QUICK-REFERENCE
                                           RESET
                                           GUIDE
            FOR REFERENCE USE ONLY
The data contained herein is intended to assist troubleshooting
only and is not a substitute for Embraer and/or operator’s
manuals. Fault correcting maintenance and the aircraft’s “return
to service” testing shall be accomplished in full accordance with
proper Embraer and/or operator’s manuals.

All inquires regarding this material should be addressed to:
170techpubs@embraer.com.br

                                                                             JANUARY 2006
                                                                  REVISION 10 – May 2010

      Copyright 2010 by EMBRAER - Empresa Brasileira de Aeronáutica S.A. All rights reserved. This
   document shall not be copied or reproduced, whether in whole or in part, in any form or by any means
     without the express written authorization of Embraer. The information, technical data, designs and
  drawings disclosed in this document are property information of Embraer or third parties and shall not be
                    used or disclosed to any third party without permission of Embraer.
TABLE OF CONTENTS

INTRODUCTION ......................................................................... 8
MAU AND SPDA RESET SAFETY PROCEDURES ................. 10
GENERAL INFORMATION ....................................................... 15
ACARS FROZEN ...................................................................... 16
ADS 1 FAIL............................................................................... 17
ADS 1 HTR FAIL ...................................................................... 17
ADS 1 HTR FAULT................................................................... 18
ADS 2 FAIL............................................................................... 18
ADS 2 HTR FAIL ...................................................................... 19
ADS 2 HTR FAULT................................................................... 20
ADS 3 FAIL............................................................................... 21
ADS 3 FAIL............................................................................... 22
ADS 3 SLIPCOMP FAIL ........................................................... 23
ADS 4 HTR FAIL ...................................................................... 24
ADS 4 SLIPCOMP FAIL ........................................................... 25
ADS PROBE 1 FAIL ................................................................. 26
ADS PROBE 2 FAIL ................................................................. 27
ADS PROBE 3 FAIL ................................................................. 28
ADS PROBE 4 FAIL ................................................................. 29
AFCS FAULT............................................................................ 30
A-I ENG 1 FAULT ..................................................................... 31
A-I ENG 2 FAULT ..................................................................... 32
A-I WING FAIL.......................................................................... 33
AMBER "X" ON RECIRC FAN INDICATION
(ECS SYNOPTIC PAGE) .......................................................... 34
AOA LIMIT FAIL ....................................................................... 35
APPR 2 NOT AVAIL ................................................................. 35
APU FAIL.................................................................................. 36
APU FUEL SOV FAIL ............................................................... 36
AT FAIL .................................................................................... 37
AURAL WRN SYS FAIL ........................................................... 38
AURAL WRN SYS FAULT........................................................ 38
AUTOBRAKE FAIL................................................................... 39
AVNX MAU 1A FAIL ................................................................. 39
AVNX MAU 1A FAULT ............................................................. 40
AVNX MAU 1B FAIL ................................................................. 41
AVNX MAU 1B FAULT ............................................................. 42
AVNX MAU 2A FAIL ................................................................. 43

Page 2                                                                              May 10
AVNX MAU 2A FAULT .............................................................44
AVNX MAU 2B FAIL .................................................................45
AVNX MAU 2B FAULT .............................................................46
AVNX MAU 3A FAIL .................................................................47
AVNX MAU 3A FAULT .............................................................48
AVNX MAU 3B FAIL .................................................................49
AVNX MAU 3B FAULT .............................................................50
BLEED 1 FAIL...........................................................................51
BLEED 1 OFF ...........................................................................52
BLEED 2 FAIL...........................................................................53
BLEED 2 OFF ...........................................................................54
BRK CONTROL FAULT............................................................55
BRK LH FAULT ........................................................................55
BRK LH FAULT ........................................................................56
CAS MSG INDICATION ON PFD ..............................................56
CENTER EBAY FANS FAIL......................................................57
CHIMES NOT AVAILABLE - ALL POSITIONS .........................58
CMF 1 FAIL...............................................................................58
"CMC IN AIR" OR "CMC CONNECTION FAILED"
MESSAGES ON CMC SCREEN ...............................................59
COPILOT DAP PROBLEMS - DISPLAY, VOLUME AND
CONTROLS ..............................................................................60
CVR AFT FAIL ..........................................................................60
CVR FWD FAIL .........................................................................61
DATALINK TIMEOUT SHOWS ON THE MCDU 1
SCRATCHPAD..........................................................................61
DATALINK TIMEOUT SHOWS ON THE MCDU 2
SCRATCHPAD..........................................................................62
EICAS FAULT ...........................................................................62
ELEVATOR FAULT...................................................................63
ELEVATOR LH FAIL.................................................................63
ELEVATOR RH FAIL ................................................................64
ENG 1 FADEC FAULT ..............................................................65
ENG 1 FUEL SW FAIL .............................................................66
ENG 2 FADEC FAULT ..............................................................67
ENG 2 FUEL SW FAIL .............................................................68
ENG TLA TRIM FAIL ................................................................69
FDR AFT FAIL ..........................................................................70
FDR FWD FAIL .........................................................................70
FLAP FAIL ................................................................................71

Page 3                                                                           May 10
FLAP LO RATE ........................................................................ 72
FLT CTRL BIT EXPIRED .......................................................... 73
FLT CTRL FAULT..................................................................... 74
FLT CTRL NO DISPATCH ........................................................ 75
FLT CTRL NO DISPATCH/FLT CTRL FAULT/FLT CTRL BIT
EXPIRED, AUTO CONFIG TRIM FAIL (ALTERNATE
PROCEDURE) .......................................................................... 76
FMS 1 FAIL............................................................................... 77
FMS 2 FAIL............................................................................... 78
FMS1 TIMEOUT SHOWS ON THE MCDU 1
SCRATCHPAD ......................................................................... 79
FMS1-2 TIMEOUT SHOWS ON THE MCDU 1
SCRATCHPAD ......................................................................... 80
FMS1-2 TIMEOUT SHOWS ON THE MCDU 2
SCRATCHPAD ......................................................................... 81
FMS2 TIMEOUT SHOWS ON THE MCDU 2
SCRATCHPAD ......................................................................... 82
FUEL DC PUMP FAIL............................................................... 83
FUEL EQUAL-XFEED OPEN.................................................... 83
FWD EBAY FANS FAIL............................................................ 84
GND PROX FAIL ...................................................................... 85
GROUND SPOILERS FAIL....................................................... 86
HUD 1 FAIL .............................................................................. 86
HUD 2 FAIL .............................................................................. 87
HUD FAIL ................................................................................. 88
ICE DETECTOR 1 FAIL ............................................................ 89
ICE DETECTOR 2 FAIL ............................................................ 90
INPH AUDIO (BETWEEN DAPS) - NOISY
OR NOT AVAILABLE ............................................................... 91
INVERTER FAIL ....................................................................... 91
IRS 1 FAIL ................................................................................ 92
IRS 2 FAIL ................................................................................ 92
IRS PRES POS INVALID .......................................................... 93
LAV SMOKE ............................................................................. 94
LAV SMOKE DET FAIL ............................................................ 95
LG NO DISPATCH.................................................................... 96
LG NOSE DOOR OPEN............................................................ 96
LG WOW SYS FAIL.................................................................. 97
MFD 1 FAULT........................................................................... 97
MFD 2 FAULT........................................................................... 98

Page 4                                                                             May 10
NAVCOM 1 FAIL.......................................................................98
NAVCOM 2 FAIL.......................................................................99
NO LEFT FUEL QTY INDICATION ON EICAS .........................99
NO RIGHT FUEL QTY INDICATION ON EICAS .....................100
NO TOTAL FUEL QTY INDICATION ON EICAS ....................100
OBSERVER DAP PROBLEMS - DISPLAY,
VOLUME AND CONTROLS....................................................100
PACK 1 FAIL ..........................................................................101
PACK 2 FAIL ..........................................................................101
PFD 1 FAULT..........................................................................102
PFD 2 FAULT..........................................................................102
PILOT DAP PROBLEMS - DISPLAY, VOLUME AND
CONTROLS ............................................................................103
PITCH TRIM BKUP FL............................................................103
PITCH TRIM FAIL ...................................................................104
PITCH TRIM SW 1 FAIL..........................................................105
PITCH TRIM SW 2 FAIL..........................................................106
POTABLE WATER OR WASTE SYSTEM INOPERATIVE. ....107
PRESN AUTO FAIL ................................................................108
PRESN AUTO FAULT.............................................................109
PRESN MAN FAIL ..................................................................110
RADIOS TIMEOUT SHOWS ON THE MCDU 1
SCRATCHPAD........................................................................111
RADIOS TIMEOUT SHOWS ON THE MCDU 2
SCRATCHPAD........................................................................111
RALT 1 FAIL ...........................................................................112
RALT 2 FAIL ...........................................................................112
RAM AIR FAULT.....................................................................113
RAT FAIL ................................................................................114
RECIRC SMK DET FAIL .........................................................115
RECIRC SMOKE.....................................................................115
REFUEL PG TIMEOUT SHOWS ON THE MCDU 1
SCRATCHPAD........................................................................116
REFUEL PG TIMEOUT SHOWS ON THE MCDU 2
SCRATCHPAD........................................................................117
REMOTE CB TRIP ..................................................................118
RUDDER FAIL ........................................................................119
RUDDER FAULT.....................................................................119
SETUP PG TIMEOUT SHOWS ON THE MCDU 1
SCRATCHPAD........................................................................120

Page 5                                                                           May 10
SETUP PG TIMEOUT SHOWS ON THE MCDU 2
SCRATCHPAD ....................................................................... 120
SHAKER 1 FAIL ..................................................................... 121
SHAKER 2 FAIL ..................................................................... 122
SLAT FAIL .............................................................................. 123
SLAT LO RATE ...................................................................... 124
SLAT-FLAP LEVER DISAG.................................................... 125
SPDA FAIL ............................................................................. 125
SPDBRK LEVER DISAG ........................................................ 126
SPOILER FAULT .................................................................... 126
STEER FAIL ........................................................................... 126
STEER FAULT........................................................................ 127
TAT 1 FAIL ............................................................................. 127
TAT 2 FAIL ............................................................................. 127
TCAS FAIL ............................................................................. 128
TERRAIN FAIL ....................................................................... 129
TERRAIN NOT AVAILABLE................................................... 130
TEST PG TIMEOUT SHOWS ON THE MCDU 1
SCRATCHPAD ....................................................................... 131
TEST PG TIMEOUT SHOWS ON THE MCDU 2
SCRATCHPAD ....................................................................... 131
THRUST MGT TIMEOUT SHOWS ON THE MCDU 1
SCRATCHPAD ....................................................................... 132
THRUST MGT TIMEOUT SHOWS ON THE MCDU 2
SCRATCHPAD ....................................................................... 133
TRU 1 FAIL ............................................................................. 134
TRU 2 FAIL ............................................................................. 134
TRU ESS FAIL........................................................................ 135
UNCOMMANDED CHIME GENERATION – ALL
POSITIONS............................................................................. 135
UNCOMMANDED HF COMM TRANSMISSION – ALL
POSITIONS............................................................................. 136
UNCOMMANDED VHF COMM 1 TRANSMISSION - ALL
POSITIONS............................................................................. 136
UNCOMMANDED VHF COMM 2 TRANSMISSION - ALL
POSITIONS............................................................................. 137
UNCOMMANDED VHF COMM 3 TRANSMISSION - ALL
POSITIONS............................................................................. 137
WATER SYSTEM FAULT INDICATION ON AFT FLIGHT
ATTENDANT PANEL ............................................................. 138

Page 6                                                                           May 10
WINDSHEAR FAIL..................................................................139
WINDSHIELD 1 HTR FAIL ......................................................140
WINDSHIELD 2 HTR FAIL ......................................................140
WX FAIL MESSAGE ON THE MFD ........................................141
XPDR 1 FAIL...........................................................................142
XPDR 2 FAIL...........................................................................142




Page 7                                                                        May 10
INTRODUCTION

The purpose of this quick-reference guide is to provide information
to help users in the troubleshooting routine and elimination of some
faults detected on the aircraft through rest procedure.

This guide does not cover all the messages/faults that may be
detected on the aircraft. If the message/fault is not given in the
quick-reference guide, refer to the FAULT ISOLATION MANUAL.

The guide is organized in a three-column table, disposed as
follows:
      •  ATA column: Gives the ATA number for the related
         fault/message.
      •  MESSAGE/FAULT column: Gives the messages/faults,
         alphabetically ordered.
      •  MAINTENANCE ACTION column: Gives the corrective
         action (PROCEDURE). It may also inform the
         EFFECTIVITY and/or FAULT CONDITION.
      •  “IS THE FAULT REMOVED?” column: Gives the results
         of the procedure indicated in the Maintenance Action
         column.

When the reset procedure does not remove the message/fault,
refer to the FAULT ISOLATION MANUAL and do as follows:

     1.   On the “CAS MESSAGE LIST” or “OBSERVED FAULTS
          LIST”, in the front matter of the chapter, find the related
          FAULT CODE (FAULT CODE column).
     2.   Go to the “FAULT CODE INDEX”, and use the related
          FAULT CODE to do a check for correlated CMC
          messages:
               (a) If there are correlated CMC messages, in the
                     “CORRELATED MAINTENANCE MESSAGE
                     CODE” column, look for the correlated
                     maintenance messages on the CMC (AMM
                     TASK 45-45-00-970-803-A/200) to find the task
                     that you must do.



Page 8                                                     May 10
(b) If there are no correlated CMC messages go
                   directly to the task given in the “GO TO FIM
                   TASK” column.

If you have any doubts about how to use the FIM, refer to FAULT
ISOLATION MANUAL USAGE section.

Every effort has been made to ensure that the information
presented in the Quick-Reference Reset Guide is in accordance
with the Fault Isolation Manual. However, in the event of conflict
between them, the Fault Isolation Manual shall prevail.

NOTE: The Quick-Reference Reset Guide will be reissued on all
revisions.




Page 9                                                      May 10
MAU and SPDA RESET SAFETY PROCEDURES

          MAU - MAINTENANCE SAFETY PROCEDURES


    (1)    EFFECTIVITY: PRE-MOD SB 170-24-0017 (ON ACFT
           WITH SPDA BLOCK 6.1)

           If the aircraft is energized with APU and you need to do
           the reset of the MAU 1 and MAU 3, you must open the
           following SSPC to avoid the RAT deployment:

           •RAT DEPLOY-SPDA1 (CBMENU/CB BY SYS/ELEC)

    (2)    If the aircraft is energized with APU and you open the
           circuit breaker MAU 3 PWR 1, the APU will shutdown.

           NOTE: To avoid power interruption, you must energize
           the aircraft with an AC external power supply.

    (3)    Before you reset MAU 1 or MAU 3 power supplies, make
           sure that all switches on the HYDRAULIC CONTROL
           PANEL are set at the OFF position.

    (4)    If you do the MAU reset procedure with the engines in
           operation, engine related messages can show on the
           EICAS. We recommend that you stop the engines before
           the power-supply circuit-breaker cycling procedure.

    (5)    If it is necessary to open the MAU 1 and/or MAU 3 circuit
           breakers, the message “SPOILER FAULT” “and “A-I
           WING FAIL” will show on the EICAS.

    (6)    EFFECTIVITY: ON ACFT WITH ‘MAU2 PWR2 PRI’
           CIRCUIT BREAKER ON DC ESS BUS 2

           If it is necessary to open the MAU 2 PWR 2 PRI-RHCBP
           (DC ESS BUS 2) circuit breaker, the message “RAT
           FAIL” will show on the EICAS.


Page 10                                                    May 10
(7)   This procedure must be done to prevent the integrated
          pitot/static/AOA and TAT system heating in any of these
          situations:

          - If you open one of these MAU 1 circuit breakers:

          • MAU 1 PWR 2-LHCBP (DC ESS BUS 1)
          • MAU 1 PWR 3-LHCBP (DC BUS 1)

          - If you open one of these MAU 3 circuit breakers:

          • MAU 3 PWR 1-RHCBP (DC ESS BUS 2)
          • MAU 3 PWR 2-RHCBP (DC BUS 2)
          • MAU 3 CUST I/O 2A-RHCBP (DC ESS BUS 2)
          • MAU 3 CUST I/O 2B-RHCBP (DC BUS 2)

          WARNING: THE INTEGRATED PITOT/STATIC/AOA
          AND TAT HEATING SYSTEMS MUST BE OFF
          DURING MAINTENANCE. THIS IS BECAUSE
          SYSTEMS THAT INTERFACE WITH MAU 1, MAU 3
          AND SPDA 2 CAN CAUSE THE INTEGRATED
          PITOT/STATIC/AOAAND TAT SENSORS TO BECOME
          HOT. THESE SENSORS OPERATE AT HIGH
          TEMPERATURE. IF YOU TOUCH THEM, THEY WILL
          CAUSE INJURIES TO YOU.

