Explosion Proof Electrical Equipment
EFG
EFG
Feam Catalogue 03 - 1
EX Control Stations
MULTIPLE CONTROL
STATIONS
On request accessories:
•External epoxy painting with colour on request
•Cable entries with different threads from standards
Mechanical characteristics	
Body marine grade copper free aluminium light alloy
Cover marine grade copper free aluminium light alloy
Screws stainless steel
Internal plate hot dip galvanized steel
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts)
Classification: Group II - Category 2G 2D
MULTIPLE CONTROL STATIONS
ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K
EXECUTION
II 2 G Ex d IIB T5/T6 Gb
II 2 D Ex tb IIIC T85°C/T100°C Db
Ex d IIB T5/T6 Gb
Ex tb IIIC T85°C/T100°C Db
Ex d IIB T5/T6 Gb
Ex tb IIIC T85°C/T100°C Db
Ex d IIB T5 (T6) Gb
Ex tb IIIC T85°C (T100°C) Db
Ex d IIB T5 (T6) Gb
Ex tb IIIC T85°C (T100°C) Db
AMBIENT
TEMPERATURE
-60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C
PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66
CERTIFICATE REF. INERIS 03 ATEX 0047 IECEx INE 11.0034X - POCC IT. ME92.B02924 No. 07/43-269
RULES OF
COMPLIANCE
EN 60079-0;
EN 60079-1;
EN 60079-31
IEC 60079-0;
IEC 60079-1;
IEC 60079-31
ABNT NBR IEC 60079-0;
ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-31
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004
ГОСТ Р 51330.0/1/8/14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
EFG
EFG6/ EFG6-A
EFG6 195 130 100 155 160 104 GK 1" 150 - 95 3,20 A
EFG6-A 195 130 125 175 160 104 GK 1” 150 - 95 3,50 A
F ØG B
C
D
E
A
A
EFG6 EFG6 EFG6
SCHEMA - "A" SCHEMA - "B" SCHEMA - "C"SCHEMA - "A1"
EFG6
TERMINALS
SCHEMA - "B1"
EFG6
TERMINALS
EFG6
EFG10
1-2 1-2 1-2 1-23
3
3
2 - Feam Catalogue 03
EX Control Stations
EFG Technical Features
REMARK:
Due to the development of the national and international specifications and of the technology, the above technical characteristics showed
on this bulletin can be considered as binding on our confirmation only.
EFG Max. operators allowed diagrams
LEGEND:
1 EFP Push Button
2 EFL Pilot Light
3 EFI Handle Switch
MORE OPERATORS DETAILS ARE AVAILABLE ON “HANDLES-D” BULLETIN
REMARK - (A) twin holes 1-2 type, can be replaced by one hole 3 type
DIAGRAM “A” DIAGRAM “A1” DIAGRAM “B” DIAGRAM “B1” DIAGRAM “C”
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
INTERNAL PLATE
[mm]
WEIGHT
[Kg]
DETAIL
Reference details
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EFSC218
EFSC218
Feam Catalogue 03 - 3
Ex Control station
On request accessories:
•External epoxy painting with colour on request
•Cable entries with different threads from standard
Mechanical characteristics	
Body marine grade copper free aluminium light alloy
Cover marine grade copper free aluminium light alloy
Screws stainless steel
Internal plate hot dip galvanized steel
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
THERMAL MAGNETIC AND EARTH
LEAKAGE CIRCUIT BREAKERS,
SELECTOR AND FUSED SWITCHES
CIRCUIT BREAKERS AND SWITCHES
ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K
EXECUTION
II 2 G Ex d IIB T5/T6 Gb
II 2 D Ex tb IIIC T85°C/T100°C Db
Ex d IIB T5/T6 Gb
Ex tb IIIC T85°C/T100°C Db
Ex d IIB T5/T6 Gb
Ex tb IIIC T85°C/T100°C Db
Ex d IIB T5 (T6) Gb
Ex tb IIIC T85°C (T100°C) Db
Ex d IIB T5 (T6) Gb
Ex tb IIIC T85°C (T100°C) Db
AMBIENT
TEMPERATURE
-60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C
PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66
CERTIFICATE REF. INERIS 03 ATEX 0047 IECEx INE 11.0034X - POCC IT. ME92.B02925 No. 07/43-269
RULES OF
COMPLIANCE
EN 60079-0;
EN 60079-1;
EN 60079-31
IEC 60079-0;
IEC 60079-1;
IEC 60079-31
ABNT NBR IEC 60079-0;
ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-31
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004
ГОСТ Р 51330.0/1/8/14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
EFSC218
EFSC218GUSV3225 EFSC218GUSV3425 25A D
EFSC218GUSV3240 EFSC218GUSV3440 40A D
- EFSC218GUSV3463 63A D
EFSC218M310 - 2 10A A
EFSC218M310L 1 1 10A A
FIGURA A
FIGURA C
FIGURA E
ØF
ØF
C E
D
A
B
EFSC2183I3V16 1 2 16A B
EFSC2183I3V25 1 1 25A B
FIGURA A FIGURA B
FIGURA C
FIGURA D
FIGURA E
ØF
ØF
C E
D
A
B
EFSC218GUSC3206 EFSC218GUSC3306 EFSC218GUSC3406 6A C
EFSC218GUSC3210 EFSC218GUSC3310 EFSC218GUSC3410 10A C
EFSC218GUSC3216 EFSC218GUSC3316 EFSC218GUSC3416 16A C
EFSC218GUSC3220 EFSC218GUSC3320 EFSC218GUSC3420 20A C
EFSC218GUSC3225 EFSC218GUSC3325 EFSC218GUSC3425 25A C
EFSC218GUSC3232 EFSC218GUSC3332 EFSC218GUSC3432 32A C
EFSC218GUSC3240 EFSC218GUSC3340 EFSC218GUSC3440 40A C
EFSC218GUSC3250 EFSC218GUSC3350 EFSC218GUSC3450 50A C
EFSC218GUSC3263 EFSC218GUSC3363 EFSC218GUSC3463 63A C
FIGURA A
FIGURA C
FIGURA E
ØF
ØF
C E
D
A
B
FIGURA A FIGURA B
FIGURA C
FIGURA D
FIGURA E
ØF
ØF
C E
D
A
B
EFSC218SMT034 0,20 - 0,35A E
EFSC218SMT036 0,35 - 0,60A E
EFSC218SMT301 0,60 - 1,00A E
EFSC218SMT302 1,00 - 1,60A E
EFSC218SMT303 1,60 - 2,50A E
EFSC218SMT304 2,50 - 4,00A E
EFSC218SMT306 4,00 - 6,60A E
EFSC218SMT310 6,00 - 10,00A E
EFSC218SMT316 10,00 - 16,00A E
FIGURA A
FIGURA C
FIGURA E
ØF
ØF
C E
D
A
B
EFSC218 M310
	 195	 185	 130	 118	 145	 GK 1”		
T5	 T100°C
EFSC218M310L 							 T4	 T125°C	
3,45	 A
EFSC218 3I3V25
	 195	 185	 130	 118	 145	 GK 1”	
	 T5 	 T100°C
EFSC218313V26								 T4	 T125°C	
3,10	 B
EFSC218 GUSC…	 195	 185	 130	 118	 155	 GK 1”	
	 T5 	 T100°C
									 T4	 T125°C	
3,10	 C
EFSC218 GUSV…	 195	 185	 130	 118	 145	 GK 1”	
	 T5 	 T100°C
									 T4	 T125°C	
3,20	 D
EFSC218 SMT…	 195	 185	 130	 118	 130	 GK 1”	
	 T5	 T100°C
									 T4	 T125°C	
2,90	 E
D
A
B
C
E
4 - Feam Catalogue 03
Ex Control station
EFSC218 Technical Features
EARTH LEAKAGE CIRCUIT BREAKERS 400/230V 50-60Hz 300mA 1PH+N - 3PH+N
TWO POLES THREE POLES RATE [In] DETAIL
SELECTOR SWITCHES 500V 50-60Hz
TYPE
SELECTOR SWITCHES Q.TY RATE
[In]
DETAIL
PADLOCK HANDLE NORMAL HANDLE
THREE POLES FUSE SWITCH 500V 50-60Hz
TYPE THREE POLE SWITCH E16 DELAYED FUSE
RATE
[In]
DETAIL
CIRCUIT BREACKERS CURVE “C” 415V 50-60Hz 6kA
TWO POLES THREE POLES FOUR POLES
RATE
[In]
DETAIL
THERMAL MAGNETIC MOTOR PROTECTION THREE POLES 660V 50-60Hz
TYPE RANGE DETAIL
REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
ØF
[mm]
TEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)
WEIGHT
[Kg] DETAIL
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EFDC
EFDC
EFDC3
EFDC1E
EFDC1
EFDC1EF
EFDC12R
Feam Catalogue 03 - 5
Ex Control station
On request accessories:
•External epoxy painting with colour on request
•Different threads from standard
Mechanical characteristics	
Body marine grade copper free aluminium light alloy
Cover marine grade copper free aluminium light alloy
Screws stainless steel
Gasket NBR rubber sealing ring
PUSH BUTTONS
AND CONTROL STATIONS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts)
Classification: Group II - Category 2G 2D
PUSH BUTTONS AND CONTROL STATIONS
ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K
EXECUTION
II 2 G Ex d IIC T5/T6 Gb
II 2 D Ex tb IIIC T85°C/T100°C Db
Ex d IIC T5/T6 Gb
Ex tb IIIC T85°C/T100°C Db
Ex d IIC T5/T6 Gb
Ex tb IIIC T85°C/T100°C Db
Ex d IIC T5 (T6) Gb
Ex tb IIIC T85°C (T100°C) Db
Ex d IIC T5 (T6) Gb
Ex tb IIIC T85°C (T100°C) Db
AMBIENT
TEMPERATURE
-60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C
PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66
CERTIFICATE REF. INERIS 04 ATEX 0076X IECEx INE 11.0033X - POCC IT. ME92.B02925 No. 07/43-269
RULES OF
COMPLIANCE
EN 60079-0;
EN 60079-1;
EN 60079-31
IEC 60079-0;
IEC 60079-1;
IEC 60079-31
ABNT NBR IEC 60079-0;
ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-31
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004
ГОСТ Р 51330.0/1/8/14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
EFDC
EFDC1 A
EFDC2 A
EFDC1E (*) C
EFDC1EF (**) F
EFDC1EFSR E
EFDC3R B
EFDC3V B
EFDC111R B
EFDC121R D
EFDC122R D
EFDC123R D
EFDC222R D
EFDC13R D
EFDC23R D
EFDC133R D
EFDC233R D
EFDC33R D
EFDC333R D
C
FIG. A
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
DON
TENSIONE
SOTTO
DON
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
FIG. B
FIG. DFIG. C
FIG. E FIG. F
A
B
ØED
ØE
FIG. A
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
DON
TENSIONE
SOTTO
DON
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
FIG. B
FIG. DFIG. C
FIG. E FIG. F
A
C
B
ØED
ØE
FIG. A
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
FIG. C
FIG. E
A
C
B
ØED
ØE
EFDC1/2	 120	 115	 95	 55	 GK 3/4”
	 T6 	 T85°C				
							 T5 	 T100°C	
0,90	 A
EFDC3	 120	 120	 95	 5	 GK 3/4”
	 T6	 T85°C	 			
							 T5	 T100°C	
0,90	 B
EFDC1E	 120	 135	 95	 55	 GK 3/4”
	 T6 	 T85°C		 	
							 T5 	 T100°C	
1,00	 C
EFDC…R	 140	 125	 100	 80	 GK 1”
	 T6	 T85°C	 	
							 T5 	 T100°C	
1,50	 D
EFDC1EFSR	 120	 160	 95	 55	 GK 3/4”
	 T6	 T85°C	 	
							 T5 	 T100°C	
0,90	 E
EFDC1EF	 120	 130	 95	 55	 GK 3/4”
	 T6	 T85°C	 	
							 T5 	 T100°C	
0,90	 F
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
FIG. B
FIG. D
FIG. F
A
B
ØED
ØE
C
C
FIG. A
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
FIG. B
FIG. DFIG. C
FIG. E FIG. F
A
B
ØED
ØE
FIG. A
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
FIG. B
FIG. DFIG. C
FIG. E FIG. F
A
B
ØED
ØE
C
A B C
ED F
6 - Feam Catalogue 03
Ex Control station
EFDC Technical Features
EFDC Standard operators layout			
REMARK:
Due to the development of the national and international specifications and of the technology, the above technical characteristics showed
on this bulletin can be considered as binding on our confirmation only.
* WITH BREAKING GLASS (EMERGENCY STOP)		
** WITH RED MUSHROOM EMERGENCY PUSH BUTTON
OPERATORS TYPE OPERATORS LAYOUT (QUANTITY)
PUSH BUTTON NO (1) 1 1 2 1 1 3
PUSH BUTTON NC (2) 1 1 1 - - -
PILOT LIGHT (3) 1 - - 2 1 -
EXAMPLES: EFDC123R EFDC12R EFDC112R EFDC133R EFDC13R EFDC111R
CODE DETAIL CODE DETAIL CODE DETAIL
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
TEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)
WEIGHT
[Kg] DETAIL
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EFSC
EFSC
EFSC2...
EFSC3...
EFSC5...
Feam Catalogue 03 - 7
Ex Control station
On request accessories:
•External epoxy painting with colour on request
•Different threads from standard
Mechanical characteristics	
Body marine grade copper free aluminium light alloy
Cover marine grade copper free aluminium light alloy
Screws stainless steel
Gasket NBR rubber sealing ring
ROTARY SWITCHES
AND SELECTOR SWITCHES
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts)
Classification: Group II - Category 2G 2D
MOTOR CONTROL SWITCHES - ROTARY SWITCHES - SELECTOR SWITCHES
ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K
EXECUTION
II 2 G Ex d IIC T5/T6 Gb
II 2 D Ex tb IIIC T85°C/T100°C Db
Ex d IIC T5/T6 Gb
Ex tb IIIC T85°C/T100°C Db
Ex d IIC T5/T6 Gb
Ex tb IIIC T85°C/T100°C Db
Ex d IIC T5 (T6) Gb
Ex tb IIIC T85°C (T100°C) Db
Ex d IIC T5 (T6) Gb
Ex tb IIIC T85°C (T100°C) Db
AMBIENT
TEMPERATURE
-60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C
PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66
CERTIFICATE REF. INERIS 04 ATEX 0076X IECEx INE 11.0033X - POCC IT. ME92.B02925 No. 07/43-269
RULES OF
COMPLIANCE
EN 60079-0;
EN 60079-1;
