2. Cool roofs are the roofs that can deliver
high solar reflectance (the ability to reflect the
visible, infrared and ultraviolet wavelengths of the
sun, reducing heat transfer to the building) and
high thermal emittance (the ability to radiate
absorbed, or non-reflected solar energy).The
benefits associated with cool roofs include
reduced cooling energy load, reduced air pollution
and greenhouse gas emission, and improved human
health and comfort. Cool roofs may extend the
roof service life and help in mitigating the urban
heat island effect. Cool roofs achieve cooling
energy savings in hot summers but can increase
heating energy load during cold winters.
9. 0.70
0.65 CRRC Approved Color Families Bright
White White
0.55 Tan
Beige
0.45
Off-White
Pearlescent
0.40 Silver
Pearlescent
Copper
TSR
0.35
Terra Cotta Medium to Bright Red
Light Gray
0.32
Medium to Medium to Medium to
Light Blue Light Brown Light Green
0.25
Red Dark Blue Dark Brown Dark Green Black Dark Grey
11. What is Energy Star ???
ENERGY STAR is a joint program of
the U.S. Environmental
Protection Agency and the U.S.
Department of Energy helping us
all save money and protect the
environment through energy
efficient products and practices.
18. ScanRoof
• Profile
– Northern European tile
configuration with a 7 7/8”
repeat pattern
• Material
– 24 ga. G90 galvanized steel
• Pitch 3:12
• Finish
– Fluoropolymer
Kynar 500®/Hylar 5000®
Z Purlin
Lip
Standard Length - 21 Modules - 13’ 10”
19. ScanRoof
• Structural
– Spans up to 4’ 0” o.c.
– Apply to open frame system or solid underlayment
• 2” integral Z purlin
– Allows for air flow between panel and substrate
• Lightweight
– Finished systems weighs only 145 lbs. per square
– Tradition clay tile weighs up to 900 lbs. per square
• Ideal for re-roofing
– Often can be applied over current roofing materials
– Eliminates “tear-off”
20. ScanRoof
„ Applications
‟ Commercial and residential roofing
‟ Mansards
‟ Equipment screens
„ Field tested and approved
‟ UL580 class 90
‟ UL790 class A & B (fire)
‟ ICBO (4623)
23. TechoTile
• Profile
– “S” or mission tile configuration
– Scallop is an 8” repeat
• Material
– .032 aluminum
– 26 ga., 24 ga. G90 galvanized steel
• Pitch 3:12
• Finish 14”
– Fluoropolymer Kynar500®/ 8”
Hylar 5000®
• Textures
– Traditional matte
– Glazed
Panel is 42” wide
39 ¾” exposed 42” minimum
(3 tiles)
24. TechoTile
• Structural
– Spans up to 28” o.c.
– Apply to open frame system or solid underlayment
• Easy to install
– Eave to ridge application
– Custom cut lengths
• Lightweight
– Finished systems weighs only 145 lbs./sq. in steel;
75lbs./sq. in aluminum
• Ideal for re-roofing
– Often can be applied over current roofing
materials
– Eliminates “tear-off”
25. TechoTile
• Applications
– Commercial and
residential roofing
– Mansards
– Equipment screens
• Testing
– Tested in accordance
with Dade County
Protocol PA 100-95
28. Castle Top
• Four way panel overlap
• Concealed fasteners
• Easy to install
– Eave to ridge application
– 78 pieces per square
• Ideal for re-roofing
– Often can be applied over current roofing
materials
– Eliminates “tear-off”
• Design flexibility
– Coordinate colors to create patterns
33. ADVANTA Shingle
• Four-way interlock panel
• Clip-less shingle
• Secure with ring-shank roofing nails
• Full 3 SQF net coverage
• 95 lbs. per square
• Easy to install
– Eave to ridge installation
• Ideal for re-roofing
– Often can be applied over current roofing materials
– Eliminates “tear-off”
34. ADVANTA Shingle
• Applications
– Commercial and residential roofing
• Designed to be in accordance with
standards established by new governing
code bodies.
• Testing
– Tested in accordance with Dade County
Protocol PA 100-95
36. Key Definitions
„ TSR / Total Solar Reflectance: amount of radiant energy
reflected by a roofing material. Range is from 0 (total
absorption and/or transmission) to 1.0 (total reflection).
„ Thermal Emittance: the ability of a material to release heat that
it has absorbed. Range is from 0 to 1.0. The higher the emittance
the better
„ Production Line Color: “Standard color offerings by the
manufacturer and are promoted in general product information
and in marketing materials”
„ Custom Color: A Custom Color is not individually promoted in
general product information and marketing materials.
„ Color Families: 18 specific color space ranges designed by the CMRC
to allow Licensed Sellers with large color portfolios to
register groups of colors at a reduced cost with the CRRC. (
Hunter L a b / Default SRV )
„ AITL: Accredited Independent Test Laboratory. Independent lab
accredited by the CRRC to evaluate radiative properties of
roofing materials
„ AMTL: Accredited Manufacturing Test Laboratory. Lab affiliated
with a Licensed Seller or OM accredited by the CRRC to evaluate
radiative properties of roofing materials