeljmack
 
Electric Actuator
Electric ActuatorElectric Actuator
Electric Actuatordiego5wh
 
Control valve positioners
Control valve positionersControl valve positioners
Control valve positionersSagar Jathan
 
Delta V Control System Overview
Delta V Control System OverviewDelta V Control System Overview
Delta V Control System OverviewSumeet Goel
 
Protection Relays Numbering (ANSI)
Protection Relays Numbering (ANSI)Protection Relays Numbering (ANSI)
Protection Relays Numbering (ANSI)AHMED MOHAMED HEGAB
 
Partial Discharge Test - Switchgear
Partial Discharge Test - Switchgear Partial Discharge Test - Switchgear
Partial Discharge Test - Switchgear RajuGupta88
 
Genrator Relay Protection & Logics
Genrator Relay Protection & LogicsGenrator Relay Protection & Logics
Genrator Relay Protection & LogicsMahadev Kovalli
 
Oscillography analysis
Oscillography analysisOscillography analysis
Oscillography analysismichaeljmack
 
Transmission Loss Calculation on 33 / 66 / 132 KV Lines for Solar Power Plant
Transmission Loss Calculation on 33 / 66 / 132 KV  Lines for Solar Power PlantTransmission Loss Calculation on 33 / 66 / 132 KV  Lines for Solar Power Plant
Transmission Loss Calculation on 33 / 66 / 132 KV Lines for Solar Power PlantGensol Engineering Limited
 
Charecterisctic of control valves
Charecterisctic of control valvesCharecterisctic of control valves
Charecterisctic of control valvesPrem Baboo
 
Power Transformer Protection
Power Transformer ProtectionPower Transformer Protection
Power Transformer ProtectionAng Sovann
 
substation protection basics.ppt
substation protection basics.pptsubstation protection basics.ppt
substation protection basics.pptSalim Palayi
 
Modeling and Testing of Induction Motors
Modeling and Testing of Induction MotorsModeling and Testing of Induction Motors
Modeling and Testing of Induction MotorsBirju Besra
 

What's hot (20)

Servo systems, servomotors
Servo systems, servomotorsServo systems, servomotors
Servo systems, servomotors
 
High Voltage Gas Insulated Substation (GIS) Routine Tests According to IEEE C...
High Voltage Gas Insulated Substation (GIS) Routine Tests According to IEEE C...High Voltage Gas Insulated Substation (GIS) Routine Tests According to IEEE C...
High Voltage Gas Insulated Substation (GIS) Routine Tests According to IEEE C...
 
Power System Stability Issues
Power System Stability IssuesPower System Stability Issues
Power System Stability Issues
 
Siemens MV GIS Switchgear
Siemens MV GIS SwitchgearSiemens MV GIS Switchgear
Siemens MV GIS Switchgear
 
Electric Actuator
Electric ActuatorElectric Actuator
Electric Actuator
 
Control valve positioners
Control valve positionersControl valve positioners
Control valve positioners
 
Delta V Control System Overview
Delta V Control System OverviewDelta V Control System Overview
Delta V Control System Overview
 
Protection Relays Numbering (ANSI)
Protection Relays Numbering (ANSI)Protection Relays Numbering (ANSI)
Protection Relays Numbering (ANSI)
 
Plc notes
Plc notesPlc notes
Plc notes
 
Partial Discharge Test - Switchgear
Partial Discharge Test - Switchgear Partial Discharge Test - Switchgear
Partial Discharge Test - Switchgear
 
Genrator Relay Protection & Logics
Genrator Relay Protection & LogicsGenrator Relay Protection & Logics
Genrator Relay Protection & Logics
 
Busbar Configuarations
Busbar ConfiguarationsBusbar Configuarations
Busbar Configuarations
 
Oscillography analysis
Oscillography analysisOscillography analysis
Oscillography analysis
 
Drives training
Drives trainingDrives training
Drives training
 
Transmission Loss Calculation on 33 / 66 / 132 KV Lines for Solar Power Plant
Transmission Loss Calculation on 33 / 66 / 132 KV  Lines for Solar Power PlantTransmission Loss Calculation on 33 / 66 / 132 KV  Lines for Solar Power Plant
Transmission Loss Calculation on 33 / 66 / 132 KV Lines for Solar Power Plant
 
Charecterisctic of control valves
Charecterisctic of control valvesCharecterisctic of control valves
Charecterisctic of control valves
 
Power Transformer Protection
Power Transformer ProtectionPower Transformer Protection
Power Transformer Protection
 
substation protection basics.ppt
substation protection basics.pptsubstation protection basics.ppt
substation protection basics.ppt
 
Distributed Control System
Distributed Control SystemDistributed Control System
Distributed Control System
 
Modeling and Testing of Induction Motors
Modeling and Testing of Induction MotorsModeling and Testing of Induction Motors
Modeling and Testing of Induction Motors
 

Similar to 02 feam enclosures_eng

02 custodie eng
02 custodie eng02 custodie eng
02 custodie engHai Pham
 
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...Thorne & Derrick International
 
05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-eng05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-engHai Pham
 
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting Thorne & Derrick International
 
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2Thorne & Derrick International
 
01 illuminazione eng
01 illuminazione eng01 illuminazione eng
01 illuminazione engHai Pham
 
MEDC Manual Call Points & Break Glass Units for Hazardous Areas
MEDC Manual Call Points & Break Glass Units for Hazardous AreasMEDC Manual Call Points & Break Glass Units for Hazardous Areas
MEDC Manual Call Points & Break Glass Units for Hazardous AreasThorne & Derrick International
 
05 multiple control stations
05 multiple control stations05 multiple control stations
05 multiple control stationsHai Pham
 
|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิล
|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิล|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิล
|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิลAKBAR TRADING
 
06 pinze di-terra-eng
06 pinze di-terra-eng06 pinze di-terra-eng
06 pinze di-terra-engHai Pham
 
01 feam lighting_eng
01 feam lighting_eng01 feam lighting_eng
01 feam lighting_engHai Pham
 
Dts ac6 04-2016_eng
Dts ac6 04-2016_engDts ac6 04-2016_eng
Dts ac6 04-2016_engSathish J
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Dien Ha The
 
Fuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fujiFuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fujiThuan Kieu
 
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.orgFuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.orgDien Ha The
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Thuan Kieu
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.orgFuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.orgDien Ha The
 

Similar to 02 feam enclosures_eng (20)

02 custodie eng
02 custodie eng02 custodie eng
02 custodie eng
 
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
FEAM Enclosures - Hazardous Area & Explosion Proof Enclosures (ATEX, IECEx, I...
 
05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-eng05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-eng
 
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
 
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2
 
01 illuminazione eng
01 illuminazione eng01 illuminazione eng
01 illuminazione eng
 
MEDC Manual Call Points & Break Glass Units for Hazardous Areas
MEDC Manual Call Points & Break Glass Units for Hazardous AreasMEDC Manual Call Points & Break Glass Units for Hazardous Areas
MEDC Manual Call Points & Break Glass Units for Hazardous Areas
 
05 multiple control stations
05 multiple control stations05 multiple control stations
05 multiple control stations
 
JAREL EXPORT
JAREL EXPORTJAREL EXPORT
JAREL EXPORT
 
|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิล
|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิล|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิล
|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิล
 
06 pinze di-terra-eng
06 pinze di-terra-eng06 pinze di-terra-eng
06 pinze di-terra-eng
 
Borusan Mannesmann
Borusan MannesmannBorusan Mannesmann
Borusan Mannesmann
 
01 feam lighting_eng
01 feam lighting_eng01 feam lighting_eng
01 feam lighting_eng
 
Dts ac6 04-2016_eng
Dts ac6 04-2016_engDts ac6 04-2016_eng
Dts ac6 04-2016_eng
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900
 
Fuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fujiFuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fuji
 
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.orgFuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.orgFuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
 
Craig & Derricott Switch Disconnectors Catalogue
Craig & Derricott Switch Disconnectors CatalogueCraig & Derricott Switch Disconnectors Catalogue
Craig & Derricott Switch Disconnectors Catalogue
 

More from Hai Pham

03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_engHai Pham
 
System accessories
System accessoriesSystem accessories
System accessoriesHai Pham
 
Cm compact medium
Cm   compact mediumCm   compact medium
Cm compact mediumHai Pham
 
New dk ps rack brochure (final)
New dk ps rack brochure (final)New dk ps rack brochure (final)
New dk ps rack brochure (final)Hai Pham
 
Catalogue 34
Catalogue 34Catalogue 34
Catalogue 34Hai Pham
 

More from Hai Pham (7)

03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng
 
Nb cat
Nb catNb cat
Nb cat
 
System accessories
System accessoriesSystem accessories
System accessories
 
Cm compact medium
Cm   compact mediumCm   compact medium
Cm compact medium
 
Ps smart
Ps smartPs smart
Ps smart
 
New dk ps rack brochure (final)
New dk ps rack brochure (final)New dk ps rack brochure (final)
New dk ps rack brochure (final)
 