EN 60079-31
IEC 60079-0;
IEC 60079-1;
IEC 60079-31
ABNT NBR IEC 60079-0;
ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-31
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004
ГОСТ Р 51330.0/1/8/14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
EFSC
EFSC21 EFSC22 EFSC23 - 16A A
EFSC3125 EFSC3225 EFSC3325 EFSC3425 25A B
EFSC5125 EFSC5225 EFSC5325 EFSC5425 25A C
EFSC3132 EFSC3232 EFSC3332 EFSC3432 32A B
EFSC5132 EFSC5232 EFSC5332 EFSC5432 32A C
EFSC21D EFSC22D - - 16A A
EFSC3125D EFSC3225D EFSC3325D (1) 25A B
EFSC5125D EFSC5225D EFSC5325D (1) 25A C
EFSC3132D EFSC3232D EFSC3332D (1) 32A B
EFSC5132D EFSC5232D EFSC5332D (1) 32A C
EFSC21C EFSC22C - - 16A A
EFSC3125C EFSC3225C EFSC3325C (1) 25A B
EFSC5125C EFSC5225C EFSC5325C (1) 25A C
EFSC3132C EFSC3232C EFSC3332C (1) 32A B
EFSC5132C EFSC5232C EFSC5332C (1) 32A C
EFSC310R 10A EFSC316R 16A R B
EFSC310X 10A EFSC316X 16A X B
EFSC310Y 10A EFSC316Y 16A Y B
EFSC310W 10A EFSC316W 16A W B
EFSC310Z 10A EFSC316Z 16A Z B
EFSC510R 10A EFSC516R 16A R C
EFSC510X 10A EFSC516X 16A X C
EFSC510Y 10A EFSC516Y 16A Y C
EFSC510W 10A EFSC516W 16A W C
EFSC510Z 10A EFSC516Z 16A Z C
EFSC2…	 120	 135	 95	 55	 GK 3/4”
	 T6	 T85°C				
							 T5	 T100°C	
0,90	 A
EFSC3…	 140	 150	 100	 80	 GK 1”
	 T6	 T85°C
							 T5	 T100°C	
1,00	 B
EFSC5…	 165	 170	 150	 115	 -
	 T6	 T85°C
							 T5	 T100°C	
1,80	 C
OFF
10.88.32
SOTTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DONOT
TENSIONE
OFF
10.88.32
FIG. A
FIG
A
C
B
ØED
ØE
OFF
10.88.32
SO
TT
O
ENERGIZED
NONAPRIRE
WHILE
OPEN
DO
NO
T
TENSION
E
OFF
10.88.32
FIG. B
OFF
10.88.32
FIG. A
FIG. C
A
C
B
D
OFF
10.88.32
SO
TTO
ENERGIZED
NONAPRIRE
WHILE
OPEN
DO
NO
T
TENSIONE
OFF
10.88.32
FIG. B
OFF
10.88.32
FIG. A
FIG. C
A
C
B
ØED
ØE
M
O
A-B
1
4
2
3
5
8
6
7
M
O
A-B
1
4
2
3
5
8
6
7
M
O F-B 1
4
2
3
5
8
6
7
O
A
M
O-B
A 1
4
2
3
AU AM 1
4
2
3
TIPO "R" TIPO "X" TIPO "Y" TIPO "W" TIPO "Z"
M
O
A-B
1
4
2
3
5
8
6
7
M
O
A-B
1
4
2
3
5
8
6
7
M
O F-B 1
4
2
3
5
8
6
7
O
A
M
O-B
A 1
4
2
3
AU AM 1
4
2
3
TIPO "R" TIPO "X" TIPO "Y" TIPO "W" TIPO "Z"
M
O
A-B
1
4
2
3
5
8
6
7
M
O
A-B
1
4
2
3
5
8
6
7
M
O F-B 1
4
2
3
5
8
6
7
O
A
M
O-B
A 1
4
2
3
AU AM 1
4
2
3
TIPO "R" TIPO "X" TIPO "Y" TIPO "W" TIPO "Z"
M
O
A-B
1
4
2
3
5
8
6
7
M
O
A-B
1
4
2
3
5
8
6
7
M
O F-B 1
4
2
3
5
8
6
7
O
A
M
O-B
A 1
4
2
3
AU AM 1
4
2
3
TIPO "R" TIPO "X" TIPO "Y" TIPO "W" TIPO "Z"
M
O
A-B
1
4
2
3
5
8
6
7
M
O
A-B
1
4
2
3
5
8
6
7
M
O F-B 1
4
2
3
5
8
6
7
O
A
M
O-B
A 1
4
2
3
AU AM 1
4
2
3
TIPO "R" TIPO "X" TIPO "Y" TIPO "W" TIPO "Z"
A
C
B
8 - Feam Catalogue 03
TYPE “R”
Contactor control with
mantained OFF position
TYPE “X”
Contactor control
TYPE “Y”
Reverse motor
starter control
TYPE “W”
Impulse control
TYPE “Z”
MAN. AUT. control
Ex Control station
EFSC Technical Features
REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
ON/OFF SWITCHES 500V 50/60Hz RATE
[In]
DETAIL
1 POLE 2 POLES 3 POLES 4 POLES
TWO WAY SWITCHES 500V 50/60Hz RATE
[In]
DETAIL
1 POLE 2 POLES 3 POLES 4 POLES
CHANGE OVER SWITCHES 500V 50/60Hz RATE
[In]
DETAIL
1 POLE 2 POLES 3 POLES 4 POLES
SELECTOR SWITCHES 500V 50/60Hz
DIAGRAM DETAIL
TYPE RATE [In] TYPE RATE [In]
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
ØE
[mm]
TEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)
WEIGHT
[Kg]
DETAIL
EFSC Motor switch diagram arrangements
*DIAGRAM ARRANGEMENTS DIFFERENT THAN STANDARD, PLEASE CONTACT OUR SALES DEPT.
(1): On request only
(1): On request only
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EF…3D–EF…3T
EF…3D – EF…3T
EFDC3D
EFDC3T
Feam Catalogue 03 - 9
Ex Control Stations
On request accessories:
•External epoxy painting with colour on request
•Cable entries with different thread from standard
Mechanical characteristics	
Body marine grade copper free aluminium light alloy
Cover marine grade copper free aluminium light alloy
Screws stainless steel
Gasket NBR rubber sealing ring
MULTIPLE CONTROL
STATIONS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts)
Classification: Group II - Category 2G 2D
MULTIPLE CONTROL STATIONS - ROTARY SWITCHES - SELECTOR SWITCHES
ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K
EXECUTION
II 2 G Ex d IIC T5/T6 Gb
II 2 D Ex tb IIIC T85°C/T100°C Db
Ex d IIC T5/T6 Gb
Ex tb IIIC T85°C/T100°C Db
Ex d IIC T5/T6 Gb
Ex tb IIIC T85°C/T100°C Db
Ex d IIC T5 (T6) Gb
Ex tb IIIC T85°C (T100°C) Db
Ex d IIC T5 (T6) Gb
Ex tb IIIC T85°C (T100°C) Db
AMBIENT
TEMPERATURE
-60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C
PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66
CERTIFICATE REF. INERIS 04 ATEX 0076X IECEx INE 11.0033X - POCC IT. ME92.B02925 No. 07/43-269
RULES OF
COMPLIANCE
EN 60079-0;
EN 60079-1;
EN 60079-31
IEC 60079-0;
IEC 60079-1;
IEC 60079-31
ABNT NBR IEC 60079-0;
ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-31
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004
ГОСТ Р 51330.0/1/8/14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
EF…3D–EF…3T
ØE
C
D
B
A
F
G / G.1*
ØE
D
B
A
F
G.1*
G
EF…3D 145 295 147,5 120 9 1" NPT 145 125
T6
T5
T85°C
T100°C
A
EF…3T 145 425 130 120 9 1" NPT 145 125
T6
T5
T85°C
T100°C
B
A
A
B
B
10 - Feam Catalogue 03
Ex Control Stations
EF…3D – EF…3T - Technical Features
REMARK: Due to the development of the national and international specifications and of the technology, the above technical
characteristics showed on this bulletin can be considered as binding on our confirmation only.
1 MUSHROOM PUSH
BUTTON
1 SWITCH
1 INSTRUMENT (low lid)
1 PILOT LIGHT
1 CHANGE OVER
SWITCH
1 PUSH BUTTON NO
1 PUSH BUTTON NC
OPERATOR ARRANGEMENT:
ON EACH COVER IS POSSIBLE TO FIT THE FOLLOWING MATERIAL:
• 1 48x48 INSTRUMENT (low lid with glass)
• UP TO 3 PILOT LIGHTS (as EFDC…R, see bulletin 65)
• UP TO 3 PUSH BUTTON (as EFDC…R, see bulletin 65)
• 1 MUSHROOM PUSH BUTTON (as EFDC…, see bulletin 65)
• 1 SELECTOR SWITCH (as EFSC…, see bulletin 66)
*LOW LID, ONLY FOR GLASS WINDOW
EF…3D – EF…3T - installation examples
Reference details
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
Ø E
[mm]
F
[mm]
G
[mm]
G.1
[mm]
TEMPERATURE
CLASS (GAS)
TEMPERATURE
CLASS (DUSTS)
DETAIL
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
CPSC/CPH–FSQCA-FSQC/BPA
CPSC / CPH
FSQCA-FSQC / BPA
fsqca/fsqc
CPSC/CPH
fsqc125/BP
Feam Catalogue 03 - 11
Ex Interlocked sockets & plugs
On request accessories:
•External epoxy painting with colour on request
•Cable entries with different thread from standard
Mechanical characteristics	
Body marine grade copper free aluminium light alloy
Cover marine grade copper free aluminium light alloy
Screws stainless steel
Pins brass
INTERLOCKED SWITCH
SOCKETS & PLUGS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts)
Classification: Group II - Category 2G 2D
Certified
Nema Type 4X
SWITCH SOCKETS & PLUGS
ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K
EXECUTION
II 2 G Ex d IIC T6
II 2 D Ex tD A21 T85°C
Ex d IIC T6
Ex tD A21 T85°C
Ex d IIC T6
Ex tD A21 T85°C
1 Ex d IIC T6
DIP A21 TA 85°C
1 Ex d IIC T6
DIP A21 TA 85°C
installation ZONE 1 / 2 - ZONE 21 / 22
PROTEC. DEGREE IP66/67 IP66/67 IP66/67 IP66/67 IP66/67
CERTIFICATE REF. IMQ 08 ATEX 016 - - POCC IT. ME92.B02925 No. 07/43-269
RULES OF
COMPLIANCE
EN 60079-0 : 2006;
EN 60079-1 : 2004;
EN 61241-0 : 2006;
EN 61242-1 : 2004
IEC 60079-0;
IEC 60079-1;
IEC 60079-31
ABNT NBR IEC 60079-0;
ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-31
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004
ГОСТ Р 51330.0/1/8/14-99
ГОСТ Р МЭК 61241-1-1-2002
SWITCH SOCKETS & PLUGS (125A RAT. ONLY)
ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K
EXECUTION
II 2 G Ex d IIC T6
II 2 D Ex tD A21 T85°C
Ex d IIC T6
Ex tD A21 T85°C
Ex d IIC T6
Ex tD A21 T85°C
1 Ex d IIC T6
DIP A21 TA 85°C
1 Ex d IIC T6
DIP A21 TA 85°C
installation ZONE 1 / 2 - ZONE 21 / 22
PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66
CERTIFICATE REF. IMQ 09 ATEX 015 - - POCC IT. ME92.B02925 No. 07/43-269
RULES OF
COMPLIANCE
EN 60079-0 : 2006;
EN 60079-1 : 2004;
EN 61241-0 : 2006;
EN 61242-1 : 2004
IEC 60079-0;
IEC 60079-1;
IEC 60079-31
ABNT NBR IEC 60079-0;
ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-31
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004
ГОСТ Р 51330.0/1/8/14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
CPSC/CPH–FSQCA-FSQC/BPA
E
ØF
ØF
ØG
D
HxL
B
A
ØC
E
ØF
ØF
ØG
D
HxL
B
A
ØC
E
ØF
GxH
D
ØC
A
B
CPSC / CPH 195 370 113 155 140 3/4" NPT 1" NPT 92-90 T6 T85°C 2,80 A
FSQC / BPA 230 415 155 200 163 1" NPT 1"NPT 125-80 T6 T85°C 4,00 B
FSQC125 / BP125 380 615 275 305 225 - 1-1/2" NPT 308x270 T6 T85°C 15,5 C
CPSC224-25A CPH224-25A 2P+T (PE) 24V 16A-25A
CPSC248-25A CPH248-25A 2P+T (PE) 48V 16A-25A
CPSC211-25A CPH211-25A 2P+T (PE) 110/130V 16A-25A
CPSC222-25A CPH222-25A 2P+T (PE) 220/250V 16A-25A
CPSC338-25A CPH338-25A 3P+T (PE) 380/415V 16A-25A
CPSC3381-25A CPH3381-25A 3P+T (PE) 480/500V 16A-25A
CPSC438-25A CPH438-25A 3P+N+T (PE) 380/415V 16A-25A
CPSC4381-25A CPH4381-25A 3P+N+T (PE) 480/500V 16A-25A
FSQC235 BPA235 2P+T (PE) 220/250V 32A
FSQC335 BPA335 3P+T (PE) 380/415V 32A
FSQC3351 BPA3351 3P+T (PE) 480/500V 32A
FSQC435 BPA435 3P+N+T (PE) 380/415V 32A
FSQC4351 BPA4351 3P+N+T (PE) 480/500V 32A
FSQC260 BPA260 2P+T (PE) 220/250V 63A
FSQC360 BPA360 3P+T (PE) 380/415V 63A
FSQC3601 BPA3601 3P+T (PE) 480/500V 63A
FSQC460 BPA460 3P+N+T (PE) 380/415V 63A
FSQC4601 BPA4601 3P+N+T (PE) 480/500V 63A
FSQCA235 BPA235 2P+T (PE) 220/250V 32A
FSQCA335 BPA335 3P+T (PE) 380/400V 32A
FSQCA260 BPA260 2P+T (PE) 220/250V 63A
FSQCA360 BPA360 3P+T (PE) 380/400V 63A
FSQC125-3 BP125-3 3P+T (PE) 380/415V 125A
FSQC125-31 BP125-31 3P+T (PE) 480/500V 125A
FSQC125-4 BP125-4 4P+T (PE) 380/415V 125A
FSQC125-41 BP125-41 4P+T (PE) 480/500V 125A
20-25V
40-50V
100-130V
200-250V
380-480V
480-500V
A
B
C
12 - Feam Catalogue 03
Ex Interlocked sockets & plugs
CPSC/FSQC - Technical Features
INTERLOCKED SOCKET AND PLUGS
SOCKET TYPE PLUG TYPE POLES VOLTAGE (50/60Hz) CURRENT
INTERLOCKED SOCKETS AND PLUGS WITH ON-LOAD SWITCH
SOCKET TYPE PLUG TYPE POLES VOLTAGE (50/60Hz) CURRENT
INTERLOCKED SOCKETS AND PLUGS WITH CIRCUIT BREAKER
SOCKET TYPE PLUG TYPE POLES VOLTAGE (50/60Hz) CURRENT
125A INTERLOCKED SOCKETS AND PLUGS
SOCKET TYPE PLUG TYPE POLES VOLTAGE (50/60Hz) CURRENT
REMARK: Due to the development of the national and international specifications and of the technology, the above technical
characteristics showed on this bulletin can be considered as binding on our confirmation only.
Sockets and plugs colour marking for industrial applications
NOMINAL WORKING VOLTAGE COLOUR
20-25V violet
40-50V WHITE
100-130V YELLOW
200-250V BLUE
380-480V RED
480-500V BLACK
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
Ø F
[mm]
Ø G
[mm]
FIXING
HxI [mm]
TEMPERATURE
CLASS (GAS)
TEMPERATURE
CLASS
(DUSTS)
WEIGHT
[Kg]
DETAIL
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
CPSCP–FSQCP/BP
CPSCP - FSQCP / BP
Feam Catalogue 03 - 13
Ex Interlocked sockets & plugs
On request accessories:	
•External epoxy painting with colour on request
•Cable entries with different thread from standard
INTELOCKED PANEL SWITCH
SOCKETS & PLUGS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts)
