                                CUSTOMER BULLETIN 0611
                               Insulant Impact on Corrosion in
                          Steel Piping Applications Below 32°F

BACKGROUND

Corrosion is defined by the National Association of Corrosion Engineers as “the deterioration of
a material, usually a metal, by reaction with its environment.” Corrosion under insulation (CUI) is
not a distinct form of corrosion; rather it refers to the location where pipe wall material
deterioration is occurring—underneath the insulation material and on the external surfaces of
piping. CUI (and the corrosion of metal jackets and banding which is not addressed herein) is a
recognized problem that must be addressed by designers, specifiers, and end-users. CUI can
occur under any type of thermal insulation. The type of corrosion will depend on the metallurgy
of the pipe as well as the mix of corrosive elements - - understanding that corrosive elements
can be introduced during pipe production, pipe shipping/storage, installation, insulation contact,
process liquid contact, weather, or other environmental influences.

Focusing on CUI, the three most common types of CUI include oxidation (rusting), stress
corrosion cracking (SCC), and pitting. Yet there are also several specialized types of CUI such
as formicary corrosion1 of copper which in general are not associated with insulated refrigerant
systems and therefore not addressed herein. Metals vary considerably in their susceptibility to
various types of corrosion.

PURPOSE

The purpose of this Customer Bulletin is to provide general information on the causes of CUI in
steel pipe, which insulants in general terms may be best for low temperature applications, and
how to avoid of CUI in steel piping systems operating at service temperatures below 32°F.

We also discuss how corrosion differs between the two common types of steel2 used in such
piping systems. To keep it simple, we define carbon steel as steel with less than 10.5%
chromium, and stainless steel3 as a steel with a minimum of 10.5% chromium content by weight.


1
 Formicary (“ants-nest) corrosion may best be described as micro-pitting most common in refrigeration grade copper tubing in
HVAC systems although other forms of attack, similar in appearance, have been observed in other alloys. Although poorly
understood, attack has been attributed to the growing use of synthetic lubricating oils that were introduced as refrigerant fluids
changed, or to vaporous species derived from the immediate surroundings, including volatiles from process fluids.

2
    We define “Steel” as an alloy that consists mostly of iron and has a carbon content between 0.2% and 2.1% by weight.

3
    Refer to http://www.corrosionist.com/Stainless_Steel_grades.htm.



CB 0611                                                                                                               June 2011
Page 2 of 7


There are of course many types and grades of both carbon and stainless steels, with varying
degrees of susceptibility to various corrosion processes.

SUMMARY

Too often, discussions of CUI focus only on the insulation, rather than on the broader spectrum
of factors that will more likely be the cause of any CUI. At temperatures below 32F, the
likelihood of any form of CUI is remote. Yet the majority of mechanical systems spend some
time above 32F, such as during outages, so the extent to which an insulant may contribute to
CUI must be considered. There are several premises to keep in mind:

   1. CUI can in fact occur under any insulant - - some more likely than others

           a. Insulants with higher Water Absorption and Water Vapor Transmission
              exacerbate CUI

           b. Insulants with higher leachable chlorides (or fluorides) can exacerbate CUI (yet
              such ions must be leachable at the actual temperature presents, and the
              temperature must be above 32F!)

           c. CUI is time and temperature dependent

   2. CUI can be prevented from occurring by following basic guidelines:

       -   Pre-design identification of environmental factors that could exacerbate CUI, such as
           rain, acid rain, humidity, “salt air”, wash-down water/chemicals, sprinkler systems,
           fire control systems, etc.);

       -   Pipe/component design using appropriate metallurgy for the conditions, and control
           of metallurgy during construction (e.g. welding; pickling/heat treating; avoidance of
           dissimilar metals in contact; etc.);

       -   Proper specification and application of any pipe coatings;

       -   Proper selection and installation of insulation system materials (insulant, vapor
           barriers, jackets, mastics, etc.);

              o   This includes compliance with the guidelines of the manufacturers of the various
                  insulation system components as well as the procedures established by a qualified
                  insulation engineer, including for example, keeping the insulation and pipe surfaces
                  dry during the installation process.

              o   Zero-perm vapor barriers can eliminate moisture penetration from the environment.

       -   Operational diligence, including such action as avoidance of excessive impingement
           of water on pipe during wash-downs, periodic inspection for corrosion, and proper



CB 0611                                                                                     June 2011
Page 3 of 7


              replacement of the insulation and insulation components after mechanical repairs or
              inspection.