          (a) Open this circuit breaker and put a circuit breaker ring
          and tag (inoperative - do not operate) on it:

          • PROBE 3 HEATER PWR-RHCBP (DC ESS BUS 3
          NAV).

          (b) On the MCDU, use the sequence in parentheses to
          open these SSPCs:

          •  TAT    1    HEAT-SPDA1             (CBMENU/CB         BY
          SYS/ICE/RAIN).
          •  TAT    2    HEAT-SPDA1             (CBMENU/CB         BY
          SYS/ICE/RAIN).


Page 11                                                      May 10
(c) Open these circuit breakers and put a circuit breaker
          ring and tag (inoperative - do not operate) on each one of
          them:

          • ADS PROBE 1 HTR-LICC (DC BUS 1)
          • ADS PROBE 2 HTR-LICC (DC BUS1)
          • ADS PROBE 4 HTR-RICC (DC BUS 2)


    (8)   To restore the systems affected by the MAU safety
          procedures to their initial condition, do as follows:

          (a) Remove the circuit breaker ring and tag (inoperative -
          do not operate) from this circuit breaker, and close it:

          • PROBE 3 HEATER PWR-RHCBP (DC ESS BUS 3
          NAV)

          (b) On the MCDU, use the sequence in parentheses to
          close these SSPCs:
          • TAT 1 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN)
          • TAT 2 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN)

          (c) Remove the circuit breaker ring and tag (inoperative -
          do not operate) from each of these circuit breakers, and
          close them:

          • ADS PROBE 1 HTR-LICC (DC BUS 1)
          • ADS PROBE 2 HTR-LICC (DC BUS1)
          • ADS PROBE 4 HTR-RICC (DC BUS 2)




Page 12                                                     May 10
SPDA - MAINTENANCE SAFETY PROCEDURES


    (1)    Before you reset SPDA 1 or SPDA 2 power supplies,
           make sure that all switches on the HYDRAULIC
           CONTROL PANEL are set at the OFF position.

    (2)    This procedure must be done to prevent the integrated
           pitot/static/AOA and TAT system heating if you open one
           of these SPDA 2 circuit breakers:

           • SPDA2 PWR SPLY 1-RICC (DC BUS 2)
           • SPDA2 PWR SPLY 3-EICC (DC ESS BUS 1)
           • SPDA2 PWR SPLY 2-RICC (DC ESS BUS 2)
           • SPDA2 PWR SPLY 4-LICC (DC GND SVC BUS)
           • SPDA2 I-O MOD 11-RICC (DC ESS BUS 2)

           WARNING: OBEY ALL THE SPDA SAFETY
           PROCEDURES. IF YOU DO NOT OBEY THESE
           PROCEDURES, INJURY TO PERSONS AND/OR
           DAMAGE TO EQUIPMENT CAN OCCUR.

           WARNING: THE INTEGRATED PITOT/STATIC/AOA
           AND TAT HEATING SYSTEMS MUST BE OFF DURING
           MAINTENANCE. THIS IS BECAUSE SYSTEMS THAT
           INTERFACE WITH MAU 1, MAU 3 AND SPDA 2 CAN
           CAUSE THE INTEGRATED PITOT/STATIC/AOA AND
           AT SENSORS TO BECOME HOT. THESE SENSORS
           OPERATE AT HIGH TEMPERATURE. IF YOU TOUCH
           THEM, THEY WILL CAUSE INJURIES TO YOU.

           (a) On the MCDU, use the sequence in parentheses to
           open these SSPCs:
           • TAT 1 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN)
           • TAT 2 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN)

           (b) Open these circuit breakers and put a circuit breaker
           ring and tag (inoperative - do not operate) on each one of
           them:


Page 13                                                    May 10
• PROBE 3 HEATER PWR-RHCBP (DC ESS BUS 3
    NAV)
        • ADS PROBE 1 HTR-LICC (DC BUS 1)
        • ADS PROBE 2 HTR-LICC (DC BUS1)
        • ADS PROBE 4 HTR-RICC (DC BUS 2)

    (3)   To restore the systems affected by the SPDA safety
          procedures, do as follows:

          (a) On the MCDU, use the sequence in parentheses to
          close these SSPCs:
          • TAT 1 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN)
          • TAT 2 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN)

          (b) Remove the circuit breaker ring and tag (inoperative -
          do not operate) from these circuit breakers, and close
          them:
          • PROBE 3 HEATER PWR-RHCBP (DC ESS BUS 3
          NAV)
          • ADS PROBE 1 HTR-LICC (DC BUS 1)
          • ADS PROBE 2 HTR-LICC (DC BUS1)
          • ADS PROBE 4 HTR-RICC (DC BUS 2)




Page 14                                                   May 10
General Information

The purpose of this section is to provide some standard procedures
and general information.

    (1)   The Quick-Reference Reset Guide must be used only
          with the aircraft on the ground.

    (2)   To perform the procedures that follow, refer to AMM
          TASK 45-45-00-970-805-A:
          • MAU module reset test;
          • Initiated BIT;
          • PBIT;
          • Clear Inhibit.

    (3)   To open and/or close a SSPC on the MCDU, refer to SDS
           34-61-00.




Page 15                                                  May 10
MESSAGE /                                                                                IS THE FAULT
ATA                                   MAINTENANCE ACTION                                        REMOVED?
       FAULT




                  EFF: [ON ACFT WITH CMF]

                  PROCEDURE:
                                                                                        Yes.
                  CAUTION: MAKE SURE THAT THE INTEGRATED
                                                                                        FIM TASK 23-24-00-810-
                  PITOT/STATIC/AOA SENSORS, TAT SENSORS, ICE
                                                                                        868-A
                  DETECTORS, AND STATIC PORT HAVE NO COVERS ON THEM
      ACARS
23                BEFORE YOU DO THE MAINTENANCE PROCEDURE. THESE
      FROZEN                                                                            No.
                  COMPONENTS CAN BECOME HOT DURING THE
                                                                                        Refer to the correspondent
                  MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO
                                                                                        chapter of the FIM for
                  THEM WILL OCCUR IF YOU DO NOT REMOVE THE COVERS.
                                                                                        troubleshooting.
                  Open this circuit breaker and, after approximately 5 seconds, close
                  it:
                  • MAU 3 PWR 2-RHCBP (DC BUS 2)




May 10                                                                                                 Page 16
MESSAGE /                                                                             IS THE FAULT
ATA                                    MAINTENANCE ACTION                                    REMOVED?
       FAULT




                                                                                     Yes.
                                                                                     FIM TASK 34-15-00-810-
                   Open these circuit breakers and, after approximately 5 seconds,   825-A
                   close them:
34    ADS 1 FAIL   • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1 NAV)                          No.
                   • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1 NAV)                         Refer to the correspondent
                                                                                     chapter of the FIM for
                                                                                     troubleshooting.




                                                                                     Yes.
                   FAULT CONDITION: During power-up                                  FIM TASK 34-15-00-810-
                                                                                     825-A
      ADS 1 HTR    PROCEDURE: Open these circuit breakers and, after 30 seconds,
30
        FAIL       close them:                                                       No.
                   • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1/NAV)                          Refer to the correspondent
                   • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1/NAV)                         chapter of the FIM for
                                                                                     troubleshooting.




May 10                                                                                              Page 17
MESSAGE /                                                                           IS THE FAULT
ATA                                   MAINTENANCE ACTION                                   REMOVED?
       FAULT
                                                                                   Yes.
                   FAULT CONDITION: During power-up                                FIM TASK 34-15-00-810-
                                                                                   825-A
      ADS 1 HTR    PROCEDURE: Open these circuit breakers and, after 30 seconds,
30
       FAULT       close them:                                                     No.
                   • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1/NAV)                        Refer to the correspondent
                   • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1/NAV)                       chapter of the FIM for
                                                                                   troubleshooting.
                   EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                   BREAKER ON DC ESS BUS 2]

                   PROCEDURE: Open these circuit breakers and, after
                   approximately 5 seconds, close them:
                   • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)
                                                                                   Yes.
                   • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV)
                                                                                   FIM TASK 34-15-00-810-
                   • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV)
                                                                                   827-A
                   • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV)
34    ADS 2 FAIL                                                                   No.
                   EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                                                                                   Refer to the correspondent
                   BREAKER ON DC ESS BUS 3]
                                                                                   chapter of the FIM for
                                                                                   troubleshooting.
                   PROCEDURE: Open these circuit breakers and, after
                   approximately 5 seconds, close them:
                   • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)
                   • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV)
                   • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV)
                   • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV)
May 10                                                                                            Page 18
MESSAGE /                                                                          IS THE FAULT
ATA                                  MAINTENANCE ACTION                                   REMOVED?
       FAULT


                  FAULT CONDITION: During power-up

                  EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                  BREAKER ON DC ESS BUS 2]

                  PROCEDURE: Open these circuit breakers and, after 30 seconds,
                  close them:
                  • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV)
                                                                                  Yes.
                  • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2/NAV)
                                                                                  FIM TASK 34-15-00-810-
                  • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV)
                                                                                  827-A
                  • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV)
      ADS 2 HTR
30
        FAIL                                                                      No.
                  EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                                                                                  Refer to the correspondent
                  BREAKER ON DC ESS BUS 3]
                                                                                  chapter of the FIM for
                  190 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                                                                                  troubleshooting.
                  BREAKER ON DC ESS BUS 3]

                  PROCEDURE: Open these circuit breakers and, after 30 seconds,
                  close them:
                  • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV)
                  • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3/NAV)
                  • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV)
                  • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV)



May 10                                                                                           Page 19
MESSAGE /                                                                          IS THE FAULT
ATA                                  MAINTENANCE ACTION                                   REMOVED?
       FAULT




                  FAULT CONDITION: During power-up

                  EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                  BREAKER ON DC ESS BUS 2]
                  PROCEDURE: Open these circuit breakers and, after 30 seconds,   Yes.
                  close them:                                                     FIM TASK 34-15-00-810-
                  - ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV)                       827-A
      ADS 2 HTR   - ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2/NAV)
30
       FAULT      - ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV)                           No.
                  - ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV)                  Refer to the correspondent
                                                                                  chapter of the FIM for
                  EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT            troubleshooting.
                  BREAKER ON DC ESS BUS 3]
                  190 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                  BREAKER ON DC ESS BUS 3]
                  PROCEDURE: Open these circuit breakers and, after 30 seconds,
                  close them:
                  - ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV)
                  - ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3/NAV)
                  - ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV)
                  - ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV)

May 10                                                                                           Page 20
MESSAGE /                                                                           IS THE FAULT
ATA                                   MAINTENANCE ACTION                                   REMOVED?
       FAULT


                   FAULT CONDITION: During power-up

                   EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                   BREAKER ON DC ESS BUS 2]

                   PROCEDURE: Open these circuit breakers and, after 30 seconds,
                   close them:
                   • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV)
                                                                                   Yes.
                   • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2/NAV)
                                                                                   FIM TASK 34-15-00-810-
                   • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV)
                                                                                   827-A
                   • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV)
30    ADS 3 FAIL                                                                   No.
                   EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                                                                                   Refer to the correspondent
                   BREAKER ON DC ESS BUS 3]
                                                                                   chapter of the FIM for
                   190 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                                                                                   troubleshooting.
                   BREAKER ON DC ESS BUS 3]

                   PROCEDURE: Open these circuit breakers and, after 30 seconds,
                   close them:
                   • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV)
                   • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3/NAV)
                   • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV)
                   • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV)



May 10                                                                                            Page 21
MESSAGE /                                                               IS THE FAULT
ATA                                 MAINTENANCE ACTION                         REMOVED?
       FAULT




                   EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                   BREAKER ON DC ESS BUS 2]

                   PROCEDURE: Open these circuit breakers and, after
                   approximately 5 seconds, close them:
                   • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)
                                                                       Yes.
                   • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV)
                                                                       FIM TASK 34-15-00-810-
                   • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV)
                                                                       811-A
                   • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV)
34    ADS 3 FAIL                                                       No.
                   EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                                                                       Refer to the correspondent
                   BREAKER ON DC ESS BUS 3]
                                                                       chapter of the FIM for
                                                                       troubleshooting.
                   PROCEDURE: Open these circuit breakers and, after
                   approximately 5 seconds, close them:
                   • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)
                   • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV)
                   • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV)
                   • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV)




May 10                                                                                Page 22
MESSAGE /                                                              IS THE FAULT
ATA                                MAINTENANCE ACTION                         REMOVED?
       FAULT




                  EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                  BREAKER ON DC ESS BUS 2]

                  PROCEDURE: Open these circuit breakers and, after
                  approximately 5 seconds, close them:
                  • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV)
                                                                      Yes.
                  • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV)
                                                                      FIM TASK 34-15-00-810-
                  • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)
        ADS 3                                                         833-A
                  • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV)
34    SLIPCOMP                                                        No.
         FAIL     EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                                                                      Refer to the correspondent
                  BREAKER ON DC ESS BUS 3]
                                                                      chapter of the FIM for
                                                                      troubleshooting.
                  PROCEDURE: Open these circuit breakers and, after
                  approximately 5 seconds, close them:
                  • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV)
                  • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV)
                  • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)
                  • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV)




May 10                                                                               Page 23
MESSAGE /                                                                          IS THE FAULT
ATA                                  MAINTENANCE ACTION                                   REMOVED?
       FAULT


                  FAULT CONDITION: During power-up

                  EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                  BREAKER ON DC ESS BUS 2]

                  PROCEDURE: Open these circuit breakers and, after 30 seconds,
                  close them:
                  • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV)
                                                                                  Yes.
                  • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2/NAV)
                                                                                  FIM TASK 34-15-00-810-
                  • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV)
                                                                                  827-A
                  • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV)
      ADS 4 HTR
30
        FAIL                                                                      No.
                  EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                                                                                  Refer to the correspondent
                  BREAKER ON DC ESS BUS 3]
                                                                                  chapter of the FIM for
                  190 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                                                                                  troubleshooting.
                  BREAKER ON DC ESS BUS 3]

                  PROCEDURE: Open these circuit breakers and, after 30 seconds,
                  close them:
                  • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV)
                  • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3/NAV)
                  • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV)
                  • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV)




May 10                                                                                           Page 24
MESSAGE /                                                              IS THE FAULT
ATA                                MAINTENANCE ACTION                         REMOVED?
       FAULT




                  EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                  BREAKER ON DC ESS BUS 2]

                  PROCEDURE: Open these circuit breakers and, after
                  approximately 5 seconds, close them:
                  • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV)
                                                                      Yes.
                  • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV)
                                                                      FIM TASK 34-15-00-810-
                  • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)
        ADS 4                                                         833-A
                  • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV)
34    SLIPCOMP                                                        No.
         FAIL     EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT
                                                                      Refer to the correspondent
                  BREAKER ON DC ESS BUS 3]
                                                                      chapter of the FIM for
                                                                      troubleshooting.
                  PROCEDURE: Open these circuit breakers and, after
                  approximately 5 seconds, close them:
                  • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV)
                  • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV)
                  • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)
                  • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV)




May 10                                                                               Page 25
MESSAGE /                                                                                     IS THE FAULT
ATA                                        MAINTENANCE ACTION                                          REMOVED?
         FAULT
                     EFF: [ON ACFT WITH PRIMUS EPIC LOAD UP TO 21.5]
                                                                                               Yes.
                     FAULT CONDITION 1: The CAS message shows from the moment                  FIM TASK 34-15-00-810-
                     in which the aircraft is at the gate until the takeoff. ADS 1 FAIL does   852-A
                     not show on the EICAS display.                                            No.
                     PROCEDURE: De-energize the aircraft and energize it again.                Refer to the correspondent
                                                                                               chapter of the FIM for
                                                                                               troubleshooting.

                  FAULT CONDITION 2: The CAS message shows as soon as the                      Yes.
                  aircraft lands.                                                              FIM TASK 34-15-00-810-
                  PROCEDURE: Open these circuit breakers and, after                            801-A
      ADS PROBE 1 approximately 5 seconds, close them:                                         No.
34
          FAIL    • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1 NAV)                                     Refer to the correspondent
                  • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1 NAV)                                    chapter of the FIM for
                                                                                               troubleshooting.