Classification: Group II - Category 2G 2D
Mechanical characteristics	
Body marine grade copper free aluminium light alloy
Cover marine grade copper free aluminium light alloy
Screws stainless steel
Pins brass
INTELOCKED PANEL SWITCH SOCKETS & PLUGS
ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K
EXECUTION
II 2 G Ex d IIC T6
II 2 D Ex tD A21 T85°C
Ex d IIC T6
Ex tD A21 T85°C
Ex d IIC T6
Ex tD A21 T85°C
1 Ex d IIC T6
DIP A21 TA 85°C
1 Ex d IIC T6
DIP A21 TA 85°C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22
PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66
CERTIFICATE REF. IMQ 08 ATEX 015 - - POCC IT. ME92.B02925 No. 07/43-269
RULES OF
COMPLIANCE
EN 60079-0 : 2006;
EN 60079-1 : 2004;
EN 61241-0 : 2006;
EN 61242-1 : 2004
IEC 60079-0;
IEC 60079-1;
IEC 60079-31
ABNT NBR IEC 60079-0;
ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-31
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004
ГОСТ Р 51330.0/1/8/14-99
ГОСТ Р МЭК 61241-1-1-2002
YOUR PARTNER FOR SAFETY
Since 1961
CPSCP–FSQCP/BP
CPSCP*/CPH 243 T6 T85°C 1,50 A
FSQCP*/BP 255 T6 T85°C 2,00 B
FSQCP125*/BP125 310 T6 T85°C 5,00 C
CPSCP224 2P+T (PE) 24V 16A
CPSCP224-25A 2P+T (PE) 24V 25A
CPSCP248 2P+T (PE) 48V 16A
CPSCP248-25A 2P+T (PE) 48V 25A
CPSCP211 2P+T (PE) 110/130V 16A
CPSCP211-25A 2P+T (PE) 110/130V 25A
CPSCP222 2P+T (PE) 220/250V 16A
CPSCP222-25A 2P+T (PE) 220/250V 25A
CPSCP338 2P+T (PE) 380/415V 16A
CPSCP338 2P+T (PE) 480/500V 16A
CPSCP338-25A 3P+T (PE) 380/415V 25A
CPSCP3381-25A 3P+T (PE) 480/500V 25A
CPSCP438-25A 3P+N+T (PE) 380/415V 25A
CPSCP4381-25A 3P+N+T (PE) 480/500V 25A
FSQCP235 2P+T (PE) 220/250V 32A
FSQCP335 3P+T (PE) 380/415V 32A
FSQCP3351 3P+T (PE) 480/500V 32A
FSQCP435 4P+T (PE) 380/415V 32A
FSQCP4351 4P+T (PE) 480/500V 32A
FSQCP260 2P+T (PE) 220/250V 63A
FSQCP360 3P+T (PE) 380/415V 63A
FSQCP3601 3P+T (PE) 480/500V 63A
FSQCP460 4P+T (PE) 380/415V 63A
FSQCP4601 4P+T (PE) 480/500V 63A
FSQCAP235 2P+T (PE) 220/250V 32A
FSQCAP335 3P+T (PE) 380/415V 32A
FSQCAP435 4P+T (PE) 380/415V 32A
FSQCAP260 2P+T (PE) 220/250V 63A
FSQCAP360 3P+T (PE) 380/415V 63A
FSQCAP460 4P+T (PE) 380/415V 63A
FSQCP125-3 BP125-3 3P+T (PE) 380/415V 125A
FSQCP125-31 BP125-31 3P+T (PE) 480/500V 125A
FSQCP125-4 BP125-4 4P+T (PE) 380/415V 125A
FSQCP125-41 BP125-41 4P+T (PE) 480/500V 125A
C
A A
A
GU
MATR.-ANNO
S. Nr.-YEAR
www.feam-ex.comS.r.l.
II 2G Ex d[ ] IICT
II 2D Ex tD [ ]A21 IP66T °C
BKI 08 ATEX 0480722
V Hz W A
Ta
NON APRIRE SOTTO TENSIONE /DO NOT OPEN WHILE ENERGIZED
AD OGNI APERTURA DEL COPERCHIO RIPRISTINARE IL GRASSO
AL SILICONE ACCERTARSI CHE LE VALVOLE DI RESPIRAZIONE
E DRENAGGIO SIANO SEMPRE CHIUSE
RENEW SILICONE GREASE EVERY TIME COVER IS OPENED
AND MAKE SURE THAT THE DRAIN AND
BREATHER VALVES ARE ALWAYS CLOSED
11.10.93
GU
MATR.-ANNO
S. Nr.-YEAR
www.feam-ex.comS.r.l.
II 2G Ex d[ ] IICT
II 2D Ex tD [ ]A21 IP66T °C
BKI 08 ATEX 0480722
V Hz W A
Ta
NON APRIRE SOTTO TENSIONE /DO NOT OPEN WHILE ENERGIZED
AD OGNI APERTURA DEL COPERCHIO RIPRISTINARE IL GRASSO
AL SILICONE ACCERTARSI CHE LE VALVOLE DI RESPIRAZIONE
E DRENAGGIO SIANO SEMPRE CHIUSE
RENEW SILICONE GREASE EVERY TIME COVER IS OPENED
AND MAKE SURE THAT THE DRAIN AND
BREATHER VALVES ARE ALWAYS CLOSED
11.10.93
Via M. Pagano, 3
I-20090Trezzano s/N
ITALY
www.feam-ex.com
II2 GD0722
CUSTODIA tipo
ENCLOSURE type
V Hz A
BKI 08 ATEX 019 Ta
W
Ex d IIB+H Ex tD A21 IP66T °C
NON APRIRE SOTTOTENSIONE
DO NOT OPENWHILE ENERGIZED
Ad ogni apertura del coperchio
ripristinare il grasso ai siliconi.
accertarsi che le valvole di respirazione
e drenaggio siano sempre chiuse
Renew silicone grease every tyme
cover is opened. and make sure
that the drain and breather valves
are always closed.
VA
11.00.88
S.r.l.
2 T
year s/n
GU
MATR.-ANNO
S. Nr.-YEAR
www.feam-ex.comS.r.l.
II 2G Ex d[ ] IICT
II 2D Ex tD [ ]A21 IP66T °C
BKI 08 ATEX 0480722
V Hz W A
Ta
NON APRIRE SOTTO TENSIONE /DO NOT OPEN WHILE ENERGIZED
AD OGNI APERTURA DEL COPERCHIO RIPRISTINARE IL GRASSO
AL SILICONE ACCERTARSI CHE LE VALVOLE DI RESPIRAZIONE
E DRENAGGIO SIANO SEMPRE CHIUSE
RENEW SILICONE GREASE EVERY TIME COVER IS OPENED
AND MAKE SURE THAT THE DRAIN AND
BREATHER VALVES ARE ALWAYS CLOSED
11.10.93
GU
MATR.-ANNO
S. Nr.-YEAR
www.feam-ex.comS.r.l.
II 2G Ex d[ ] IICT
II 2D Ex tD [ ]A21 IP66T °C
BKI 08 ATEX 0480722
V Hz W A
Ta
NON APRIRE SOTTO TENSIONE /DO NOT OPEN WHILE ENERGIZED
AD OGNI APERTURA DEL COPERCHIO RIPRISTINARE IL GRASSO
AL SILICONE ACCERTARSI CHE LE VALVOLE DI RESPIRAZIONE
E DRENAGGIO SIANO SEMPRE CHIUSE
RENEW SILICONE GREASE EVERY TIME COVER IS OPENED
AND MAKE SURE THAT THE DRAIN AND
BREATHER VALVES ARE ALWAYS CLOSED
11.10.93
Via M. Pagano, 3
I-20090Trezzano s/N
ITALY
www.feam-ex.com
II2 GD0722
CUSTODIA tipo
ENCLOSURE type
V Hz A
BKI 08 ATEX 019 Ta
W
Ex d IIB+H Ex tD A21 IP66T °C
NON APRIRE SOTTOTENSIONE
DO NOT OPENWHILE ENERGIZED
Ad ogni apertura del coperchio
ripristinare il grasso ai siliconi.
accertarsi che le valvole di respirazione
e drenaggio siano sempre chiuse
Renew silicone grease every tyme
cover is opened. and make sure
that the drain and breather valves
are always closed.
VA
11.00.88
S.r.l.
2 T
year s/n
Ex d IIC
Ex d IIB
A B C
14 - Feam Catalogue 03
CPSCP - FSQCP/BP - Typical assembling
Please refer to cpsc/fsqc bulletin for industrial application sockets and plugs colour marking
CODE A [mm]
TEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS (DUSTS)
WEIGHT
[Kg]
DETAIL
INTERLOCKED SOCKETS AND PLUGS
SOCKET TYPE POLES VOLTAGE (50/60Hz) CURRENT
INTERLOCKED SOCKETS AND PLUGS WITH ON-LOAD SWITCH
SOCKET TYPE POLES VOLTAGE (50/60Hz) CURRENT
INTERLOCKED SOCKETS AND PLUGS WITH CIRCUIT BREAKER
SOCKET TYPE POLES VOLTAGE (50/60Hz) CURRENT
125A INTERLOCKED SOCKETS AND PLUGS
SOCKET
TYPE
PLUG
TYPE
POLES
VOLTAGE
(50/60Hz)
CURRENT
14 - Feam Catalogue 03
Ex Interlocked sockets & plugs
CPSCP - FSQCP/BP - Technical Features
REMARK: Due to the development of the national and international specifications and of the technology, the above technical
characteristics showed on this bulletin can be considered as binding on our confirmation only.
*WITHOUT ENCLOSURE (TO BE ORDERED SEPARATELY)
YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
DXN
DXNInstallation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts)
Classification: Group II - Category 2G 2D
Ex interlocked sockets & plugs
Mechanical characteristics	
interlocked SOCKETS & PLUGS
Feam Catalogue 03 - 15
Material glass reinforced polyester resin, perfectly antistatic
Pin configuration in 24 hours, according to voltages (CEE 17)
Contacts "Head" nickel-silver braided wire for reliability and durability
Terminals insensitive to vibration and thermal shok
Cover-socket automatic opening
Impact resistance IK08
Internal Switch Interlocked type (EN 60309-1) AC23 category (IEC 947-3, EN 60947-3), AC22 category (CEI EN 60947-3)
SWITCH SOCKETS & PLUGS DXN1
ATEX 94/9/EC IECEx INMETRO GOST-R (RTR / RTN)
EXECUTION
II 2 G Ex de IIC T5 / T6
II 2 D Ex tD A21 T90°C/T70°C
Ex de IIC T5 / T6
Ex tD A21 T90°C / T70°C
Ex de IIC T5 / T6 Gb
Ex tD A21 T90°C / T70°C Db
2 Ex de IIC T5 / T6
DIP A21 T90°C / T70°C
AMBIENT TEMPERATURE
-40°C ÷ +60°C
-40°C ÷ +40°C
-40°C ÷ +60°C
-40°C ÷ +40°C
-40°C ÷ +60°C
-40°C ÷ +40°C
-40°C ÷ +40°C
PROTECTION DEGREE IP66/67 IP66/67 IP66/67 IP66/67
CERTIFICATE REF. LCIE 99 ATEX 6027X IECEx LCIE 09.0005X BVC 10.0026-X POCC FR. ГБ05.B03779
RULES OF COMPLIANCE
EN 60079-0; EN
60079-1; EN 60079-7;
EN 61241-0; EN 61241-1
EC 60079-0; IEC 60079-1;
IEC 60079-7;
IEC 61241-0; IEC 61241-1
ABNT NBR IEC 60079-0;
ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-7;
ABNT NBR IEC 60079-31;
ABNT NBR IEC 60529;
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004
SWITCH SOCKETS & PLUGS DXN3
ATEX 94/9/EC IECEx INMETRO GOST-R (RTR / RTN)
EXECUTION
II 2 G Ex de IIC T5 / T6
II 2 D Ex tD A21 T90°C / T70°C
Ex de IIC T5 / T6
Ex tD A21 T90°C / T70°C
Ex de IIC T5 / T6 Gb
Ex tD A21 T90°C / T70°C Db
2 Ex de IIC T5 / T6
DIP A21 T90°C / T70°C
AMBIENT TEMPERATURE
-40°C ÷ +60°C
-40°C ÷ +40°C
-40°C ÷ +60°C
-40°C ÷ +40°C
-40°C ÷ +60°C
-40°C ÷ +40°C
-40°C ÷ +40°C
PROTECTION DEGREE IP66/67 IP66/67 IP66/67 IP66/67
CERTIFICATE REF. LCIE 99 ATEX 6149X IECEx LCIE 09.0006 BVC 10.0024 POCC FR. ГБ05.B02573
RULES OF COMPLIANCE
EN 60079-0; EN
60079-1; EN 60079-7;
EN 61241-0; EN 61241-1
IEC 60079-0; IEC 60079-1;
IEC 60079-7;
IEC 61241-0; IEC 61241-1
ABNT NBR IEC 60079-0;
ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-7;
ABNT NBR IEC 60079-31;
ABNT NBR IEC 60529
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004
SWITCH SOCKETS & PLUGS DXN6
ATEX 94/9/EC IECEx INMETRO GOST-R (RTR / RTN)
EXECUTION
II 2 G Ex de IIC T4 / T6
II 2 D Ex tD A21 T107°C / T80°C
Ex de IIC T4 / T6
Ex tD A21 T107°C / T80°C
Ex de IIC T4 / T6 Gb
Ex tD A21 T107°C / T80°C Db
2 Ex de IIC T4 / T6
DIP A21 T107°C / T80°C
AMBIENT TEMPERATURE
-40°C ÷ +60°C
-40°C ÷ +40°C
-40°C ÷ +60°C
-40°C ÷ +40°C
-40°C ÷ +60°C
-40°C ÷ +40°C
-40°C ÷ +40°C
PROTECTION DEGREE IP66/67 IP66/67 IP66/67 IP66/67
CERTIFICATE REF. LCIE 99 ATEX 6150X IECEx LCIE 09.0007 BVC 10.0025 POCC FR. ГБ05.B02573
RULES OF COMPLIANCE
EN 60079-0; EN
60079-1; EN 60079-7;
EN 61241-0; EN 61241-1
IEC 60079-0; IEC 60079-1;
IEC 60079-7;
IEC 61241-0; IEC 61241-1
ABNT NBR IEC 60079-0;
ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-7;
ABNT NBR IEC 60079-31;
ABNT NBR IEC 60529
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004
YOUR PARTNER FOR SAFETY
Since 1961
DXN
G
F
C A
ØH
ØH
E
B
D
DXN1 130 130 36 77 56 62 150 M20 0,40
DXN3 145 160 70 70 70 70 155 M25 0,70
DXN6 159 150 77 88 77 81 213 M25 1,00
T70°C (Ta -40°C/+40°C)
T90°C (Ta-40°C/+60°C)
T78°C (Ta -40°C/+40°C)
T98°C (Ta-40°C/+60°C)
T87°C (Ta -40°C/+40°C)
T107°C (Ta-40°C/+60°C)
T6 (-40°C/+40°C)
T5 (-40°C/+60°C)
T6 (-40°C/+40°C)
T5 (-40°C/+60°C)
T6 (-40°C/+40°C)
T5 (-40°C/+60°C)
DXN1 2514082 2518082 2P + T (PE) 24V 20A 2,5
DXN1 2514132 2518132 2P + T (PE) 48V 20A 2,5
DXN1 2514035 2518035 2P + T (PE) 110/130V 20A 2,5
DXN1 2514015 2518015 2P + T (PE) 220/250V 20A 2,5
DXN1 2514013 2518013 3P + T (PE) 380/415V 20A 2,5
DXN1 2514017 2518017 3P + N + T (PE) 380/415V 20A 2,5
DXN3 2534013 2538013 3P + T (PE) 380/415V 32A 6
DXN3 2534017 2538017 3P + N + T (PE) 380/415V 32A 6
DXN3 2534093 2538093 3P + T (PE) 500V 32A 6
DXN3 2534097 2538097 3P + N + T (PE) 500V 32A 6
DXN6 2564013 2568013 3P + T (PE) 380/415V 63A 16
DXN6 2564017 2568017 3P + N + T (PE) 380/415V 63A 16
DXN6 2564093 2568093 3P + T (PE) 500V 63A 16
DXN6 2564097 2568097 3P + N + T (PE) 500V 63A 16
ØH
16 - Feam Catalogue 03
Ex Interlocked sockets & plugs
DXN Technical Features
*DIFFERENT VOLTAGE FROM STANDARD, PLEASE CONTACT OUR SALES DEPT.
CODE
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
CABLE
GLANDS
ØH
TEMPERATURE
CLASS (GAS)
TEMPERATURE
CLASS (DUSTS)
WEIGHT
[Kg]
INTERLOCKED RECEPTACLES AND PLUGS
TYPE SOCKET CODE PLUG CODE POLES VOLTAGE CURRENT TERMINALS [sqmm]
PLUG
SWITCH SOCKET
REMARK: Due to the development of the national and international specifications and of the technology, the above technical
characteristics showed on this bulletin can be considered as binding on our confirmation only.