Catalogue 34
Catalogue 34Catalogue 34
Catalogue 34
 

02 feam enclosures_eng

  • 1. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment SWITCHRACKS Feam Catalogue 01 - 95 Switchracks On Request Accessories: •Stainless steel pipes and fittings •Galvanized steel epoxy painted supporting rack •Stainless steel supporting rack •Internal anticondensate painting orange RAL-2004 •External colours different from standard Mechanical characteristics Boxes marine grade copper free aluminum - stainless steel Painting external epoxy powders grey RAL-9006 colour Screws external stainless steel Gaskets silicon rubber Pipes and fittings galvanized steel Supporting rack hot dip galvanized steel Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D CUSTOM DESIGNED SWITCHRACKS, PANEL BOARDS, MOTOR STARTERS Ex Enclosures SWITCHRACK ATEX 94/9/EC NEC - NEMA 4, 7, 9 EXECUTION/ INSTALLATION II 2 GD Ex d IIB+H2 / IIC Class I - Groups B, C and D / Class II - Groups E, F, and G / Class III PROTECTION - 4, 7 BCD, 9 EFG AMBIENT TEMPERATURE -60° + 130°C -20°C ÷ +40°C MECHANICAL DEGREE IP65 - IP66 IP66 CERTIFICATION AND COMPLIANCES - UL Standard 1203 - 4° Ed. (15 Sett. 2006) Explosion-Proof / Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations ANTISEISMIC TEST FOR PERFORMING zone UBC 3 e MSK > VIII < IX zone UBC 4 MSK > IX CERTIFICATE REF. CESI doc.: A9022645 RULES OF COMPLIANCE CEI EN 60068-2-57 Cat.1; CEI EN 60068-3-3
  • 2. YOUR PARTNER FOR SAFETY Since 1961 SWITCHRACKS 96 - Feam Catalogue 01 Ex Enclosures SWITCHRACKS, PANEL BOARDS - General Information INFORMATIONS: Test and inspections: All components and documents are tested and checked at the various working stages , according to FEAM’s “Quality Pans”. The above mentioned Plans call for all test and checks necessary to ensure an execution “on purpose”. Whenever a strict, documented quality control execution is required please advise FEAM Sales Department. When the switchrack is completed ,an effective working inspection is carried out, and an “inspection report” is written. Customer’s inspectors are allowed in FEAM’s workshop to survey working evolution and to witness final inspection. Standard Tests and Checks: • Visual and dimensional control • Working control • Equipment control Ordering: The following technical information are needed to work out a switchrack. A direct consult with FEAM Sales Department is however advisable, especially when problems of space arise. A) Area classification and mode of protection. B) Applicable standards C) Power and auxiliary wiring diagrams or full, detailed description of switchrack’s work D) Maximum overall dimensions. Possibility of double front execution E) Location of incoming and outgoing cable entries F) Threading, size and number of hubs G) Type of cable entries H) Painting cycle, type and color I) Switchrack’s location (indoor or outdoor) L) Request of protective canopy(if needed) N) “Vendor List” of components to be respected (if any) Responsibility: Once acknowledged the order, FEAM Technical Dept. issues electrical and mechanical manufacturing drawings. These drawings are sent to customer “for approval” and whichever change has to be advised as soon as possible. We take full responsibility for engineering, purchasing and assembling of components ,wiring and erection of the ensemble ready for installation. REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Description: “SWITCH-RACK” is a word usually adopted to indicate an ensemble of control units, signaling units, motor starters, switching units, and so on. Switch-racks are mechanically assembled on robust frame with various fixing solutions (ground, wall, etc.), electrically wired up on purpose. FEAM since over 40 years, designs and manufacturers switch-racks according to its own diagram or according to customer’s specifications, in full compliance with European CENELEC standards. • Grinding check • Insulation resistance measuring • Insulation test / Electrical running test • Mechanical running control • Hydrostatic test • Insulation test
  • 3. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment EJB EJB Feam Catalogue 01 - 97 Ex Enclosures ENCLOSURES On Request Accessories: •External epoxy painting with colour on request •Internal anticondensate painting orange RAL-2004 •O-Ring gaskets on cover •Glass windows on cover •Drain and breather valves Mechanical characteristics Body/cover marine grade copper free aluminium light alloy Screws stainless steel Internal mounting plate hot dip galvanized steel / aluminum Fixing fixing lugs AL UNI EN 1706:1999 - galvanized steel stirrups sp. 10mm (EJB71 AND EJB91 ONLY) Hinges On the long side - cast on enclosure body and cover Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D TERMINAL BOARD Modular terminal strip / power distribution bars ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d IIB+H2 T6 II 2 G Ex d [ia/ib] IIB+H2 T6 II 2 D Ex tD A21 T85°C II 2 G Ex d IIB+H2 T6 II 2 G Ex d [ia/ib] IIB+H2 T6 II 2 D Ex tD A21 T85°C 1 Ex d IIB+H2 T6 1 Ex d [ia/ib] IIB+H2 T6 A21 TA85°C 1 Ex d IIB+H2 T6 1 Ex d [ia/ib] IIB+H2 T6 A21 TA85°C AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C PROTECTION DEGREE IP66 IP66 IP66 IP66 CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 POWER UNITS Current and voltage transformers / power supplies / rectifiers ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d IIB+H2 T6…T3 II 2 D Ex tD A21 T85°C…150°C II 2 G Ex d IIB+H2 T6…T3 II 2 D Ex tD A21 T85°C…150°C 1 Ex d IIB+H2 T6…T3 A21 TA85°C…150°C 1 Ex d IIB+H2 T6…T3 A21 TA85°C…150°C AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C PROTECTION DEGREE IP66 IP66 IP66 IP66 CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 CONTROL AND SIGNALLING UNITS Lighting, power and receptacles distribution panelboards / switchracks / dol and dy motor starters / control and signalling panelboards ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d IIB+H2 T6…T3 II 2 (1) G Ex d [ia] IIB+H2 T6…T3 II 2 (2) G Ex d [ib] IIB+H2 T6…T3 II 2 D Ex tD A21 T85°C…150°C II 2 G Ex d IIB+H2 T6…T3 II 2 (1) G Ex d [ia] IIB+H2 T6…T3 II 2 (2) G Ex d [ib] IIB+H2 T6…T3 II 2 D Ex tD A21 T85°C…150°C 1 Ex d IIB+H2 T6…T3 1 Ex d [ia] IIB+H2 T6…T3 1 Ex d [ib] IIB+H2 T6…T3 A21 TA85°C…150°C 1 Ex d IIB+H2 T6…T3 1 Ex d [ia] IIB+H2 T6…T3 1 Ex d [ib] IIB+H2 T6…T3 A21 TA85°C…150°C AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C PROTECTION DEGREE IP66 IP66 IP66 IP66 CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 4. YOUR PARTNER FOR SAFETY Since 1961 EJB EJB-11 175 175 - 125 78 165 90 115 115 95 - 95 3,60 A EJB-21 285 245 267 169 160 276 122 217 175 180 - 140 10,50 A EJB-22 300 200 222 177 195 221 130 240 140 235 - 135 12,50 A EJB-30 415 315 340 168 280 306 120 340 245 325 - 225 18,50 A EJB-31 415 315 340 250 280 306 200 340 245 325 - 225 20,50 A EJB-51 568 365 388 257 360 376 203 495 295 460 - 260 36,50 A EJB-61 670 470 490 360 500 470 310 595 395 560 - 360 57,00 A EJB-63 670 470 490 235 500 470 184 595 395 560 - 360 47,00 A EJB-71 742 542 572 425 500 456 360 645 445 590 - 390 110,00 A EJB-91 960 660 700 460 700 526 370 830 530 758 - 448 202,00 A EJB-2 365 255 340 193 325 300 152 327 218 300 - 190 17,00 B EJB-3 468 310 395 210 432 355 168 440 282 400 - 240 23,00 B EJB-4 492 380 470 270 450 430 217 458 346 410 - 300 33,00 B EJB-6 610 415 510 327 560 455 260 564 184 525 - 325 65,00 B G HxL C B A D F E Via M. Pagano, 3 I-20090Trezzano s/N ITALY www.feam-ex.com II2 GD CUSTODIA tipo ENCLOSURE type V Hz A BKI 08 ATEX 019 Ta W Ex d IIB+H Ex tD A21 IP66T °C NON APRIRE SOTTOTENSIONE DO NOT OPENWHILE ENERGIZED Ad ogni apertura del coperchio ripristinare il grasso ai siliconi. accertarsi che le valvole di respirazione e drenaggio siano sempre chiuse Renew silicone grease every tyme cover is opened. and make sure that the drain and breather valves are always closed. VA 11.00.88 S.r.l. 2 T years/n 0722 G HxL B E A D C F B A 98 - Feam Catalogue 01 Ex Enclosures EJB Technical features Reference details CODE A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] H [mm] L [mm] INT. PLATE X - Y [mm] WEIGHT [Kg] DETAIL
  • 5. YOUR PARTNER FOR SAFETY Since 1961 EJB Via M. Pagano, 3 I-20090Trezzano s/N ITALY www.feam-ex.com II2 GD0722 CUSTODIA tipo ENCLOSURE type V Hz A BKI 08 ATEX 019 Ta W Ex d IIB+H Ex tD A21 IP66T °C NON APRIRE SOTTOTENSIONE DO NOT OPENWHILE ENERGIZED Ad ogni apertura del coperchio ripristinare il grasso ai siliconi. accertarsi che le valvole di respirazione e drenaggio siano sempre chiuse Renew silicone grease every tyme cover is opened. and make sure that the drain and breather valves are always closed. VA 11.00.88 S.r.l. 2 T years/n A B F1 X X X X X X X X 60 60 C F2 X X - X X X X X 75 75 C F3 - X X X X X X X 110 75 C F4 - X - X X X - - 150 75 C F5 - - - X X X - - 150 150 C F6 - - - X X X - - 300 75 C F7 - - - X X X - - 300 150 C F8 - - - - - X - - 300 300 C F9 - - - - - X - - 450 300 C EJB-11 12 x 1 8 x 1 6 x 1 4 x 1 2 x 1 - - - 95 - 95 EJB-21 30 x 1 20 x 1 14 x 1 12 x 1 8 x 1 6 x 1 2 x 1 1 x 1 180 - 140 EJB-22 44 x 1 30 x 1 20 x 1 18 x 1 12 x 1 10 x 1 4 x 1 2 x 1 235 - 135 EJB-30 52 x 2 32 x 2 24 x 2 20 x 2 14 x 2 12 x 1 8 x 1 4 x 1 325 - 225 EJB-31 52 x 2 32 x 2 24 x 2 20 x 2 14 x 2 12 x 1 8 x 1 4 x 1 325 - 225 EJB-51 80 x 2 46 x 2 36 x 2 30 x 2 22 x 2 18 x 2 16 x 1 6 x 1 460 - 260 EJB-61 92 x 3 58 x 3 46 x 3 38 x 3 28 x 3 26 x 2 22 x 2 12 x 1 560 - 360 EJB-63 92 x 3 58 x 3 46 x 3 38 x 3 28 x 3 26 x 2 22 x 2 12 x 1 560 - 360 EJB-71 110 x 3 70 x 3 56 x 3 46 x 3 34 x 3 28 x 2 24 x 2 12 x 1 590 - 390 EJB-91 140 x 3 90 x 3 70 x 3 60 x 3 44 x 3 36 x 3 32 x 2 14 x 2 758 - 448 EJB-2 54 x 1 34 x 1 26 x 1 22 x 1 16 x 1 12 x 1 6 x 1 2 x 1 300 - 190 EJB-3 70 x 2 46 x 2 36 x 2 30 x 2 22 x 2 18 x 1 10 x 1 4 x 1 400 - 240 EJB-4 70 X 2 40 x 2 32 x 2 26 x 2 20 x 2 14 x 2 10 x 1 4 x 1 410 - 300 EJB-6 80 x 3 50 x 3 36 x 3 28 x 3 18 x 3 16 x 2 12 x 2 6 x 1 525 - 325 C Feam Catalogue 01 - 99 Ex Enclosures EJB Glass Windows on Cover Reference details Reference details plate WINDOW CODE ENCLOSURE CODE DIMENSIONS DETAIL EJB-11 EJB-21 EJB-22 EJB-30/31 EJB-51 EJB-61/63 EJB-71 EJB-91 A [mm] B [mm] PLATE X-Y EJB Indicative quantity of terminals and relevant section CODE SECT. 2,5 [mm/sq] SECT. 6,0 [mm/sq] SECT. 10,0 [mm/sq] SECT. 16,0 [mm/sq] SECT. 35,0 [mm/sq] SECT. 50,0 [mm/sq] SECT. 70,0 [mm/sq] SECT. 240,0 [mm/sq] INT. PLATE X - Y [mm]