                                                                                               Yes.
                     EFF: [ON ACFT WITH PRIMUS EPIC LOAD 23.1 AND ON]                          FIM TASK 34-15-00-810-
                     FAULT CONDITION: The CAS message shows as soon as the                     801-A
                     aircraft lands.                                                           No.
                     PROCEDURE: Open these circuit breakers and, after                         Refer to the correspondent
                     approximately 5 seconds, close them:                                      chapter of the FIM for
                     • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1 NAV)                                  troubleshooting.
                     • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1 NAV)


May 10                                                                                                        Page 26
MESSAGE /                                                                                     IS THE FAULT
ATA                                        MAINTENANCE ACTION                                          REMOVED?
         FAULT
                     EFF: [ON ACFT WITH PRIMUS EPIC LOAD UP TO 21.5]
                                                                                               Yes.
                     FAULT CONDITION 1: The CAS message shows from the moment                  FIM TASK 34-15-00-810-
                     in which the aircraft is at the gate until the takeoff. ADS 1 FAIL does   853-A
                     not show on the EICAS display.                                            No.
                     PROCEDURE: De-energize the aircraft and energize it again.                Refer to the correspondent
                                                                                               chapter of the FIM for
                                                                                               troubleshooting.

                  FAULT CONDITION 2: The CAS message shows as soon as the                      Yes.
                  aircraft lands.                                                              FIM TASK 34-15-00-810-
                  PROCEDURE: Open these circuit breakers and, after                            801-A
      ADS PROBE 2 approximately 5 seconds, close them:                                         No.
34
          FAIL    • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1 NAV)                                     Refer to the correspondent
                  • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1 NAV)                                    chapter of the FIM for
                                                                                               troubleshooting.


                                                                                               Yes.
                     EFF: [ON ACFT WITH PRIMUS EPIC LOAD 23.1 AND ON]                          FIM TASK 34-15-00-810-
                     FAULT CONDITION: The CAS message shows as soon as the                     801-A
                     aircraft lands.                                                           No.
                     PROCEDURE: Open these circuit breakers and, after                         Refer to the correspondent
                     approximately 5 seconds, close them:                                      chapter of the FIM for
                     • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1 NAV)                                  troubleshooting.
                     • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1 NAV)


May 10                                                                                                        Page 27
MESSAGE /                                                                                                      IS THE FAULT
ATA                                            MAINTENANCE ACTION                                                      REMOVED?
        FAULT
                    EFF: [ON ACFT WITH PRIMUS EPIC LOAD UP TO 21.5]                                           Yes.
                    FAULT CONDITION 1: The CAS message shows from the moment in which the                     FIM TASK 34-15-00-810-854-A
                    aircraft is at the gate until the takeoff. ADS 2 FAIL and ADS 3 FAIL do not show on the   No.
                    EICAS display.                                                                            Refer to the correspondent
                    PROCEDURE: De-energize the aircraft and energize it again.                                chapter of the FIM for
                    FAULT CONDITION 2: The CAS message shows as soon as the aircraft lands.                   troubleshooting.
                    EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS
                    BUS 2]
                    PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close
                    them:
                    • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)
                    • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV)
                                                                                                              Yes.
                    EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS                          FIM TASK 34-15-00-810-806-A
                    BUS 3]                                                                                    No.
                    PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close          Refer to the correspondent
      ADS PROBE 3   them:                                                                                     chapter of the FIM for
34                  • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)                                                 troubleshooting.
          FAIL      • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV)

                    EFF: [ON ACFT WITH PRIMUS EPIC LOAD 23.1 AND ON]
                    FAULT CONDITION: The CAS message shows as soon as the aircraft lands.
                    EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS
                    BUS 2]
                    PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close
                    them:
                    • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)                                                 Yes.
                    • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV)                                            FIM TASK 34-15-00-810-806-A
                                                                                                              No.
                    EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS                          Refer to the correspondent
                    BUS 3]                                                                                    chapter of the FIM for
                    PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close          troubleshooting.
                    them:
                    • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV)
                    • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV)
May 10                                                                                                                         Page 28
MESSAGE /                                                                                    IS THE FAULT
ATA                                       MAINTENANCE ACTION                                          REMOVED?
         FAULT
                     EFF: [ON ACFT WITH PRIMUS EPIC LOAD UP TO 21.5]
                     FAULT CONDITION 1: The CAS message shows from the moment                 Yes.
                     in which the aircraft is at the gate until the takeoff. ADS 2 FAIL and   FIM TASK 34-15-00-810-
                     ADS 3 FAIL do not show on the EICAS display.                             855-A
                     PROCEDURE: De-energize the aircraft and energize it again.               No.
                                                                                              Refer to the correspondent
                                                                                              chapter of the FIM for
                                                                                              troubleshooting.
                  FAULT CONDITION 2: The CAS message shows as soon as the
                  aircraft lands.                                                             Yes.
                  PROCEDURE: Open these circuit breakers and, after                           FIM TASK 34-15-00-810-
                  approximately 5 seconds, close them:                                        806-A
      ADS PROBE 4 • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV)                                       No.
34
          FAIL    • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV)                              Refer to the correspondent
                                                                                              chapter of the FIM for
                                                                                              troubleshooting.

                     EFF: [ON ACFT WITH PRIMUS EPIC LOAD 23.1 AND ON]
                     FAULT CONDITION: The CAS message shows as soon as the                    Yes.
                     aircraft lands.                                                          FIM TASK 34-15-00-810-
                     PROCEDURE: Open these circuit breakers and, after                        806-A
                     approximately 5 seconds, close them:                                     No.
                     • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV)                                    Refer to the correspondent
                     • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV)                           chapter of the FIM for
                                                                                              troubleshooting.



May 10                                                                                                       Page 29
MESSAGE /                                                                                 IS THE FAULT
ATA                                     MAINTENANCE ACTION                                        REMOVED?
        FAULT




                   On the CMC, in the ACTIVE MAINTENANCE MESSAGES and
                   PRESENT LEG areas, look for any message correlated to the CAS
                   messages below that may be causing the AFCS FAULT.
                   • FLT CTRL NO DISPATCH
                   • FLT CTRL FAULT
                                                                                          Yes.
                   • FLAP LO RATE
                                                                                          FIM TASK 22-11-00-810-
                   • SLAT LO RATE
                                                                                          815-A
                   • ADS PROBE 1 FAIL
22    AFCS FAULT   • ADS PROBE 2 FAIL
                                                                                          No.
                   • ADS PROBE 3 FAIL
                                                                                          Refer to the correspondent
                   • ADS PROBE 4 FAIL
                                                                                          chapter of the FIM for
                   • TAT 1 FAIL
                                                                                          troubleshooting.
                   • TAT 2 FAIL
                   • AP FAULT
                   • AFCS FAULT
                   Proceed accordingly. If there is not a correlated message, reset the
                   aircraft.




May 10                                                                                                   Page 30
MESSAGE /                                                                                 IS THE FAULT
ATA                                    MAINTENANCE ACTION                                        REMOVED?
       FAULT




                  FAULT CONDITION 1: "A-I ENG 1 FAULT" CAS message can
                  come into view approximately 30 seconds after landing, if the
                  respective bleed system remains off for 10 seconds during any flight
                  phase; OR
                                                                                         Yes.
                  FAULT CONDITION 2: Bleed System 1 or 2 is off and the cross
                                                                                         FIM TASK 30-21-00-810-
                  bleed valve is closed.
                                                                                         821-A
      A-I ENG 1
30                EFF: [EMBRAER 190 and 195]
       FAULT                                                                             No.
                                                                                         Refer to the correspondent
                  PROCEDURE: On the ICE PROTECTION control panel, unlatch
                                                                                         chapter of the FIM for
                  (off) the ENGINE 1 and ENGINE 2 switches (lights come on).
                                                                                         troubleshooting.
                  Note: After 10 seconds, "A-I SWITCH OFF (advisory)" message
                  shows on the EICAS.
                  On the ICE PROTECTION control panel, latch (on) the ENGINE 1
                  and ENGINE 2 switches (lights go off).
                  Note: "A-I SWITCH OFF (advisory)" message goes out of view.




May 10                                                                                                  Page 31
MESSAGE /                                                                                 IS THE FAULT
ATA                                    MAINTENANCE ACTION                                        REMOVED?
       FAULT




                  FAULT CONDITION 1: "A-I ENG 2 FAULT" CAS message can
                  come into view approximately 30 seconds after landing, if the
                  respective bleed system remains off for 10 seconds during any flight
                  phase; OR
                                                                                         Yes.
                  FAULT CONDITION 2: Bleed System 1 or 2 is off and the cross            FIM TASK 30-21-00-810-
                  bleed valve is closed.                                                 821-A
      A-I ENG 2
30
       FAULT      EFF: [EMBRAER 190 and 195]                                             No.
                                                                                         Refer to the correspondent
                  PROCEDURE: On the ICE PROTECTION control panel, unlatch                chapter of the FIM for
                  (off) the ENGINE 1 and ENGINE 2 switches (lights come on).             troubleshooting.
                  Note: After 10 seconds, "A-I SWITCH OFF (advisory)" message
                  shows on the EICAS. On the ICE PROTECTION control panel,
                  latch (on) the ENGINE 1 and ENGINE 2 switches (lights go off).
                  Note: "A-I SWITCH OFF (advisory)" message goes out of view.




May 10                                                                                                  Page 32
MESSAGE /                                                                                IS THE FAULT
ATA                                       MAINTENANCE ACTION                                     REMOVED?
        FAULT
                      FAULT CONDITION: "A-I WING FAIL" CAS message shows during
                      the BIT (Built-in Test)

                      PROCEDURE: On the overhead panel:
                      • On the ICE PROTECTION control panel, turn the TEST switch to
                      the WING position.
                      • Unlatch the WING switch (light comes on).
                      • After 10 seconds, "A-I SWITCH OFF (advisory)" message shows
                      on the EICAS.
                      • Latch the WING switch (light goes off).
                                                                                         Yes.
                      • "A-I SWITCH OFF (advisory)" message goes out of view. Wait for
                                                                                         FIM TASK 30-11-00-810-
                      60 seconds and verify
                                                                                         817-A
                       if message does not show again on the CAS.
30    A-I WING FAIL                                                                      No.
                      FAULT CONDITION:"A-I WING FAIL" CAS message shows on
                                                                                         Refer to the correspondent
                      EICAS with the letters
                                                                                         chapter of the FIM for
                      CAS MSG displayed inside a cutout box on both PFDs.
                                                                                         troubleshooting.
                      PROCEDURE: On the overhead panel:
                      • On the ICE PROTECTION control panel, turn the TEST switch to
                      the WING position.
                      • Unlatch the WING switch (light comes on).
                      • After 10 seconds, "A-I SWITCH OFF (advisory)" message shows
                      on the EICAS.
                      • Latch the WING switch (light goes off).
                      • "A-I SWITCH OFF (advisory)" message goes out of view. Wait for
                      60 seconds and verify if message does not show again on the CAS

May 10                                                                                                  Page 33
MESSAGE /                                                                                     IS THE FAULT
ATA                                      MAINTENANCE ACTION                                          REMOVED?
       FAULT




      AMBER "X"    FAULT CONDITION: RECIRC switch is set to AUTO, batteries are              Yes.
      ON RECIRC    set to ON/AUTO, and the GPU is OFF for more than one minute               FIM TASK 21-24-00-810-
          FAN                                                                                805.
                   PROCEDURE: On the overhead panel, on the AIR
21    INDICATION   COND/PNEUMATIC control panel, set the RECIRC pushbutton to                No.
         (ECS      the unlatched (off) position. Wait 60 seconds and set it back to the      Refer to the correspondent
       SYNOPTIC    latched (auto) position. If it does not work, reset the aircraft (power   chapter of the FIM for
        PAGE)      down/up).                                                                 troubleshooting.




May 10                                                                                                      Page 34
MESSAGE /                                                                            IS THE FAULT
ATA                                   MAINTENANCE ACTION                                     REMOVED?
        FAULT


                                                                                    Yes.
                                                                                    FIM TASK 27-03-00-810-
                                                                                    89L-A
      AOA LIMIT    On the maintenance panel, make sure the FCS MAINT switch is in
27
        FAIL       the OFF position.                                                No.
                                                                                    Refer to the correspondent
                                                                                    chapter of the FIM for
                                                                                    troubleshooting.




                                                                                    Yes.
                                                                                    FIM TASK 22-11-00-810-
                                                                                    981-A
                   Make sure that the same ADS and IRS sources are not selected on
      APPR 2 NOT
22                 PFD 1 and PFD 2, the indications of RALT/IRS/ADS/FD are correct
        AVAIL      and there are no messages related to these systems on the EICAS.
                                                                                    No.
                                                                                    Refer to the correspondent
                                                                                    chapter of the FIM for
                                                                                    troubleshooting.




May 10                                                                                             Page 35
MESSAGE /                                                                              IS THE FAULT
ATA                                    MAINTENANCE ACTION                                     REMOVED?
       FAULT

                                                                                      Yes.
                  On the MCDU, open these SSPCs and close them after 10 seconds       FIM TASK 49-10-00-810-
                  to confirm that the failure has occurred:                           801-A
                  • APU FADEC (CB/CB BY SYS/APU)
49    APU FAIL    • ABC CMD PWR (CB/CB BY SYS/APU)                                    No.
                  • ASC CMD PWR (CB/CB BY SYS/APU)                                    Refer to the correspondent
                  Start the APU again.                                                chapter of the FIM for
                                                                                      troubleshooting.




                  FAULT CONDITION: The APU FUEL SOV FAIL CAS message
                                                                                      Yes.
                  was displayed during power-up and an APU start has not been
                                                                                      FIM TASK 28-22-00-810-
                  attempted
                                                                                      802-A
      APU FUEL
28                PROCEDURE: On the APU CONTROL panel set the EMER STOP
      SOV FAIL    pushbutton to the latched in (on) and latched out (off) position.
                                                                                      No.
                                                                                      Refer to the correspondent
                                                                                      chapter of the FIM for
                  NOTE: The resetting is valid only if the failure message occurred
                                                                                      troubleshooting.
                  during power-up.




May 10                                                                                               Page 36
MESSAGE /                                                                                                    IS THE FAULT
ATA                                           MAINTENANCE ACTION                                                    REMOVED?
       FAULT
                   FAULT CONDITION 1: "ENG TLA TRIM FAIL" message is active on the EICAS; AND

                   FAULT CONDITION 2: The following maintenance messages are active on the CMC:
                   22310005TA1 - ENGINE DATA [TRSA1] FAULT
                   22310005TA2 - ENGINE DATA [TRSA2] FAULT
                   22310023TA1 - FADEC1/FADEC2 [ATA1] WRG FAULT
                   22310023TA2 - FADEC1/FADEC2 [ATA2] WRG FAULT
                   22310079TA1 - LEFT FADEC [ATA1] FAULT
                   22310079TA2 - LEFT FADEC [ATA2] FAULT
                   22310080TA1 - RIGHT FADEC [ATA1] FAULT
                   22310080TA2 - RIGHT FADEC [ATA2] FAULT

                   NOTE: The recording of "RIGHT FADEC [ATxx] FAULT" or "LEFT FADEC [ATxx] FAULT"
                   maintenance message on the CMC depends on the faulty FADEC. The left FADEC refers to     Yes.
                   engine 1 and the right FADEC refers to engine 2.                                         FIM TASK 22-31-00-810-
                   EFF: [ALL]                                                                               821-A
22       AT FAIL   PROCEDURE:                                                                               No.
                   On the CMC, use the sequence that follows to get access to the ENGINE 1 GENERAL
                   STATUS PAGE:                                                                             Refer to the correspondent
                   • 73 - ENGINE FUEL AND CONTROL                                                           chapter of the FIM for
                   • 21 - ENGINE FADEC 1A
                   • ENGINE 1 GENERAL STATUS PAGE                                                           troubleshooting.
                   If the CHANNEL IN CONTROL status is the same for both channels, go to the FIM TASK 22-
                   31-00-810-821-A.

                   On the CMC, use the sequence that follows to get access to the ENGINE 2 GENERAL
                   STATUS PAGE:
                   • 73 - ENGINE FUEL AND CONTROL
                   • 21 - ENGINE FADEC 2A
                   • ENGINE 2 GENERAL STATUS PAGE
                   If the CHANNEL IN CONTROL status is the same for both channels, go to the FIM TASK 22-
                   31-00-810-821-A.