More Related Content

What's hot

ASCO ATEX Solenoid Valves - 327 Series - Spec Sheet
ASCO ATEX Solenoid Valves - 327 Series - Spec SheetASCO ATEX Solenoid Valves - 327 Series - Spec Sheet
ASCO ATEX Solenoid Valves - 327 Series - Spec SheetThorne & Derrick UK
 
06 pinze di-terra-eng
06 pinze di-terra-eng06 pinze di-terra-eng
06 pinze di-terra-engHai Pham
 
Asco 8210 Series RedHat Solenoid Valve
Asco 8210 Series RedHat Solenoid ValveAsco 8210 Series RedHat Solenoid Valve
Asco 8210 Series RedHat Solenoid ValveCarotek
 
ASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry ApplicationsASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry ApplicationsThorne & Derrick UK
 
3 channel thermocouple thermometer
3 channel thermocouple thermometer3 channel thermocouple thermometer
3 channel thermocouple thermometerIsmanu Rahadi
 
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...Thorne & Derrick International
 
ROTEX Controls Industrial NEMA 4 and NEMA 7 Limit Switch Catalog
ROTEX Controls Industrial NEMA 4 and NEMA 7 Limit Switch CatalogROTEX Controls Industrial NEMA 4 and NEMA 7 Limit Switch Catalog
ROTEX Controls Industrial NEMA 4 and NEMA 7 Limit Switch CatalogROTEX Controls USA
 
Original P-Channel Mosfet APM4015P APM4015 4015 TO-252 New ANPEC
Original P-Channel Mosfet APM4015P APM4015 4015 TO-252 New ANPECOriginal P-Channel Mosfet APM4015P APM4015 4015 TO-252 New ANPEC
Original P-Channel Mosfet APM4015P APM4015 4015 TO-252 New ANPECAUTHELECTRONIC
 
Transistor mosfet to220 - psmn005
Transistor mosfet   to220 - psmn005Transistor mosfet   to220 - psmn005
Transistor mosfet to220 - psmn005Samuel Borges
 
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...Thorne & Derrick International
 
Hakko 936 schem-pcb_&_mod_v1r7
Hakko 936 schem-pcb_&_mod_v1r7Hakko 936 schem-pcb_&_mod_v1r7
Hakko 936 schem-pcb_&_mod_v1r7Iman Teguh Pribadi
 

What's hot (16)

ASCO ATEX Solenoid Valves - 327 Series - Spec Sheet
ASCO ATEX Solenoid Valves - 327 Series - Spec SheetASCO ATEX Solenoid Valves - 327 Series - Spec Sheet
ASCO ATEX Solenoid Valves - 327 Series - Spec Sheet
 
06 pinze di-terra-eng
06 pinze di-terra-eng06 pinze di-terra-eng
06 pinze di-terra-eng
 
Hakko 936 schematic
Hakko 936 schematicHakko 936 schematic
Hakko 936 schematic
 
Asco 8210 Series RedHat Solenoid Valve
Asco 8210 Series RedHat Solenoid ValveAsco 8210 Series RedHat Solenoid Valve
Asco 8210 Series RedHat Solenoid Valve
 
Brooks Ar-Mite Low Flow Armored Flowmeter
Brooks Ar-Mite Low Flow Armored FlowmeterBrooks Ar-Mite Low Flow Armored Flowmeter
Brooks Ar-Mite Low Flow Armored Flowmeter
 
ASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry ApplicationsASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry Applications
 
3 channel thermocouple thermometer
3 channel thermocouple thermometer3 channel thermocouple thermometer
3 channel thermocouple thermometer
 
Soldavac tsx70
Soldavac tsx70Soldavac tsx70
Soldavac tsx70
 
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...
 