  • 6. YOUR PARTNER FOR SAFETY Since 1961 EJB EJB-11 120x120 6 EJB-21 200x155 12 EJB-22 240x120 15 EJB-30 305x205 30 EJB-31 305x205 30 EJB-51 465x265 54 EJB-61 575x370 56 EJB-63 575x370 56 EJB-71 590x390 48 EJB-91 800x500 54 EJB-2 290x180 24 EJB-3 380x220 40 EJB-4 390x280 47 EJB-6 500x310 55 1 GK 1/2” G 1/2” 1/2” NPT M20 2 GK 3/4” G 3/4” 3/4” NPT M25 3 GK 1” G 1” 1” NPT M32 4 GK 1-1/4” G 1-1/4” 1-1/4” NPT M40 5 GK 1-1/2” G 1-1/2” 1-1/2” NPT M50 6 GK 2” G 2” 2” NPT M63 7 GK 2-1/2” G 2-1/2” 2-1/2” NPT M75 8 GK 3” G 3” 3” NPT M85 E F A B D C EJB-11 125x60 4 2 2 1 1 - - - EJB-21 200x90 10 7 5 3 2 2 1 - EJB-22 215x130 15 11 8 6 6 3 2 1 EJB-30 320x65 13 7 5 5 4 3 - - EJB-31 320x150 28 18 14 11 8 6 3 2 EJB-51 460x155 44 27 24 20 12 10 6 3 EJB-61 550x250 72 50 36 32 21 21 14 8 EJB-63 550x130 36 29 18 16 14 7 5 4 EJB-71 600x270 78 55 50 36 32 21 18 10 EJB-91 745x290 112 84 65 55 40 28 23 14 EJB-1 175x115 12 6 6 5 3 2 1 1 EJB-2 310x105 17 12 10 9 5 4 3 2 EJB-3 425x115 30 17 14 12 9 5 4 3 EJB-C237 200x60 6 4 3 2 2 - - - 125x60 4 2 2 1 1 - - - 160x90 8 5 4 3 2 1 1 - 110x130 9 5 5 4 2 1 1 1 225x65 9 5 4 3 3 2 - - 225x150 20 12 9 8 6 5 2 1 255x155 24 15 12 11 6 6 3 2 350x250 48 30 24 20 12 12 8 6 350x130 24 17 12 10 8 4 3 3 400x270 48 35 35 24 20 15 12 6 440x290 70 42 35 35 24 18 13 8 175x115 12 6 6 5 3 2 1 1 200x105 11 8 6 5 3 2 2 1 270x115 18 11 8 8 6 3 2 2 130x60 4 2 2 2 1 - - - 100 - Feam Catalogue 01 Ex Enclosures EJB Body and Cover Enclosures Drilling Layout wall DRILLING AREA REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Cover DRILLING AREA Reference details Reference details ENCLOSURE CODE DRILLING AREA A-B [mm] QUANTITY ALLOWED ENTRIES FOR size (from 1 to size 8) 1 2 3 4 5 6 7 8 DRILLING AREA C-D [mm] QUANTITY ALLOWED ENTRIES FOR size (from 1 to size 8) 1 2 3 4 5 6 7 8 ENCLOSURE CODE DRILLING AREA E-F [mm] MAX OPERATORS PERMITTED EJB Threads comparation table size UNI 6125 ISO 228/1 ASA B2.1 ISO 965/I
  • 7. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment EJBinx EJB INX Feam Catalogue 01 - 101 Ex Enclosures ENCLOSURES On Request Accessories: •External epoxy painting (any colours) •Internal anticondensate painting orange RAL-2004 •O-Ring gaskets on cover •Glass windows on cover Mechanical characteristics Body & cover stainless steel AISI-316 L Screws stainless steel Internal mounting plate stainless steel / aluminum Fixing fixing lugs stainless steel AISI-316 L - stainless steel stirrups sp.10mm (EJB71 AND EJB91 ONLY) Hinges applied Opening handle insulating material fixed on cover by stainless steel screws Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D TERMINAL BOARD Modular terminal strip / power distribution bars ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d IIB+H2 T6 II 2 G Ex d [ia/ib] IIB+H2 T6 II 2 D Ex tD A21 T85°C II 2 G Ex d IIB+H2 T6 II 2 G Ex d [ia/ib] IIB+H2 T6 II 2 D Ex tD A21 T85°C 1 Ex d IIB+H2 T6 1 Ex d [ia/ib] IIB+H2 T6 A21 TA85°C 1 Ex d IIB+H2 T6 1 Ex d [ia/ib] IIB+H2 T6 A21 TA85°C AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C PROTECTION DEGREE IP66 IP66 IP66 IP66 CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0 EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 POWER UNITS Current and voltage transformers / power supplies / rectifier ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d IIB+H2 T6…T3 II 2 D Ex tD A21 T85°C…150°C II 2 G Ex d IIB+H2 T6…T3 II 2 D Ex tD A21 T85°C…150°C 1 Ex d IIB+H2 T6…T3 A21 TA85°C…150°C 1 Ex d IIB+H2 T6…T3 A21 TA85°C…150°C AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C PROTECTION DEGREE IP66 IP66 IP66 IP66 CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0 EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 CONTROL AND SIGNALLING UNITS Lighting, power and receptacles distribution panelboards / switchracks / dol and dy motor starters / control and signalling panelboards ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d IIB+H2 T6…T3 II 2 (1) G Ex d [ia] IIB+H2 T6…T3 II 2 (2) G Ex d [ib] IIB+H2 T6…T3 II 2 D Ex tD A21 T85°C…150°C II 2 G Ex d IIB+H2 T6…T3 II 2 (1) G Ex d [ia] IIB+H2 T6…T3 II 2 (2) G Ex d [ib] IIB+H2 T6…T3 II 2 D Ex tD A21 T85°C…150°C 1 Ex d IIB+H2 T6…T3 1 Ex d [ia] IIB+H2 T6…T3 1 Ex d [ib] IIB+H2 T6…T3 A21 TA85°C…150°C 1 Ex d IIB+H2 T6…T3 1 Ex d [ia] IIB+H2 T6…T3 1 Ex d [ib] IIB+H2 T6…T3 A21 TA85°C…150°C AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C PROTECTION DEGREE IP66 IP66 IP66 IP66 CERTIFICATE REF. BKI 08 ATEX 019 IECEx BKI 09.0005 POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0 EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 8. YOUR PARTNER FOR SAFETY Since 1961 EJBinx EJB-21 INX 285 245 260 194 160 230 122 215 175 180 - 140 32,00 A EJB-22 INX 300 200 215 218 195 188 177 230 130 235 - 135 38,00 A EJB-30 INX 415 315 330 158 294 290 117 335 235 325 - 225 53,00 A EJB-31 INX 415 315 330 223 294 290 180 335 235 325 - 225 62,00 A EJB-51 INX 565 365 400 233 360 335 190 480 280 460 - 260 110,00 A EJB-61 INX 670 470 485 344 500 437 290 590 390 560 - 360 152,00 A EJB63 INX 670 470 485 229 500 437 180 590 390 560 - 360 140,00 A EJB-71 INX 742 542 557 400 500 456 360 645 445 590 - 390 280,00 A EJB-91 INX 960 660 678 431 600 640 364 843 543 758 - 448 618,00 A EJB-21 INX 30 x 1 20 x 1 14 x 1 12 x 1 8 x 1 6 x 1 2 x 1 1 x 1 180 - 140 EJB-22 INX 44 x 1 30 x 1 20 x 1 18 x 1 12 x 1 10 x 1 4 x 1 2 x 1 235 - 135 EJB-30 INX 52 x 2 32 x 2 24 x 2 20 x 2 14 x 2 12 x 1 8 x 1 4 x 1 325 - 225 EJB-31 INX 52 x 2 32 x 2 24 x 2 20 x 2 14 x 2 12 x 1 8 x 1 4 x 1 325 - 225 EJB-51 INX 80 x 2 46 x 2 36 x 2 30 x 2 22 x 2 18 x 2 16 x 1 6 x 1 460 - 260 EJB-61 INX 92 x 3 58 x 3 46 x 3 38 x 3 28 x 3 26 x 2 22 x 2 12 x 1 560 - 360 EJB-63 INX 92 x 3 58 x 3 46 x 3 38 x 3 28 x 3 26 x 2 22 x 2 12 x 1 560 - 360 EJB-71 INX 110 x 3 70 x 3 56 x 3 46 x 3 34 x 3 28 x 2 24 x 2 12 x 1 590 - 390 EJB-91 INX 140 x 3 90 x 3 70 x 3 60 x 3 44 x 3 36 x 3 32 x 2 14 x 2 758 - 448 BKI 08 ATEX 019 Via M. Pagano, 3 I-20090Trezzano s/N ITALY www.feam-ex.com NON APRIRE SOTTOTENSIONE DO NOT OPENWHILE ENERGIZED Ad ogni apertura del coperchio ripristinare il grasso ai siliconi. accertarsi che le valvole di respirazione e drenaggio siano sempre chiuse Renew silicone grease every tyme cover is opened. and make sure that the drain and breather valves are always closed. 11.00.88 S.r.l. II2 GD0722 CUSTODIA tipo ENCLOSURE type V Hz A Ta W Ex d IIB+H Ex tD A21 IP66T °C VA 2 T years/n G HxL C B A D F E A 102 - Feam Catalogue 01 Ex Enclosures EJB INX Technical features Reference details EJB Indicative quantity of terminals and relevant section CODE A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] H [mm] L [mm] INT. PLATE X - Y [mm] WEIGHT [Kg] DETAIL CODE SECT. 2,5 [mm/sq] SECT. 6,0 [mm/sq] SECT. 10,0 [mm/sq] SECT. 16,0 [mm/sq] SECT. 35,0 [mm/sq] SECT. 50,0 [mm/sq] SECT. 70,0 [mm/sq] SECT. 240,0 [mm/sq] INT. PLATE X - Y [mm]
  • 9. YOUR PARTNER FOR SAFETY Since 1961 EJBinx Via M. Pagano, 3 I-20090Trezzano s/N ITALY www.feam-ex.com NON APRIRE SOTTOTENSIONE DO NOT OPENWHILE ENERGIZED Ad ogni apertura del coperchio ripristinare il grasso ai siliconi. accertarsi che le valvole di respirazione e drenaggio siano sempre chiuse Renew silicone grease every tyme cover is opened. and make sure that the drain and breather valves are always closed. 11.00.88 S.r.l. II2 GD0722 CUSTODIA tipo ENCLOSURE type V Hz A Ta W Ex d IIB+H Ex tD A21 IP66T °C VA 2 T years/n BKI 08 ATEX 019 A B A B D C F1 X X X X X X X 60 60 C F2 X - X X X X X 75 75 C F3 X X X X X X X 110 75 C F4 X - X X X - - 150 75 C F5 - - X X X - - 150 150 C F6 - - X X X - - 300 75 C F7 - - X X X - - 300 150 C F8 - - - - X - - 300 300 C F9 - - - - X - - 450 300 C EJB-21 INX 200x90 10 7 5 3 2 2 1 - EJB-22 INX 215x130 15 11 8 6 6 3 2 1 EJB-30 INX 320x65 13 7 5 5 4 3 - - EJB-31 INX 320x150 28 18 14 11 8 6 3 2 EJB-51 INX 460x155 44 27 24 20 12 10 6 3 EJB-61 INX 550x250 72 50 36 32 21 21 14 8 EJB-63 INX 550x130 36 29 18 16 14 7 5 4 EJB-71 INX 600x270 78 55 50 36 32 21 18 10 EJB-91 INX 745x290 112 84 65 55 40 28 23 14 160x90 8 5 4 3 2 1 1 - 110x130 9 5 5 4 2 1 1 1 225x65 9 5 4 3 3 2 - - 225x150 20 12 9 8 6 5 2 1 255x155 24 15 12 11 6 6 3 2 350x250 48 30 24 20 12 12 8 6 350x130 24 17 12 10 8 4 3 3 400x270 48 35 35 24 20 15 12 6 440x290 70 42 35 35 24 18 13 8 C Feam Catalogue 01 - 103 Ex Enclosures EJB INX Glass Windows on Cover Reference details Reference details plate PLATE X-Y EJB INX Body and Cover Enclosures Drilling Layout Reference details ENCLOSURE CODE DRILLING AREA A-B [mm] QUANTITY ALLOWED ENTRIES FOR size (from 1 to size 8) 1 2 3 4 5 6 7 8 DRILLING AREA C-D [mm] QUANTITY ALLOWED ENTRIES FOR size (from 1 to size 8) 1 2 3 4 5 6 7 8 wall DRILLING AREA WINDOW CODE ENCLOSURE CODE DIMENSIONS DETAILEJB-21 INX EJB-22 INX EJB-30/31 INX EJB-51 INX EJB-61/63 INX EJB-71 INX EJB-91 INX A [mm] B [mm]
