1. SIL Suitable Final Elements
FUNCTIONAL SAFETY OF
FIRE & GAS SYSTEMS
SA FIRE PROTECTION
2. FUNCTIONAL SAFETY
FUNCTIONAL SAFETY
• Definition
• SIS
• Requirements
• IEC 61508
• SIL
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 2SIL Suitable Final Elements
3. DEFINITION OF FUNCTIONAL SAFETY
Safety is the absence of an
unacceptable risk of physical injury to
people or damage to the properties
Functional Safety is part of the overall
safety which depends on the correct
functioning of a safety-related system
FUNCTIONAL SAFETY
• Definition
• SIS
• Requirements
• IEC 61508
• SIL
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 3SIL Suitable Final Elements
4. SAFETY INSTRUMENTED SYSTEM (SIS)
A Safety Instrumented System (SIS) or
Safety-related System is an appropriate
system required to reduce the risk
(shown by a hazard analysis) of the
Equipment Under Control (EUC)
A SIS performs one or more Safety
Functions to reduce the risk
FUNCTIONAL SAFETY
• Definition
• SIS
• Requirements
• IEC 61508
• SIL
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 4SIL Suitable Final Elements
5. REQUIREMENTS TO FUNCTIONAL SAFETY
Two types of requirements are necessary
to achieve Functional Safety:
Safety Function Requirements: the
scope of the Safety Function, derived
from the hazard analysis
Safety Integrity Requirements: the
probability that the Safety Function will
be performed satisfactorily, derived
from the risk assessment
FUNCTIONAL SAFETY
• Definition
• SIS
• Requirements
• IEC 61508
• SIL
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 5SIL Suitable Final Elements
6. THE STANDARD IEC 61508
IEC 61508 “Functional Safety of electrical
/electronic / programmable electronic
(E/E/PE) safety-related systems”:
Covers all the safety lifecycle activities
Contains requirements for preventing
failures and controlling failures,
ensuring safety even when faults are
present
Specifies the techniques and measures
to achieve the required Safety Integrity
FUNCTIONAL SAFETY
• Definition
• SIS
• Requirements
• IEC 61508
• SIL
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 6SIL Suitable Final Elements
7. SAFETY INTEGRITY LEVEL (SIL)
Safety Integrity is the probability that
the SIS will perform the required Safety
Functions satisfactorily
IEC 61508 specifies 4 levels of safety
performance for a Safety Function,
called Safety Integrity Level (SIL)
The Standard details the requirements
necessary to achieve each Safety
Integrity Level. SIL1 is the lowest level
and SIL4 is the highest
FUNCTIONAL SAFETY
• Definition
• SIS
• Requirements
• IEC 61508
• SIL
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 7SIL Suitable Final Elements
8. SAFETY INTEGRITY LEVEL (SIL)
FUNCTIONAL SAFETY
• Definition
• SIS
• Requirements
• IEC 61508
• SIL
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 8SIL Suitable Final Elements
Low demand mode of operation:
frequency of demands for the SIS not
greater than once per year, and not
greater than twice the proof-test
frequency
Safety Integrity Level (SIL)
Average Probability of Failure
on Demand (PFDavg)
4 ≥ 10-5 to < 10-4
3 ≥ 10-4 to < 10-3
2 ≥ 10-3 to < 10-2
1 ≥ 10-2 to < 10-1
9. FIRE & GAS SYSTEM
FUNCTIONAL SAFETY
F&G SYSTEM
• Objectives
• Effectiveness
• Components
• Final Elements
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 9SIL Suitable Final Elements
10. TASKS OF F&G SYSTEM
The main tasks of a F&G system are:
Detect any hazardous fire or gas
condition
Alert the personnel in the monitored
area
Activate the control and mitigation
systems
FUNCTIONAL SAFETY
F&G SYSTEM
• Tasks
• Effectiveness
• Components
• Final Elements
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 10SIL Suitable Final Elements
11. F&G SYSTEM EFFECTIVENESS
The F&G system Effectiveness is the
product of three factors:
Detection Coverage: the fraction of the
monitored area in which an eventual
hazard would be detected
Mitigation Effectiveness: the
probability that the activation of the
Final Elements would reduce the
consequence of a defined hazard
F&G Safety Availability (SA): 1-PFDavg
FUNCTIONAL SAFETY
F&G SYSTEM
• Tasks
• Effectiveness
• Components
• Final Elements
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 11SIL Suitable Final Elements
12. A F&G system consists of:
Detectors
Logic Solver