ROTEX Controls Industrial NEMA 4 and NEMA 7 Limit Switch Catalog
ROTEX Controls Industrial NEMA 4 and NEMA 7 Limit Switch CatalogROTEX Controls Industrial NEMA 4 and NEMA 7 Limit Switch Catalog
ROTEX Controls Industrial NEMA 4 and NEMA 7 Limit Switch Catalog
 
Original P-Channel Mosfet APM4015P APM4015 4015 TO-252 New ANPEC
Original P-Channel Mosfet APM4015P APM4015 4015 TO-252 New ANPECOriginal P-Channel Mosfet APM4015P APM4015 4015 TO-252 New ANPEC
Original P-Channel Mosfet APM4015P APM4015 4015 TO-252 New ANPEC
 
Transistor mosfet to220 - psmn005
Transistor mosfet   to220 - psmn005Transistor mosfet   to220 - psmn005
Transistor mosfet to220 - psmn005
 
Heaters
HeatersHeaters
Heaters
 
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...
 
Tubeaxial-Mil-XTM
Tubeaxial-Mil-XTMTubeaxial-Mil-XTM
Tubeaxial-Mil-XTM
 
Hakko 936 schem-pcb_&_mod_v1r7
Hakko 936 schem-pcb_&_mod_v1r7Hakko 936 schem-pcb_&_mod_v1r7
Hakko 936 schem-pcb_&_mod_v1r7
 

Similar to 05 pulsantiere prese-spine-eng

05 multiple control stations
05 multiple control stations05 multiple control stations
05 multiple control stationsHai Pham
 
02 feam enclosures_eng
02 feam enclosures_eng02 feam enclosures_eng
02 feam enclosures_engHai Pham
 
03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_engHai Pham
 
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...Thorne & Derrick International
 
MEDC Manual Call Points & Break Glass Units for Hazardous Areas
MEDC Manual Call Points & Break Glass Units for Hazardous AreasMEDC Manual Call Points & Break Glass Units for Hazardous Areas
MEDC Manual Call Points & Break Glass Units for Hazardous AreasThorne & Derrick International
 
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2Thorne & Derrick International
 
Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...
Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...
Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...Thorne & Derrick International
 
MQ-BQ - FEAM ATEX & GOST-R Hazardous Area Axial Fan - Spec Sheet
MQ-BQ - FEAM ATEX & GOST-R Hazardous Area Axial Fan - Spec SheetMQ-BQ - FEAM ATEX & GOST-R Hazardous Area Axial Fan - Spec Sheet
MQ-BQ - FEAM ATEX & GOST-R Hazardous Area Axial Fan - Spec SheetThorne & Derrick UK
 
BOOST110.pdf
BOOST110.pdfBOOST110.pdf
BOOST110.pdftahar6
 
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...Thorne & Derrick International
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Thorne & Derrick International
 
Fuji thiet bi dien-elcbfuji-160413044256
Fuji thiet bi dien-elcbfuji-160413044256Fuji thiet bi dien-elcbfuji-160413044256
Fuji thiet bi dien-elcbfuji-160413044256Thuan Kieu
 
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.org
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.orgFuji thiet bi dien-elcbfuji-160413044256 dienhathe.org
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.orgDien Ha The
 
Air Circuit Breakers BT3 Series - Fuji Electric
Air Circuit Breakers BT3 Series - Fuji ElectricAir Circuit Breakers BT3 Series - Fuji Electric
Air Circuit Breakers BT3 Series - Fuji ElectricCTY TNHH HẠO PHƯƠNG
 
Catalogue ELCB Fuji - Earth Leakage Circuit Breaker Fuji - Beeteco.com
 Catalogue ELCB Fuji - Earth Leakage Circuit Breaker  Fuji - Beeteco.com Catalogue ELCB Fuji - Earth Leakage Circuit Breaker  Fuji - Beeteco.com
Catalogue ELCB Fuji - Earth Leakage Circuit Breaker Fuji - Beeteco.comBeeteco
 
Asco li wsli atex-iec ex intrinsically safe operator hazardous area solenoid ...
Asco li wsli atex-iec ex intrinsically safe operator hazardous area solenoid ...Asco li wsli atex-iec ex intrinsically safe operator hazardous area solenoid ...
Asco li wsli atex-iec ex intrinsically safe operator hazardous area solenoid ...Thorne & Derrick UK
 

Similar to 05 pulsantiere prese-spine-eng (20)

05 multiple control stations
05 multiple control stations05 multiple control stations
05 multiple control stations
 
02 feam enclosures_eng
02 feam enclosures_eng02 feam enclosures_eng
02 feam enclosures_eng
 
03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng
 
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...
Stahl Inspection Light LED Series 6149/2 - Hazardous Area Lighting For Zone 1...
 
MEDC Manual Call Points & Break Glass Units for Hazardous Areas
MEDC Manual Call Points & Break Glass Units for Hazardous AreasMEDC Manual Call Points & Break Glass Units for Hazardous Areas
MEDC Manual Call Points & Break Glass Units for Hazardous Areas
 
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2
Walsall - Hazardous Area ATEX Control Stations Zone 1 & Zone 2
 
R gz7 v1-databook
R gz7 v1-databookR gz7 v1-databook
R gz7 v1-databook
 
Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...
Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...
Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...
 
MQ-BQ - FEAM ATEX & GOST-R Hazardous Area Axial Fan - Spec Sheet
MQ-BQ - FEAM ATEX & GOST-R Hazardous Area Axial Fan - Spec SheetMQ-BQ - FEAM ATEX & GOST-R Hazardous Area Axial Fan - Spec Sheet
MQ-BQ - FEAM ATEX & GOST-R Hazardous Area Axial Fan - Spec Sheet
 
BOOST110.pdf
BOOST110.pdfBOOST110.pdf
BOOST110.pdf
 
Control Stations - Hazardous Area - Technor EFE
Control Stations - Hazardous Area - Technor EFEControl Stations - Hazardous Area - Technor EFE
Control Stations - Hazardous Area - Technor EFE
 
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
 
MCCB Easy Pact ECLB
MCCB Easy Pact ECLBMCCB Easy Pact ECLB
MCCB Easy Pact ECLB
 
Fuji thiet bi dien-elcbfuji-160413044256
Fuji thiet bi dien-elcbfuji-160413044256Fuji thiet bi dien-elcbfuji-160413044256
Fuji thiet bi dien-elcbfuji-160413044256
 
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.org
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.orgFuji thiet bi dien-elcbfuji-160413044256 dienhathe.org
Fuji thiet bi dien-elcbfuji-160413044256 dienhathe.org
 
Air Circuit Breakers BT3 Series - Fuji Electric
Air Circuit Breakers BT3 Series - Fuji ElectricAir Circuit Breakers BT3 Series - Fuji Electric
Air Circuit Breakers BT3 Series - Fuji Electric
 
Catalogue ELCB Fuji - Earth Leakage Circuit Breaker Fuji - Beeteco.com
 Catalogue ELCB Fuji - Earth Leakage Circuit Breaker  Fuji - Beeteco.com Catalogue ELCB Fuji - Earth Leakage Circuit Breaker  Fuji - Beeteco.com
Catalogue ELCB Fuji - Earth Leakage Circuit Breaker Fuji - Beeteco.com
 
Asco li wsli atex-iec ex intrinsically safe operator hazardous area solenoid ...
Asco li wsli atex-iec ex intrinsically safe operator hazardous area solenoid ...Asco li wsli atex-iec ex intrinsically safe operator hazardous area solenoid ...
Asco li wsli atex-iec ex intrinsically safe operator hazardous area solenoid ...
 
Abtech SX Stainless Steel And Mild Steel Enclosures
Abtech SX Stainless Steel And Mild Steel EnclosuresAbtech SX Stainless Steel And Mild Steel Enclosures
Abtech SX Stainless Steel And Mild Steel Enclosures
 

More from Hai Pham

01 feam lighting_eng
01 feam lighting_eng01 feam lighting_eng
01 feam lighting_engHai Pham
 
System accessories
System accessoriesSystem accessories
System accessoriesHai Pham
 
Cm compact medium
Cm   compact mediumCm   compact medium
Cm compact mediumHai Pham
 
New dk ps rack brochure (final)
New dk ps rack brochure (final)New dk ps rack brochure (final)
New dk ps rack brochure (final)Hai Pham
 
Catalogue 34
Catalogue 34Catalogue 34
Catalogue 34Hai Pham
 

More from Hai Pham (7)

01 feam lighting_eng
01 feam lighting_eng01 feam lighting_eng
01 feam lighting_eng
 
Nb cat
Nb catNb cat
Nb cat
 
System accessories
System accessoriesSystem accessories
System accessories
 
Cm compact medium
Cm   compact mediumCm   compact medium
Cm compact medium
 
Ps smart
Ps smartPs smart
Ps smart
 
New dk ps rack brochure (final)
New dk ps rack brochure (final)New dk ps rack brochure (final)
New dk ps rack brochure (final)
 
