SlideShare a Scribd company logo
1 of 14
1
Advance V/S conventional
2
Advance
Ozone
Injection
Technology
for IAQ
3
Advance
In Duct
Ozone
Injection
Technology
for IAQ
4
Conventional
In Duct
Plate Type
Ozone
Injection
Technology
for IAQ
- Ozone Injection Technology for IAQ
5
No. Points Of Comparison Advance Conventional
1 Technology Ozone Cell  Plate Type 
2 Ozone Injection In or Outside Duct 
[Duct Not Mandatory]
In Duct 
[Duct Mandatory]
3 Ozonator Installation Outside Duct  Inside Duct 
4 Integration Point Return Air Duct
[Optimum] 
Supply Air Duct
[Prohibited] 
5 Occupant Safety Highest 
[Injection in Return Line]
Poor 
[Injection in Supply Line]
- Ozone Injection Technology for IAQ
6
No. Points Of Comparison Advance Conventional
6 Feed Gas -
Ozone Generation
Doesn’t Depend on AHU Air
Supply 
Depends on AHU Air

7 Effect Of Fine Dust Zero Effect  Can't prevent settling on
Plates 
8 Ozone Capacity Measurable  Not Measurable 
9 Ozone Generator
Installation
No part is installed within
Duct 
Inside Duct 
10 Air Flow Restriction Zero Restriction  Ozone Plates Restricts Air
Flow 
- Ozone Injection Technology for IAQ
7
No. Points Of Comparison Advance Conventional
11 Current Concentration
[Current per Unit Area]
Uniform Through Out It’s
Life Span 
Gradually Depreciates

12 Service Frequency Once In Year  Monthly Plate Cleaning 
13 Efficient Life Span 12 – 15 years  1 – 2 Years
14 Emergency Stop Present  Absent 
15 Occupational Safety Highest  Poor 
16 Cleans AHU YES  NO 
- Technology
8
• Advance Technology :- Ozonator is Corona discharge type & installed in return air line,
Outside Duct & Ozone is injected through Anti-oxidant tubing 
• Conventional Technology :- In conventional technology Plate type ozonator in installed
in Supply air line, within duct 
- Ozone Generator Installation
9
• Advance Technology :- Ozone Generator is installed in AHU room Outside Duct. 
• Conventional Technology :- A Cut Out is made in duct & Plate Type ozone generator is
installed within Supply Air duct. 
• Return air has the maximum pollutant, so ideally ozone injection point should be in
return air. Unfortunately Plate type ozonator can not be installed in return air, because
return air has more dust compared to supply air. If plate type ozonators are installed in
return air duct, it Quickly gets covered by dust. Eventually restricting generation of
ozone.
- Ozone Generation
10
• Advance Technology :- Does not depend Upon Circulating Air in Duct, Ozone generator
has built in Air Pump to produce ozone. 
• Conventional Technology :- It uses in duct circulating Air to Produce Ozone & depends
upon Circulating Air 
• Air Flow Quantity & Velocity in duct is designed as per HVAC design standards & not as
per Ozone Generator requirement.
- Effect of Fine dust & Colloidal Particulate Matters
11
• Advance Technology :- Ozone generation is installed outside duct & does not have any
effect of pollutant present in ducts. 
• Conventional Technology :- It uses in duct circulating Air to Produce Ozone & depends
upon Circulating Air 
1. Fine dust & colloidal suspended particulate matter [SPM] gets attracted on ozone
generator plate, due to static electric charge on plates. This dust particle coating on
plates reduces generation of ozone gas.
- Effect of Fine dust & Colloidal Particulate Matters
12
2. Also demands more frequent cleaning by completely removing ozone generator from duct.
3. Due to Fine dust & colloidal suspended particulate matter [SPM] getting deposited on
ozone generator plates, eventually reduces the open surface area exposed between two
plates. This open clean area is responsible for generating corona & producing ozone from
induct air. When high voltage is applied to clean plates of plate type ozone generator the
uniform current flows between two plates of ozone generator. This is specified in term of
current per unit area. Now over the period of time when dust gets coated on these plates,
the current through dust reduces. Also relatively open [clean] area current per unit area
increases, above design current, damaging ozone plates beyond repair.
- Conclusion
13
1. For Occupant Safety & Efficiency, Ozone Generator should be installed in
Return Air line/duct & Never in Supply Air Line/duct
2. Ozone generator should not be placed inside duct, it should be installed
outside duct.
3. Ozone generator should be concentric cylindrical & should not be plate type.
4. Ozone gas generation quantity should not be as per manufacturers
specification/Test Certificate [TC], generated ozone should be
demonstrated/validated as per procedure prescribed by “International Ozone
Association” [IOA] at site or in factory. This can be tested either by ozone
analyzer or Chemical titration method.
Thank You
14
Solution Engineer : Mr. Sunil Shah
Contact : +91-93212 34527
Mail ID : sunilshah@chemtronicsindia.com
URL : www.chemtronicsindia.com
www.ozonegeneratorindia.com
www.m.chemtronicsindia.com