Final Elements
A chain is only as strong as its weakest
element
COMPONENTS OF F&G SYSTEM
FUNCTIONAL SAFETY
F&G SYSTEM
• Tasks
• Effectiveness
• Components
• Final Elements
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 12SIL Suitable Final Elements
LOGIC
SOLVER
FINAL
ELEMENTS
DETECTORS
13. The F&G Effectiveness is related to the
Safety Availability of all its components
SA has developed
SIL suitable Final Elements
for the main fire-fighting systems
FINAL ELEMENTS
FUNCTIONAL SAFETY
F&G SYSTEM
• Tasks
• Effectiveness
• Components
• Final Elements
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 13SIL Suitable Final Elements
LOGIC
SOLVER
FINAL
ELEMENTS
DETECTORS
NIAGARA
ELECTRIC
MONITORS
ELECTRIC
ACTUATORS
VDD
DELUGE
VALVES
14. ELECTRIC MONITOR
NIAGARA SERIES
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
• Description
• Main features
• Advantages
• Application
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 14SIL Suitable Final Elements
15. DESCRIPTION
The fire-fighting monitors
Niagara series are electric
type remote controlled
water cannons, intended to
deliver large amount of water
towards remote targets.
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
• Description
• Main features
• Advantages
• Application
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 15SIL Suitable Final Elements
The monitor architecture comprises
of a Logic Controller and one or more
monitor assemblies
16. MAIN FEATURES
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
• Description
• Main features
• Advantages
• Application
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 16SIL Suitable Final Elements
Automatic self-diagnostic
analysis
Remote controlled
Designed for sea water and
water foam solution
Suitability for SIL2 systems
validated by Bureau Veritas
17. ADVANTAGES
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
• Description
• Main features
• Advantages
• Application
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 17SIL Suitable Final Elements
Automatic self-diagnostic analysis: at
regular intervals the self-diagnostic
system in the Logic Controller checks the
correct operation on given commands
Constant monitoring of any possible
failure of monitor and nozzle
Reduction of the probability that
faults, taking place between regular
maintenance, will pass undetected
Increased reliability on demand
18. APPLICATION
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
• Description
• Main features
• Advantages
• Application
ELECTRIC ACTUATOR
VDD DELUGE VALVE
28/02/2015 18SIL Suitable Final Elements
Designed for petrochemical
jetty and marine harbor and
structure cooling
Recommended for those systems which
require:
A low probability of failure on demand
A fire protection system with a high
Safety Integrity Level
A large amount of water towards
remote targets
19. DOUBLE COIL
ELECTRIC ACTUATOR
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
• Description
• Main features
• Application
VDD DELUGE VALVE
28/02/2015 19SIL Suitable Final Elements
20. DESCRIPTION
The double coil electric actuator has
been developed to sharply reducing
the probability of failure of a pilot
cylinder of a gaseous based fire
protection system (carbon dioxide,
inert gases, halocarbons) or a water
mist system
SIL Suitable Final Elements
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
• Description
• Main features
• Application
VDD DELUGE VALVE
28/02/2015 20
21. MAIN FEATURES
Redundancy: the actuator has two coils
which receive two independent signals
from the Logic Solver. If one coil should
fail, the other coil is able to open the
cylinder valve
Suitability for SIL2
systems validated
by Bureau Veritas
SIL Suitable Final Elements
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
• Description
• Main features
• Application
VDD DELUGE VALVE
28/02/2015 21
22. APPLICATION
Designed for the protection of gas
turbines and their generators, electronic
rooms and general installations on FPSO
Recommended for those systems which
require:
A low probability of failure on demand
A fire protection system with a high
Safety Integrity Level
SIL Suitable Final Elements
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
• Description
• Main features
• Application
VDD DELUGE VALVE
28/02/2015 22
23. DOUBLE CHAMBER DELUGE VALVE
