A novel technique of radiation delivery with ultrahigh dose rate radiation therapy delivered in milisecond of time. Although, still in investigational phase

Related Books

Free with a 30 day trial from Scribd

See all

Related Audiobooks

Free with a 30 day trial from Scribd

See all

Flash radiation therapy

  1. 1. FLASH Radiation Therapy Basics and clinical translation
  2. 2. History & Preclinical application • Described by Town et al (1967) first • Applied to tumours first (Favaudon & Vozenin et al: 2015-16) • Bourhis et al (2019): first patient treatment • Preclinical application • 28, 31, 34 Gray delivered to pig skin in a volume of <10 cc (2.6 cm diameter): No necrosis seen at 9 months as compared to conventional therapy • 31 Gray delivered to approx. 120 cc: No necrosis
  3. 3. Physical parameters: FLASH Effects • Dose rate: >40 Gray/sec (possible); >100-150 Gray/sec (likely) • Reproducible effect • Dose / pulse (> 1.5 Gy & few pulses) • Dose rate in the pulse (>= 106 Gy /s) • Overall time (< 100 ms) • Dose/fraction • Begins to show up at >10 Gray/fraction • No dose limiting effect observed in animal models between 25-41 Gray • Radiation type • Most reproducible with electrons • Ongoing work on X-rays and protons
  4. 4. Biological effect • Complete oxygen depletion in cells: well oxygenated normal tissues are spared • Difference in redox biology of the oxygen metabolism • Different immune effect (less cytokine release: less normal tissue damage) • Differential gene expression induced by FLASH
  5. 5. Optimizing therapeutic outcome
  6. 6. Advantages over conventional therapy • Better normal tissue sparing: 25-30% • Fewer fractions of treatment (1-3): compliance and QOL • Ultra short treatment times (ms): No intrafraction motion management
  7. 7. Challenges ahead • Modification of existing LINAC to match physical parameters • Modified VARIAN Linac at Standford • Modified ELEKTA Linac at Lund university, Sweden • Lausanne University Hospital, the eRT6 Oriatron (5.6 MeV, electron linac, PMB, Peynier France):First patient treated with this • Pluridirectional High-energy Agile Scanning Electronic Radiotherapy (PHASER): Under evaluation • Development of FLASH VHEE (very high energy electrons); X-Ray and proton systems • Quality assurance and dosimetric verification • Robust dose monitoring and stopping system • Evolution of dose fractionation schedules for clinical routine use
  • SarbjotKaur5

    Aug. 24, 2021
  • AkshayKashyap27

    Aug. 23, 2021
  • sdevarajus

    Jul. 5, 2021
  • SuchetaBiswas3

    Jul. 5, 2021
  • shalinisingh628

    Apr. 12, 2021
  • SowjanyaVasam

    Mar. 26, 2021
  • janakidhashanan

    Feb. 10, 2021
  • HarshavardhanBhosale2

    Feb. 4, 2021
  • GraceSirisha

    Jan. 29, 2021

A novel technique of radiation delivery with ultrahigh dose rate radiation therapy delivered in milisecond of time. Although, still in investigational phase

Views

Total views

954

On Slideshare

0

From embeds

0

Number of embeds

5

Actions

Downloads

36

Shares

0

Comments

0

Likes

9

×