May 10                                                                                                                     Page 37
MESSAGE /                                                                     IS THE FAULT
ATA                                   MAINTENANCE ACTION                              REMOVED?
        FAULT

                   On the CMC, use the sequence that follows to do the PROC
                   module 1 reset test:
                                                                              Yes.
                   • 31 - INDICATING/RECORDING SYSTEMS
                                                                              FIM TASK 45-45-00-810-
                   • 41 - PROC MODULE 1 (MAU 1 SLOT NIC 1)
                                                                              81B-A
                   • MAU1 PROC1 MODULE RESET TEST
      AURAL WRN
31
       SYS FAIL                                                               No.
                   On the CMC, use the sequence that follows to do the PROC
                                                                              Refer to the correspondent
                   module 4 reset test:
                                                                              chapter of the FIM for
                   • 31 - INDICATING/RECORDING SYSTEMS
                                                                              troubleshooting.
                   • 41 - PROC MODULE 4 (MAU 2 SLOT NIC 2)
                   • MAU2 PROC4 MODULE RESET TEST


                   On the CMC, use the sequence that follows to do the PROC
                   module 1 reset test:
                                                                              Yes.
                   • 31 - INDICATING/RECORDING SYSTEMS
                                                                              FIM TASK 45-45-00-810-
                   • 41 - PROC MODULE 1 (MAU 1 SLOT NIC 1)
                                                                              81B-A
                   • MAU1 PROC1 MODULE RESET TEST
      AURAL WRN
31
      SYS FAULT    On the CMC, use the sequence that follows to do the PROC
                                                                              No.
                                                                              Refer to the correspondent
                   module 4 reset test:
                                                                              chapter of the FIM for
                   • 31 - INDICATING/RECORDING SYSTEMS
                                                                              troubleshooting.
                   • 41 - PROC MODULE 4 (MAU 2 SLOT NIC 2)
                   • MAU2 PROC4 MODULE RESET TEST



May 10                                                                                       Page 38
MESSAGE /                                                                                          IS THE FAULT
ATA                                         MAINTENANCE ACTION                                             REMOVED?
        FAULT
                                                                                                   Yes.
                                                                                                   FIM TASK 32-41-00-810-
                                                                                                   809-A
      AUTOBRAKE     On the CMC (System Diagnostics/ 32 - Landing Gear), run the
32
         FAIL       RESET TEST for AUTOBRAKE MODULE.                                               No.
                                                                                                   Refer to the correspondent
                                                                                                   chapter of the FIM for
                                                                                                   troubleshooting.
                    CAUTION: MAKE SURE THAT THE INTEGRATED PITOT/STATIC/AOA
                    SENSORS, TAT SENSORS, ICE DETECTORS AND STATIC PORT HAVE
                    NO COVERS ON THEM BEFORE YOU DO THE MAINTENANCE
                    PROCEDURE. THESE COMPONENTS CAN BECOME HOT DURING THE
                    MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO THEM WILL
                    OCCUR IF YOU DO NOT REMOVE THE COVERS.
                                                                                                   Yes.
                    Open these circuit breakers and, after approximately 5 seconds, close them:    FIM TASK 31-42-00-810-
                    NOTE: If power is removed from the CMC module for more than 10 seconds,        808-A
      AVNX MAU 1A   the CMC module will start its shutdown procedure. When power is supplied to
31                  the CMC module again, it will start its power-up procedure. The full process
         FAIL       takes approximately 5 minutes.                                                 No.
                    • MAU 1 PWR 1-LHCBP (DC ESS BUS 1)                                             Refer to the correspondent
                    • MAU 1 PWR 2-LHCBP (DC ESS BUS 1)                                             chapter of the FIM for
                    • MAU 1 PWR 3-LHCBP (DC BUS 1)                                                 troubleshooting.
                    On the CMC, use the sequence that follows to do the MAU 1 NIC module 1
                    reset test:
                    • 31 - INDICATING/RECORDING SYSTEMS
                    • 41 - MAU 1 NIC 1
                    • MAU1_NIC1 MODULE RESET TEST


May 10                                                                                                            Page 39
MESSAGE /                                                                                IS THE FAULT
ATA                                        MAINTENANCE ACTION                                     REMOVED?
         FAULT


                        CAUTION: MAKE SURE THAT THE INTEGRATED
                        PITOT/STATIC/AOA SENSORS, TAT SENSORS, ICE
                        DETECTORS AND STATIC PORT HAVE NO COVERS ON THEM
                        BEFORE YOU DO THE MAINTENANCE PROCEDURE. THESE
                        COMPONENTS CAN BECOME HOT DURING THE
                        MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO
                        THEM WILL OCCUR IF YOU DO NOT REMOVE THE COVERS.
                                                                                          Yes.
                  Open these circuit breakers and, after approximately 5 seconds,
                                                                                          FIM TASK 31-41-00-810-
                  close them:
                                                                                          88S-A
      AVNX MAU 1A NOTE: If power is removed from the CMC module for more than 10
31                seconds, the CMC module will start its shutdown procedure. When
         FAULT                                                                            No.
                  power is supplied to the CMC module again, it will start its power-up
                                                                                          Refer to the correspondent
                  procedure. The full process takes approximately 5 minutes.
                                                                                          chapter of the FIM for
                  • MAU 1 PWR 1-LHCBP (DC ESS BUS 1)
                                                                                          troubleshooting.
                  • MAU 1 PWR 2-LHCBP (DC ESS BUS 1)
                  • MAU 1 PWR 3-LHCBP (DC BUS 1)

                        On the CMC, use the sequence that follows to do the MAU 1 NIC
                        module 1 reset test:
                        • 31 - INDICATING/RECORDING SYSTEMS
                        • 41 - MAU 1 NIC 1
                        • MAU1_NIC1 MODULE RESET TEST




May 10                                                                                                   Page 40
MESSAGE /                                                                                IS THE FAULT
ATA                                        MAINTENANCE ACTION                                     REMOVED?
         FAULT


                        CAUTION: MAKE SURE THAT THE INTEGRATED
                        PITOT/STATIC/AOA SENSORS, TAT SENSORS, ICE
                        DETECTORS AND STATIC PORT HAVE NO COVERS ON THEM
                        BEFORE YOU DO THE MAINTENANCE PROCEDURE. THESE
                        COMPONENTS CAN BECOME HOT DURING THE
                        MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO
                        THEM WILL OCCUR IF YOU DO NOT REMOVE THE COVERS.
                                                                                          Yes.
                  Open these circuit breakers and, after approximately 5 seconds,
                                                                                          FIM TASK 31-42-00-810-
                  close them:
                                                                                          809-A
      AVNX MAU 1B NOTE: If power is removed from the CMC module for more than 10
31                seconds, the CMC module will start its shutdown procedure. When
         FAIL                                                                             No.
                  power is supplied to the CMC module again, it will start its power-up
                                                                                          Refer to the correspondent
                  procedure. The full process takes approximately 5 minutes.
                                                                                          chapter of the FIM for
                  • MAU 1 PWR 1-LHCBP (DC ESS BUS 1)
                                                                                          troubleshooting.
                  • MAU 1 PWR 2-LHCBP (DC ESS BUS 1)
                  • MAU 1 PWR 3-LHCBP (DC BUS 1)

                        On the CMC, use the sequence that follows to do the MAU 1 NIC
                        module 1 reset test:
                        • 31 - INDICATING/RECORDING SYSTEMS
                        • 41 - MAU 1 NIC 2
                        • MAU1_NIC2 MODULE RESET TEST




May 10                                                                                                   Page 41
MESSAGE /                                                                                IS THE FAULT
ATA                                        MAINTENANCE ACTION                                     REMOVED?
         FAULT


                        CAUTION: MAKE SURE THAT THE INTEGRATED
                        PITOT/STATIC/AOA SENSORS, TAT SENSORS, ICE
                        DETECTORS AND STATIC PORT HAVE NO COVERS ON THEM
                        BEFORE YOU DO THE MAINTENANCE PROCEDURE. THESE
                        COMPONENTS CAN BECOME HOT DURING THE
                        MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO
                        THEM WILL OCCUR IF YOU DO NOT REMOVE THE COVERS.
                                                                                          Yes.
                  Open these circuit breakers and, after approximately 5 seconds,
                                                                                          FIM TASK 31-41-00-810-
                  close them:
                                                                                          88Y-A
      AVNX MAU 1B NOTE: If power is removed from the module for more than 10
31                seconds, the CMC module will start its shutdown procedure. When
         FAULT                                                                            No.
                  power is supplied to the CMC module again, it will start its power-up
                                                                                          Refer to the correspondent
                  procedure. The full process takes approximately 5 minutes.
                                                                                          chapter of the FIM for
                  • MAU 1 PWR 1-LHCBP (DC ESS BUS 1)
                                                                                          troubleshooting.
                  • MAU 1 PWR 2-LHCBP (DC ESS BUS 1)
                  • MAU 1 PWR 3-LHCBP (DC BUS 1)

                        On the CMC, use the sequence that follows to do the MAU 1 NIC
                        module 2 reset test:
                        • 31 - INDICATING/RECORDING SYSTEMS
                        • 41 - MAU 1 NIC 2
                        • MAU1_NIC2 MODULE RESET TEST




May 10                                                                                                   Page 42
MESSAGE /                                                                         IS THE FAULT
ATA                                      MAINTENANCE ACTION                                REMOVED?
         FAULT
                      EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON
                      DC BUS 2]

                      PROCEDURE: Open these circuit breakers and, after
                      approximately 5 seconds, close them:
                      • MAU 2 PWR 1-RHCBP (DC BUS 2)
                      • MAU 2 PWR 2 PRI-RHCBP (DC BUS 2)
                      • MAU 2 PWR 2 SEC-RHCBP (DC ESS BUS 2)
                                                                                   Yes.
                      EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON
                                                                                   FIM TASK 31-42-00-810-
                      DC ESS BUS 2]
                                                                                   810-A
      AVNX MAU 2A
31                PROCEDURE: Open these circuit breakers and, after
         FAIL                                                                      No.
                  approximately 5 seconds, close them:
                                                                                   Refer to the correspondent
                      • MAU 2 PWR 1-RHCBP (DC BUS 2)
                                                                                   chapter of the FIM for
                      • MAU 2 PWR 2 PRI-RHCBP (DC ESS BUS 2)
                                                                                   troubleshooting.
                      • MAU 2 PWR 2 SEC-RHCBP (DC BUS 2)

                      EFF: ALL

                      PROCEDURE: On the CMC, use the sequence that follows to do
                      the MAU 2 NIC module 3 reset test:
                      • 31 - INDICATING/RECORDING SYSTEMS
                      • 41 - MAU2 NIC 1
                      • MAU2_NIC3 MODULE RESET TEST


May 10                                                                                            Page 43
MESSAGE /                                                                         IS THE FAULT
ATA                                      MAINTENANCE ACTION                                REMOVED?
         FAULT
                      EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON
                      DC BUS 2]

                      PROCEDURE: Open these circuit breakers and, after
                      approximately 5 seconds, close them:
                      • MAU 2 PWR 1-RHCBP (DC BUS 2)
                      • MAU 2 PWR 2 PRI-RHCBP (DC BUS 2)
                      • MAU 2 PWR 2 SEC-RHCBP (DC ESS BUS 2)
                                                                                   Yes.
                      EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON
                                                                                   FIM TASK 31-41-00-810-
                      DC ESS BUS 2]
                                                                                   89F-A
      AVNX MAU 2A
31                PROCEDURE: Open these circuit breakers and, after
         FAULT                                                                     No.
                  approximately 5 seconds, close them:
                                                                                   Refer to the correspondent
                      • MAU 2 PWR 1-RHCBP (DC BUS 2)
                                                                                   chapter of the FIM for
                      • MAU 2 PWR 2 PRI-RHCBP (DC ESS BUS 2)
                                                                                   troubleshooting.
                      • MAU 2 PWR 2 SEC-RHCBP (DC BUS 2)

                      EFF: ALL

                      PROCEDURE: On the CMC, use the sequence that follows to do
                      the MAU 2 NIC module 3 reset test:
                      • 31 - INDICATING/RECORDING SYSTEMS
                      • 41 - MAU 2 NIC 1
                      • MAU2_NIC3 MODULE RESET TEST


May 10                                                                                            Page 44
MESSAGE /                                                                         IS THE FAULT
ATA                                      MAINTENANCE ACTION                                REMOVED?
         FAULT
                      EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON
                      DC BUS 2]

                      PROCEDURE: Open these circuit breakers and, after
                      approximately 5 seconds, close them:
                      • MAU 2 PWR 1-RHCBP (DC BUS 2)
                      • MAU 2 PWR 2 PRI-RHCBP (DC BUS 2)
                      • MAU 2 PWR 2 SEC-RHCBP (DC ESS BUS 2)
                                                                                   Yes.
                      EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON
                                                                                   FIM TASK 31-42-00-810-
                      DC ESS BUS 2]
                                                                                   811-A
      AVNX MAU 2B
31                PROCEDURE: Open these circuit breakers and, after
         FAIL                                                                      No.
                  approximately 5 seconds, close them:
                                                                                   Refer to the correspondent
                      • MAU 2 PWR 1-RHCBP (DC BUS 2)
                                                                                   chapter of the FIM for
                      • MAU 2 PWR 2 PRI-RHCBP (DC ESS BUS 2)
                                                                                   troubleshooting.
                      • MAU 2 PWR 2 SEC-RHCBP (DC BUS 2)

                      EFF: ALL

                      PROCEDURE: On the CMC, use the sequence that follows to do
                      the MAU 2 NIC module 4 reset test:
                      • 31 - INDICATING/RECORDING SYSTEMS
                      • 41 - MAU 2 NIC 2
                      • MAU2_NIC4 MODULE RESET TEST


May 10                                                                                            Page 45
MESSAGE /                                                                         IS THE FAULT
ATA                                      MAINTENANCE ACTION                                REMOVED?
         FAULT
                      EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON
                      DC BUS 2]

                      PROCEDURE: Open these circuit breakers and, after
                      approximately 5 seconds, close them:
                      • MAU 2 PWR 1-RHCBP (DC BUS 2)
                      • MAU 2 PWR 2 PRI-RHCBP (DC BUS 2)
                      • MAU 2 PWR 2 SEC-RHCBP (DC ESS BUS 2)
                                                                                   Yes.
                      EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON
                                                                                   FIM TASK 31-41-00-810-
                      DC ESS BUS 2]
                                                                                   89M-A
      AVNX MAU 2B
31                PROCEDURE: Open these circuit breakers and, after
         FAULT                                                                     No.
                  approximately 5 seconds, close them:
                                                                                   Refer to the correspondent
                      • MAU 2 PWR 1-RHCBP (DC BUS 2)
                                                                                   chapter of the FIM for
                      • MAU 2 PWR 2 PRI-RHCBP (DC ESS BUS 2)
                                                                                   troubleshooting.
                      • MAU 2 PWR 2 SEC-RHCBP (DC BUS 2)

                      EFF: ALL

                      PROCEDURE: On the CMC, use the sequence that follows to do
                      the MAU 2 NIC module 4 reset test:
                      • 31 - INDICATING/RECORDING SYSTEMS
                      • 41 - MAU 2 NIC 2
                      • MAU2_NIC4 MODULE RESET TEST


May 10                                                                                            Page 46
MESSAGE /                                                                             IS THE FAULT
ATA                                       MAINTENANCE ACTION                                   REMOVED?
         FAULT




                       CAUTION: MAKE SURE THAT THE INTEGRATED
                       PITOT/STATIC/AOA SENSORS, TAT SENSORS, ICE
                       DETECTORS AND STATIC PORT HAVE NO COVERS ON THEM
                       BEFORE YOU DO THE MAINTENANCE PROCEDURE. THESE
                       COMPONENTS CAN BECOME HOT DURING THE
                       MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO                   Yes.
                       THEM WILL OCCUR IF YOU DO NOT REMOVE THE COVERS.                FIM TASK 31-42-00-810-
                                                                                       812-A
      AVNX MAU 3A Open these circuit breakers and, after approximately 5 seconds,
31
         FAIL     close them:                                                          No.
                       • MAU 3 PWR 1-RHCBP (DC ESS BUS 2)                              Refer to the correspondent
                       • MAU 3 PWR 2-RHCBP (DC BUS 2)                                  chapter of the FIM for
                                                                                       troubleshooting.
                       On the CMC, use the sequence that follows to do the MAU 3 NIC
                       module 5 reset test:
                       • 31 - INDICATING/RECORDING SYSTEMS
                       • 41 - MAU 3 NIC 1
                       • MAU3 NIC5 MODULE RESET TEST




May 10                                                                                                Page 47
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10
Emb170 190 Qrrg Rev10

More Related Content

What's hot

Aircraft Finite Element Modelling for structure analysis using Altair Products
Aircraft Finite Element Modelling for structure analysis using Altair ProductsAircraft Finite Element Modelling for structure analysis using Altair Products
Aircraft Finite Element Modelling for structure analysis using Altair ProductsAltair
 
Airbus a320 aircraft operation manual
Airbus a320 aircraft operation manualAirbus a320 aircraft operation manual
Airbus a320 aircraft operation manualMusab Elamien
 
Caterpillar cat 938 f wheel loader (prefix 8sm) service repair manual (8sm000...
Caterpillar cat 938 f wheel loader (prefix 8sm) service repair manual (8sm000...Caterpillar cat 938 f wheel loader (prefix 8sm) service repair manual (8sm000...
Caterpillar cat 938 f wheel loader (prefix 8sm) service repair manual (8sm000...eudskkejedmm
 