More Related Content

Viewers also liked (11)

Everything about ozone V2
Everything about ozone V2Everything about ozone V2
Everything about ozone V2
 
Ozone in laundry cost & energy saving
Ozone in laundry   cost & energy savingOzone in laundry   cost & energy saving
Ozone in laundry cost & energy saving
 
Application Of Ozone - Hospitality
Application Of Ozone - HospitalityApplication Of Ozone - Hospitality
Application Of Ozone - Hospitality
 
Application Of Ozone & AOP in Aquaculture & Hatcheries - by chemtronics
Application Of Ozone & AOP in Aquaculture & Hatcheries - by chemtronicsApplication Of Ozone & AOP in Aquaculture & Hatcheries - by chemtronics
Application Of Ozone & AOP in Aquaculture & Hatcheries - by chemtronics
 
Case study - Textile ETP [Spinners & Spinners]
Case study - Textile ETP [Spinners & Spinners]Case study - Textile ETP [Spinners & Spinners]
Case study - Textile ETP [Spinners & Spinners]
 
Ozone generator by eltech engineers
Ozone generator by eltech engineersOzone generator by eltech engineers
Ozone generator by eltech engineers
 
Features - GREEN STP AD+
Features - GREEN STP AD+Features - GREEN STP AD+
Features - GREEN STP AD+
 
Rethink Cooling Tower Water Treatment
Rethink Cooling Tower Water TreatmentRethink Cooling Tower Water Treatment
Rethink Cooling Tower Water Treatment
 
Segmentation, Targeting & Positioning: A Case Study of Vitacimin
Segmentation, Targeting & Positioning: A Case Study of VitaciminSegmentation, Targeting & Positioning: A Case Study of Vitacimin
Segmentation, Targeting & Positioning: A Case Study of Vitacimin
 
Bacteria enumeration
Bacteria enumerationBacteria enumeration
Bacteria enumeration
 
Water microbiology
Water microbiologyWater microbiology
Water microbiology
 

More from Chemtronics Technologies (India) Pvt. Ltd. (8)

Duct Mounted Ozone Generator for STP Exhaust Air Treatment V2.pptx
Duct Mounted Ozone Generator for STP Exhaust Air Treatment V2.pptxDuct Mounted Ozone Generator for STP Exhaust Air Treatment V2.pptx
Duct Mounted Ozone Generator for STP Exhaust Air Treatment V2.pptx
 
Hospital - Un compromised Safety and Hygiene
Hospital  - Un compromised Safety and HygieneHospital  - Un compromised Safety and Hygiene
Hospital - Un compromised Safety and Hygiene
 
Dry Advance Disinfection Tunnel by Chemtronics
Dry Advance Disinfection Tunnel by ChemtronicsDry Advance Disinfection Tunnel by Chemtronics
Dry Advance Disinfection Tunnel by Chemtronics
 
Design criteria, Exhaust air odour Destruction
Design criteria, Exhaust air odour DestructionDesign criteria, Exhaust air odour Destruction
Design criteria, Exhaust air odour Destruction
 
Commercial Kitchen Exhaust Air Treatment - Odor, Smoke & Grease Control
Commercial Kitchen Exhaust Air Treatment - Odor, Smoke & Grease ControlCommercial Kitchen Exhaust Air Treatment - Odor, Smoke & Grease Control
Commercial Kitchen Exhaust Air Treatment - Odor, Smoke & Grease Control
 
Application Of Ozone - Hospitality
Application Of Ozone - HospitalityApplication Of Ozone - Hospitality
Application Of Ozone - Hospitality
 
Ozone cip
Ozone cipOzone cip
Ozone cip
 
Why do we need swimming pool design consultant
Why do we need swimming pool design consultantWhy do we need swimming pool design consultant
Why do we need swimming pool design consultant
 

Recently uploaded

IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsEnterprise Knowledge
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdfhans926745
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityPrincipled Technologies
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Igalia
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxMalak Abu Hammad
 
Maximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxMaximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxOnBoard
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptxHampshireHUG
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking MenDelhi Call girls
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...gurkirankumar98700
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationMichael W. Hawkins
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking MenDelhi Call girls
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slidevu2urc
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Servicegiselly40
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 3652toLead Limited
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Drew Madelung
 
Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Paola De la Torre
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 

Recently uploaded (20)

IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI Solutions
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
 
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptx
 
Maximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxMaximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptx
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day Presentation
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 