  • 10. YOUR PARTNER FOR SAFETY Since 1961 EJBinx EJB-21 INX 200x155 12 EJB-22 INX 240x120 15 EJB-30 INX 305x205 30 EJB-31 INX 305x205 30 EJB-51 INX 465x265 54 EJB-61 INX 575x370 56 EJB-63 INX 575x370 56 EJB-71 INX 590x390 48 EJB-91 INX 800x500 54 E F 1 GK 1/2” G 1/2” 1/2” NPT M20 2 GK 3/4” G 3/4” 3/4” NPT M25 3 GK 1” G 1” 1” NPT M32 4 GK 1-1/4” G 1-1/4” 1-1/4” NPT M40 5 GK 1-1/2” G 1-1/2” 1-1/2” NPT M50 6 GK 2” G 2” 2” NPT M63 7 GK 2-1/2” G 2-1/2” 2-1/2” NPT M75 8 GK 3” G 3” 3” NPT M85 104 - Feam Catalogue 01 Ex Enclosures EJB INX Body and Cover Enclosures Drilling Layout Cover DRILLING AREA Reference details REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. ENCLOSURE CODE DRILLING AREA E-F [mm] MAX OPERATORS PERMITTED EJB INX Threads comparation table size UNI 6125 ISO 228/1 ASA B2.1 ISO 965/I
  • 11. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment EJBul EJB UL Feam Catalogue 01 - 105 Ex Enclosures ENCLOSURES On Request Accessories: • External epoxy painting (any colours) • Internal anticondensate painting orange RAL-2004 • O-Ring gaskets on cover • Glass windows on cover • Drain and breather valves • Stainless steel hinges Mechanical characteristics Body and cover marine grade copper free aluminium light alloy Screws stainless steel - internal / external Internal plate hot dip galvanized steel / aluminium Fixing galvanized steel stirrups th.10mm Gaskets O-RING silicon rubber on cover (option on request) Installation: hazardous areas - see below table Classification: see below table TERMINAL BOARD / POWER UNITS CONTROL AND SIGNALLING UNITS NEC - NEMA 4, 7, 9 INSTALLATION Class I - Groups B, C and D / Class II – Groups E, F, and G / Class III PROTECTION 4, 7 BCD, 9 EFG AMBIENT TEMPERATURE -20°C ÷ +40°C MECHANICAL DEGREE IP66 CERTIFICATION AND COMPLIANCES UL Standard 1203 - 4° Ed. (15 Sett. 2006) Explosion-Proof / Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations
  • 12. YOUR PARTNER FOR SAFETY Since 1961 EJBul EJB-21UL 320 280 182 180 250 123 220 180 180 - 140 13,50 A EJB-31UL 450 350 253 294 335 187 350 250 325 - 225 27,00 A EJB-51UL 600 400 240 360 385 195 490 290 460 - 260 52,50 A EJB-61UL 710 500 384 500 470 295 580 370 560 - 360 114,00 A EJB-63UL 710 500 200 500 470 165 580 370 560 - 360 92,00 A EJB-21UL 12,60 11,10 7,20 7,10 9,90 4,90 8,70 7,10 7.10 - 5.60 31,00 A EJB-31UL 17,80 13,80 10,00 11,60 13,20 7,40 13,80 9,90 12.80 - 8.90 62,00 A EJB-51UL 23,70 15,80 9,50 14,20 15,20 7,70 19,30 11,50 18.20 - 10.30 121,00 A EJB-61UL 28,00 19,70 15,20 19,70 18,60 11,70 22,90 14,60 22.10 - 14.20 262,00 A EJB-63UL 28,00 19,70 7,90 19,70 18,60 6,50 22,90 14,60 22.10 - 14.20 212,00 A G HxL B A D F E EJB-21 UL 190 80 7,50 3,20 150 80 6,00 3,20 EJB-31 UL 320 140 12,60 5,60 230 140 9,10 5,60 EJB-51 UL 450 120 17,80 4,80 250 120 9,90 4,80 EJB-61 UL 550 260 21,70 10,30 350 260 13,80 10,30 EJB-63 UL 550 150 21,70 6,00 350 150 13,80 6,00 A CODE A [mm] B [mm] D [mm] E [mm] F [mm] G [mm] H [mm] L [mm] INT. PLATE X-Y [mm] WEIGHT [Kg] DETAIL CODE A [inch.] B [inch.] D [inch.] E [inch.] F [inch.] G [inch.] H [inch.] L [inch.] INT. PLATE X - Y [inch.] WEIGHT [lbs] DETAIL 106 - Feam Catalogue 01 Ex Enclosures EJB UL Technical features EJB UL Body Enclosures Drilling Layout Reference details ENCLOSURE CODE AREA FOR ENTRY INSTALLATION (LONG WALL SIDES) AREA FOR ENTRY INSTALLATION (SHORT WALL SIDES) A [mm] B [mm] A [inch.] B [inch.] C [mm] D [mm] C [inch.] D [inch.]
  • 13. YOUR PARTNER FOR SAFETY Since 1961 EJBul CA B D 4” - - - - - - - - 139 - (5.47) 3” - - - - - - - 115 126 M90 (4.53) (4.96) 2 1/2” - - - - - - 101 108 120 M75 (3.98) (4.25) (4.72) 2” - - - - - 88 94 102 112 M63 (3.46) (3.70) (4.02) (4.41) 1 1/2” - - - - 75 82 88 95 106 M50 (2.95) (3.23) (3.46) (3.74) (4.17) 1 1/4” - - - 67 70 77 84 91 103 M40 (2.64) (2.76) (3.03) (3.31) (3.58) (4.06) 1” - - 58 63 66 73 80 86 99 M32 (2.28) (2.48) (2.60) (2.87) (3.15) (3.39) (3.90) 3/4” - 52 55 59 63 69 79 83 95 M25 (2.05) (2.17) (2.32) (2.48) (2.72) (2.99) (3.27) (3.74) 1/2” 46 49 52 57 60 67 73 80 93 M20 (1.81) (1.93) (2.05) (2.24) (2.36) (2.64) (2.87) (3.15) (3.66) NPT 1/2” 3/4” 1” 1 1/4” 1 1/2” 2” 2 1/2” 3” 4” Metric M20 M25 M32 M40 M50 M63 M75 M90 - E F EJB-21 UL 200 150 7,90 6,00 50 2,00 EJB-31 UL 300 200 11,90 7,90 50 2,00 EJB-51 UL 460 260 18,20 10,30 50 2,00 EJB-61 UL 570 370 22,50 14,60 50 2,00 EJB-63 UL 570 370 22,50 14,60 50 2,00 Feam Catalogue 01 - 107 Ex Enclosures EJB UL Body Enclosures Drilling Layout Reference details WALL DRILLING AREA MINIMUM DISTANCE BETWEEN WAAL ENTRIES (CENTER TO CENTER) 1st ROW [mm] - 2nd ROW [inch.] EJB UL Cover Enclosures Drilling Layout ENCLOSURE CODE AREA FOR OPERATORS INSTALLATION ENCLOSURE COVER MINUMUM DISTANCE BETWEEN OPENINGS (CENTER TO CENTER) E [mm] F [mm] E [inch.] F [inch.] [mm] [inch.] Cover DRILLING AREA
  • 14. YOUR PARTNER FOR SAFETY Since 1961 EJBul EJB-21 UL 30 x 1 20 x 1 14 x 1 12 x 1 8 x 1 6 x 1 2 x 1 1 x 1 180 - 140 7.10 - 5.60 EJB-31UL 52 x 2 32 x 2 24 x 2 20 x 2 14 x 2 12 x 1 8 x 1 4 x 1 325 - 225 12.80 - 8.90 EJB-51 UL 80 x 2 46 x 2 36 x 2 30 x 2 22 x 2 18 x 2 16 x 1 6 x 1 460 - 260 18.20 - 10.30 EJB-61 UL 92 x 3 58 x 3 46 x 3 38 x 3 28 x 3 26 x 2 22 x 2 12 x 1 560 - 360 22.10 - 14.20 EJB-63 UL 92 x 3 58 x 3 46 x 3 38 x 3 28 x 3 26 x 2 22 x 2 12 x 1 560 - 360 22.10 - 14.20 108 - Feam Catalogue 01 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. EJB UL Additional Technical features PRODUCT COVERED Explosion-proof enclosures for use in Hazardous Locations, Class I, Groups B, C, and D; Class II, Groups E, F, and G; Class III. These enclosures are Classified as to explosion and fire hazards only in according to Standard UL1203 4° ed. The explosion-proof enclosures are suitable for Class I, Group B Hazardous Locations only when provided with from M20 to M90, 1/2 in. to 3 in., supply connection openings. If other supply connection openings are provided, then the enclosures are suitable for Class I, Groups C & D Hazardous Locations only. The 1/2 in. NPSM operator openings are only suitable for enclosures marked for Class I, Groups B, C & D Hazardous Locations The enclosures covered by this Certification may have electrical components installed inside. The installation of electrical components shall not reduce the mechanical integrity of the enclosures. The enclosures may or may not be provided with hinges for service of the enclosures only. PROTECTION AGAINST CORROSION All ferrous-metal other than stainless steel shall be protected against corrosion, except at joint surfaces and conduit threads There shall be no materials applied to joint surfaces. GROUNDING Internal Ground Screw – Hexagon head screw M6 x 10 with a stainless steel flat and lock washer provided on the base of the enclosure body. External Ground – Terminal colored green, marked with the letter or word “G”, “GROUND”, or marked with a grounding symbol. SUPPLY CONNECTIONS NPT and Metric Supply Connections - The side walls of the enclosure are provided with conduit openings or none may be supplied, in which case field drilling and tapping instructions are provided with each enclosure. The entry is drilled and tapped completely through the enclosure wall, and the inside edge is smoothed and well-rounded such that the conductor insulation will not be damaged when installed. All unused openings are closed with plated steel, plated cast iron or aluminum close-up plugs which are threaded to match the opening. Closer-up Plugs have to be Listed for the same Class, Group and Division as marked on Enclosure nameplate. OPERATOR OPENINGS The cover of the enclosure may be provided with operator openings in the cover only and located only as given in drilling and tapping instructions provided with each Classified enclosure. All unused openings are closed with plated steel, plated cast iron or aluminum close-up plugs which are threaded to match the opening. Closer-up Plugs have to be Listed for the same Class, Group and Division as marked on Enclosure nameplate. EJB UL Indicative quantity of terminals and relevant section CODE SECT. 2,5 [mm/sq] SECT.6,0 [mm/sq] SECT. 10,0 [mm/sq] SECT. 16,0 [mm/sq] SECT. 35,0 [mm/sq] SECT. 50,0 [mm/sq] SECT. 70,0 [mm/sq] SECT. 240,0 [mm/sq] INT. PLATE X - Y [mm] [inch.] Ex Enclosures