T-X Requirements matrix
T-X Requirements matrixT-X Requirements matrix
T-X Requirements matrixNicolas Perron
 
The More Electric Aircraft Evolution
The More Electric Aircraft EvolutionThe More Electric Aircraft Evolution
The More Electric Aircraft EvolutionAstronics Corporation
 
Catálogo Velas NGK
Catálogo Velas NGKCatálogo Velas NGK
Catálogo Velas NGKfelipecorso
 
Dlscrib.com npr manual-y-diagrama-motor-isuzu-7294hk1trainingpdf
Dlscrib.com npr manual-y-diagrama-motor-isuzu-7294hk1trainingpdfDlscrib.com npr manual-y-diagrama-motor-isuzu-7294hk1trainingpdf
Dlscrib.com npr manual-y-diagrama-motor-isuzu-7294hk1trainingpdfLuis Capella Padilla
 
Aircraft Maintenance Records and Airworthiness Directives for General Aviation
Aircraft Maintenance Records and Airworthiness Directives for General AviationAircraft Maintenance Records and Airworthiness Directives for General Aviation
Aircraft Maintenance Records and Airworthiness Directives for General AviationFAA Safety Team Central Florida
 
Brakes
BrakesBrakes
Brakesitun96
 
Helicopter components
Helicopter componentsHelicopter components
Helicopter componentsabarget
 
V2500 Electronic Engine Control.pdf
V2500 Electronic Engine Control.pdfV2500 Electronic Engine Control.pdf
V2500 Electronic Engine Control.pdfSerranoSerrano7
 
Tecnam p2006 t systems
Tecnam p2006 t systemsTecnam p2006 t systems
Tecnam p2006 t systemsBrianYanowski
 
Team Spark Racing - FSAE Italy & SAE Supra 2015
Team Spark Racing - FSAE Italy & SAE Supra 2015Team Spark Racing - FSAE Italy & SAE Supra 2015
Team Spark Racing - FSAE Italy & SAE Supra 2015Dhamodharan V
 
JET ENGINE PPT BY SANDEEP YADAV
JET ENGINE PPT BY SANDEEP YADAVJET ENGINE PPT BY SANDEEP YADAV
JET ENGINE PPT BY SANDEEP YADAVSANDEEP YADAV
 
Audi A4 Fuel Pump Failure Causes and Symptoms
Audi A4 Fuel Pump Failure Causes and SymptomsAudi A4 Fuel Pump Failure Causes and Symptoms
Audi A4 Fuel Pump Failure Causes and SymptomsImport Car Center
 

What's hot (20)

rc plane design guide
rc plane design guiderc plane design guide
rc plane design guide
 
Aircraft Finite Element Modelling for structure analysis using Altair Products
Aircraft Finite Element Modelling for structure analysis using Altair ProductsAircraft Finite Element Modelling for structure analysis using Altair Products
Aircraft Finite Element Modelling for structure analysis using Altair Products
 
Airbus a320 aircraft operation manual
Airbus a320 aircraft operation manualAirbus a320 aircraft operation manual
Airbus a320 aircraft operation manual
 
Caterpillar cat 938 f wheel loader (prefix 8sm) service repair manual (8sm000...
Caterpillar cat 938 f wheel loader (prefix 8sm) service repair manual (8sm000...Caterpillar cat 938 f wheel loader (prefix 8sm) service repair manual (8sm000...
Caterpillar cat 938 f wheel loader (prefix 8sm) service repair manual (8sm000...
 
T-X Requirements matrix
T-X Requirements matrixT-X Requirements matrix
T-X Requirements matrix
 
The More Electric Aircraft Evolution
The More Electric Aircraft EvolutionThe More Electric Aircraft Evolution
The More Electric Aircraft Evolution
 
Diagramas atos
Diagramas atosDiagramas atos
Diagramas atos
 
Catálogo Velas NGK
Catálogo Velas NGKCatálogo Velas NGK
Catálogo Velas NGK
 
Dlscrib.com npr manual-y-diagrama-motor-isuzu-7294hk1trainingpdf
Dlscrib.com npr manual-y-diagrama-motor-isuzu-7294hk1trainingpdfDlscrib.com npr manual-y-diagrama-motor-isuzu-7294hk1trainingpdf
Dlscrib.com npr manual-y-diagrama-motor-isuzu-7294hk1trainingpdf
 
Aircraft Maintenance Records and Airworthiness Directives for General Aviation
Aircraft Maintenance Records and Airworthiness Directives for General AviationAircraft Maintenance Records and Airworthiness Directives for General Aviation
Aircraft Maintenance Records and Airworthiness Directives for General Aviation
 
Human Factor.pdf
Human Factor.pdfHuman Factor.pdf
Human Factor.pdf
 
Brakes
BrakesBrakes
Brakes
 
Helicopter components
Helicopter componentsHelicopter components
Helicopter components
 
V2500 Electronic Engine Control.pdf
V2500 Electronic Engine Control.pdfV2500 Electronic Engine Control.pdf
V2500 Electronic Engine Control.pdf
 
Tecnam p2006 t systems
Tecnam p2006 t systemsTecnam p2006 t systems
Tecnam p2006 t systems
 
Team Spark Racing - FSAE Italy & SAE Supra 2015
Team Spark Racing - FSAE Italy & SAE Supra 2015Team Spark Racing - FSAE Italy & SAE Supra 2015
Team Spark Racing - FSAE Italy & SAE Supra 2015
 
JET ENGINE PPT BY SANDEEP YADAV
JET ENGINE PPT BY SANDEEP YADAVJET ENGINE PPT BY SANDEEP YADAV
JET ENGINE PPT BY SANDEEP YADAV
 
Shaft Alignment and Whirling Vibration
Shaft Alignment and Whirling VibrationShaft Alignment and Whirling Vibration
Shaft Alignment and Whirling Vibration
 
Audi A4 Fuel Pump Failure Causes and Symptoms
Audi A4 Fuel Pump Failure Causes and SymptomsAudi A4 Fuel Pump Failure Causes and Symptoms
Audi A4 Fuel Pump Failure Causes and Symptoms
 
Fly By Wire
Fly By WireFly By Wire
Fly By Wire
 

Viewers also liked

Clipping Viste la Calle 18/11/11 @ IED Barcelona
Clipping Viste la Calle 18/11/11 @ IED BarcelonaClipping Viste la Calle 18/11/11 @ IED Barcelona
Clipping Viste la Calle 18/11/11 @ IED BarcelonaIED Barcelona
 
Change management quick guide
Change management quick guide Change management quick guide
Change management quick guide Maven
 
Arte Despertar: the first decade
Arte Despertar: the first decadeArte Despertar: the first decade
Arte Despertar: the first decadeArte Despertar
 
Health epitome presentation
Health epitome presentationHealth epitome presentation
Health epitome presentationnaveen_btpl
 
11. чумаченко ngenix-itv2011 1
11. чумаченко ngenix-itv2011 111. чумаченко ngenix-itv2011 1
11. чумаченко ngenix-itv2011 1Aleksey Naumkin
 
Learning about Geometry by Joe Gaymore
Learning about Geometry by Joe GaymoreLearning about Geometry by Joe Gaymore
Learning about Geometry by Joe GaymoreJoe Gaymore
 
6 Months Project Training in PHP
6 Months Project Training in PHP6 Months Project Training in PHP
6 Months Project Training in PHPTech Mentro
 
Psalm 145 – Praising the Lord in truth
Psalm 145 – Praising the Lord in truthPsalm 145 – Praising the Lord in truth
Psalm 145 – Praising the Lord in truthJon Juane
 
Learning about geometry by joe gaymore
Learning about geometry by joe gaymoreLearning about geometry by joe gaymore
Learning about geometry by joe gaymoreJoe Gaymore
 
Completing the puzzle: Development of SMEs and Crafts with WUSME and IUE Univ...
Completing the puzzle: Development of SMEs and Crafts with WUSME and IUE Univ...Completing the puzzle: Development of SMEs and Crafts with WUSME and IUE Univ...
Completing the puzzle: Development of SMEs and Crafts with WUSME and IUE Univ...Norbert Knoll von Dornhoff
 
Tameer friday special april 9th 2015
Tameer   friday special april 9th  2015Tameer   friday special april 9th  2015
Tameer friday special april 9th 2015Khurram Ahmad
 
Tameer monday 26 jan 2015
Tameer   monday 26 jan 2015Tameer   monday 26 jan 2015
Tameer monday 26 jan 2015Khurram Ahmad
 
נטיקה הדס מטס 201011
נטיקה הדס מטס 201011נטיקה הדס מטס 201011
נטיקה הדס מטס 201011Hadas Matas
 
Facebook, Twitter and All The Rest: What You Should Know and What You Should Do
Facebook, Twitter and All The Rest: What You Should Know and What You Should DoFacebook, Twitter and All The Rest: What You Should Know and What You Should Do
Facebook, Twitter and All The Rest: What You Should Know and What You Should DoJake Batsell
 

Viewers also liked (20)

Clipping Viste la Calle 18/11/11 @ IED Barcelona
Clipping Viste la Calle 18/11/11 @ IED BarcelonaClipping Viste la Calle 18/11/11 @ IED Barcelona
Clipping Viste la Calle 18/11/11 @ IED Barcelona
 
STC PMC Newsletter 2005-03
STC PMC Newsletter 2005-03STC PMC Newsletter 2005-03
STC PMC Newsletter 2005-03
 
Change management quick guide
Change management quick guide Change management quick guide
Change management quick guide
 
Arte Despertar: the first decade
Arte Despertar: the first decadeArte Despertar: the first decade
Arte Despertar: the first decade
 
LOGA State of the Industry: Houston, TX
LOGA State of the Industry: Houston, TXLOGA State of the Industry: Houston, TX
LOGA State of the Industry: Houston, TX
 
Health epitome presentation
Health epitome presentationHealth epitome presentation
Health epitome presentation
 
11. чумаченко ngenix-itv2011 1
11. чумаченко ngenix-itv2011 111. чумаченко ngenix-itv2011 1
11. чумаченко ngenix-itv2011 1
 
Learning about Geometry by Joe Gaymore
Learning about Geometry by Joe GaymoreLearning about Geometry by Joe Gaymore
Learning about Geometry by Joe Gaymore
 
Krtjp
KrtjpKrtjp
Krtjp
 
6 Months Project Training in PHP
6 Months Project Training in PHP6 Months Project Training in PHP
6 Months Project Training in PHP
 
Lafayette Rotary
Lafayette RotaryLafayette Rotary
Lafayette Rotary
 
Psalm 145 – Praising the Lord in truth
Psalm 145 – Praising the Lord in truthPsalm 145 – Praising the Lord in truth
Psalm 145 – Praising the Lord in truth
 
Learning about geometry by joe gaymore
Learning about geometry by joe gaymoreLearning about geometry by joe gaymore
Learning about geometry by joe gaymore
 
Completing the puzzle: Development of SMEs and Crafts with WUSME and IUE Univ...
Completing the puzzle: Development of SMEs and Crafts with WUSME and IUE Univ...Completing the puzzle: Development of SMEs and Crafts with WUSME and IUE Univ...
Completing the puzzle: Development of SMEs and Crafts with WUSME and IUE Univ...
 
Introducción a la geografía
Introducción a la geografíaIntroducción a la geografía
Introducción a la geografía
 
Tameer friday special april 9th 2015
Tameer   friday special april 9th  2015Tameer   friday special april 9th  2015
Tameer friday special april 9th 2015
 
Tameer monday 26 jan 2015
Tameer   monday 26 jan 2015Tameer   monday 26 jan 2015
Tameer monday 26 jan 2015
 
נטיקה הדס מטס 201011
נטיקה הדס מטס 201011נטיקה הדס מטס 201011
נטיקה הדס מטס 201011
 
INGLES I
INGLES IINGLES I
INGLES I
 
Facebook, Twitter and All The Rest: What You Should Know and What You Should Do
Facebook, Twitter and All The Rest: What You Should Know and What You Should DoFacebook, Twitter and All The Rest: What You Should Know and What You Should Do
Facebook, Twitter and All The Rest: What You Should Know and What You Should Do
 

Similar to Emb170 190 Qrrg Rev10

Case 570 mxt series 3 loader landscaper operator manual
Case 570 mxt series 3 loader landscaper operator manualCase 570 mxt series 3 loader landscaper operator manual
Case 570 mxt series 3 loader landscaper operator manualfjjskertefksmem
 
Case 570 mxt loader landscaper operator manual
Case 570 mxt loader landscaper operator manualCase 570 mxt loader landscaper operator manual
Case 570 mxt loader landscaper operator manualfujsefksemm
 
Case 570 mxt loader landscaper operator manual
Case 570 mxt loader landscaper operator manualCase 570 mxt loader landscaper operator manual
Case 570 mxt loader landscaper operator manualfjsekdemmd
 
B 65270 en-07
B 65270 en-07B 65270 en-07
B 65270 en-07mt7038
 
Toro groundsmaster 5900 service repair manual
Toro groundsmaster 5900 service repair manualToro groundsmaster 5900 service repair manual
Toro groundsmaster 5900 service repair manualfjjseksxckmdme
 
Toro groundsmaster 5900 service repair manual
Toro groundsmaster 5900 service repair manualToro groundsmaster 5900 service repair manual
Toro groundsmaster 5900 service repair manualdidkkkdmdmd
 

Similar to Emb170 190 Qrrg Rev10 (6)

Case 570 mxt series 3 loader landscaper operator manual
Case 570 mxt series 3 loader landscaper operator manualCase 570 mxt series 3 loader landscaper operator manual
Case 570 mxt series 3 loader landscaper operator manual
 
Case 570 mxt loader landscaper operator manual
Case 570 mxt loader landscaper operator manualCase 570 mxt loader landscaper operator manual
Case 570 mxt loader landscaper operator manual
 
Case 570 mxt loader landscaper operator manual
Case 570 mxt loader landscaper operator manualCase 570 mxt loader landscaper operator manual
Case 570 mxt loader landscaper operator manual
 
B 65270 en-07
B 65270 en-07B 65270 en-07
B 65270 en-07
 
Toro groundsmaster 5900 service repair manual
Toro groundsmaster 5900 service repair manualToro groundsmaster 5900 service repair manual
Toro groundsmaster 5900 service repair manual
 
Toro groundsmaster 5900 service repair manual
Toro groundsmaster 5900 service repair manualToro groundsmaster 5900 service repair manual
Toro groundsmaster 5900 service repair manual
 