Catalogue 34
Catalogue 34Catalogue 34
Catalogue 34
 

05 pulsantiere prese-spine-eng

  • 1. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment EFG EFG Feam Catalogue 03 - 1 EX Control Stations MULTIPLE CONTROL STATIONS On request accessories: •External epoxy painting with colour on request •Cable entries with different threads from standards Mechanical characteristics Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless steel Internal plate hot dip galvanized steel Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D MULTIPLE CONTROL STATIONS ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K EXECUTION II 2 G Ex d IIB T5/T6 Gb II 2 D Ex tb IIIC T85°C/T100°C Db Ex d IIB T5/T6 Gb Ex tb IIIC T85°C/T100°C Db Ex d IIB T5/T6 Gb Ex tb IIIC T85°C/T100°C Db Ex d IIB T5 (T6) Gb Ex tb IIIC T85°C (T100°C) Db Ex d IIB T5 (T6) Gb Ex tb IIIC T85°C (T100°C) Db AMBIENT TEMPERATURE -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66 CERTIFICATE REF. INERIS 03 ATEX 0047 IECEx INE 11.0034X - POCC IT. ME92.B02924 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-31 IEC 60079-0; IEC 60079-1; IEC 60079-31 ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ГОСТ Р 51330.0/1/8/14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 2. YOUR PARTNER FOR SAFETY Since 1961 EFG EFG6/ EFG6-A EFG6 195 130 100 155 160 104 GK 1" 150 - 95 3,20 A EFG6-A 195 130 125 175 160 104 GK 1” 150 - 95 3,50 A F ØG B C D E A A EFG6 EFG6 EFG6 SCHEMA - "A" SCHEMA - "B" SCHEMA - "C"SCHEMA - "A1" EFG6 TERMINALS SCHEMA - "B1" EFG6 TERMINALS EFG6 EFG10 1-2 1-2 1-2 1-23 3 3 2 - Feam Catalogue 03 EX Control Stations EFG Technical Features REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. EFG Max. operators allowed diagrams LEGEND: 1 EFP Push Button 2 EFL Pilot Light 3 EFI Handle Switch MORE OPERATORS DETAILS ARE AVAILABLE ON “HANDLES-D” BULLETIN REMARK - (A) twin holes 1-2 type, can be replaced by one hole 3 type DIAGRAM “A” DIAGRAM “A1” DIAGRAM “B” DIAGRAM “B1” DIAGRAM “C” CODE A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] INTERNAL PLATE [mm] WEIGHT [Kg] DETAIL Reference details
  • 3. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment EFSC218 EFSC218 Feam Catalogue 03 - 3 Ex Control station On request accessories: •External epoxy painting with colour on request •Cable entries with different threads from standard Mechanical characteristics Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless steel Internal plate hot dip galvanized steel Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D THERMAL MAGNETIC AND EARTH LEAKAGE CIRCUIT BREAKERS, SELECTOR AND FUSED SWITCHES CIRCUIT BREAKERS AND SWITCHES ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K EXECUTION II 2 G Ex d IIB T5/T6 Gb II 2 D Ex tb IIIC T85°C/T100°C Db Ex d IIB T5/T6 Gb Ex tb IIIC T85°C/T100°C Db Ex d IIB T5/T6 Gb Ex tb IIIC T85°C/T100°C Db Ex d IIB T5 (T6) Gb Ex tb IIIC T85°C (T100°C) Db Ex d IIB T5 (T6) Gb Ex tb IIIC T85°C (T100°C) Db AMBIENT TEMPERATURE -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66 CERTIFICATE REF. INERIS 03 ATEX 0047 IECEx INE 11.0034X - POCC IT. ME92.B02925 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-31 IEC 60079-0; IEC 60079-1; IEC 60079-31 ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ГОСТ Р 51330.0/1/8/14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 4. YOUR PARTNER FOR SAFETY Since 1961 EFSC218 EFSC218GUSV3225 EFSC218GUSV3425 25A D EFSC218GUSV3240 EFSC218GUSV3440 40A D - EFSC218GUSV3463 63A D EFSC218M310 - 2 10A A EFSC218M310L 1 1 10A A FIGURA A FIGURA C FIGURA E ØF ØF C E D A B EFSC2183I3V16 1 2 16A B EFSC2183I3V25 1 1 25A B FIGURA A FIGURA B FIGURA C FIGURA D FIGURA E ØF ØF C E D A B EFSC218GUSC3206 EFSC218GUSC3306 EFSC218GUSC3406 6A C EFSC218GUSC3210 EFSC218GUSC3310 EFSC218GUSC3410 10A C EFSC218GUSC3216 EFSC218GUSC3316 EFSC218GUSC3416 16A C EFSC218GUSC3220 EFSC218GUSC3320 EFSC218GUSC3420 20A C EFSC218GUSC3225 EFSC218GUSC3325 EFSC218GUSC3425 25A C EFSC218GUSC3232 EFSC218GUSC3332 EFSC218GUSC3432 32A C EFSC218GUSC3240 EFSC218GUSC3340 EFSC218GUSC3440 40A C EFSC218GUSC3250 EFSC218GUSC3350 EFSC218GUSC3450 50A C EFSC218GUSC3263 EFSC218GUSC3363 EFSC218GUSC3463 63A C FIGURA A FIGURA C FIGURA E ØF ØF C E D A B FIGURA A FIGURA B FIGURA C FIGURA D FIGURA E ØF ØF C E D A B EFSC218SMT034 0,20 - 0,35A E EFSC218SMT036 0,35 - 0,60A E EFSC218SMT301 0,60 - 1,00A E EFSC218SMT302 1,00 - 1,60A E EFSC218SMT303 1,60 - 2,50A E EFSC218SMT304 2,50 - 4,00A E EFSC218SMT306 4,00 - 6,60A E EFSC218SMT310 6,00 - 10,00A E EFSC218SMT316 10,00 - 16,00A E FIGURA A FIGURA C FIGURA E ØF ØF C E D A B EFSC218 M310 195 185 130 118 145 GK 1” T5 T100°C EFSC218M310L T4 T125°C 3,45 A EFSC218 3I3V25 195 185 130 118 145 GK 1” T5 T100°C EFSC218313V26 T4 T125°C 3,10 B EFSC218 GUSC… 195 185 130 118 155 GK 1” T5 T100°C T4 T125°C 3,10 C EFSC218 GUSV… 195 185 130 118 145 GK 1” T5 T100°C T4 T125°C 3,20 D EFSC218 SMT… 195 185 130 118 130 GK 1” T5 T100°C T4 T125°C 2,90 E D A B C E 4 - Feam Catalogue 03 Ex Control station EFSC218 Technical Features EARTH LEAKAGE CIRCUIT BREAKERS 400/230V 50-60Hz 300mA 1PH+N - 3PH+N TWO POLES THREE POLES RATE [In] DETAIL SELECTOR SWITCHES 500V 50-60Hz TYPE SELECTOR SWITCHES Q.TY RATE [In] DETAIL PADLOCK HANDLE NORMAL HANDLE THREE POLES FUSE SWITCH 500V 50-60Hz TYPE THREE POLE SWITCH E16 DELAYED FUSE RATE [In] DETAIL CIRCUIT BREACKERS CURVE “C” 415V 50-60Hz 6kA TWO POLES THREE POLES FOUR POLES RATE [In] DETAIL THERMAL MAGNETIC MOTOR PROTECTION THREE POLES 660V 50-60Hz TYPE RANGE DETAIL REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. CODE A [mm] B [mm] C [mm] D [mm] E [mm] ØF [mm] TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) WEIGHT [Kg] DETAIL
  • 5. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment EFDC EFDC EFDC3 EFDC1E EFDC1 EFDC1EF EFDC12R Feam Catalogue 03 - 5 Ex Control station On request accessories: •External epoxy painting with colour on request •Different threads from standard Mechanical characteristics Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless steel Gasket NBR rubber sealing ring PUSH BUTTONS AND CONTROL STATIONS Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D PUSH BUTTONS AND CONTROL STATIONS ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K EXECUTION II 2 G Ex d IIC T5/T6 Gb II 2 D Ex tb IIIC T85°C/T100°C Db Ex d IIC T5/T6 Gb Ex tb IIIC T85°C/T100°C Db Ex d IIC T5/T6 Gb Ex tb IIIC T85°C/T100°C Db Ex d IIC T5 (T6) Gb Ex tb IIIC T85°C (T100°C) Db Ex d IIC T5 (T6) Gb Ex tb IIIC T85°C (T100°C) Db AMBIENT TEMPERATURE -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66 CERTIFICATE REF. INERIS 04 ATEX 0076X IECEx INE 11.0033X - POCC IT. ME92.B02925 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-31 IEC 60079-0; IEC 60079-1; IEC 60079-31 ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ГОСТ Р 51330.0/1/8/14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 6. YOUR PARTNER FOR SAFETY Since 1961 EFDC EFDC1 A EFDC2 A EFDC1E (*) C EFDC1EF (**) F EFDC1EFSR E EFDC3R B EFDC3V B EFDC111R B EFDC121R D EFDC122R D EFDC123R D EFDC222R D EFDC13R D EFDC23R D EFDC133R D EFDC233R D EFDC33R D EFDC333R D C FIG. A SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO DON TENSIONE SOTTO DON TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE FIG. B FIG. DFIG. C FIG. E FIG. F A B ØED ØE FIG. A SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO DON TENSIONE SOTTO DON TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE FIG. B FIG. DFIG. C FIG. E FIG. F A C B ØED ØE FIG. A SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE FIG. C FIG. E A C B ØED ØE EFDC1/2 120 115 95 55 GK 3/4” T6 T85°C T5 T100°C 0,90 A EFDC3 120 120 95 5 GK 3/4” T6 T85°C T5 T100°C 0,90 B EFDC1E 120 135 95 55 GK 3/4” T6 T85°C T5 T100°C 1,00 C EFDC…R 140 125 100 80 GK 1” T6 T85°C T5 T100°C 1,50 D EFDC1EFSR 120 160 95 55 GK 3/4” T6 T85°C T5 T100°C 0,90 E EFDC1EF 120 130 95 55 GK 3/4” T6 T85°C T5 T100°C 0,90 F SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE FIG. B FIG. D FIG. F A B ØED ØE C C FIG. A SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE FIG. B FIG. DFIG. C FIG. E FIG. F A B ØED ØE FIG. A SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE FIG. B FIG. DFIG. C FIG. E FIG. F A B ØED ØE C A B C ED F 6 - Feam Catalogue 03 Ex Control station EFDC Technical Features EFDC Standard operators layout REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. * WITH BREAKING GLASS (EMERGENCY STOP) ** WITH RED MUSHROOM EMERGENCY PUSH BUTTON OPERATORS TYPE OPERATORS LAYOUT (QUANTITY) PUSH BUTTON NO (1) 1 1 2 1 1 3 PUSH BUTTON NC (2) 1 1 1 - - - PILOT LIGHT (3) 1 - - 2 1 - EXAMPLES: EFDC123R EFDC12R EFDC112R EFDC133R EFDC13R EFDC111R CODE DETAIL CODE DETAIL CODE DETAIL CODE A [mm] B [mm] C [mm] D [mm] E [mm] TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) WEIGHT [Kg] DETAIL