  • 15. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment GUB GUB Feam Catalogue 01 - 109 Ex Enclosures ENCLOSURES On Request Accessories: • External epoxy painting with colour on request • Internal anticondensate painting orange RAL-2004 • O-Ring gaskets on cover • Glass windows on cover • Drain and breather valves Mechanical characteristics Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless sttel Internal plate hot dip galvanized steel / aluminium Fixing fixing lugs AL UNI 4514 casting on enclosure body Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D POWER UNIT / CONTROL AND SIGNALLING UNITS / TERMINAL BOARD ATEX 94/9/EC IEC Ex GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d IIC T3…T6 II 2(1) GD Ex d [ia/ib] IIC T6 II 2 D Ex tD A21 T85°C...T200°C II 2 D Ex tD [iaD/ibD] A21 T85°C II 2 G Ex d IIC T3…T6 II 2(1) GD Ex d [ia/ib] IIC T6 II 2 D Ex tD A21 T85°C...T200°C II 2 D Ex tD[iaD/ibD] A21 T85°C 1 Ex d IIC T6, T5,T4X 1 Ex d [ia/ib] IIC T6X DIP A21 TA (85°C,100°C-135°C) 1 Ex d IIC T6, T5,T4X 1 Ex d [ia/ib] IIC T6X DIP A21 TA (85°C,100°C-135°C) AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C PROTECTION DEGREE IP66 IP66 IP66 IP66 CERTIFICATE REF. BKI 08 ATEX 048 IECEx BKI 09.0004 POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1; EN 61241-11 EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 16. YOUR PARTNER FOR SAFETY Since 1961 GUB GUE1 135 135 108 93 151 115 100 45 110 110 - Ø90 2,00 A GUB0 168 168 140 123 190 140 154 80 140 140 - 110 - 110 3,50 A GUB1 198 198 150 132 200 200 176 90 170 170 - 150 - 150 5,00 A GUB02 235 280 173 150 260 240 210 100 207 252 - 200 - 150 8,00 A GUB03 280 305 225 198 308 207 275 125 248 273 - 220 - 200 10,50 A GUB23 270 310 180 150 315 275 244 102 243 280 - 180 - 180 10,50 A GUB4 420 420 284 230 460 380 400 150 390 390 - 280 - 280 30,00 A GUB5 600 600 334 310 630 550 580 210 550 550 - 490 - 490 77,00 A GUBW11 180 180 146 130 210 146 160 77 152 152 80 145 - 130 6,50 B GUBW02 235 280 167 150 260 240 210 100 207 252 120 200 - 150 11,00 B GUBW03 280 305 235 298 308 270 275 125 248 273 195 220 - 200 18,00 B F D O n O T N OPE e L WHI G R ENE D IZ E NON E IR A P R T O S O T NO N S I E T E GU MATR.-ANNO S. Nr.-YEAR www.feam-ex.comS.r.l. II 2G Ex d[ ] IICT II 2D Ex tD [ ]A21 IP66T °C BKI 08 ATEX 0480722 V Hz W A Ta NON APRIRE SOTTO TENSIONE /DO NOT OPEN WHILE ENERGIZED AD OGNI APERTURA DEL COPERCHIO RIPRISTINARE IL GRASSO AL SILICONE ACCERTARSI CHE LE VALVOLE DI RESPIRAZIONE E DRENAGGIO SIANO SEMPRE CHIUSE RENEW SILICONE GREASE EVERY TIME COVER IS OPENED AND MAKE SURE THAT THE DRAIN AND BREATHER VALVES ARE ALWAYS CLOSED 11.10.93 C AD H I-L ØG E B ØG E B ØM D C A F H I-L A B 110 - Feam Catalogue 01 Ex Enclosures GUB Technical features Reference details CODE A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] Ø G [mm] H [mm] I [mm] L [mm] Ø M [mm] INT.PLATE X - Y [mm] WEIGHT [Kg] DETAIL
  • 17. YOUR PARTNER FOR SAFETY Since 1961 GUB GUE1 102x50 2 1 1 1 / / / / GUB0 128x80 6 3 2 2 1 1 1 / GUB1 148x87 6 3 3 2 2 1 1 / GUB02 235x82 11 6 5 4 3 3 2 / GUB03 263x120 15 11 9 8 6 4 2 2 GUB23 270x97 11 10 8 6 4 3 2 / GUB4 350x140 23 18 14 11 10 7 4 3 GUB5 550x195 45 36 27 24 18 12 6 3 GUBW11 150x77 6 4 3 2 2 1 / / GUBW02 235x82 11 6 5 4 3 3 2 / GUBW03 263x120 15 11 9 8 6 4 2 2 102x50 2 1 1 1 / / / / 128x80 6 3 2 2 1 1 1 / 148x87 6 3 3 2 2 1 1 / 190x82 8 5 4 3 2 2 2 / 238x120 12 9 8 6 6 3 2 2 230x97 9 8 8 5 3 3 2 / 350x140 23 18 14 11 10 7 4 3 550x195 45 36 27 24 18 12 6 3 150x77 6 4 3 2 2 1 / / 190x82 8 5 4 3 2 2 2 / 238x120 12 9 8 6 6 3 2 2 A BB C D Feam Catalogue 01 - 111 Ex Enclosures GUB Body Enclosures Drilling Layout ENCLOSURE CODE DRILLING AREA A-B [mm] QUANTITY ALLOWED ENTRIES FOR size (from 1 to size 8) 1 2 3 4 5 6 7 8 DRILLING AREA C-D [mm] QUANTITY ALLOWED ENTRIES FOR size (from 1 to size 8) 1 2 3 4 5 6 7 8 Reference details Reference details wall DRILLING AREA plate PLATE X-Y PLATE X-Y
  • 18. YOUR PARTNER FOR SAFETY Since 1961 GUB GUE1 8x1 4x1 4x1 2x1 2x1 / / / Ø90 GUB0 12x1 6x1 6x1 4x1 4x1 2x1 1x1 / 110 - 110 GUB1 20x1 10x1 10x1 6x1 6x1 4x1 2x1 1x1 150 - 150 GUB02 32x1 18x1 16x1 12x1 8x1 6x1 4x1 2x1 200 - 150 GUB03 34x1 20x1 18x1 14x1 10x1 8x1 6x1 4x1 220 - 200 GUB23 26x1 16x1 14x1 12x1 8x1 6x1 4x1 1x1 180 - 180 GUB4 48x2 28x2 24x2 20x2 12x2 10x2 8x1 4x1 280 - 280 GUB5 64x3 20x3 36x3 30x3 11x3 16x3 16x1 6x2 490 - 490 GUBW11 16x1 10x1 8x1 8x1 6x1 4x1 2x1 / 140 - 130 GUBW2 32x1 18x1 16x1 12x1 8x1 6x1 4x1 2x1 200 - 150 GUBW3 34x1 20x1 18x1 14x1 10x1 8x1 6x1 4x1 220 - 200 1 GK 1/2” G 1/2” 1/2” NPT M20 2 GK 3/4” G 3/4” 3/4” NPT M25 3 GK 1” G 1” 1” NPT M32 4 GK 1-1/4” G 1-1/4” 1-1/4” NPT M40 5 GK 1-1/2” G 1-1/2” 1-1/2” NPT M50 6 GK 2” G 2” 2” NPT M63 7 GK 2-1/2” G 2-1/2” 2-1/2” NPT M75 8 GK 3” G 3” 3” NPT M85 112 - Feam Catalogue 01 Ex Enclosures Gub Sindicative quantity of terminals and relevant section REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. CODE ENCLOSURE SECT. 2,5 [mm/sq] SECT. 6,0 [mm/sq] SECT. 10,0 [mm/sq] SECT. 16,0 [mm/sq] SECT. 35,0 [mm/sq] SECT. 50,0 [mm/sq] SECT. 70,0 [mm/sq] SECT. 240,0 [mm/sq] INT.PLATE X - Y [mm] GUB Threads comparation table SIZE UNI 6125 ISO 228/1 ASA B2.1 ISO 965/I
  • 19. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment EMH9 EMH9Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D Feam Catalogue 01 - 113 Ex Enclosures On Request Accessories: • External epoxy painting with colour on request • Internal anticondensate painting Mechanical characteristics Body marine grade copper free aluminum Cover marine grade copper free aluminum Round window thransparent tempered glass Gasket NBR O-Ring sealing INSTRUMENT HOUSING ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d IIC T6 / T5 II 2 D Ex tD A21 T85°C / T100°C 1 Ex d IIC T6, T5 X DIP A21 TA 85°C...100°C 1 Ex d IIC T6, T5 X DIP A21 TA 85°C...100°C INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. INERIS 02 ATEX 0069X POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 INSTRUMENT HOUSING
  • 20. YOUR PARTNER FOR SAFETY Since 1961 EMH9 A B E ØH D C GK3/4” GK3/4” FG A 114 - Feam Catalogue 01 Ex Enclosures EMH9 Technical features Reference details REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. CODE A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] ØH [mm] WEIGHT [Kg] THREADED ENTRY DRAIN VALVE DETAIL EMH9.2 126 125 140 152 / 22 81 90 1,50 1 x 3/4” NO A EMH9.22 126 125 140 152 164 22 81 90 1,50 2 x 3/4” NO A EMH9.2V 126 125 140 152 / 22 81 90 1,50 1 x 3/4” YES A EMH9.22V 126 125 140 152 164 22 81 90 1,50 2 x 3/4” YES A
  • 21. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment GUA-EAHF GUA - EAHF EAHF GUA Feam Catalogue 01 - 115 Ex Enclosures JUNCTION AND PULLING BOXES On Request Accessories: • External epoxy painting with colour on request • Internal anticondensate painting orange RAL-2004 Mechanical characteristics Body marine grade copper free aluminum Cover marine grade copper free aluminum Screws external - stainless steel Gasket O-Ring sealing NBR Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D JUNCTION AND PULLING BOXES ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d IIC T6 / T3 II 2 D Ex tD A21 T85°C / T150°C 1 Ex d IIC T6 T85°C o 1 Ex d IIC U DIP A21 TA 85°C o DIP A21 1 Ex d IIC T6 T85°C o 1 Ex d IIC U DIP A21 TA 85°C o DIP A21 AMBIENT TEMPERTURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +52°C PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. INERIS 03 ATEX 0048 POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 22. YOUR PARTNER FOR SAFETY Since 1961 GUA-EAHF GUA…16 87 77 100 75 40 70 70 7 0,60 A GUA…17 113 100 130 79 50 95 82 9 0,90 A GUA…26 87 77 100 75 40 70 70 7 0,60 A GUA…27 113 100 130 79 50 95 82 9 0,90 A GUA…36 87 77 100 75 40 70 70 7 0,60 A GUA…37 113 100 130 79 50 95 82 9 0,90 A GUA…59 154 135 169 110 75 100 130 7,5 1,20 A GUA…69 154 135 169 110 75 100 130 7,5 1,20 A EAHF26 87 77 110 79 61 30 85 7 0,50 B GUAB16 2 x 1/2" GUAB17 2 x 1/2" GUAB26 2 x 3/4" GUAB27 2 x 3/4" GUAB36 2 x 1" GUAB37 2 x 1" GUAB59 2 x 1-1/2" GUAB69 2 x 2" GUAL16 2 x 1/2" GUAL17 2 x 1/2" GUAL26 2 x 3/4" GUAL27 2 x 3/4" GUAL36 2 x 1" GUAL37 2 x 1" GUAL59 2 x 1-1/2" GUAL69 2 x 2" GUAC16 2 x 1/2" GUAC17 2 x 1/2" GUAC26 2 x 3/4" GUAC27 2 x 3/4" GUAC36 2 x 1" GUAC37 2 x 1" GUAC59 2 x 1-1/2" GUAC69 2 x 2" GUAT16 3 x 1/2" GUAT17 3 x 1/2" GUAT26 3 x 3/4" GUAT27 3 x 3/4" GUAT36 3 x 1" GUAT37 3 x 1" GUAT59 3 x 1-1/2" GUAT69 3 x 2" EAHF26 3 x 3/4" GUAX16 4 x 1/2" GUAX17 4 x 1/2" GUAX26 4 x 3/4" GUAX27 4 x 3/4" GUAX36 4 x 1" GUAX37 4 x 1" GUAX59 4 x 1-1/2" GUAX69 4 x 2" GUAW16 4 x 1/2" GUAW17 4 x 1/2" GUAW26 4 x 3/4" GUAW27 4 x 3/4" GUAW36 4 x 1" GUAW37 4 x 1" GUAW59 4 x 1-1/2" GUAW69 4 x 2" GUAD16 3 x 1/2" GUAD17 3 x 1/2" GUAD26 3 x 3/4" GUAD27 3 x 3/4" GUAD36 3 x 1" GUAD37 3 x 1" GUAD59 3 x 1-1/2" GUAD69 3 x 2" FIGURAPOSIZIONE IMBOCCHI 1 2 3 4 5 FIGURAPOSIZIONE IMBOCCHI 1 2 3 4 5 6 7 FIGURAPOSIZIONE IMBOCCHI 1 2 3 4 5 FIGURAPOSIZIONE IMBOCCHI 1 2 3 4 5 6 7 FIGURAPOSIZIONE IMBOCCHI 1 2 3 4 5 FIGURAPOSIZIONE IMBOCCHI 1 2 3 4 5 6 7 FIGURAPOSIZIONE IMBOCCHI 1 2 3 4 5 95 ILEENER GIZED DONOT OPENWH C G E D ØA H F ØB C G E F H D ØB ØA A B 116 - Feam Catalogue 01 Ex Enclosures GUA - EAHF Technical features GUA - EAHF Hubs arrangement GUA - Reference details EAHF - Reference details CODE Ø A [mm] Ø B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] H [mm] WEIGHT [Kg] DETAIL REFERENCE DETAILS COMPLETE CODE HUBS REFERENCE DETAILS COMPLETE CODE HUBS Detail A Detail E Detail B Detail F Detail C Detail G Detail D