Emb170 190 Qrrg Rev10

  • 1. QUICK-REFERENCE RESET GUIDE FOR REFERENCE USE ONLY The data contained herein is intended to assist troubleshooting only and is not a substitute for Embraer and/or operator’s manuals. Fault correcting maintenance and the aircraft’s “return to service” testing shall be accomplished in full accordance with proper Embraer and/or operator’s manuals. All inquires regarding this material should be addressed to: 170techpubs@embraer.com.br JANUARY 2006 REVISION 10 – May 2010 Copyright 2010 by EMBRAER - Empresa Brasileira de Aeronáutica S.A. All rights reserved. This document shall not be copied or reproduced, whether in whole or in part, in any form or by any means without the express written authorization of Embraer. The information, technical data, designs and drawings disclosed in this document are property information of Embraer or third parties and shall not be used or disclosed to any third party without permission of Embraer.
  • 2. TABLE OF CONTENTS INTRODUCTION ......................................................................... 8 MAU AND SPDA RESET SAFETY PROCEDURES ................. 10 GENERAL INFORMATION ....................................................... 15 ACARS FROZEN ...................................................................... 16 ADS 1 FAIL............................................................................... 17 ADS 1 HTR FAIL ...................................................................... 17 ADS 1 HTR FAULT................................................................... 18 ADS 2 FAIL............................................................................... 18 ADS 2 HTR FAIL ...................................................................... 19 ADS 2 HTR FAULT................................................................... 20 ADS 3 FAIL............................................................................... 21 ADS 3 FAIL............................................................................... 22 ADS 3 SLIPCOMP FAIL ........................................................... 23 ADS 4 HTR FAIL ...................................................................... 24 ADS 4 SLIPCOMP FAIL ........................................................... 25 ADS PROBE 1 FAIL ................................................................. 26 ADS PROBE 2 FAIL ................................................................. 27 ADS PROBE 3 FAIL ................................................................. 28 ADS PROBE 4 FAIL ................................................................. 29 AFCS FAULT............................................................................ 30 A-I ENG 1 FAULT ..................................................................... 31 A-I ENG 2 FAULT ..................................................................... 32 A-I WING FAIL.......................................................................... 33 AMBER "X" ON RECIRC FAN INDICATION (ECS SYNOPTIC PAGE) .......................................................... 34 AOA LIMIT FAIL ....................................................................... 35 APPR 2 NOT AVAIL ................................................................. 35 APU FAIL.................................................................................. 36 APU FUEL SOV FAIL ............................................................... 36 AT FAIL .................................................................................... 37 AURAL WRN SYS FAIL ........................................................... 38 AURAL WRN SYS FAULT........................................................ 38 AUTOBRAKE FAIL................................................................... 39 AVNX MAU 1A FAIL ................................................................. 39 AVNX MAU 1A FAULT ............................................................. 40 AVNX MAU 1B FAIL ................................................................. 41 AVNX MAU 1B FAULT ............................................................. 42 AVNX MAU 2A FAIL ................................................................. 43 Page 2 May 10
  • 3. AVNX MAU 2A FAULT .............................................................44 AVNX MAU 2B FAIL .................................................................45 AVNX MAU 2B FAULT .............................................................46 AVNX MAU 3A FAIL .................................................................47 AVNX MAU 3A FAULT .............................................................48 AVNX MAU 3B FAIL .................................................................49 AVNX MAU 3B FAULT .............................................................50 BLEED 1 FAIL...........................................................................51 BLEED 1 OFF ...........................................................................52 BLEED 2 FAIL...........................................................................53 BLEED 2 OFF ...........................................................................54 BRK CONTROL FAULT............................................................55 BRK LH FAULT ........................................................................55 BRK LH FAULT ........................................................................56 CAS MSG INDICATION ON PFD ..............................................56 CENTER EBAY FANS FAIL......................................................57 CHIMES NOT AVAILABLE - ALL POSITIONS .........................58 CMF 1 FAIL...............................................................................58 "CMC IN AIR" OR "CMC CONNECTION FAILED" MESSAGES ON CMC SCREEN ...............................................59 COPILOT DAP PROBLEMS - DISPLAY, VOLUME AND CONTROLS ..............................................................................60 CVR AFT FAIL ..........................................................................60 CVR FWD FAIL .........................................................................61 DATALINK TIMEOUT SHOWS ON THE MCDU 1 SCRATCHPAD..........................................................................61 DATALINK TIMEOUT SHOWS ON THE MCDU 2 SCRATCHPAD..........................................................................62 EICAS FAULT ...........................................................................62 ELEVATOR FAULT...................................................................63 ELEVATOR LH FAIL.................................................................63 ELEVATOR RH FAIL ................................................................64 ENG 1 FADEC FAULT ..............................................................65 ENG 1 FUEL SW FAIL .............................................................66 ENG 2 FADEC FAULT ..............................................................67 ENG 2 FUEL SW FAIL .............................................................68 ENG TLA TRIM FAIL ................................................................69 FDR AFT FAIL ..........................................................................70 FDR FWD FAIL .........................................................................70 FLAP FAIL ................................................................................71 Page 3 May 10
  • 4. FLAP LO RATE ........................................................................ 72 FLT CTRL BIT EXPIRED .......................................................... 73 FLT CTRL FAULT..................................................................... 74 FLT CTRL NO DISPATCH ........................................................ 75 FLT CTRL NO DISPATCH/FLT CTRL FAULT/FLT CTRL BIT EXPIRED, AUTO CONFIG TRIM FAIL (ALTERNATE PROCEDURE) .......................................................................... 76 FMS 1 FAIL............................................................................... 77 FMS 2 FAIL............................................................................... 78 FMS1 TIMEOUT SHOWS ON THE MCDU 1 SCRATCHPAD ......................................................................... 79 FMS1-2 TIMEOUT SHOWS ON THE MCDU 1 SCRATCHPAD ......................................................................... 80 FMS1-2 TIMEOUT SHOWS ON THE MCDU 2 SCRATCHPAD ......................................................................... 81 FMS2 TIMEOUT SHOWS ON THE MCDU 2 SCRATCHPAD ......................................................................... 82 FUEL DC PUMP FAIL............................................................... 83 FUEL EQUAL-XFEED OPEN.................................................... 83 FWD EBAY FANS FAIL............................................................ 84 GND PROX FAIL ...................................................................... 85 GROUND SPOILERS FAIL....................................................... 86 HUD 1 FAIL .............................................................................. 86 HUD 2 FAIL .............................................................................. 87 HUD FAIL ................................................................................. 88 ICE DETECTOR 1 FAIL ............................................................ 89 ICE DETECTOR 2 FAIL ............................................................ 90 INPH AUDIO (BETWEEN DAPS) - NOISY OR NOT AVAILABLE ............................................................... 91 INVERTER FAIL ....................................................................... 91 IRS 1 FAIL ................................................................................ 92 IRS 2 FAIL ................................................................................ 92 IRS PRES POS INVALID .......................................................... 93 LAV SMOKE ............................................................................. 94 LAV SMOKE DET FAIL ............................................................ 95 LG NO DISPATCH.................................................................... 96 LG NOSE DOOR OPEN............................................................ 96 LG WOW SYS FAIL.................................................................. 97 MFD 1 FAULT........................................................................... 97 MFD 2 FAULT........................................................................... 98 Page 4 May 10
  • 5. NAVCOM 1 FAIL.......................................................................98 NAVCOM 2 FAIL.......................................................................99 NO LEFT FUEL QTY INDICATION ON EICAS .........................99 NO RIGHT FUEL QTY INDICATION ON EICAS .....................100 NO TOTAL FUEL QTY INDICATION ON EICAS ....................100 OBSERVER DAP PROBLEMS - DISPLAY, VOLUME AND CONTROLS....................................................100 PACK 1 FAIL ..........................................................................101 PACK 2 FAIL ..........................................................................101 PFD 1 FAULT..........................................................................102 PFD 2 FAULT..........................................................................102 PILOT DAP PROBLEMS - DISPLAY, VOLUME AND CONTROLS ............................................................................103 PITCH TRIM BKUP FL............................................................103 PITCH TRIM FAIL ...................................................................104 PITCH TRIM SW 1 FAIL..........................................................105 PITCH TRIM SW 2 FAIL..........................................................106 POTABLE WATER OR WASTE SYSTEM INOPERATIVE. ....107 PRESN AUTO FAIL ................................................................108 PRESN AUTO FAULT.............................................................109 PRESN MAN FAIL ..................................................................110 RADIOS TIMEOUT SHOWS ON THE MCDU 1 SCRATCHPAD........................................................................111 RADIOS TIMEOUT SHOWS ON THE MCDU 2 SCRATCHPAD........................................................................111 RALT 1 FAIL ...........................................................................112 RALT 2 FAIL ...........................................................................112 RAM AIR FAULT.....................................................................113 RAT FAIL ................................................................................114 RECIRC SMK DET FAIL .........................................................115 RECIRC SMOKE.....................................................................115 REFUEL PG TIMEOUT SHOWS ON THE MCDU 1 SCRATCHPAD........................................................................116 REFUEL PG TIMEOUT SHOWS ON THE MCDU 2 SCRATCHPAD........................................................................117 REMOTE CB TRIP ..................................................................118 RUDDER FAIL ........................................................................119 RUDDER FAULT.....................................................................119 SETUP PG TIMEOUT SHOWS ON THE MCDU 1 SCRATCHPAD........................................................................120 Page 5 May 10
  • 6. SETUP PG TIMEOUT SHOWS ON THE MCDU 2 SCRATCHPAD ....................................................................... 120 SHAKER 1 FAIL ..................................................................... 121 SHAKER 2 FAIL ..................................................................... 122 SLAT FAIL .............................................................................. 123 SLAT LO RATE ...................................................................... 124 SLAT-FLAP LEVER DISAG.................................................... 125 SPDA FAIL ............................................................................. 125 SPDBRK LEVER DISAG ........................................................ 126 SPOILER FAULT .................................................................... 126 STEER FAIL ........................................................................... 126 STEER FAULT........................................................................ 127 TAT 1 FAIL ............................................................................. 127 TAT 2 FAIL ............................................................................. 127 TCAS FAIL ............................................................................. 128 TERRAIN FAIL ....................................................................... 129 TERRAIN NOT AVAILABLE................................................... 130 TEST PG TIMEOUT SHOWS ON THE MCDU 1 SCRATCHPAD ....................................................................... 131 TEST PG TIMEOUT SHOWS ON THE MCDU 2 SCRATCHPAD ....................................................................... 131 THRUST MGT TIMEOUT SHOWS ON THE MCDU 1 SCRATCHPAD ....................................................................... 132 THRUST MGT TIMEOUT SHOWS ON THE MCDU 2 SCRATCHPAD ....................................................................... 133 TRU 1 FAIL ............................................................................. 134 TRU 2 FAIL ............................................................................. 134 TRU ESS FAIL........................................................................ 135 UNCOMMANDED CHIME GENERATION – ALL POSITIONS............................................................................. 135 UNCOMMANDED HF COMM TRANSMISSION – ALL POSITIONS............................................................................. 136 UNCOMMANDED VHF COMM 1 TRANSMISSION - ALL POSITIONS............................................................................. 136 UNCOMMANDED VHF COMM 2 TRANSMISSION - ALL POSITIONS............................................................................. 137 UNCOMMANDED VHF COMM 3 TRANSMISSION - ALL POSITIONS............................................................................. 137 WATER SYSTEM FAULT INDICATION ON AFT FLIGHT ATTENDANT PANEL ............................................................. 138 Page 6 May 10
  • 7. WINDSHEAR FAIL..................................................................139 WINDSHIELD 1 HTR FAIL ......................................................140 WINDSHIELD 2 HTR FAIL ......................................................140 WX FAIL MESSAGE ON THE MFD ........................................141 XPDR 1 FAIL...........................................................................142 XPDR 2 FAIL...........................................................................142 Page 7 May 10
  • 8. INTRODUCTION The purpose of this quick-reference guide is to provide information to help users in the troubleshooting routine and elimination of some faults detected on the aircraft through rest procedure. This guide does not cover all the messages/faults that may be detected on the aircraft. If the message/fault is not given in the quick-reference guide, refer to the FAULT ISOLATION MANUAL. The guide is organized in a three-column table, disposed as follows: • ATA column: Gives the ATA number for the related fault/message. • MESSAGE/FAULT column: Gives the messages/faults, alphabetically ordered. • MAINTENANCE ACTION column: Gives the corrective action (PROCEDURE). It may also inform the EFFECTIVITY and/or FAULT CONDITION. • “IS THE FAULT REMOVED?” column: Gives the results of the procedure indicated in the Maintenance Action column. When the reset procedure does not remove the message/fault, refer to the FAULT ISOLATION MANUAL and do as follows: 1. On the “CAS MESSAGE LIST” or “OBSERVED FAULTS LIST”, in the front matter of the chapter, find the related FAULT CODE (FAULT CODE column). 2. Go to the “FAULT CODE INDEX”, and use the related FAULT CODE to do a check for correlated CMC messages: (a) If there are correlated CMC messages, in the “CORRELATED MAINTENANCE MESSAGE CODE” column, look for the correlated maintenance messages on the CMC (AMM TASK 45-45-00-970-803-A/200) to find the task that you must do. Page 8 May 10