  • 7. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment EFSC EFSC EFSC2... EFSC3... EFSC5... Feam Catalogue 03 - 7 Ex Control station On request accessories: •External epoxy painting with colour on request •Different threads from standard Mechanical characteristics Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless steel Gasket NBR rubber sealing ring ROTARY SWITCHES AND SELECTOR SWITCHES Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D MOTOR CONTROL SWITCHES - ROTARY SWITCHES - SELECTOR SWITCHES ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K EXECUTION II 2 G Ex d IIC T5/T6 Gb II 2 D Ex tb IIIC T85°C/T100°C Db Ex d IIC T5/T6 Gb Ex tb IIIC T85°C/T100°C Db Ex d IIC T5/T6 Gb Ex tb IIIC T85°C/T100°C Db Ex d IIC T5 (T6) Gb Ex tb IIIC T85°C (T100°C) Db Ex d IIC T5 (T6) Gb Ex tb IIIC T85°C (T100°C) Db AMBIENT TEMPERATURE -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66 CERTIFICATE REF. INERIS 04 ATEX 0076X IECEx INE 11.0033X - POCC IT. ME92.B02925 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-31 IEC 60079-0; IEC 60079-1; IEC 60079-31 ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ГОСТ Р 51330.0/1/8/14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 8. YOUR PARTNER FOR SAFETY Since 1961 EFSC EFSC21 EFSC22 EFSC23 - 16A A EFSC3125 EFSC3225 EFSC3325 EFSC3425 25A B EFSC5125 EFSC5225 EFSC5325 EFSC5425 25A C EFSC3132 EFSC3232 EFSC3332 EFSC3432 32A B EFSC5132 EFSC5232 EFSC5332 EFSC5432 32A C EFSC21D EFSC22D - - 16A A EFSC3125D EFSC3225D EFSC3325D (1) 25A B EFSC5125D EFSC5225D EFSC5325D (1) 25A C EFSC3132D EFSC3232D EFSC3332D (1) 32A B EFSC5132D EFSC5232D EFSC5332D (1) 32A C EFSC21C EFSC22C - - 16A A EFSC3125C EFSC3225C EFSC3325C (1) 25A B EFSC5125C EFSC5225C EFSC5325C (1) 25A C EFSC3132C EFSC3232C EFSC3332C (1) 32A B EFSC5132C EFSC5232C EFSC5332C (1) 32A C EFSC310R 10A EFSC316R 16A R B EFSC310X 10A EFSC316X 16A X B EFSC310Y 10A EFSC316Y 16A Y B EFSC310W 10A EFSC316W 16A W B EFSC310Z 10A EFSC316Z 16A Z B EFSC510R 10A EFSC516R 16A R C EFSC510X 10A EFSC516X 16A X C EFSC510Y 10A EFSC516Y 16A Y C EFSC510W 10A EFSC516W 16A W C EFSC510Z 10A EFSC516Z 16A Z C EFSC2… 120 135 95 55 GK 3/4” T6 T85°C T5 T100°C 0,90 A EFSC3… 140 150 100 80 GK 1” T6 T85°C T5 T100°C 1,00 B EFSC5… 165 170 150 115 - T6 T85°C T5 T100°C 1,80 C OFF 10.88.32 SOTTO ENERGIZED NONAPRIRE WHILE OPEN DONOT TENSIONE OFF 10.88.32 FIG. A FIG A C B ØED ØE OFF 10.88.32 SO TT O ENERGIZED NONAPRIRE WHILE OPEN DO NO T TENSION E OFF 10.88.32 FIG. B OFF 10.88.32 FIG. A FIG. C A C B D OFF 10.88.32 SO TTO ENERGIZED NONAPRIRE WHILE OPEN DO NO T TENSIONE OFF 10.88.32 FIG. B OFF 10.88.32 FIG. A FIG. C A C B ØED ØE M O A-B 1 4 2 3 5 8 6 7 M O A-B 1 4 2 3 5 8 6 7 M O F-B 1 4 2 3 5 8 6 7 O A M O-B A 1 4 2 3 AU AM 1 4 2 3 TIPO "R" TIPO "X" TIPO "Y" TIPO "W" TIPO "Z" M O A-B 1 4 2 3 5 8 6 7 M O A-B 1 4 2 3 5 8 6 7 M O F-B 1 4 2 3 5 8 6 7 O A M O-B A 1 4 2 3 AU AM 1 4 2 3 TIPO "R" TIPO "X" TIPO "Y" TIPO "W" TIPO "Z" M O A-B 1 4 2 3 5 8 6 7 M O A-B 1 4 2 3 5 8 6 7 M O F-B 1 4 2 3 5 8 6 7 O A M O-B A 1 4 2 3 AU AM 1 4 2 3 TIPO "R" TIPO "X" TIPO "Y" TIPO "W" TIPO "Z" M O A-B 1 4 2 3 5 8 6 7 M O A-B 1 4 2 3 5 8 6 7 M O F-B 1 4 2 3 5 8 6 7 O A M O-B A 1 4 2 3 AU AM 1 4 2 3 TIPO "R" TIPO "X" TIPO "Y" TIPO "W" TIPO "Z" M O A-B 1 4 2 3 5 8 6 7 M O A-B 1 4 2 3 5 8 6 7 M O F-B 1 4 2 3 5 8 6 7 O A M O-B A 1 4 2 3 AU AM 1 4 2 3 TIPO "R" TIPO "X" TIPO "Y" TIPO "W" TIPO "Z" A C B 8 - Feam Catalogue 03 TYPE “R” Contactor control with mantained OFF position TYPE “X” Contactor control TYPE “Y” Reverse motor starter control TYPE “W” Impulse control TYPE “Z” MAN. AUT. control Ex Control station EFSC Technical Features REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. ON/OFF SWITCHES 500V 50/60Hz RATE [In] DETAIL 1 POLE 2 POLES 3 POLES 4 POLES TWO WAY SWITCHES 500V 50/60Hz RATE [In] DETAIL 1 POLE 2 POLES 3 POLES 4 POLES CHANGE OVER SWITCHES 500V 50/60Hz RATE [In] DETAIL 1 POLE 2 POLES 3 POLES 4 POLES SELECTOR SWITCHES 500V 50/60Hz DIAGRAM DETAIL TYPE RATE [In] TYPE RATE [In] CODE A [mm] B [mm] C [mm] D [mm] ØE [mm] TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) WEIGHT [Kg] DETAIL EFSC Motor switch diagram arrangements *DIAGRAM ARRANGEMENTS DIFFERENT THAN STANDARD, PLEASE CONTACT OUR SALES DEPT. (1): On request only (1): On request only
  • 9. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment EF…3D–EF…3T EF…3D – EF…3T EFDC3D EFDC3T Feam Catalogue 03 - 9 Ex Control Stations On request accessories: •External epoxy painting with colour on request •Cable entries with different thread from standard Mechanical characteristics Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless steel Gasket NBR rubber sealing ring MULTIPLE CONTROL STATIONS Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D MULTIPLE CONTROL STATIONS - ROTARY SWITCHES - SELECTOR SWITCHES ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K EXECUTION II 2 G Ex d IIC T5/T6 Gb II 2 D Ex tb IIIC T85°C/T100°C Db Ex d IIC T5/T6 Gb Ex tb IIIC T85°C/T100°C Db Ex d IIC T5/T6 Gb Ex tb IIIC T85°C/T100°C Db Ex d IIC T5 (T6) Gb Ex tb IIIC T85°C (T100°C) Db Ex d IIC T5 (T6) Gb Ex tb IIIC T85°C (T100°C) Db AMBIENT TEMPERATURE -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C -60°C ÷ +60°C PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66 CERTIFICATE REF. INERIS 04 ATEX 0076X IECEx INE 11.0033X - POCC IT. ME92.B02925 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-31 IEC 60079-0; IEC 60079-1; IEC 60079-31 ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ГОСТ Р 51330.0/1/8/14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 10. YOUR PARTNER FOR SAFETY Since 1961 EF…3D–EF…3T ØE C D B A F G / G.1* ØE D B A F G.1* G EF…3D 145 295 147,5 120 9 1" NPT 145 125 T6 T5 T85°C T100°C A EF…3T 145 425 130 120 9 1" NPT 145 125 T6 T5 T85°C T100°C B A A B B 10 - Feam Catalogue 03 Ex Control Stations EF…3D – EF…3T - Technical Features REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. 1 MUSHROOM PUSH BUTTON 1 SWITCH 1 INSTRUMENT (low lid) 1 PILOT LIGHT 1 CHANGE OVER SWITCH 1 PUSH BUTTON NO 1 PUSH BUTTON NC OPERATOR ARRANGEMENT: ON EACH COVER IS POSSIBLE TO FIT THE FOLLOWING MATERIAL: • 1 48x48 INSTRUMENT (low lid with glass) • UP TO 3 PILOT LIGHTS (as EFDC…R, see bulletin 65) • UP TO 3 PUSH BUTTON (as EFDC…R, see bulletin 65) • 1 MUSHROOM PUSH BUTTON (as EFDC…, see bulletin 65) • 1 SELECTOR SWITCH (as EFSC…, see bulletin 66) *LOW LID, ONLY FOR GLASS WINDOW EF…3D – EF…3T - installation examples Reference details CODE A [mm] B [mm] C [mm] D [mm] Ø E [mm] F [mm] G [mm] G.1 [mm] TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) DETAIL
  • 11. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment CPSC/CPH–FSQCA-FSQC/BPA CPSC / CPH FSQCA-FSQC / BPA fsqca/fsqc CPSC/CPH fsqc125/BP Feam Catalogue 03 - 11 Ex Interlocked sockets & plugs On request accessories: •External epoxy painting with colour on request •Cable entries with different thread from standard Mechanical characteristics Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless steel Pins brass INTERLOCKED SWITCH SOCKETS & PLUGS Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D Certified Nema Type 4X SWITCH SOCKETS & PLUGS ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K EXECUTION II 2 G Ex d IIC T6 II 2 D Ex tD A21 T85°C Ex d IIC T6 Ex tD A21 T85°C Ex d IIC T6 Ex tD A21 T85°C 1 Ex d IIC T6 DIP A21 TA 85°C 1 Ex d IIC T6 DIP A21 TA 85°C installation ZONE 1 / 2 - ZONE 21 / 22 PROTEC. DEGREE IP66/67 IP66/67 IP66/67 IP66/67 IP66/67 CERTIFICATE REF. IMQ 08 ATEX 016 - - POCC IT. ME92.B02925 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0 : 2006; EN 60079-1 : 2004; EN 61241-0 : 2006; EN 61242-1 : 2004 IEC 60079-0; IEC 60079-1; IEC 60079-31 ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ГОСТ Р 51330.0/1/8/14-99 ГОСТ Р МЭК 61241-1-1-2002 SWITCH SOCKETS & PLUGS (125A RAT. ONLY) ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K EXECUTION II 2 G Ex d IIC T6 II 2 D Ex tD A21 T85°C Ex d IIC T6 Ex tD A21 T85°C Ex d IIC T6 Ex tD A21 T85°C 1 Ex d IIC T6 DIP A21 TA 85°C 1 Ex d IIC T6 DIP A21 TA 85°C installation ZONE 1 / 2 - ZONE 21 / 22 PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66 CERTIFICATE REF. IMQ 09 ATEX 015 - - POCC IT. ME92.B02925 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0 : 2006; EN 60079-1 : 2004; EN 61241-0 : 2006; EN 61242-1 : 2004 IEC 60079-0; IEC 60079-1; IEC 60079-31 ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ГОСТ Р 51330.0/1/8/14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 12. YOUR PARTNER FOR SAFETY Since 1961 CPSC/CPH–FSQCA-FSQC/BPA E ØF ØF ØG D HxL B A ØC E ØF ØF ØG D HxL B A ØC E ØF GxH D ØC A B CPSC / CPH 195 370 113 155 140 3/4" NPT 1" NPT 92-90 T6 T85°C 2,80 A FSQC / BPA 230 415 155 200 163 1" NPT 1"NPT 125-80 T6 T85°C 4,00 B FSQC125 / BP125 380 615 275 305 225 - 1-1/2" NPT 308x270 T6 T85°C 15,5 C CPSC224-25A CPH224-25A 2P+T (PE) 24V 16A-25A CPSC248-25A CPH248-25A 2P+T (PE) 48V 16A-25A CPSC211-25A CPH211-25A 2P+T (PE) 110/130V 16A-25A CPSC222-25A CPH222-25A 2P+T (PE) 220/250V 16A-25A CPSC338-25A CPH338-25A 3P+T (PE) 380/415V 16A-25A CPSC3381-25A CPH3381-25A 3P+T (PE) 480/500V 16A-25A CPSC438-25A CPH438-25A 3P+N+T (PE) 380/415V 16A-25A CPSC4381-25A CPH4381-25A 3P+N+T (PE) 480/500V 16A-25A FSQC235 BPA235 2P+T (PE) 220/250V 32A FSQC335 BPA335 3P+T (PE) 380/415V 32A FSQC3351 BPA3351 3P+T (PE) 480/500V 32A FSQC435 BPA435 3P+N+T (PE) 380/415V 32A FSQC4351 BPA4351 3P+N+T (PE) 480/500V 32A FSQC260 BPA260 2P+T (PE) 220/250V 63A FSQC360 BPA360 3P+T (PE) 380/415V 63A FSQC3601 BPA3601 3P+T (PE) 480/500V 63A FSQC460 BPA460 3P+N+T (PE) 380/415V 63A FSQC4601 BPA4601 3P+N+T (PE) 480/500V 63A FSQCA235 BPA235 2P+T (PE) 220/250V 32A FSQCA335 BPA335 3P+T (PE) 380/400V 32A FSQCA260 BPA260 2P+T (PE) 220/250V 63A FSQCA360 BPA360 3P+T (PE) 380/400V 63A FSQC125-3 BP125-3 3P+T (PE) 380/415V 125A FSQC125-31 BP125-31 3P+T (PE) 480/500V 125A FSQC125-4 BP125-4 4P+T (PE) 380/415V 125A FSQC125-41 BP125-41 4P+T (PE) 480/500V 125A 20-25V 40-50V 100-130V 200-250V 380-480V 480-500V A B C 12 - Feam Catalogue 03 Ex Interlocked sockets & plugs CPSC/FSQC - Technical Features INTERLOCKED SOCKET AND PLUGS SOCKET TYPE PLUG TYPE POLES VOLTAGE (50/60Hz) CURRENT INTERLOCKED SOCKETS AND PLUGS WITH ON-LOAD SWITCH SOCKET TYPE PLUG TYPE POLES VOLTAGE (50/60Hz) CURRENT INTERLOCKED SOCKETS AND PLUGS WITH CIRCUIT BREAKER SOCKET TYPE PLUG TYPE POLES VOLTAGE (50/60Hz) CURRENT 125A INTERLOCKED SOCKETS AND PLUGS SOCKET TYPE PLUG TYPE POLES VOLTAGE (50/60Hz) CURRENT REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. Sockets and plugs colour marking for industrial applications NOMINAL WORKING VOLTAGE COLOUR 20-25V violet 40-50V WHITE 100-130V YELLOW 200-250V BLUE 380-480V RED 480-500V BLACK CODE A [mm] B [mm] C [mm] D [mm] E [mm] Ø F [mm] Ø G [mm] FIXING HxI [mm] TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) WEIGHT [Kg] DETAIL
  • 13. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment CPSCP–FSQCP/BP CPSCP - FSQCP / BP Feam Catalogue 03 - 13 Ex Interlocked sockets & plugs On request accessories: •External epoxy painting with colour on request •Cable entries with different thread from standard INTELOCKED PANEL SWITCH SOCKETS & PLUGS Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D Mechanical characteristics Body marine grade copper free aluminium light alloy Cover marine grade copper free aluminium light alloy Screws stainless steel Pins brass INTELOCKED PANEL SWITCH SOCKETS & PLUGS ATEX 94/9/EC IEC Ex INMETRO GOST-R (RTR/RTN) GOST-K EXECUTION II 2 G Ex d IIC T6 II 2 D Ex tD A21 T85°C Ex d IIC T6 Ex tD A21 T85°C Ex d IIC T6 Ex tD A21 T85°C 1 Ex d IIC T6 DIP A21 TA 85°C 1 Ex d IIC T6 DIP A21 TA 85°C INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 PROTEC. DEGREE IP66 IP66 IP66 IP66 IP66 CERTIFICATE REF. IMQ 08 ATEX 015 - - POCC IT. ME92.B02925 No. 07/43-269 RULES OF COMPLIANCE EN 60079-0 : 2006; EN 60079-1 : 2004; EN 61241-0 : 2006; EN 61242-1 : 2004 IEC 60079-0; IEC 60079-1; IEC 60079-31 ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 ГОСТ Р 51330.0/1/8/14-99 ГОСТ Р МЭК 61241-1-1-2002
