The AC and DC bridge both are used for measuring the unknown parameter of the circuit. The AC bridge measures the unknown impedance of the circuit. The DC bridge measures the unknown resistance of the circuit.
33. Four arm bridge – AC bridge
Inductance and capacitance can be measured
Galvanometer is replaced by Vibration Galvanometer
34. Maxwell inductance bridge
Used to measure inductance
◦ By comparison either with a standard variable self inductance.
Maxwell inductance capacitance bridge
Used to measure inductance
◦ By comparison either with a standard variable capacitance.
35. Advantages
1) The balance equation is independent of frequency.
2) The two balance equations are independent ; if we choose R4 and
C4 as variable elements.
3) The bridge yields simple expression for unknown L1 and R1 in
terms of known elements.
4) It is useful for measurement of wide range of inductance at power
and audio frequencies.
36. Disadvantages
Variable standard capacitor will be expensive
It cannot be used for measurement of high Q values, it is limited to
measure low Q value (1<Q<10)