  • 9. (b) If there are no correlated CMC messages go directly to the task given in the “GO TO FIM TASK” column. If you have any doubts about how to use the FIM, refer to FAULT ISOLATION MANUAL USAGE section. Every effort has been made to ensure that the information presented in the Quick-Reference Reset Guide is in accordance with the Fault Isolation Manual. However, in the event of conflict between them, the Fault Isolation Manual shall prevail. NOTE: The Quick-Reference Reset Guide will be reissued on all revisions. Page 9 May 10
  • 10. MAU and SPDA RESET SAFETY PROCEDURES MAU - MAINTENANCE SAFETY PROCEDURES (1) EFFECTIVITY: PRE-MOD SB 170-24-0017 (ON ACFT WITH SPDA BLOCK 6.1) If the aircraft is energized with APU and you need to do the reset of the MAU 1 and MAU 3, you must open the following SSPC to avoid the RAT deployment: •RAT DEPLOY-SPDA1 (CBMENU/CB BY SYS/ELEC) (2) If the aircraft is energized with APU and you open the circuit breaker MAU 3 PWR 1, the APU will shutdown. NOTE: To avoid power interruption, you must energize the aircraft with an AC external power supply. (3) Before you reset MAU 1 or MAU 3 power supplies, make sure that all switches on the HYDRAULIC CONTROL PANEL are set at the OFF position. (4) If you do the MAU reset procedure with the engines in operation, engine related messages can show on the EICAS. We recommend that you stop the engines before the power-supply circuit-breaker cycling procedure. (5) If it is necessary to open the MAU 1 and/or MAU 3 circuit breakers, the message “SPOILER FAULT” “and “A-I WING FAIL” will show on the EICAS. (6) EFFECTIVITY: ON ACFT WITH ‘MAU2 PWR2 PRI’ CIRCUIT BREAKER ON DC ESS BUS 2 If it is necessary to open the MAU 2 PWR 2 PRI-RHCBP (DC ESS BUS 2) circuit breaker, the message “RAT FAIL” will show on the EICAS. Page 10 May 10
  • 11. (7) This procedure must be done to prevent the integrated pitot/static/AOA and TAT system heating in any of these situations: - If you open one of these MAU 1 circuit breakers: • MAU 1 PWR 2-LHCBP (DC ESS BUS 1) • MAU 1 PWR 3-LHCBP (DC BUS 1) - If you open one of these MAU 3 circuit breakers: • MAU 3 PWR 1-RHCBP (DC ESS BUS 2) • MAU 3 PWR 2-RHCBP (DC BUS 2) • MAU 3 CUST I/O 2A-RHCBP (DC ESS BUS 2) • MAU 3 CUST I/O 2B-RHCBP (DC BUS 2) WARNING: THE INTEGRATED PITOT/STATIC/AOA AND TAT HEATING SYSTEMS MUST BE OFF DURING MAINTENANCE. THIS IS BECAUSE SYSTEMS THAT INTERFACE WITH MAU 1, MAU 3 AND SPDA 2 CAN CAUSE THE INTEGRATED PITOT/STATIC/AOAAND TAT SENSORS TO BECOME HOT. THESE SENSORS OPERATE AT HIGH TEMPERATURE. IF YOU TOUCH THEM, THEY WILL CAUSE INJURIES TO YOU. (a) Open this circuit breaker and put a circuit breaker ring and tag (inoperative - do not operate) on it: • PROBE 3 HEATER PWR-RHCBP (DC ESS BUS 3 NAV). (b) On the MCDU, use the sequence in parentheses to open these SSPCs: • TAT 1 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN). • TAT 2 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN). Page 11 May 10
  • 12. (c) Open these circuit breakers and put a circuit breaker ring and tag (inoperative - do not operate) on each one of them: • ADS PROBE 1 HTR-LICC (DC BUS 1) • ADS PROBE 2 HTR-LICC (DC BUS1) • ADS PROBE 4 HTR-RICC (DC BUS 2) (8) To restore the systems affected by the MAU safety procedures to their initial condition, do as follows: (a) Remove the circuit breaker ring and tag (inoperative - do not operate) from this circuit breaker, and close it: • PROBE 3 HEATER PWR-RHCBP (DC ESS BUS 3 NAV) (b) On the MCDU, use the sequence in parentheses to close these SSPCs: • TAT 1 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN) • TAT 2 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN) (c) Remove the circuit breaker ring and tag (inoperative - do not operate) from each of these circuit breakers, and close them: • ADS PROBE 1 HTR-LICC (DC BUS 1) • ADS PROBE 2 HTR-LICC (DC BUS1) • ADS PROBE 4 HTR-RICC (DC BUS 2) Page 12 May 10
  • 13. SPDA - MAINTENANCE SAFETY PROCEDURES (1) Before you reset SPDA 1 or SPDA 2 power supplies, make sure that all switches on the HYDRAULIC CONTROL PANEL are set at the OFF position. (2) This procedure must be done to prevent the integrated pitot/static/AOA and TAT system heating if you open one of these SPDA 2 circuit breakers: • SPDA2 PWR SPLY 1-RICC (DC BUS 2) • SPDA2 PWR SPLY 3-EICC (DC ESS BUS 1) • SPDA2 PWR SPLY 2-RICC (DC ESS BUS 2) • SPDA2 PWR SPLY 4-LICC (DC GND SVC BUS) • SPDA2 I-O MOD 11-RICC (DC ESS BUS 2) WARNING: OBEY ALL THE SPDA SAFETY PROCEDURES. IF YOU DO NOT OBEY THESE PROCEDURES, INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT CAN OCCUR. WARNING: THE INTEGRATED PITOT/STATIC/AOA AND TAT HEATING SYSTEMS MUST BE OFF DURING MAINTENANCE. THIS IS BECAUSE SYSTEMS THAT INTERFACE WITH MAU 1, MAU 3 AND SPDA 2 CAN CAUSE THE INTEGRATED PITOT/STATIC/AOA AND AT SENSORS TO BECOME HOT. THESE SENSORS OPERATE AT HIGH TEMPERATURE. IF YOU TOUCH THEM, THEY WILL CAUSE INJURIES TO YOU. (a) On the MCDU, use the sequence in parentheses to open these SSPCs: • TAT 1 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN) • TAT 2 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN) (b) Open these circuit breakers and put a circuit breaker ring and tag (inoperative - do not operate) on each one of them: Page 13 May 10
  • 14. • PROBE 3 HEATER PWR-RHCBP (DC ESS BUS 3 NAV) • ADS PROBE 1 HTR-LICC (DC BUS 1) • ADS PROBE 2 HTR-LICC (DC BUS1) • ADS PROBE 4 HTR-RICC (DC BUS 2) (3) To restore the systems affected by the SPDA safety procedures, do as follows: (a) On the MCDU, use the sequence in parentheses to close these SSPCs: • TAT 1 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN) • TAT 2 HEAT-SPDA1 (CBMENU/CB BY SYS/ICE/RAIN) (b) Remove the circuit breaker ring and tag (inoperative - do not operate) from these circuit breakers, and close them: • PROBE 3 HEATER PWR-RHCBP (DC ESS BUS 3 NAV) • ADS PROBE 1 HTR-LICC (DC BUS 1) • ADS PROBE 2 HTR-LICC (DC BUS1) • ADS PROBE 4 HTR-RICC (DC BUS 2) Page 14 May 10
  • 15. General Information The purpose of this section is to provide some standard procedures and general information. (1) The Quick-Reference Reset Guide must be used only with the aircraft on the ground. (2) To perform the procedures that follow, refer to AMM TASK 45-45-00-970-805-A: • MAU module reset test; • Initiated BIT; • PBIT; • Clear Inhibit. (3) To open and/or close a SSPC on the MCDU, refer to SDS 34-61-00. Page 15 May 10
  • 16. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH CMF] PROCEDURE: Yes. CAUTION: MAKE SURE THAT THE INTEGRATED FIM TASK 23-24-00-810- PITOT/STATIC/AOA SENSORS, TAT SENSORS, ICE 868-A DETECTORS, AND STATIC PORT HAVE NO COVERS ON THEM ACARS 23 BEFORE YOU DO THE MAINTENANCE PROCEDURE. THESE FROZEN No. COMPONENTS CAN BECOME HOT DURING THE Refer to the correspondent MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO chapter of the FIM for THEM WILL OCCUR IF YOU DO NOT REMOVE THE COVERS. troubleshooting. Open this circuit breaker and, after approximately 5 seconds, close it: • MAU 3 PWR 2-RHCBP (DC BUS 2) May 10 Page 16
  • 17. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT Yes. FIM TASK 34-15-00-810- Open these circuit breakers and, after approximately 5 seconds, 825-A close them: 34 ADS 1 FAIL • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1 NAV) No. • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1 NAV) Refer to the correspondent chapter of the FIM for troubleshooting. Yes. FAULT CONDITION: During power-up FIM TASK 34-15-00-810- 825-A ADS 1 HTR PROCEDURE: Open these circuit breakers and, after 30 seconds, 30 FAIL close them: No. • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1/NAV) Refer to the correspondent • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1/NAV) chapter of the FIM for troubleshooting. May 10 Page 17
  • 18. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT Yes. FAULT CONDITION: During power-up FIM TASK 34-15-00-810- 825-A ADS 1 HTR PROCEDURE: Open these circuit breakers and, after 30 seconds, 30 FAULT close them: No. • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1/NAV) Refer to the correspondent • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1/NAV) chapter of the FIM for troubleshooting. EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS BUS 2] PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) Yes. • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV) FIM TASK 34-15-00-810- • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV) 827-A • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV) 34 ADS 2 FAIL No. EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT Refer to the correspondent BREAKER ON DC ESS BUS 3] chapter of the FIM for troubleshooting. PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV) • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV) • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV) May 10 Page 18
  • 19. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT FAULT CONDITION: During power-up EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS BUS 2] PROCEDURE: Open these circuit breakers and, after 30 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV) Yes. • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2/NAV) FIM TASK 34-15-00-810- • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV) 827-A • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV) ADS 2 HTR 30 FAIL No. EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT Refer to the correspondent BREAKER ON DC ESS BUS 3] chapter of the FIM for 190 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT troubleshooting. BREAKER ON DC ESS BUS 3] PROCEDURE: Open these circuit breakers and, after 30 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV) • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3/NAV) • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV) • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV) May 10 Page 19
  • 20. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT FAULT CONDITION: During power-up EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS BUS 2] PROCEDURE: Open these circuit breakers and, after 30 seconds, Yes. close them: FIM TASK 34-15-00-810- - ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV) 827-A ADS 2 HTR - ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2/NAV) 30 FAULT - ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV) No. - ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV) Refer to the correspondent chapter of the FIM for EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT troubleshooting. BREAKER ON DC ESS BUS 3] 190 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS BUS 3] PROCEDURE: Open these circuit breakers and, after 30 seconds, close them: - ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV) - ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3/NAV) - ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV) - ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV) May 10 Page 20
  • 21. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT FAULT CONDITION: During power-up EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS BUS 2] PROCEDURE: Open these circuit breakers and, after 30 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV) Yes. • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2/NAV) FIM TASK 34-15-00-810- • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV) 827-A • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV) 30 ADS 3 FAIL No. EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT Refer to the correspondent BREAKER ON DC ESS BUS 3] chapter of the FIM for 190 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT troubleshooting. BREAKER ON DC ESS BUS 3] PROCEDURE: Open these circuit breakers and, after 30 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV) • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3/NAV) • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV) • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV) May 10 Page 21
  • 22. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS BUS 2] PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) Yes. • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV) FIM TASK 34-15-00-810- • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV) 811-A • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV) 34 ADS 3 FAIL No. EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT Refer to the correspondent BREAKER ON DC ESS BUS 3] chapter of the FIM for troubleshooting. PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV) • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV) • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV) May 10 Page 22
  • 23. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS BUS 2] PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV) Yes. • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV) FIM TASK 34-15-00-810- • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) ADS 3 833-A • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV) 34 SLIPCOMP No. FAIL EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT Refer to the correspondent BREAKER ON DC ESS BUS 3] chapter of the FIM for troubleshooting. PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV) • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV) • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV) May 10 Page 23
  • 24. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT FAULT CONDITION: During power-up EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS BUS 2] PROCEDURE: Open these circuit breakers and, after 30 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV) Yes. • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2/NAV) FIM TASK 34-15-00-810- • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV) 827-A • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV) ADS 4 HTR 30 FAIL No. EFF: 170 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT Refer to the correspondent BREAKER ON DC ESS BUS 3] chapter of the FIM for 190 - [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT troubleshooting. BREAKER ON DC ESS BUS 3] PROCEDURE: Open these circuit breakers and, after 30 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3/NAV) • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3/NAV) • ADS 2 PROBE 4A-RHCBP (DC BUS 2/NAV) • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2/NAV) May 10 Page 24
  • 25. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS BUS 2] PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV) Yes. • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV) FIM TASK 34-15-00-810- • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) ADS 4 833-A • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV) 34 SLIPCOMP No. FAIL EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT Refer to the correspondent BREAKER ON DC ESS BUS 3] chapter of the FIM for troubleshooting. PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV) • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV) • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV) May 10 Page 25
  • 26. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH PRIMUS EPIC LOAD UP TO 21.5] Yes. FAULT CONDITION 1: The CAS message shows from the moment FIM TASK 34-15-00-810- in which the aircraft is at the gate until the takeoff. ADS 1 FAIL does 852-A not show on the EICAS display. No. PROCEDURE: De-energize the aircraft and energize it again. Refer to the correspondent chapter of the FIM for troubleshooting. FAULT CONDITION 2: The CAS message shows as soon as the Yes. aircraft lands. FIM TASK 34-15-00-810- PROCEDURE: Open these circuit breakers and, after 801-A ADS PROBE 1 approximately 5 seconds, close them: No. 34 FAIL • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1 NAV) Refer to the correspondent • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1 NAV) chapter of the FIM for troubleshooting. Yes. EFF: [ON ACFT WITH PRIMUS EPIC LOAD 23.1 AND ON] FIM TASK 34-15-00-810- FAULT CONDITION: The CAS message shows as soon as the 801-A aircraft lands. No. PROCEDURE: Open these circuit breakers and, after Refer to the correspondent approximately 5 seconds, close them: chapter of the FIM for • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1 NAV) troubleshooting. • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1 NAV) May 10 Page 26
  • 27. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH PRIMUS EPIC LOAD UP TO 21.5] Yes. FAULT CONDITION 1: The CAS message shows from the moment FIM TASK 34-15-00-810- in which the aircraft is at the gate until the takeoff. ADS 1 FAIL does 853-A not show on the EICAS display. No. PROCEDURE: De-energize the aircraft and energize it again. Refer to the correspondent chapter of the FIM for troubleshooting. FAULT CONDITION 2: The CAS message shows as soon as the Yes. aircraft lands. FIM TASK 34-15-00-810- PROCEDURE: Open these circuit breakers and, after 801-A ADS PROBE 2 approximately 5 seconds, close them: No. 34 FAIL • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1 NAV) Refer to the correspondent • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1 NAV) chapter of the FIM for troubleshooting. Yes. EFF: [ON ACFT WITH PRIMUS EPIC LOAD 23.1 AND ON] FIM TASK 34-15-00-810- FAULT CONDITION: The CAS message shows as soon as the 801-A aircraft lands. No. PROCEDURE: Open these circuit breakers and, after Refer to the correspondent approximately 5 seconds, close them: chapter of the FIM for • ADS 1 PROBE 1A-2A-LHCBP (DC BUS 1 NAV) troubleshooting. • ADS FC PROBE 1B-2B-LHCBP (DC BUS 1 NAV) May 10 Page 27
  • 28. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH PRIMUS EPIC LOAD UP TO 21.5] Yes. FAULT CONDITION 1: The CAS message shows from the moment in which the FIM TASK 34-15-00-810-854-A aircraft is at the gate until the takeoff. ADS 2 FAIL and ADS 3 FAIL do not show on the No. EICAS display. Refer to the correspondent PROCEDURE: De-energize the aircraft and energize it again. chapter of the FIM for FAULT CONDITION 2: The CAS message shows as soon as the aircraft lands. troubleshooting. EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS BUS 2] PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV) Yes. EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS FIM TASK 34-15-00-810-806-A BUS 3] No. PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close Refer to the correspondent ADS PROBE 3 them: chapter of the FIM for 34 • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) troubleshooting. FAIL • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV) EFF: [ON ACFT WITH PRIMUS EPIC LOAD 23.1 AND ON] FAULT CONDITION: The CAS message shows as soon as the aircraft lands. EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS BUS 2] PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) Yes. • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 2 NAV) FIM TASK 34-15-00-810-806-A No. EFF: [ON ACFT WITH ADS 3/STBY PROBE 3B CIRCUIT BREAKER ON DC ESS Refer to the correspondent BUS 3] chapter of the FIM for PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close troubleshooting. them: • ADS 2 PROBE 3A-RHCBP (DC ESS BUS 3 NAV) • ADS 3/STBY PROBE 3B-RHCBP (DC ESS BUS 3 NAV) May 10 Page 28