  • 23. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment HANDLES HANDLES OPERATORS (PILOT LIGHTS - PUSH BUTTONS - HANDLES) ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex d IIB+H2 II 2 D Ex tD A21 1 Ex d IIB+H2 / IIC T6…T3 1 Ex d IIB+H2 / IIC T6…T3 AMBIENT TEMPERATURE -60°C ÷ +130°C -60°C ÷ +130°C -60°C ÷ +130°C PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. - - - RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-11; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 Feam Catalogue 01 - 117 Ex Enclosures OPERATORS (PILOT LIGHTS -PUSH BUTTONS -HANDLES) Mechanical characteristics PILOT LIGHTS Body marine grade copper free aluminium light alloy Diffuser temperated glass / polycarbonate ILLUMINATED PUSH BUTTONS Body stainless steel Protection ring nickel plated brass Diffuser temperated glass Transmission stainless steel AISI 316L HANDLES Body marine grade copper free aluminium light alloy Transmission parts stainless steel AISI 316L PUSH BUTTONS Body stainless steel Protection ring nickel plated brass Button aluminium light alloy / polycarbonate Transmission stainless steel AISI 316L Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D
  • 24. YOUR PARTNER FOR SAFETY Since 1961 HANDLES 118 - Feam Catalogue 01 Ex Enclosures HANDLES Technical data CODE CONTACTS DIAGRAM PUSH BUTTON COLOUR THREAD SIZE BODY CODE CONTACTS DIAGRAM PUSH BUTTON COLOUR THREAD SIZE BODY BACK COVER INSTALLATION PADLOCKABLE HANDLE (ELEBERG BRAND CONTACTS) 63÷250AMP SIZE PADLOCKABLE HANDLE (ALL POSITIONS) CODE CONTACTS DIAGRAM SUPPLY LAMPHOLDER LAMP COLOUR THREAD SIZE BODY REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. SPRING RETURN PUSH BUTTON WITH LAMP FOR BACK COVER INSTALLATION PILOT LIGHT FOR BACK COVER INSTALLATION SPRING RETURN PUSH BUTTON - CONTACTS 10AMP SPRING RETURN MUSHROOM PUSH BUTTON - CONTACTS 10AMP RELEASE BY KEY STAY-PUT MUSHROOM PUSH BUTTON - CONTACTS 10AMP TURN TO RELEASE STAY-PUT MUSHROOM PUSH BUTTON - CONTACTS 10AMP EFP1#AZ1 1 NO LIGHT BLUE 1/2” EFP1#AZ2 1 NC LIGHT BLUE 1/2” EFP1#AZ3 1 NO + 1 NC LIGHT BLUE 1/2” EFP1#AZ4 2 NO LIGHT BLUE 1/2” EFP1#AZ5 2 NC LIGHT BLUE 1/2” EFP1#BI1 1 NO WHITE 1/2” EFP1#BI2 1 NC WHITE 1/2” EFP1#BI3 1 NO + 1 NC WHITE 1/2” EFP1#BI4 2 NO WHITE 1/2” EFP1#BI5 2 NC WHITE 1/2” EFP1#BL1 1 NO BLUE 1/2” EFP1#BL2 1 NC BLUE 1/2” EFP1#BL3 1 NO + 1 NC BLUE 1/2” EFP1#BL4 2 NO BLUE 1/2” EFP1#BL5 2 NC BLUE 1/2” EFP1#GI1 1 NO YELLOW 1/2” EFP1#GI2 1 NC YELLOW 1/2” EFP1#GI3 1 NO + 1 NC YELLOW 1/2” EFP1#GI4 2 NO YELLOW 1/2” EFP1#GI5 2 NC YELLOW 1/2” EFP1#NE1 1 NO BLACK 1/2” EFP1#NE2 1 NC BLACK 1/2” EFP1#NE3 1 NO + 1 NC BLACK 1/2” EFP1#NE4 2 NO BLACK 1/2” EFP1#NE5 2 NC BLACK 1/2” EFP1#RO1 1 NO RED 1/2” EFP1#RO2 1 NC RED 1/2” EFP1#RO3 1 NO + 1 NC RED 1/2” EFP1#RO4 2 NO RED 1/2” EFP1#RO5 2 NC RED 1/2” EFP1#VE1 1 NO GREEN 1/2” EFP1#VE2 1 NC GREEN 1/2” EFP1#VE3 1 NO + 1 NC GREEN 1/2” EFP1#VE4 2 NO GREEN 1/2” EFP1#VE5 2 NC GREEN 1/2” EFP1F#1 1 NO RED 1/2” EFP1F#2 1 NC RED 1/2” EFP1F#3 1 NO + 1 NC RED 1/2” EFP1F#4 2 NO RED 1/2” EFP1F#5 2 NC RED 1/2” EFP1FSC#NE1 1 NO BLACK 1/2” EFP1FSC#NE2 1 NC BLACK 1/2” EFP1FSC#NE3 1 NO + 1 NC BLACK 1/2” EFP1FSC#NE4 2 NO BLACK 1/2” EFP1FSC#NE5 2 NC BLACK 1/2” EFP1FSC#RO1 1 NO RED 1/2” EFP1FSC#RO2 1 NC RED 1/2” EFP1FSC#RO3 1 NO + 1 NC RED 1/2” EFP1FSC#RO4 2 NO RED 1/2” EFP1FSC#RO5 2 NC RED 1/2” EFP1FSR#GI1 1 NO YELLOW 1/2” EFP1FSR#GI2 1 NC YELLOW 1/2” EFP1FSR#GI3 1 NO + 1 NC YELLOW 1/2” EFP1FSR#GI4 2 NO YELLOW 1/2” EFP1FSR#GI5 2 NC YELLOW 1/2” EFP1FSR#NE1 1 NO BLACK 1/2” EFP1FSR#NE2 1 NC BLACK 1/2” EFP1FSR#NE3 1 NO + 1 NC BLACK 1/2” EFP1FSR#NE4 2 NO BLACK 1/2” EFP1FSR#NE5 2 NC BLACK 1/2” EFP1FSR#RO1 1 NO RED 1/2” EFP1FSR#RO2 1 NC RED 1/2” EFP1FSR#RO3 1 NO + 1 NC RED 1/2” EFP1FSR#RO4 2 NO RED 1/2” EFP1FSR#RO5 2 NC RED 1/2” EFI-RL - - - BLACK 1/2” EFI-RC (with key) - - - BLACK 1” EFISL - - - BLACK 3/8” EFLP3#BL1 1NO 12V ÷ 380V ac/dc Ba-9s BLUE M32 EFLP3#BL3 1NO + 1NC 12V ÷ 380V ac/dc Ba-9s BLUE M32 EFLP3#GI2 1NC 12V ÷ 380V ac/dc Ba-9s YELLOW M32 EFLP3#GI3 1NO + 1NC 12V ÷ 380V ac/dc Ba-9s YELLOW M32 EFLP3#RO1 1NO 12V ÷ 380V ac/dc Ba-9s RED M32 EFLP3#RO2 1NC 12V ÷ 380V ac/dc Ba-9s RED M32 EFLP3#RO3 1NO + 1NC 12V ÷ 380V ac/dc Ba-9s RED M32 EFLP3#VE1 1NO 12V ÷ 380V ac/dc Ba-9s GREEN M32 EFLP3#VE3 1NO + 1NC 12V ÷ 380V ac/dc Ba-9s GREEN M32 EFL1#AZ - 12V ÷ 380V ac/dc Ba-9s LIGHT BLUE 1/2” EFL1#BI - 12V ÷ 380V ac/dc Ba-9s WHITE 1/2” EFL1#BL - 12V ÷ 380V ac/dc Ba-9s BLUE 1/2” EFL1#GI - 12V ÷ 380V ac/dc Ba-9s YELLOW 1/2” EFL1#RO - 12V ÷ 380V ac/dc Ba-9s RED 1/2” EFL1#VE - 12V ÷ 380V ac/dc Ba-9s GREEN 1/2”
  • 25. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment ESA ESA JUNCTION BOX ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex e II T5 II 2 G Ex e [ia] IIB/IIC T5 II 2 D Ex tD A21 T100°C 2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X, 2Ex e [ia] IIB/IIC T4, T5 X DIP A21 TA 100°C 2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X, 2Ex e [ia] IIB/IIC T4, T5 X DIP A21 TA 100°C AMBIENT TEMPERATURE -50°C ÷ +175°C -50°C ÷ +175°C -50°C ÷ +175°C PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. INERIS 02 ATEX 0067X POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-7; EN 60079-11; 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 On Request Accessories: • External epoxy painting with colour on request • Internal anticondensate painting orange RAL-2004 • Drain and breather valves Mechanical characteristics Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless steel AISI 316L Internal plate hot dip galvanized steel Gasket silicon rubber Feam Catalogue 01 - 119 Ex Enclosures JUNCTION BOXES Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D
  • 26. YOUR PARTNER FOR SAFETY Since 1961 ESA ESA1313 130 130 85 115 115 71 114 114 112 - 70 1,20 A ESA1717 170 170 95 155 155 81 154 154 150 - 150 1,50 A ESA2216 220 160 95 205 145 81 204 144 200 - 100 3,80 A ESA2222 220 220 110 205 205 97 204 204 200 - 160 4,40 A ESA3322 330 220 120 312 202 103 316 206 294 - 154 6,40 A ESA3333 330 330 130 312 312 114 316 316 290 - 290 8,80 A ESA4433 440 330 150 420 310 155 426 316 400 - 290 11,40 A ESA5242 520 420 180 496 396 165 506 406 460 - 370 20,20 A ESA6348 630 480 180 610 460 165 598 466 550 - 400 21,30 A ESA1313 88 x55 2 1 1 1 / / / / ESA1717 150 x 70 5 3 2 2 2 1 / / ESA2216 200 x 70 6 3 3 3 2 2 / / ESA2222 200 x 85 8 5 3 3 3 2 2 / ESA3322 285 x 90 12 7 6 5 4 3 3 / ESA3333 275 x 90 12 7 6 5 4 3 2 / ESA4433 370 x 110 20 14 12 12 6 5 3 / ESA5242 420 x 145 30 18 16 12 12 8 4 2 ESA6348 500 x 140 36 24 18 16 12 10 6 4 88 x55 2 1 1 1 / / / / 150 x 70 5 3 2 2 2 1 / / 120 x 70 4 2 2 2 1 1 / / 200 x 85 8 5 3 3 3 2 2 / 200 x 90 8 5 4 4 3 2 2 / 275 x 90 12 7 6 5 4 3 2 / 265 x 110 14 10 8 8 4 3 2 / 360 x 145 28 18 14 11 10 7 4 3 400 x 140 30 21 15 12 10 8 4 3 A F C B GxH DxE A B C D ESA1313 10 x 1 5 x 1 4 x 1 4 x 1 3 x 1 2 x 1 1 x 1 / 112 - 70 ESA1717 20 x 1 10 x 1 8 x 1 8 x 1 6 x 1 3 x 1 2 x 1 1 x 1 150 - 150 ESA2216 30 x 1 18 x 1 14 x 1 10 x 1 8 x 1 3 x 1 2 x 1 1 x 1 200 - 200 ESA2222 26 x 1 16 x 1 12 x 1 10 x 1 8 x 1 4 x 1 2 x 1 2 x 1 200 - 160 ESA3322 46 x 1 26 x 1 22 x 1 18 x 1 14 x 1 10 x 1 6 x 1 2 x 1 294 - 154 ESA3333 46 x 2 24 x 2 22 x 2 16 x 2 14 x 2 10 x 1 8 x 1 3 x 1 290 - 290 ESA4433 70 x 2 40 x 2 32 x 2 26 x 2 20 x 2 14 x 2 10 x 1 4 x 1 400 - 290 ESA5242 70 x 3 44 x 3 34 x 3 30 x 3 22 x 3 18 x 2 14 x 1 6 x 1 460 - 370 ESA6348 90 x 3 56 x 3 44 x 3 40 x 3 28 x 3 24 x 2 20 x 1 10 x 1 550 - 400 A 120 - Feam Catalogue 01 Ex Enclosures ESA Technical features CODE A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] H [mm] INT. PLATE X - Y [mm] WEIGHT [Kg] DETAIL Reference details Reference details wall DRILLING AREA ESA Body Enclosures Drilling Layout ESA Indicative quantity of terminals and relevant section ENCLOSURE CODE DRILLING AREA A-B [mm] QUANTITY ALLOWED ENTRIES FOR SIZE (from 1 to size 8) 1 2 3 4 5 6 7 8 DRILLING AREA A-B [mm] QUANTITY ALLOWED ENTRIES FOR SIZE (from 1 to size 8) 1 2 3 4 5 6 7 8 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. CODE ENCLOSURE SECT. 2,5 [mm/sq] SECT. 6,0 [mm/sq] SECT. 10,0 [mm/sq] SEZ. 16,0 [mm/sq] SEZ. 35,0 [mm/sq] SECT. 50,0 [mm/sq] SECT. 70,0 [mm/sq] SECT. 240,0 [mm/sq] INT.PLATE X - Y [mm] plate X-Y
  • 27. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment ESX ESX Feam Catalogue 01 - 121 Ex Enclosures JUNCTION BOXES On Request Accessories: • External epoxy painting with colour on request • Internal anticondensate painting orange RAL-2004 • Drain and breather valves • Removable flanges on side walls (see identification table) Mechanical characteristics Body stainless steel AISI-316L - th. 1,5mm Cover stainless steel AISI-316L - th. 1,5mm Screws stainless steel AISI 316L Internal plate stainless steel AISI-316L - th. 1,5mm Gasket silicon rubber Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D JUNCTION BOX ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex e II T5 II 2 G Ex e [ia] IIB/IIC T5 II 2 D Ex tD A21 T100°C 2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X, 2Ex e [ia] IIB/IIC T4, T5 X DIP A21 TA 100°C 2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X, 2Ex e [ia] IIB/IIC T4, T5 X DIP A21 TA 100°C AMBIENT TEMPERATURE -50°C ÷ +175°C -50°C ÷ +175°C -50°C ÷ +175°C PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. INERIS 02 ATEX 0067X POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-7; EN 60079-11; 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 28. YOUR PARTNER FOR SAFETY Since 1961 ESX A E C G G1 HxI B D D1 F ESX-1313 130 130 205 - 88 180 53 - 53 127 127 80-80 1,00 A ESX-1717 170 170 245 - 88 220 90 - 53 167 167 128-128 2,00 A ESX-2212 220 120 295 - 88 270 50 - 53 217 117 178-78 2,50 A ESX-2216(1) 220 165 295 148 88 270 85 113 53 217 162 178-118 3,00 A ESX-2222(1) 220 220 295 148 88 270 140 113 53 217 217 170-170 4,00 A ESX-3322(1) 330 220 405 148 108 380 140 113 73 327 217 280-170 5,00 A ESX-3333(1) 330 330 405 148 108 380 250 113 73 327 327 280-280 6,80 A ESX-4422 440 220 515 148 - 490 140 113 - 437 217 398-178 7,00 A ESX-4433 440 330 515 148 - 490 250 113 - 437 327 390-290 8,50 A ESX-4936 490 360 560 148 - 534 280 113 - 487 357 440-315 9,50 A ESX-5242(1) 520 420 595 242 148 570 340 206 113 517 417 470-370 12,00 A ESX-6348 630 480 705 - 148 680 400 113 - 627 477 580-430 16,00 A ESX-7440(1) 745 400 820 227 148 795 320 191 113 742 397 695-350 18,00 A A 122 - Feam Catalogue 01 ESX Flanges (gland plates) identification table Standard availability in stock for enclosures without flanges Please refer to below diagram to define quntity and position of side walls flanges FC = flange on short side enclosure FL = Flange On Long Side Enclosure Number 1 or 2 placed before sentence FC or FL define flange quantities. ATTENTION: on each enclosure side wall is allowed one single flange only Example: ESX-3322A-1FC-2FL= Enclosure Dim. 330x220x148mm with 1 flange only on 1 short side + 2 flanges one on each long side ESX-5242A-2FC-2FL= enclosure Dim. 520x420x242mm with 2 flanges one on each short side + 2 flanges one on each long side Ex Enclosures ESX Technical Features Reference Details (1) ENCLOSURE DEEP: A = HIGH (see column D) - B = LOW (see column D1) SAMPLE: ESX-2222A = ENCLOSURE DIM. 220x220x148 mm / ESX-2216B = ENCLOSURE DIM. 220x165x88 mm CODE A [mm] B [mm] C [mm] D [mm] D1 [mm] E [mm] F [mm] G [mm] *G1 [mm] H [mm] I [mm] INT.PLATE X-Y [mm] WEIGHT [Kg] DETAIL
  • 29. YOUR PARTNER FOR SAFETY Since 1961 ESX NOTE: Per tenere conto dell’evoluzione della normativa nazionale ed internazionale e della tecnologia, le caratteristiche riportate in questa scheda tecnica possono ritenersi impegnative solo dopo nostra conferma. ESX-2216A 180 - 85 8 5 4 3 2 2 1 / ESX-2222A 180 - 85 8 5 4 3 2 2 1 / ESX-3322A 290 - 85 12 8 7 4 4 3 3 / ESX-3333A 290 - 85 12 8 7 4 4 3 3 / ESX-4422 400 - 85 16 11 9 7 6 5 4 / ESX-4433 400 - 85 16 11 9 7 6 5 4 / ESX-4936 450 - 85 18 13 11 8 6 5 4 / ESX-5242B 480 - 85 20 14 11 8 7 6 4 / ESX-5242A 480 - 178 40 28 22 16 14 12 8 4 ESX-6348 590 - 85 24 17 14 10 9 7 5 / ESX-7440B 705 - 85 30 21 17 13 10 8 6 / ESX-7440A 705 - 163 53 38 34 26 20 14 9 6 125 - 85 6 3 2 2 1 1 1 / 180 - 85 8 5 4 3 2 2 1 / 180 - 85 8 5 4 3 2 2 1 / 290 - 85 12 8 7 4 4 3 3 / 290 - 85 12 8 7 4 4 3 3 / 290 - 85 12 8 7 4 4 3 3 / 320 - 85 14 9 7 5 4 3 3 / 380 - 85 16 11 9 7 5 4 3 / 380 - 178 32 22 18 14 10 8 6 3 440 - 85 18 13 10 8 6 5 4 / 360 - 85 14 10 8 6 5 4 3 / 360 163 25 18 16 12 10 8 4 3 ESX-2216 214 159 / 119 ESX-2222 214 214 / 119 ESX-3322 324 214 / 119 ESX-3333 324 324 / 119 ESX-4422 434 214 / 119 ESX-4433 434 324 / 119 ESX-4936 484 359 / 119 ESX-5242(1) 514 414 212,5 119 ESX-6348 624 474 / 119 ESX-7440(1) 739 394 197,5 119 TIPO CUSTODIA SEZ. 2,5 [mm/sq] SEZ. 6,0 [mm/sq] SEZ. 10,0 [mm/sq] SEZ. 16,0 [mm/sq] SEZ. 35,0 [mm/sq] SEZ. 50,0 [mm/sq] SEZ. 70,0 [mm/sq] SEZ. 240,0 [mm/sq] ВНУТР. ПЛАСТИНА ESX-1313 3 x 1 3 x 1 2 x 1 2 x 1 2 x 1 1 x 1 1 x 1 / 80 - 80 ESX-1717 20 x 1 10 x 1 10 x 1 6 x 1 6 x 1 4 x 1 2 x 1 1 x 1 128 - 128 ESX-2212 28 x 1 16 x 1 12 x 1 10 x 1 8 x 1 6 x 1 4 x 1 / 178 - 78 ESX-2216(1) 30 x1 18 x 1 14 x 1 10 x 1 8 x 1 3 x 1 2 x 1 1 x 1 178 - 118 ESX-2222(1) 20 x 1 14 x 1 10 x 1 8 x 1 6 x 1 6 x 1 4 x 1 2 x 1 170 - 170 ESX-3322(1) 46 x 1 26 x 1 22 x 1 18 x 1 14 x 1 10 x 1 6 x 1 2 x 1 280 - 170 ESX-3333(1) 48 x 2 28 x 2 24 x 2 20 x 2 12 x 2 10 x 2 8 x 1 4 x 1 280 - 280 ESX-4422 70 x 1 44 x 1 34 x 1 30 x 1 22 x 1 18 x 1 14 x 1 6 x 1 398 - 178 ESX-4433 60 x 2 40 x 2 32 x 2 26 x 2 20 x 2 14 x 2 10 x 1 4 x 1 390 - 290 ESX-4936 70 x 2 44 x 2 36 x 2 30 x 2 22 x 2 18 x 2 14 x 1 8 x 1 440 - 315 ESX-5242(1) 70 x 3 44 x 3 34 x 13 30 x 3 22 x 3 18 x 2 14 x 1 6 x 1 470 - 370 ESX-6348 100 x 3 60 x 3 50 x 3 40 x 3 30 x 3 26 x 3 20 x 2 10 x 1 580 - 430 ESX-7440(1) 120 x 3 76 x 3 60 x 3 50 x 3 34 x 3 30 x 2 24 x 1 12 x 1 695 - 350 E G G1 F G G1 A C B D ESX-1313 3 x 1 3 x 1 2 x 1 2 x 1 2 x 1 1 x 1 1 x 1 / 80 - 80 ESX-1717 20 x 1 10 x 1 10 x 1 6 x 1 6 x 1 4 x 1 2 x 1 1 x 1 128 - 128 ESX-2212 28 x 1 16 x 1 12 x 1 10 x 1 8 x 1 6 x 1 4 x 1 / 178 - 78 ESX-2216(1) 30 x1 18 x 1 14 x 1 10 x 1 8 x 1 3 x 1 2 x 1 1 x 1 178 - 118 ESX-2222(1) 20 x 1 14 x 1 10 x 1 8 x 1 6 x 1 6 x 1 4 x 1 2 x 1 170 - 170 ESX-3322(1) 46 x 1 26 x 1 22 x 1 18 x 1 14 x 1 10 x 1 6 x 1 2 x 1 280 - 170 ESX-3333(1) 48 x 2 28 x 2 24 x 2 20 x 2 12 x 2 10 x 2 8 x 1 4 x 1 280 - 280 ESX-4422 70 x 1 44 x 1 34 x 1 30 x 1 22 x 1 18 x 1 14 x 1 6 x 1 398 - 178 ESX-4433 60 x 2 40 x 2 32 x 2 26 x 2 20 x 2 14 x 2 10 x 1 4 x 1 390 - 290 ESX-4936 70 x 2 44 x 2 36 x 2 30 x 2 22 x 2 18 x 2 14 x 1 8 x 1 440 - 315 ESX-5242(1) 70 x 3 44 x 3 34 x 13 30 x 3 22 x 3 18 x 2 14 x 1 6 x 1 470 - 370 ESX-6348 100 x 3 60 x 3 50 x 3 40 x 3 30 x 3 26 x 3 20 x 2 10 x 1 580 - 430 ESX-7440(1) 120 x 3 76 x 3 60 x 3 50 x 3 34 x 3 30 x 2 24 x 1 12 x 1 695 - 350 Feam Catalogue 01 - 123 Ex Enclosures ESX Removable flanges drilling layout ESX Removable flanges dimensions ESX Indicative quantity of terminals and relevant section Reference DetailsCODE E [mm] F [mm] G [mm] G1 [mm] (1) ENCLOSURE DEEP: A = HIGH (see column C) - B = LOW (see column C1) / SAMPLE: ESX-5242A = ENCLOSURE DIM. 520x420x242 mm (1) ENCLOSURE DEEP: A = HIGH - B = LOW (see Technical Feature table) flangeS flanges DRILLING AREA CODE ENCLOSURE SECT. 2,5 [mm/sq] SECT. 6,0 [mm/sq] SECT. 10,0 [mm/sq] SECT. 16,0 [mm/sq] SECT. 35,0 [mm/sq] SECT. 50,0 [mm/sq] SECT. 70,0 [mm/sq] SECT. 240,0 [mm/sq] INT.PLATE X - Y [mm] ENCLOSURE CODE DRILLING AREA A-B [mm] QUANTITY ALLOWED ENTRIES FOR SIZE (from 1 to size 8) 1 2 3 4 5 6 7 8 DRILLING AREA C-D [mm] QUANTITY ALLOWED ENTRIES FOR SIZE (from 1 to size 8) 1 2 3 4 5 6 7 8
  • 30. YOUR PARTNER FOR SAFETY Since 1961 ESX ESX-1313 117 - 44 2 2 / / / / / / ESX-1717 160 - 44 3 3 / / / / / / ESX-2212 210 - 44 4 4 / / / / / / ESX-2216B 210 - 44 4 4 / / / / / / ESX-2216A 210 - 100 8 8 6 5 3 2 2 1 ESX-2222B 210 - 44 4 4 / / / / / / ESX-2222A 210 - 100 8 8 6 5 3 2 2 1 ESX-3322B 320 - 64 9 6 5 5 4 / / / ESX-3322A 320 - 100 12 12 10 8 4 4 3 2 ESX-3333B 320 - 64 9 6 5 5 4 / / / ESX-3333A 320 - 100 12 12 10 8 4 4 3 2 ESX-4422 430 - 100 16 16 14 11 7 5 4 3 ESX-4433 430 - 100 16 16 14 11 7 5 4 3 ESX-4936 480 - 100 20 18 15 12 8 6 4 4 ESX-5242B 510 - 100 22 18 16 13 8 6 5 4 ESX-5242A 510 - 195 44 27 24 21 16 14 10 5 ESX-6348 620 - 100 29 22 20 16 10 7 6 5 ESX-7440B 735 - 100 33 26 24 18 12 9 7 5 ESX-7440A 735 - 180 55 43 38 33 20 18 14 7 A B C D 117 - 44 2 2 / / / / / / 160 - 44 3 3 / / / / / / 110 - 44 2 2 / / / / / / 155 - 44 3 3 / / / / / / 155 - 100 6 6 4 3 2 2 1 1 210 - 44 4 4 / / / / / / 210 - 100 8 8 6 5 3 2 2 1 210 - 64 6 4 3 3 2 / / / 210 - 100 8 8 6 5 3 2 2 1 320 - 64 9 6 5 5 4 / / / 320 - 100 12 12 10 8 4 4 3 2 210 - 100 8 8 6 5 3 2 2 1 320 - 100 12 12 10 8 4 4 3 2 350 - 100 14 14 10 8 5 4 3 3 410 - 100 18 14 13 10 7 5 4 3 410 - 195 36 21 18 15 12 11 8 4 470 - 100 21 16 15 12 7 5 4 3 390 - 100 18 14 12 9 6 4 3 3 390 - 180 30 23 20 15 9 8 6 3 1 GK 1/2” G 1/2” 1/2” NPT M20 2 GK 3/4” G 3/4” 3/4” NPT M25 3 GK 1” G 1” 1” NPT M32 4 GK 1-1/4” G 1-1/4” 1-1/4” NPT M40 5 GK 1-1/2” G 1-1/2” 1-1/2” NPT M50 6 GK 2” G 2” 2” NPT M63 7 GK 2-1/2” G 2-1/2” 2-1/2” NPT M75 8 GK 3” G 3” 3” NPT M85 124 - Feam Catalogue 01 Ex Enclosures ESX Body Enclosures Drilling Layout ENCLOSURE CODE DRILLING AREA A-B [mm] QUANTITY ALLOWED ENTRIES FOR SIZE (from 1 to size 8) 1 2 3 4 5 6 7 8 Reference Details Reference Details body DRILLING AREA plate DRILLING AREA C-D [mm] QUANTITY ALLOWED ENTRIES FOR SIZE (from 1 to size 8) 1 2 3 4 5 6 7 8 REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. SIZE UNI 6125 ISO 228/1 ASA B2.1 ISO 965/I ESX Threads comparation table PLATE X-Y