  • 14. YOUR PARTNER FOR SAFETY Since 1961 CPSCP–FSQCP/BP CPSCP*/CPH 243 T6 T85°C 1,50 A FSQCP*/BP 255 T6 T85°C 2,00 B FSQCP125*/BP125 310 T6 T85°C 5,00 C CPSCP224 2P+T (PE) 24V 16A CPSCP224-25A 2P+T (PE) 24V 25A CPSCP248 2P+T (PE) 48V 16A CPSCP248-25A 2P+T (PE) 48V 25A CPSCP211 2P+T (PE) 110/130V 16A CPSCP211-25A 2P+T (PE) 110/130V 25A CPSCP222 2P+T (PE) 220/250V 16A CPSCP222-25A 2P+T (PE) 220/250V 25A CPSCP338 2P+T (PE) 380/415V 16A CPSCP338 2P+T (PE) 480/500V 16A CPSCP338-25A 3P+T (PE) 380/415V 25A CPSCP3381-25A 3P+T (PE) 480/500V 25A CPSCP438-25A 3P+N+T (PE) 380/415V 25A CPSCP4381-25A 3P+N+T (PE) 480/500V 25A FSQCP235 2P+T (PE) 220/250V 32A FSQCP335 3P+T (PE) 380/415V 32A FSQCP3351 3P+T (PE) 480/500V 32A FSQCP435 4P+T (PE) 380/415V 32A FSQCP4351 4P+T (PE) 480/500V 32A FSQCP260 2P+T (PE) 220/250V 63A FSQCP360 3P+T (PE) 380/415V 63A FSQCP3601 3P+T (PE) 480/500V 63A FSQCP460 4P+T (PE) 380/415V 63A FSQCP4601 4P+T (PE) 480/500V 63A FSQCAP235 2P+T (PE) 220/250V 32A FSQCAP335 3P+T (PE) 380/415V 32A FSQCAP435 4P+T (PE) 380/415V 32A FSQCAP260 2P+T (PE) 220/250V 63A FSQCAP360 3P+T (PE) 380/415V 63A FSQCAP460 4P+T (PE) 380/415V 63A FSQCP125-3 BP125-3 3P+T (PE) 380/415V 125A FSQCP125-31 BP125-31 3P+T (PE) 480/500V 125A FSQCP125-4 BP125-4 4P+T (PE) 380/415V 125A FSQCP125-41 BP125-41 4P+T (PE) 480/500V 125A C A A A GU MATR.-ANNO S. Nr.-YEAR www.feam-ex.comS.r.l. II 2G Ex d[ ] IICT II 2D Ex tD [ ]A21 IP66T °C BKI 08 ATEX 0480722 V Hz W A Ta NON APRIRE SOTTO TENSIONE /DO NOT OPEN WHILE ENERGIZED AD OGNI APERTURA DEL COPERCHIO RIPRISTINARE IL GRASSO AL SILICONE ACCERTARSI CHE LE VALVOLE DI RESPIRAZIONE E DRENAGGIO SIANO SEMPRE CHIUSE RENEW SILICONE GREASE EVERY TIME COVER IS OPENED AND MAKE SURE THAT THE DRAIN AND BREATHER VALVES ARE ALWAYS CLOSED 11.10.93 GU MATR.-ANNO S. Nr.-YEAR www.feam-ex.comS.r.l. II 2G Ex d[ ] IICT II 2D Ex tD [ ]A21 IP66T °C BKI 08 ATEX 0480722 V Hz W A Ta NON APRIRE SOTTO TENSIONE /DO NOT OPEN WHILE ENERGIZED AD OGNI APERTURA DEL COPERCHIO RIPRISTINARE IL GRASSO AL SILICONE ACCERTARSI CHE LE VALVOLE DI RESPIRAZIONE E DRENAGGIO SIANO SEMPRE CHIUSE RENEW SILICONE GREASE EVERY TIME COVER IS OPENED AND MAKE SURE THAT THE DRAIN AND BREATHER VALVES ARE ALWAYS CLOSED 11.10.93 Via M. Pagano, 3 I-20090Trezzano s/N ITALY www.feam-ex.com II2 GD0722 CUSTODIA tipo ENCLOSURE type V Hz A BKI 08 ATEX 019 Ta W Ex d IIB+H Ex tD A21 IP66T °C NON APRIRE SOTTOTENSIONE DO NOT OPENWHILE ENERGIZED Ad ogni apertura del coperchio ripristinare il grasso ai siliconi. accertarsi che le valvole di respirazione e drenaggio siano sempre chiuse Renew silicone grease every tyme cover is opened. and make sure that the drain and breather valves are always closed. VA 11.00.88 S.r.l. 2 T year s/n GU MATR.-ANNO S. Nr.-YEAR www.feam-ex.comS.r.l. II 2G Ex d[ ] IICT II 2D Ex tD [ ]A21 IP66T °C BKI 08 ATEX 0480722 V Hz W A Ta NON APRIRE SOTTO TENSIONE /DO NOT OPEN WHILE ENERGIZED AD OGNI APERTURA DEL COPERCHIO RIPRISTINARE IL GRASSO AL SILICONE ACCERTARSI CHE LE VALVOLE DI RESPIRAZIONE E DRENAGGIO SIANO SEMPRE CHIUSE RENEW SILICONE GREASE EVERY TIME COVER IS OPENED AND MAKE SURE THAT THE DRAIN AND BREATHER VALVES ARE ALWAYS CLOSED 11.10.93 GU MATR.-ANNO S. Nr.-YEAR www.feam-ex.comS.r.l. II 2G Ex d[ ] IICT II 2D Ex tD [ ]A21 IP66T °C BKI 08 ATEX 0480722 V Hz W A Ta NON APRIRE SOTTO TENSIONE /DO NOT OPEN WHILE ENERGIZED AD OGNI APERTURA DEL COPERCHIO RIPRISTINARE IL GRASSO AL SILICONE ACCERTARSI CHE LE VALVOLE DI RESPIRAZIONE E DRENAGGIO SIANO SEMPRE CHIUSE RENEW SILICONE GREASE EVERY TIME COVER IS OPENED AND MAKE SURE THAT THE DRAIN AND BREATHER VALVES ARE ALWAYS CLOSED 11.10.93 Via M. Pagano, 3 I-20090Trezzano s/N ITALY www.feam-ex.com II2 GD0722 CUSTODIA tipo ENCLOSURE type V Hz A BKI 08 ATEX 019 Ta W Ex d IIB+H Ex tD A21 IP66T °C NON APRIRE SOTTOTENSIONE DO NOT OPENWHILE ENERGIZED Ad ogni apertura del coperchio ripristinare il grasso ai siliconi. accertarsi che le valvole di respirazione e drenaggio siano sempre chiuse Renew silicone grease every tyme cover is opened. and make sure that the drain and breather valves are always closed. VA 11.00.88 S.r.l. 2 T year s/n Ex d IIC Ex d IIB A B C 14 - Feam Catalogue 03 CPSCP - FSQCP/BP - Typical assembling Please refer to cpsc/fsqc bulletin for industrial application sockets and plugs colour marking CODE A [mm] TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) WEIGHT [Kg] DETAIL INTERLOCKED SOCKETS AND PLUGS SOCKET TYPE POLES VOLTAGE (50/60Hz) CURRENT INTERLOCKED SOCKETS AND PLUGS WITH ON-LOAD SWITCH SOCKET TYPE POLES VOLTAGE (50/60Hz) CURRENT INTERLOCKED SOCKETS AND PLUGS WITH CIRCUIT BREAKER SOCKET TYPE POLES VOLTAGE (50/60Hz) CURRENT 125A INTERLOCKED SOCKETS AND PLUGS SOCKET TYPE PLUG TYPE POLES VOLTAGE (50/60Hz) CURRENT 14 - Feam Catalogue 03 Ex Interlocked sockets & plugs CPSCP - FSQCP/BP - Technical Features REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. *WITHOUT ENCLOSURE (TO BE ORDERED SEPARATELY)
  • 15. YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment DXN DXNInstallation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D Ex interlocked sockets & plugs Mechanical characteristics interlocked SOCKETS & PLUGS Feam Catalogue 03 - 15 Material glass reinforced polyester resin, perfectly antistatic Pin configuration in 24 hours, according to voltages (CEE 17) Contacts "Head" nickel-silver braided wire for reliability and durability Terminals insensitive to vibration and thermal shok Cover-socket automatic opening Impact resistance IK08 Internal Switch Interlocked type (EN 60309-1) AC23 category (IEC 947-3, EN 60947-3), AC22 category (CEI EN 60947-3) SWITCH SOCKETS & PLUGS DXN1 ATEX 94/9/EC IECEx INMETRO GOST-R (RTR / RTN) EXECUTION II 2 G Ex de IIC T5 / T6 II 2 D Ex tD A21 T90°C/T70°C Ex de IIC T5 / T6 Ex tD A21 T90°C / T70°C Ex de IIC T5 / T6 Gb Ex tD A21 T90°C / T70°C Db 2 Ex de IIC T5 / T6 DIP A21 T90°C / T70°C AMBIENT TEMPERATURE -40°C ÷ +60°C -40°C ÷ +40°C -40°C ÷ +60°C -40°C ÷ +40°C -40°C ÷ +60°C -40°C ÷ +40°C -40°C ÷ +40°C PROTECTION DEGREE IP66/67 IP66/67 IP66/67 IP66/67 CERTIFICATE REF. LCIE 99 ATEX 6027X IECEx LCIE 09.0005X BVC 10.0026-X POCC FR. ГБ05.B03779 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-0; EN 61241-1 EC 60079-0; IEC 60079-1; IEC 60079-7; IEC 61241-0; IEC 61241-1 ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-7; ABNT NBR IEC 60079-31; ABNT NBR IEC 60529; ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 SWITCH SOCKETS & PLUGS DXN3 ATEX 94/9/EC IECEx INMETRO GOST-R (RTR / RTN) EXECUTION II 2 G Ex de IIC T5 / T6 II 2 D Ex tD A21 T90°C / T70°C Ex de IIC T5 / T6 Ex tD A21 T90°C / T70°C Ex de IIC T5 / T6 Gb Ex tD A21 T90°C / T70°C Db 2 Ex de IIC T5 / T6 DIP A21 T90°C / T70°C AMBIENT TEMPERATURE -40°C ÷ +60°C -40°C ÷ +40°C -40°C ÷ +60°C -40°C ÷ +40°C -40°C ÷ +60°C -40°C ÷ +40°C -40°C ÷ +40°C PROTECTION DEGREE IP66/67 IP66/67 IP66/67 IP66/67 CERTIFICATE REF. LCIE 99 ATEX 6149X IECEx LCIE 09.0006 BVC 10.0024 POCC FR. ГБ05.B02573 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-0; EN 61241-1 IEC 60079-0; IEC 60079-1; IEC 60079-7; IEC 61241-0; IEC 61241-1 ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-7; ABNT NBR IEC 60079-31; ABNT NBR IEC 60529 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004 SWITCH SOCKETS & PLUGS DXN6 ATEX 94/9/EC IECEx INMETRO GOST-R (RTR / RTN) EXECUTION II 2 G Ex de IIC T4 / T6 II 2 D Ex tD A21 T107°C / T80°C Ex de IIC T4 / T6 Ex tD A21 T107°C / T80°C Ex de IIC T4 / T6 Gb Ex tD A21 T107°C / T80°C Db 2 Ex de IIC T4 / T6 DIP A21 T107°C / T80°C AMBIENT TEMPERATURE -40°C ÷ +60°C -40°C ÷ +40°C -40°C ÷ +60°C -40°C ÷ +40°C -40°C ÷ +60°C -40°C ÷ +40°C -40°C ÷ +40°C PROTECTION DEGREE IP66/67 IP66/67 IP66/67 IP66/67 CERTIFICATE REF. LCIE 99 ATEX 6150X IECEx LCIE 09.0007 BVC 10.0025 POCC FR. ГБ05.B02573 RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 60079-7; EN 61241-0; EN 61241-1 IEC 60079-0; IEC 60079-1; IEC 60079-7; IEC 61241-0; IEC 61241-1 ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-7; ABNT NBR IEC 60079-31; ABNT NBR IEC 60529 ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004
  • 16. YOUR PARTNER FOR SAFETY Since 1961 DXN G F C A ØH ØH E B D DXN1 130 130 36 77 56 62 150 M20 0,40 DXN3 145 160 70 70 70 70 155 M25 0,70 DXN6 159 150 77 88 77 81 213 M25 1,00 T70°C (Ta -40°C/+40°C) T90°C (Ta-40°C/+60°C) T78°C (Ta -40°C/+40°C) T98°C (Ta-40°C/+60°C) T87°C (Ta -40°C/+40°C) T107°C (Ta-40°C/+60°C) T6 (-40°C/+40°C) T5 (-40°C/+60°C) T6 (-40°C/+40°C) T5 (-40°C/+60°C) T6 (-40°C/+40°C) T5 (-40°C/+60°C) DXN1 2514082 2518082 2P + T (PE) 24V 20A 2,5 DXN1 2514132 2518132 2P + T (PE) 48V 20A 2,5 DXN1 2514035 2518035 2P + T (PE) 110/130V 20A 2,5 DXN1 2514015 2518015 2P + T (PE) 220/250V 20A 2,5 DXN1 2514013 2518013 3P + T (PE) 380/415V 20A 2,5 DXN1 2514017 2518017 3P + N + T (PE) 380/415V 20A 2,5 DXN3 2534013 2538013 3P + T (PE) 380/415V 32A 6 DXN3 2534017 2538017 3P + N + T (PE) 380/415V 32A 6 DXN3 2534093 2538093 3P + T (PE) 500V 32A 6 DXN3 2534097 2538097 3P + N + T (PE) 500V 32A 6 DXN6 2564013 2568013 3P + T (PE) 380/415V 63A 16 DXN6 2564017 2568017 3P + N + T (PE) 380/415V 63A 16 DXN6 2564093 2568093 3P + T (PE) 500V 63A 16 DXN6 2564097 2568097 3P + N + T (PE) 500V 63A 16 ØH 16 - Feam Catalogue 03 Ex Interlocked sockets & plugs DXN Technical Features *DIFFERENT VOLTAGE FROM STANDARD, PLEASE CONTACT OUR SALES DEPT. CODE A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] CABLE GLANDS ØH TEMPERATURE CLASS (GAS) TEMPERATURE CLASS (DUSTS) WEIGHT [Kg] INTERLOCKED RECEPTACLES AND PLUGS TYPE SOCKET CODE PLUG CODE POLES VOLTAGE CURRENT TERMINALS [sqmm] PLUG SWITCH SOCKET REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only.