  • 29. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH PRIMUS EPIC LOAD UP TO 21.5] FAULT CONDITION 1: The CAS message shows from the moment Yes. in which the aircraft is at the gate until the takeoff. ADS 2 FAIL and FIM TASK 34-15-00-810- ADS 3 FAIL do not show on the EICAS display. 855-A PROCEDURE: De-energize the aircraft and energize it again. No. Refer to the correspondent chapter of the FIM for troubleshooting. FAULT CONDITION 2: The CAS message shows as soon as the aircraft lands. Yes. PROCEDURE: Open these circuit breakers and, after FIM TASK 34-15-00-810- approximately 5 seconds, close them: 806-A ADS PROBE 4 • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV) No. 34 FAIL • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV) Refer to the correspondent chapter of the FIM for troubleshooting. EFF: [ON ACFT WITH PRIMUS EPIC LOAD 23.1 AND ON] FAULT CONDITION: The CAS message shows as soon as the Yes. aircraft lands. FIM TASK 34-15-00-810- PROCEDURE: Open these circuit breakers and, after 806-A approximately 5 seconds, close them: No. • ADS 2 PROBE 4A-RHCBP (DC BUS 2 NAV) Refer to the correspondent • ADS 3/STBY PROBE 4B-RHCBP (DC ESS BUS 2 NAV) chapter of the FIM for troubleshooting. May 10 Page 29
  • 30. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT On the CMC, in the ACTIVE MAINTENANCE MESSAGES and PRESENT LEG areas, look for any message correlated to the CAS messages below that may be causing the AFCS FAULT. • FLT CTRL NO DISPATCH • FLT CTRL FAULT Yes. • FLAP LO RATE FIM TASK 22-11-00-810- • SLAT LO RATE 815-A • ADS PROBE 1 FAIL 22 AFCS FAULT • ADS PROBE 2 FAIL No. • ADS PROBE 3 FAIL Refer to the correspondent • ADS PROBE 4 FAIL chapter of the FIM for • TAT 1 FAIL troubleshooting. • TAT 2 FAIL • AP FAULT • AFCS FAULT Proceed accordingly. If there is not a correlated message, reset the aircraft. May 10 Page 30
  • 31. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT FAULT CONDITION 1: "A-I ENG 1 FAULT" CAS message can come into view approximately 30 seconds after landing, if the respective bleed system remains off for 10 seconds during any flight phase; OR Yes. FAULT CONDITION 2: Bleed System 1 or 2 is off and the cross FIM TASK 30-21-00-810- bleed valve is closed. 821-A A-I ENG 1 30 EFF: [EMBRAER 190 and 195] FAULT No. Refer to the correspondent PROCEDURE: On the ICE PROTECTION control panel, unlatch chapter of the FIM for (off) the ENGINE 1 and ENGINE 2 switches (lights come on). troubleshooting. Note: After 10 seconds, "A-I SWITCH OFF (advisory)" message shows on the EICAS. On the ICE PROTECTION control panel, latch (on) the ENGINE 1 and ENGINE 2 switches (lights go off). Note: "A-I SWITCH OFF (advisory)" message goes out of view. May 10 Page 31
  • 32. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT FAULT CONDITION 1: "A-I ENG 2 FAULT" CAS message can come into view approximately 30 seconds after landing, if the respective bleed system remains off for 10 seconds during any flight phase; OR Yes. FAULT CONDITION 2: Bleed System 1 or 2 is off and the cross FIM TASK 30-21-00-810- bleed valve is closed. 821-A A-I ENG 2 30 FAULT EFF: [EMBRAER 190 and 195] No. Refer to the correspondent PROCEDURE: On the ICE PROTECTION control panel, unlatch chapter of the FIM for (off) the ENGINE 1 and ENGINE 2 switches (lights come on). troubleshooting. Note: After 10 seconds, "A-I SWITCH OFF (advisory)" message shows on the EICAS. On the ICE PROTECTION control panel, latch (on) the ENGINE 1 and ENGINE 2 switches (lights go off). Note: "A-I SWITCH OFF (advisory)" message goes out of view. May 10 Page 32
  • 33. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT FAULT CONDITION: "A-I WING FAIL" CAS message shows during the BIT (Built-in Test) PROCEDURE: On the overhead panel: • On the ICE PROTECTION control panel, turn the TEST switch to the WING position. • Unlatch the WING switch (light comes on). • After 10 seconds, "A-I SWITCH OFF (advisory)" message shows on the EICAS. • Latch the WING switch (light goes off). Yes. • "A-I SWITCH OFF (advisory)" message goes out of view. Wait for FIM TASK 30-11-00-810- 60 seconds and verify 817-A if message does not show again on the CAS. 30 A-I WING FAIL No. FAULT CONDITION:"A-I WING FAIL" CAS message shows on Refer to the correspondent EICAS with the letters chapter of the FIM for CAS MSG displayed inside a cutout box on both PFDs. troubleshooting. PROCEDURE: On the overhead panel: • On the ICE PROTECTION control panel, turn the TEST switch to the WING position. • Unlatch the WING switch (light comes on). • After 10 seconds, "A-I SWITCH OFF (advisory)" message shows on the EICAS. • Latch the WING switch (light goes off). • "A-I SWITCH OFF (advisory)" message goes out of view. Wait for 60 seconds and verify if message does not show again on the CAS May 10 Page 33
  • 34. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT AMBER "X" FAULT CONDITION: RECIRC switch is set to AUTO, batteries are Yes. ON RECIRC set to ON/AUTO, and the GPU is OFF for more than one minute FIM TASK 21-24-00-810- FAN 805. PROCEDURE: On the overhead panel, on the AIR 21 INDICATION COND/PNEUMATIC control panel, set the RECIRC pushbutton to No. (ECS the unlatched (off) position. Wait 60 seconds and set it back to the Refer to the correspondent SYNOPTIC latched (auto) position. If it does not work, reset the aircraft (power chapter of the FIM for PAGE) down/up). troubleshooting. May 10 Page 34
  • 35. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT Yes. FIM TASK 27-03-00-810- 89L-A AOA LIMIT On the maintenance panel, make sure the FCS MAINT switch is in 27 FAIL the OFF position. No. Refer to the correspondent chapter of the FIM for troubleshooting. Yes. FIM TASK 22-11-00-810- 981-A Make sure that the same ADS and IRS sources are not selected on APPR 2 NOT 22 PFD 1 and PFD 2, the indications of RALT/IRS/ADS/FD are correct AVAIL and there are no messages related to these systems on the EICAS. No. Refer to the correspondent chapter of the FIM for troubleshooting. May 10 Page 35
  • 36. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT Yes. On the MCDU, open these SSPCs and close them after 10 seconds FIM TASK 49-10-00-810- to confirm that the failure has occurred: 801-A • APU FADEC (CB/CB BY SYS/APU) 49 APU FAIL • ABC CMD PWR (CB/CB BY SYS/APU) No. • ASC CMD PWR (CB/CB BY SYS/APU) Refer to the correspondent Start the APU again. chapter of the FIM for troubleshooting. FAULT CONDITION: The APU FUEL SOV FAIL CAS message Yes. was displayed during power-up and an APU start has not been FIM TASK 28-22-00-810- attempted 802-A APU FUEL 28 PROCEDURE: On the APU CONTROL panel set the EMER STOP SOV FAIL pushbutton to the latched in (on) and latched out (off) position. No. Refer to the correspondent chapter of the FIM for NOTE: The resetting is valid only if the failure message occurred troubleshooting. during power-up. May 10 Page 36
  • 37. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT FAULT CONDITION 1: "ENG TLA TRIM FAIL" message is active on the EICAS; AND FAULT CONDITION 2: The following maintenance messages are active on the CMC: 22310005TA1 - ENGINE DATA [TRSA1] FAULT 22310005TA2 - ENGINE DATA [TRSA2] FAULT 22310023TA1 - FADEC1/FADEC2 [ATA1] WRG FAULT 22310023TA2 - FADEC1/FADEC2 [ATA2] WRG FAULT 22310079TA1 - LEFT FADEC [ATA1] FAULT 22310079TA2 - LEFT FADEC [ATA2] FAULT 22310080TA1 - RIGHT FADEC [ATA1] FAULT 22310080TA2 - RIGHT FADEC [ATA2] FAULT NOTE: The recording of "RIGHT FADEC [ATxx] FAULT" or "LEFT FADEC [ATxx] FAULT" maintenance message on the CMC depends on the faulty FADEC. The left FADEC refers to Yes. engine 1 and the right FADEC refers to engine 2. FIM TASK 22-31-00-810- EFF: [ALL] 821-A 22 AT FAIL PROCEDURE: No. On the CMC, use the sequence that follows to get access to the ENGINE 1 GENERAL STATUS PAGE: Refer to the correspondent • 73 - ENGINE FUEL AND CONTROL chapter of the FIM for • 21 - ENGINE FADEC 1A • ENGINE 1 GENERAL STATUS PAGE troubleshooting. If the CHANNEL IN CONTROL status is the same for both channels, go to the FIM TASK 22- 31-00-810-821-A. On the CMC, use the sequence that follows to get access to the ENGINE 2 GENERAL STATUS PAGE: • 73 - ENGINE FUEL AND CONTROL • 21 - ENGINE FADEC 2A • ENGINE 2 GENERAL STATUS PAGE If the CHANNEL IN CONTROL status is the same for both channels, go to the FIM TASK 22- 31-00-810-821-A. May 10 Page 37
  • 38. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT On the CMC, use the sequence that follows to do the PROC module 1 reset test: Yes. • 31 - INDICATING/RECORDING SYSTEMS FIM TASK 45-45-00-810- • 41 - PROC MODULE 1 (MAU 1 SLOT NIC 1) 81B-A • MAU1 PROC1 MODULE RESET TEST AURAL WRN 31 SYS FAIL No. On the CMC, use the sequence that follows to do the PROC Refer to the correspondent module 4 reset test: chapter of the FIM for • 31 - INDICATING/RECORDING SYSTEMS troubleshooting. • 41 - PROC MODULE 4 (MAU 2 SLOT NIC 2) • MAU2 PROC4 MODULE RESET TEST On the CMC, use the sequence that follows to do the PROC module 1 reset test: Yes. • 31 - INDICATING/RECORDING SYSTEMS FIM TASK 45-45-00-810- • 41 - PROC MODULE 1 (MAU 1 SLOT NIC 1) 81B-A • MAU1 PROC1 MODULE RESET TEST AURAL WRN 31 SYS FAULT On the CMC, use the sequence that follows to do the PROC No. Refer to the correspondent module 4 reset test: chapter of the FIM for • 31 - INDICATING/RECORDING SYSTEMS troubleshooting. • 41 - PROC MODULE 4 (MAU 2 SLOT NIC 2) • MAU2 PROC4 MODULE RESET TEST May 10 Page 38
  • 39. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT Yes. FIM TASK 32-41-00-810- 809-A AUTOBRAKE On the CMC (System Diagnostics/ 32 - Landing Gear), run the 32 FAIL RESET TEST for AUTOBRAKE MODULE. No. Refer to the correspondent chapter of the FIM for troubleshooting. CAUTION: MAKE SURE THAT THE INTEGRATED PITOT/STATIC/AOA SENSORS, TAT SENSORS, ICE DETECTORS AND STATIC PORT HAVE NO COVERS ON THEM BEFORE YOU DO THE MAINTENANCE PROCEDURE. THESE COMPONENTS CAN BECOME HOT DURING THE MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO THEM WILL OCCUR IF YOU DO NOT REMOVE THE COVERS. Yes. Open these circuit breakers and, after approximately 5 seconds, close them: FIM TASK 31-42-00-810- NOTE: If power is removed from the CMC module for more than 10 seconds, 808-A AVNX MAU 1A the CMC module will start its shutdown procedure. When power is supplied to 31 the CMC module again, it will start its power-up procedure. The full process FAIL takes approximately 5 minutes. No. • MAU 1 PWR 1-LHCBP (DC ESS BUS 1) Refer to the correspondent • MAU 1 PWR 2-LHCBP (DC ESS BUS 1) chapter of the FIM for • MAU 1 PWR 3-LHCBP (DC BUS 1) troubleshooting. On the CMC, use the sequence that follows to do the MAU 1 NIC module 1 reset test: • 31 - INDICATING/RECORDING SYSTEMS • 41 - MAU 1 NIC 1 • MAU1_NIC1 MODULE RESET TEST May 10 Page 39
  • 40. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT CAUTION: MAKE SURE THAT THE INTEGRATED PITOT/STATIC/AOA SENSORS, TAT SENSORS, ICE DETECTORS AND STATIC PORT HAVE NO COVERS ON THEM BEFORE YOU DO THE MAINTENANCE PROCEDURE. THESE COMPONENTS CAN BECOME HOT DURING THE MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO THEM WILL OCCUR IF YOU DO NOT REMOVE THE COVERS. Yes. Open these circuit breakers and, after approximately 5 seconds, FIM TASK 31-41-00-810- close them: 88S-A AVNX MAU 1A NOTE: If power is removed from the CMC module for more than 10 31 seconds, the CMC module will start its shutdown procedure. When FAULT No. power is supplied to the CMC module again, it will start its power-up Refer to the correspondent procedure. The full process takes approximately 5 minutes. chapter of the FIM for • MAU 1 PWR 1-LHCBP (DC ESS BUS 1) troubleshooting. • MAU 1 PWR 2-LHCBP (DC ESS BUS 1) • MAU 1 PWR 3-LHCBP (DC BUS 1) On the CMC, use the sequence that follows to do the MAU 1 NIC module 1 reset test: • 31 - INDICATING/RECORDING SYSTEMS • 41 - MAU 1 NIC 1 • MAU1_NIC1 MODULE RESET TEST May 10 Page 40
  • 41. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT CAUTION: MAKE SURE THAT THE INTEGRATED PITOT/STATIC/AOA SENSORS, TAT SENSORS, ICE DETECTORS AND STATIC PORT HAVE NO COVERS ON THEM BEFORE YOU DO THE MAINTENANCE PROCEDURE. THESE COMPONENTS CAN BECOME HOT DURING THE MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO THEM WILL OCCUR IF YOU DO NOT REMOVE THE COVERS. Yes. Open these circuit breakers and, after approximately 5 seconds, FIM TASK 31-42-00-810- close them: 809-A AVNX MAU 1B NOTE: If power is removed from the CMC module for more than 10 31 seconds, the CMC module will start its shutdown procedure. When FAIL No. power is supplied to the CMC module again, it will start its power-up Refer to the correspondent procedure. The full process takes approximately 5 minutes. chapter of the FIM for • MAU 1 PWR 1-LHCBP (DC ESS BUS 1) troubleshooting. • MAU 1 PWR 2-LHCBP (DC ESS BUS 1) • MAU 1 PWR 3-LHCBP (DC BUS 1) On the CMC, use the sequence that follows to do the MAU 1 NIC module 1 reset test: • 31 - INDICATING/RECORDING SYSTEMS • 41 - MAU 1 NIC 2 • MAU1_NIC2 MODULE RESET TEST May 10 Page 41
  • 42. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT CAUTION: MAKE SURE THAT THE INTEGRATED PITOT/STATIC/AOA SENSORS, TAT SENSORS, ICE DETECTORS AND STATIC PORT HAVE NO COVERS ON THEM BEFORE YOU DO THE MAINTENANCE PROCEDURE. THESE COMPONENTS CAN BECOME HOT DURING THE MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO THEM WILL OCCUR IF YOU DO NOT REMOVE THE COVERS. Yes. Open these circuit breakers and, after approximately 5 seconds, FIM TASK 31-41-00-810- close them: 88Y-A AVNX MAU 1B NOTE: If power is removed from the module for more than 10 31 seconds, the CMC module will start its shutdown procedure. When FAULT No. power is supplied to the CMC module again, it will start its power-up Refer to the correspondent procedure. The full process takes approximately 5 minutes. chapter of the FIM for • MAU 1 PWR 1-LHCBP (DC ESS BUS 1) troubleshooting. • MAU 1 PWR 2-LHCBP (DC ESS BUS 1) • MAU 1 PWR 3-LHCBP (DC BUS 1) On the CMC, use the sequence that follows to do the MAU 1 NIC module 2 reset test: • 31 - INDICATING/RECORDING SYSTEMS • 41 - MAU 1 NIC 2 • MAU1_NIC2 MODULE RESET TEST May 10 Page 42
  • 43. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON DC BUS 2] PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • MAU 2 PWR 1-RHCBP (DC BUS 2) • MAU 2 PWR 2 PRI-RHCBP (DC BUS 2) • MAU 2 PWR 2 SEC-RHCBP (DC ESS BUS 2) Yes. EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON FIM TASK 31-42-00-810- DC ESS BUS 2] 810-A AVNX MAU 2A 31 PROCEDURE: Open these circuit breakers and, after FAIL No. approximately 5 seconds, close them: Refer to the correspondent • MAU 2 PWR 1-RHCBP (DC BUS 2) chapter of the FIM for • MAU 2 PWR 2 PRI-RHCBP (DC ESS BUS 2) troubleshooting. • MAU 2 PWR 2 SEC-RHCBP (DC BUS 2) EFF: ALL PROCEDURE: On the CMC, use the sequence that follows to do the MAU 2 NIC module 3 reset test: • 31 - INDICATING/RECORDING SYSTEMS • 41 - MAU2 NIC 1 • MAU2_NIC3 MODULE RESET TEST May 10 Page 43
  • 44. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON DC BUS 2] PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • MAU 2 PWR 1-RHCBP (DC BUS 2) • MAU 2 PWR 2 PRI-RHCBP (DC BUS 2) • MAU 2 PWR 2 SEC-RHCBP (DC ESS BUS 2) Yes. EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON FIM TASK 31-41-00-810- DC ESS BUS 2] 89F-A AVNX MAU 2A 31 PROCEDURE: Open these circuit breakers and, after FAULT No. approximately 5 seconds, close them: Refer to the correspondent • MAU 2 PWR 1-RHCBP (DC BUS 2) chapter of the FIM for • MAU 2 PWR 2 PRI-RHCBP (DC ESS BUS 2) troubleshooting. • MAU 2 PWR 2 SEC-RHCBP (DC BUS 2) EFF: ALL PROCEDURE: On the CMC, use the sequence that follows to do the MAU 2 NIC module 3 reset test: • 31 - INDICATING/RECORDING SYSTEMS • 41 - MAU 2 NIC 1 • MAU2_NIC3 MODULE RESET TEST May 10 Page 44
  • 45. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON DC BUS 2] PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • MAU 2 PWR 1-RHCBP (DC BUS 2) • MAU 2 PWR 2 PRI-RHCBP (DC BUS 2) • MAU 2 PWR 2 SEC-RHCBP (DC ESS BUS 2) Yes. EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON FIM TASK 31-42-00-810- DC ESS BUS 2] 811-A AVNX MAU 2B 31 PROCEDURE: Open these circuit breakers and, after FAIL No. approximately 5 seconds, close them: Refer to the correspondent • MAU 2 PWR 1-RHCBP (DC BUS 2) chapter of the FIM for • MAU 2 PWR 2 PRI-RHCBP (DC ESS BUS 2) troubleshooting. • MAU 2 PWR 2 SEC-RHCBP (DC BUS 2) EFF: ALL PROCEDURE: On the CMC, use the sequence that follows to do the MAU 2 NIC module 4 reset test: • 31 - INDICATING/RECORDING SYSTEMS • 41 - MAU 2 NIC 2 • MAU2_NIC4 MODULE RESET TEST May 10 Page 45
  • 46. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON DC BUS 2] PROCEDURE: Open these circuit breakers and, after approximately 5 seconds, close them: • MAU 2 PWR 1-RHCBP (DC BUS 2) • MAU 2 PWR 2 PRI-RHCBP (DC BUS 2) • MAU 2 PWR 2 SEC-RHCBP (DC ESS BUS 2) Yes. EFF: [ON ACFT WITH ’MAU2 PWR2 PRI’ CIRCUIT BREAKER ON FIM TASK 31-41-00-810- DC ESS BUS 2] 89M-A AVNX MAU 2B 31 PROCEDURE: Open these circuit breakers and, after FAULT No. approximately 5 seconds, close them: Refer to the correspondent • MAU 2 PWR 1-RHCBP (DC BUS 2) chapter of the FIM for • MAU 2 PWR 2 PRI-RHCBP (DC ESS BUS 2) troubleshooting. • MAU 2 PWR 2 SEC-RHCBP (DC BUS 2) EFF: ALL PROCEDURE: On the CMC, use the sequence that follows to do the MAU 2 NIC module 4 reset test: • 31 - INDICATING/RECORDING SYSTEMS • 41 - MAU 2 NIC 2 • MAU2_NIC4 MODULE RESET TEST May 10 Page 46
  • 47. MESSAGE / IS THE FAULT ATA MAINTENANCE ACTION REMOVED? FAULT CAUTION: MAKE SURE THAT THE INTEGRATED PITOT/STATIC/AOA SENSORS, TAT SENSORS, ICE DETECTORS AND STATIC PORT HAVE NO COVERS ON THEM BEFORE YOU DO THE MAINTENANCE PROCEDURE. THESE COMPONENTS CAN BECOME HOT DURING THE MAINTENANCE PROCEDURE. AS A RESULT, DAMAGE TO Yes. THEM WILL OCCUR IF YOU DO NOT REMOVE THE COVERS. FIM TASK 31-42-00-810- 812-A AVNX MAU 3A Open these circuit breakers and, after approximately 5 seconds, 31 FAIL close them: No. • MAU 3 PWR 1-RHCBP (DC ESS BUS 2) Refer to the correspondent • MAU 3 PWR 2-RHCBP (DC BUS 2) chapter of the FIM for troubleshooting. On the CMC, use the sequence that follows to do the MAU 3 NIC module 5 reset test: • 31 - INDICATING/RECORDING SYSTEMS • 41 - MAU 3 NIC 1 • MAU3 NIC5 MODULE RESET TEST May 10 Page 47