Ozone injection technique in hvac - modern vs conventional

  • 5. - Ozone Injection Technology for IAQ 5 No. Points Of Comparison Advance Conventional 1 Technology Ozone Cell  Plate Type  2 Ozone Injection In or Outside Duct  [Duct Not Mandatory] In Duct  [Duct Mandatory] 3 Ozonator Installation Outside Duct  Inside Duct  4 Integration Point Return Air Duct [Optimum]  Supply Air Duct [Prohibited]  5 Occupant Safety Highest  [Injection in Return Line] Poor  [Injection in Supply Line]
  • 6. - Ozone Injection Technology for IAQ 6 No. Points Of Comparison Advance Conventional 6 Feed Gas - Ozone Generation Doesn’t Depend on AHU Air Supply  Depends on AHU Air  7 Effect Of Fine Dust Zero Effect  Can't prevent settling on Plates  8 Ozone Capacity Measurable  Not Measurable  9 Ozone Generator Installation No part is installed within Duct  Inside Duct  10 Air Flow Restriction Zero Restriction  Ozone Plates Restricts Air Flow 
  • 7. - Ozone Injection Technology for IAQ 7 No. Points Of Comparison Advance Conventional 11 Current Concentration [Current per Unit Area] Uniform Through Out It’s Life Span  Gradually Depreciates  12 Service Frequency Once In Year  Monthly Plate Cleaning  13 Efficient Life Span 12 – 15 years  1 – 2 Years 14 Emergency Stop Present  Absent  15 Occupational Safety Highest  Poor  16 Cleans AHU YES  NO 
  • 8. - Technology 8 • Advance Technology :- Ozonator is Corona discharge type & installed in return air line, Outside Duct & Ozone is injected through Anti-oxidant tubing  • Conventional Technology :- In conventional technology Plate type ozonator in installed in Supply air line, within duct 
  • 9. - Ozone Generator Installation 9 • Advance Technology :- Ozone Generator is installed in AHU room Outside Duct.  • Conventional Technology :- A Cut Out is made in duct & Plate Type ozone generator is installed within Supply Air duct.  • Return air has the maximum pollutant, so ideally ozone injection point should be in return air. Unfortunately Plate type ozonator can not be installed in return air, because return air has more dust compared to supply air. If plate type ozonators are installed in return air duct, it Quickly gets covered by dust. Eventually restricting generation of ozone.
  • 10. - Ozone Generation 10 • Advance Technology :- Does not depend Upon Circulating Air in Duct, Ozone generator has built in Air Pump to produce ozone.  • Conventional Technology :- It uses in duct circulating Air to Produce Ozone & depends upon Circulating Air  • Air Flow Quantity & Velocity in duct is designed as per HVAC design standards & not as per Ozone Generator requirement.
  • 11. - Effect of Fine dust & Colloidal Particulate Matters 11 • Advance Technology :- Ozone generation is installed outside duct & does not have any effect of pollutant present in ducts.  • Conventional Technology :- It uses in duct circulating Air to Produce Ozone & depends upon Circulating Air  1. Fine dust & colloidal suspended particulate matter [SPM] gets attracted on ozone generator plate, due to static electric charge on plates. This dust particle coating on plates reduces generation of ozone gas.
  • 12. - Effect of Fine dust & Colloidal Particulate Matters 12 2. Also demands more frequent cleaning by completely removing ozone generator from duct. 3. Due to Fine dust & colloidal suspended particulate matter [SPM] getting deposited on ozone generator plates, eventually reduces the open surface area exposed between two plates. This open clean area is responsible for generating corona & producing ozone from induct air. When high voltage is applied to clean plates of plate type ozone generator the uniform current flows between two plates of ozone generator. This is specified in term of current per unit area. Now over the period of time when dust gets coated on these plates, the current through dust reduces. Also relatively open [clean] area current per unit area increases, above design current, damaging ozone plates beyond repair.
  • 13. - Conclusion 13 1. For Occupant Safety & Efficiency, Ozone Generator should be installed in Return Air line/duct & Never in Supply Air Line/duct 2. Ozone generator should not be placed inside duct, it should be installed outside duct. 3. Ozone generator should be concentric cylindrical & should not be plate type. 4. Ozone gas generation quantity should not be as per manufacturers specification/Test Certificate [TC], generated ozone should be demonstrated/validated as per procedure prescribed by “International Ozone Association” [IOA] at site or in factory. This can be tested either by ozone analyzer or Chemical titration method.
  • 14. Thank You 14 Solution Engineer : Mr. Sunil Shah Contact : +91-93212 34527 Mail ID : sunilshah@chemtronicsindia.com URL : www.chemtronicsindia.com www.ozonegeneratorindia.com www.m.chemtronicsindia.com