  • 31. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment GWR GWR Feam Catalogue 01 - 125 Ex Enclosures GLASS FIBRE REINFORCED POLYESTER RESIN JUNCTION BOXES On Request Accessories: • Drain and breather valves Mechanical characteristics Body glass fibre reinforced polyester resin Cover glass fibre reinforced polyester resin Screws external - stainless steel Internal plate aluminium Gasket hot dip galvanized steel Strenght 4 Joule impact resistance Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D JUNCTION BOX ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex e II T6 II 2 D Ex tD A21 T85°C 2Ex e II T6 DIP A21 TA 85°C 2Ex e II T6 DIP A21 TA 85°C INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. LOM 02 ATEX 2024 POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 32. YOUR PARTNER FOR SAFETY Since 1961 GWR NONAPRIRESOTTOTENSIONE-DONOTOPENWHILEENERGIZED B A C GxH D C A B D F E GWR11 64 x 52 1 1 1 1 - - - - GWR14 90 X 52 2 1 1 1 - - - - GWR21 108 - 85 4 2 2 2 1 1 1 - GWR22 108 - 85 4 2 2 2 1 1 1 - GWR42 278 - 85 12 7 5 5 4 3 2 - GWR44 310 - 85 12 8 7 5 4 4 3 - GWR84 640 - 115 35 23 20 17 13 9 7 5 64 x 52 1 1 1 1 - - - - 90 X 52 2 1 1 1 - - - - 37 - 85 2 - - - - - - - 108 - 85 4 2 2 2 1 1 1 - 125 - 85 5 3 2 2 1 1 1 - 125 - 85 5 3 2 2 1 1 1 - 310 - 115 17 11 9 8 6 4 3 2 GWR11N 110 110 84 96 96 53 102 102 - 0,30 A GWR14N 140 140 84 124 124 53 132 132 - 0,40 A GWR21(1) 175 87,5 120 123 72 88 165 77,5 - 0,88 A GWR22(1) 175 175 120 162 123 88 165 165 135 - 135 1,25 A GWR42(1) 360 175 120 308 162 88 352 165 320 - 135 2,50 A GWR44(1) 360 360 120 346 308 88 352 352 320 - 320 3,40 A GWR84(1) 730 360 166 670 340 120 720 350 670 - 310 8,00 A GWR11 12 x 1 8 x 1 6 x 1 5 x 1 3 x 1 3 x 1 1 x 1 1 x 1 - GWR14 18 x 1 10 x 1 8 x 1 7 x 1 5 x 1 4 x 1 2 x 1 1 x 1 - GWR21 18 x 1 10 x 1 8 x 1 7 x 1 5 x 1 4 x 1 2 x 1 1 x 1 - GWR22 20 x 1 10 x 1 10 x 1 6 x 1 6 x 1 4 x 1 2 x 1 1 x 1 135 - 135 GWR42 48 x 1 28 x 1 24 x 1 20 x 1 12 x 1 10 x 1 4 x 1 2 x 1 320 - 135 GWR44 48 x 2 28 x 2 24 x 2 20 x 2 12 x 2 10 x 2 8 x 1 4 x 1 320 - 320 GWR84 120 x 2 70 x 2 60 x 2 50 x 2 44 x 2 30 x 2 20 x 1 14 x 1 670 - 310 A 126 - Feam Catalogue 01 Ex Enclosures GWR Technical Features GWR Body Enclosures Drilling Layout gwr Indicative quantity of terminals and relevant section ENCLOSURE CODE DRILLING AREA A-B [mm] QUANTITY ALLOWED ENTRIES FOR SIZE (from 1 to size 8) 1 2 3 4 5 6 7 8 DRILLING AREA A-B [mm] QUANTITY ALLOWED ENTRIES FOR SIZE (from 1 to size 8) 1 2 3 4 5 6 7 8 Reference Details Reference Details wall DRILLING AREA REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. CODE A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] H [mm] INT. PLATE X - Y [mm] WEIGHT [Kg] DETAIL CODE ENCLOSURE SECT. 2,5 [mm/sq] SECT. 6,0 [mm/sq] SECT. 10,0 [mm/sq] SECT. 16,0 [mm/sq] SECT. 35,0 [mm/sq] SECT. 50,0 [mm/sq] SECT. 70,0 [mm/sq] SECT.240,0 [mm/sq] INT.PLATE X - Y [mm] (1) ENCLOSURE’S COLOUR: N = DARK GREY RAL7021 - B = LIGHT BLUE RAL5015 / EXAMPLE: GWR14N = COLOUR DARK GREY RAL 7021 GWR42B = COLOUR LIGHT BLUE RAL5015 PLATE X-Y
  • 33. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment GWRCS-ESX GWRCS - ESX Feam Catalogue 01 - 127 Ex Enclosures Mechanical characteristics - GWRCS Body glass fibre reinforced polyester resin color dark grey RAL 7021 Cover glass fibre reinforced polyester resin color dark grey RAL 7021 Screws stainless steel Internal plate stainless steel - aluminium Gasket silicon Strenght 4 Joule impact resistance Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D GRP and STAINLESS STEEL Ex-de PUSH BUTTON STATIONS On Request Accessories: • External epoxy painting with colour on request • Internal anticondensate painting orange RAL 2004 (ESX) • Drain and breather valves • Removable flanges (only stainless steel enclosures) Mechanical characteristics - ESX Body stainless steel AISI 316l sp. 1,5mm Cover stainless steel AISI 316l sp. 1,5mm Screws stainless steel AISI 316L Internal plate stainless steel AISI 316L Gasket silicon Strenght 4 Joule di resistenza all'urto JUNCTION BOX FOR CONTROL. SWITCHGEAR and SIGNALLING - GWRCS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex ed IIC T6 II 2 D Ex tD A21 T85°C 2Ex ed IIC T6 DIP A21 TA 85°C 2Ex ed IIC T6 DIP A21 TA 85°C INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. LOM 02 ATEX 2024 POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-0; EN 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002 JUNCTION BOX FOR CONTROL. SWITCHGEAR and SIGNALLING - ESX ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K EXECUTION II 2 G Ex e II T5 II 2 G Ex e [ia] IIB/IIC T5 II 2 D Ex tD A21 T100°C 2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X, 2Ex e [ia] IIB/IIC T4, T5 X DIP A21 TA 100°C 2Ex e II T5 X, 0Ex ia IIB/IIC T4…T6 X, 2Ex e [ia] IIB/IIC T4, T5 X DIP A21 TA 100°C AMBIENT TEMPERATURE -50°C ÷ +175°C -50°C ÷ +175°C -50°C ÷ +175°C PROTECTION DEGREE IP66 IP66 IP66 CERTIFICATE REF. INERIS 02 ATEX 0067X POCC IT. ГБ05.B02537 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-7; EN 60079-11; 61241-1 ГОСТ Р 51330.9-99 (МЭК 60079-10-95) ГОСТ Р 51330.13-99 (МЭК 60079-14-96) ГОСТ Р МЭК 61241-3-99 ГОСТ Р 51330.0 / 1 / 8 / 14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 34. YOUR PARTNER FOR SAFETY Since 1961 GWRCS-ESX NPOT S Y CN EG R EME S UAT O T POT S Y CN EG R EME S UA ON T OPOT S Y CN EG R EME S UA N T POT S Y CN EG R EME S UA ON T POT S Y CN EG R EME S UA ON 220 A A A A 10 10 10 10 10 10 10 10 10 10 10 A 10 10 520242 165148.5 330148.5 120 359.5 120 120 175 175 360 175 359.5 420 ESX 5242 ESX 2216 ESX 3333 GWRCS 44 GWRCS 42 GWRCS 22 NPOT S Y CN EG R EME S UAT O T POT S Y CN EG R EME S UA ON T OPOT S Y CN EG R EME S UA N T POT S Y CN EG R EME S UA ON T POT S Y CN EG R EME S UA ON 220 A A A A 10 10 10 10 10 10 10 10 10 10 10 A 10 10 520242 165148.5 330148.5 120 359.5 120 120 175 175 360 175 359.5 420 ESX 5242 ESX 2216 ESX 3333 GWRCS 44 GWRCS 42 GWRCS 22 NPOT S Y CN EG R EME S UAT O T POT S Y CN EG R EME S UA ON T OPOT S Y CN EG R EME S UA N T POT S Y CN EG R EME S UA ON T POT S Y CN EG R EME S UA ON 220 A A A A 10 10 10 10 10 10 10 10 10 10 10 A 10 10 520242 165148.5 330 330 148.5 120 359.5 120 120 175 175 360 175 359.5 420 ESX 5242 ESX 2216 ESX 3333 GWRCS 44 GWRCS 42 GWRCS 22 NPOT S Y CN EG R EME S UAT O T POT S Y CN EG R EME S UA ON T OPOT S Y CN EG R EME S UA N T POT S Y CN EG R EME S UA ON T POT S Y CN EG R EME S UA ON 220 A A A A 10 10 10 10 10 10 10 10 10 10 10 A 10 10 520242 165148.5 330 330 148.5 120 359.5 120 120 175 175 360 175 359.5 420 ESX 5242 ESX 2216 ESX 3333 GWRCS 44 GWRCS 42 GWRCS 22 NPOT S Y CN EG R EME S UAT O T POT S Y CN EG R EME S UA ON T OPOT S Y CN EG R EME S UA N T POT S Y CN EG R EME S UA ON T POT S Y CN EG R EME S UA ON 220 A A A A 10 10 10 10 10 10 10 10 10 10 10 A 10 10 520242 165148.5 330 330 148.5 120 359.5 120 120 175 175 360 175 359.5 420 ESX 5242 ESX 2216 ESX 3333 GWRCS 44 GWRCS 42 GWRCS 22 NPOT S Y CN EG R EME S UAT O T POT S Y CN EG R EME S UA ON T OPOT S Y CN EG R EME S UA N T POT S Y CN EG R EME S UA ON T POT S Y CN EG R EME S UA ON 220 A A A A 10 10 10 10 10 10 10 10 10 10 10 A 10 10 520242 165148.5 330 330 148.5 120 359.5 120 120 175 175 360 175 359.5 420 ESX 5242 ESX 2216 ESX 3333 GWRCS 44 GWRCS 42 GWRCS 22 GWRCS 44 ESX 5242 GWRCS 22 ESX 3333 GWRCS 42 ESX 2216 128 - Feam Catalogue 01 Ex Enclosures GWRCS - ESX Typical installation REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. GWRCS - ESX examples of application
  • 35. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment ES ES Feam Catalogue 01 - 129 Waterproof Enclosures JUNCTION BOXES On Request Accessories: • External epoxy painting with colour on request • Internal anticondensate painting orange RAL-2004 • Drain and breather valves Mechanical characteristics Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless steel Internal plate hot dip galvanized steel / aluminium Gasket silicon rubber Installation: Safe Areas Classification: IP66 JUNCTION BOX CEI / EN EXECUTION INDUSTRIAL WATERPROOF AMBIENT TEMPERATURE - PROTECTION DEGREE IP66 CERTIFICATE REF. - RULES OF COMPLIANCE EN 60529
  • 36. YOUR PARTNER FOR SAFETY Since 1961 ES ES1313 130 130 85 115 115 71 114 114 112 - 70 1,20 A ES1717 170 170 95 155 155 81 154 154 150 - 150 1,50 A ES2216 220 160 95 205 145 81 204 144 200 - 100 3,80 A ES2222 220 220 110 205 205 97 204 204 200 - 160 4,40 A ES3322 330 220 120 312 202 103 316 206 294 - 154 6,40 A ES3333 330 330 130 310 310 114 316 316 290 - 290 8,80 A ES4433 440 330 150 420 310 155 426 316 400 - 290 11,40 A ES5242 520 420 180 496 396 165 506 406 460 - 370 20,20 A ES6348 630 480 180 610 460 165 598 466 550 - 400 21,30 A A F C B GxH DxE ES1313 88 x55 2 1 1 1 / / / / ES1717 150 x 70 5 3 2 2 2 1 / / ES2216 200 x 70 6 3 3 3 2 2 / / ES2222 200 x 85 8 5 3 3 3 2 2 / ES3322 285 x 90 12 7 6 5 4 3 3 / ES3333 275 x 90 12 7 6 5 4 3 2 / ES4433 370 x 110 20 14 12 12 6 5 3 / ES5242 420 x 145 30 18 16 12 12 8 4 2 ES6348 500 x 140 36 24 18 16 12 10 6 4 88 x55 2 1 1 1 / / / / 150 x 70 5 3 2 2 2 1 / / 120 x 70 4 2 2 2 1 1 / / 200 x 85 8 5 3 3 3 2 2 / 200 x 90 8 5 4 4 3 2 2 / 275 x 90 12 7 6 5 4 3 2 / 265 x 110 14 10 8 8 4 3 2 / 360 x 145 28 18 14 11 10 7 4 3 400 x 140 30 21 15 12 10 8 4 3 A B C D ES1313 10 x 1 5 x 1 4 x 1 4 x 1 3 x 1 2 x 1 1 x 1 / 112 - 70 ES1717 20 x 1 10 x 1 8 x 1 8 x 1 6 x 1 3 x 1 2 x 1 1 x 1 150 - 150 ES2216 30 x 1 18 x 1 14 x 1 10 x 1 8 x 1 3 x 1 2 x 1 1 x 1 200 - 200 ES2222 26 x 1 16 x 1 12 x 1 10 x 1 8 x 1 4 x 1 2 x 1 2 x 1 200 - 160 ES3322 46 x 1 26 x 1 22 x 1 18 x 1 14 x 1 10 x 1 6 x 1 2 x 1 294 - 154 ES3333 46 x 2 24 x 2 22 x 2 16 x 2 14 x 2 10 x 1 8 x 1 3 x 1 290 - 290 ES4433 70 x 2 40 x 2 32 x 2 26 x 2 20 x 2 14 x 2 10 x 1 4 x 1 400 - 290 ES5242 70 x 3 44 x 3 34 x 3 30 x 3 22 x 3 18 x 2 14 x 1 6 x 1 460 - 370 ES6348 120 x 3 76 x 3 60 x 3 50 x 3 34 x 3 30 x 2 24 x 1 12 x 1 685 - 340 A CODE A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] H [mm] INT.PLATE X - Y [mm] WEIGHT [Kg] DETAIL 130 - Feam Catalogue 01 Waterproof Enclosures ES Technical Features ES Body Enclosures Drilling Layout ES Indicative quantity of terminals and relevant section ENCLOSURE CODE DRILLING AREA A-B [mm] QUANTITY ALLOWED ENTRIES FOR SIZE (from 1 to size 8) 1 2 3 4 5 6 7 8 DRILLING AREA C-D [mm] QUANTITY ALLOWED ENTRIES FOR SIZE (from 1 to size 8) 1 2 3 4 5 6 7 8 wall DRILLING AREA Reference Details Reference Details REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. CODE ENCLOSURE SECT. 2,5 [mm/sq] SECT. 6,0 [mm/sq] SECT. 10,0 [mm/sq] SECT. 16,0 [mm/sq] SECT. 35,0 [mm/sq] SECT. 50,0 [mm/sq] SECT. 70,0 [mm/sq] SECT. 240,0 [mm/sq] INT.PLATE X - Y [mm] PLATE X-Y