MODEL VDD
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
• Description
• Principle of operation
• Main features
• Advantages
• Application
28/02/2015 23SIL Suitable Final Elements
24. DESCRIPTION
The VDD deluge valve combines all the
functions of a traditional deluge valve
with a fully redundant architecture,
designed to achieve a higher Safety
Availability
The VDD deluge valve
has two priming
chambers, each one
provided with its own
diaphragm and trim
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
• Description
• Principle of operation
• Main features
• Advantages
• Application
28/02/2015 24SIL Suitable Final Elements
25. PRINCIPLE OF OPERATION
In the set position (valve closed)
The pressure of the water trapped in
the priming chambers holds the
diaphragms on the valve seats, keeping
the valve closed
In fire condition (valve open)
The pressure is released from the
priming chambers. The water supply
pressure forces the diaphragm off the
seats, opening the valve
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
• Description
• Principle of operation
• Main features
• Advantages
• Application
28/02/2015 25SIL Suitable Final Elements
26. MAIN FEATURES
Fully redundant system
Built-in emergency bypass line that
operates on both priming chambers in
“hot back-up”
Continuous fire protection
Designed to overcome a double failure
Suitability for SIL3 systems validated by
Bureau Veritas
Under UL testing for UL/cUL Listing
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
• Description
• Principle of operation
• Main features
• Advantages
• Application
28/02/2015 26SIL Suitable Final Elements
27. ADVANTAGES
Built-in emergency bypass line
Each priming chamber provides the
nominal design waterway for the fire
protection system
The system is fully redundant
The time to respond to a failure is
reduced to zero
No need of an external bypass line on
the skid: reduction of dimensions,
weight and cost of the skid
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
• Description
• Principle of operation
• Main features
• Advantages
• Application
28/02/2015 27SIL Suitable Final Elements
28. ADVANTAGES
Designed to overcome a double failure
A hydraulic bridge between the trims
allows each trim to control both the
diaphragms
In case of failure of one trim, the other
trim can open both the priming
chambers
The VDD deluge valve can overcome a
double failure
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
• Description
• Principle of operation
• Main features
• Advantages
• Application
28/02/2015 28SIL Suitable Final Elements
29. ADVANTAGES
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
• Description
• Principle of operation
• Main features
• Advantages
• Application
28/02/2015 29SIL Suitable Final Elements
Designed to overcome a double failure
Fault Tree of the VDD deluge valve
30. ADVANTAGES
Fire protection system always in service
Two built-in isolation
valves allow alternate
in-line maintenance
to be performed
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
• Description
• Principle of operation
• Main features
• Advantages
• Application
28/02/2015 30SIL Suitable Final Elements
An interlock system prevents
the accidental or incorrect
rotation of the isolation valves
31. APPLICATION
Made of Ni-Al-Bronze, a
highly resistant material
Specifically designed for
harsh environments, such
as oil & gas onshore and
offshore and chemical and
nuclear plants installations
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
• Description
• Principle of operation
• Main features
• Advantages
• Application
28/02/2015 31SIL Suitable Final Elements
Sea water, foam
concentrate and
water foam solution
32. APPLICATION
Recommended for those systems which
require:
A low probability of failure on demand
A fire protection system with a high
Safety Integrity Level
Continuity of fire protection during
maintenance or repair
Reduction of weight, dimension and
cost of the skid
FUNCTIONAL SAFETY
F&G SYSTEM
NIAGARA MONITOR
ELECTRIC ACTUATOR
VDD DELUGE VALVE
• Description
• Principle of operation
• Main features
• Advantages
• Application
28/02/2015 32SIL Suitable Final Elements
33. REFERENCE CONTACT
SA Fire Protection
Viale Europa 121-123
Cascina ( PISA ) – Italy
Ph. +39.050.70.30.06
Fax. +39.050.70.35.80
export@sasrl.it