3. INTRODUCTION
INFORMATION OF ACTIVITIES CARRIED
OUT AT PRABODHANKAR K. S.
THACKAREY NATAYAMDNIR
• 1. MAIN AUDITORIUM
• 2. MINI AUDITORIUM
• 3. ART GALLERY
• 4. CONFERENCE HALL
• 5. COMMUNITY HALL
• 6. REHEARSAL ROOM
• 7. RESIDENTIAL ROOM
• 8. PAY & PARK .
• STARTING OF CONSTRUCTION – 1994
• YEAR OF COMPLETION – 2000
• INAUGURATION – 11TH MARCH 2001
• CLOSED FOR RENEWATION – FEBRUARY 2009
• REOPENING – NOVEMBER 2009
6. MAIN AUDITORIUM
• THIS AUDITORIUM IS AIR
CONDITIONED.
• SEATING CAPACITY OF 1026, 726
FOR STALL AND 300 FOR BALCONY.
• MAIN STAGE DIMENSION – 40*58
FT
• BACK STAGE DIMENSION – 10*12 FT
• CLEAR HEIGHT ABOVE STAGE – 25
FT
• CLEAR HEIGHT OF AUDITORIUM
HALL – 30 FT
• STAGE IS EQUIPPED WITH
ADVANCED ELECTRIC SYSTEM.
8. MINI AUDITORIUM
• THIS AUDITORIUM IS AIR
CONDITIONED
• SEATING CAPACITY OF 211.
• MAIN STAGE DIMENSION – 25*40
FT
• BACK STAGE DIMENSION – 8*10 FT
• CLEAR HEIGHT ABOVE STAGE – 15
FT
• CLEAR HEIGHT OF AUDITORIUM
HALL – 20 FT
• STAGE IS EQUIPPED WITH
ADVANCED ELECTRIC SYSTEM.
• THIS AUDITORIUM IS PROVIDED
FOR DRAMAS, SCHOOL ANNUAL
FUNCTIONS, CHILDREN’S DRAMA,
GET-TOGETHER, SEMINARS,
ORCHESTRAS, ANNUAL MEETINGS
ETC.
9. • ACOUSTICS SPECIALLY DESIGNED
KEEPING AN AIM TO AVOID ECHO
AND REFLECTION OF SOUND.
• IRREGULAR SURFACE FINISHES
CREATED TO ABSORB THE SOUND
AND NOT TO REFLECT.
• POROUS PLASTER BOARDS USED
IN FALSE CEILING.
10. • THE MATERIAL USED ON THE SIDE
WALLS IS AN INSPIRATION FROM
JUTE.
• WOODEN FLOORING WITH
SCREEDING TO BLOCK UNNECESSARY
SOUND OF FEET.
• COCONUT POPSICLES (KATHYA) IS
USED FOR ACOUSTIOCS ON THE
WALL TO AVOID SOUND REFLECTION.
11. BACKSTAGE
• 2 CHANGING ROOMS
AND 2 MAKE-UP
ROOMS.
• SPACE FOR LOADING-
UNLOADING OF
THEATRE
EQUIPMENTS.
• BACK SATGE ENTRY
FOR ARTIST.
• STAIRCASE FOR
REHEARSAL ROOM
(FIRST FLOOR).
12. GREEN ROOMS
• 4 GREEN ROOMS.
• EACH MEASURING 10*12
FT.
• SEPARATE TOILET FOR
EACH GREEN ROOM.
• DRESSERS WITH SPOT
LIGHTS.
• IRONING TABLE.
• CENTRAL SPACE FOR
REHEARSAL.
13. REHEARSAL ROOMS
• WOODEN FLOORING WITH SAND BELOW
• MIRRORS ON ONE WALL
• ROOM DIMENSION – 15*30 FT
14. CONTROL ROOM
• ELECTRICITY COMES
FROM POWER SUPPLIER
TO SITE SUBSTATION.
• THEN IT COMES TO
CONTROL ROOM IN
THREE PHASE OR ONE
PHASE SYSTEM.
• FURTHER DIRECT SUPPLY
TO THEATRE
EQUIPMENTS.
• MAIN SWITCH OF DIESEL
GENERATOR.
SITE SUBSTATION
19. CONFERENCE HALL
• IT IS DIVIDED IN THREE PARTS WITH SLIDING PARTITIONS AND CAN BE
PROVIDED SEPARATELY FOR SMALL ACTIVITIES LIKE MEETINGS, SEMINARS,
REHEARSALS ETC.
20. COMMUNITY HALL
• THIS HALL IS SITUATED AT 3RD FLOOR
OF ‘A’ WING HAVING CAPACITY TO
ACCOMMODATE ABOUT 300
PERSONS WHICH IS FOR PUBLIC
FUNCTIONS