Dyplast is not a piping system designer, so cannot provide credible advice on the overall design
of a piping system. We thus focus on insulant selection in the next subsection, and on some
general information on corrosion in the remainder of the document - - so the involved parties
may better understand the issues and thus better able to communicate with system designers,
engineers, and contractors.

         Insulant Selection

         Selection of the optimal insulant material is first driven by the long term thermal
         performance of the insulant, just as the first priority of the piping is to ensure mechanical
         integrity of the process. Corrosion mitigation must inevitably be a secondary concern,
         unless the pipe system is likely to be exposed to a chemically intense environment, such
         as an acid regeneration plant in a steel mill with frequent leaks. In such an environment,
         cellular glass may be the only insulant that could withstand the chemical onslaught,
         assuming the chemicals do not include hydrogen fluoride, hydrofluoric acid, or related
         compounds.

         As explained in Customer Bulletin 0411, polyisocyanurate (particularly Dyplast’s ISO-C1)
         is inevitably the optimal selection in the vast majority of piping applications with
         operating temperatures below 32°F. Polyiso’s thermal conductivity combined with its
         moisture resistance characteristics result in energy savings and process control
         advantages that far outweigh any concern over corrosion.

         The additional good news is that ISO-C1 polyiso is low in leachable chloride. At the low
         temperatures typical of a polyiso installation, CUI is highly unlikely. In systems where
         there is frequent cycling above 32F, pipe coatings4 can further mitigate any risk of CUI.



CORROSION OF STEEL: GENERAL

While dramatically different in nature, the corrosion through oxidation, SCC, and pitting each
share one common requirement - - moisture. The corrosion of metals is an electrochemical
process. That is, there is an electrical circuit where the exchange of electrons (electricity) is

4
 Typical industry practice is to apply an epoxy primer in the following circumstances: 1) for 300 series stainless steel systems
operating in a temperature range between 140°F and 300°F or if in a cycling temperature service where the service temperature is
between 140° and 300°F for more than 20% of the time; and 2) for carbon steel piping operating at a service temperature between
32°F and 300°F or in cycling temperature service where the service temperature is between 32°F and 300°F for more than 20%
of the time shall be at a minimum primer coated with an epoxy coating. Coating manufacturers should be consulted for
appropriate coating materials and application methods for the operating temperature range of the equipment.




CB 0611                                                                                                           June 2011
Page 4 of 7


conducted by chemical reactions in part of the circuit. These chemical reactions occur at the
surface of the metal exposed to the electrolyte.

Water in the form of liquid or vapor must be present at the surface of the metal for corrosion to
occur. Therefore, anything that can be done to prevent moisture (rain, wash-down water,
sprinkler systems, condensation, etc.) from reaching the metal surface will help prevent
corrosion from occurring. Selecting an insulant with both low water absorption and water vapor
transmission, and properly installing a zero-perm vapor barrier with a protective jacket is an
appropriate approach in addition to minimizing the external presence of water.

The presence of leachable chloride or certain other elements has been found to exacerbate
corrosion. Too often the search for the source of such ions has been centered incorrectly on the
insulation system components, rather than an external environmental factor which is more often
the cause.

Chemical exposure is the final major environmental element affecting CUI. Acids and acid
gases, hydrochloric acid, sulfuric acid, strong bases (caustics), and salts are aggressive
corrosive agents and will both cause and accelerate CUI. The complexity of addressing the
reaction of various metals to corrosion by chemicals is beyond the scope of this Customer
Bulletin.

OXIDATION

Oxidation (or simply rusting) is sometimes referred to as uniform corrosion, and is one of the
most common mechanisms for corrosion of carbon steel pipe; oxidation does not occur on
stainless steel. Oxidation of carbon steel involves four requisites:

    1.   High temperature
    2.   Moisture
    3.   Oxygen
    4.   Concentration of corrosive ions

It is an inescapable fact that iron in the presence of oxygen and water is thermodynamically
unstable with respect to its oxides. Because oxidation corrosion is an electrolytic process, the
presence of an electrolyte is required. This should not be taken to mean that the steel surface
must be awash in water; a very thin adsorbed film of water is all that is required.

Oxidation on carbon steel pipe can occur between 32°F and 300°F; the “optimum” temperature
range for aggressive corrosion seems to be between 200°F and 240°F5. In this range, there is



5
 “Is There a Cure for Corrosion Under Insulation?” Michael Lettich, National Insulation Association,
http://www.insulation.org/articles/article.cfm?id=IO051101




CB 0611                                                                                                    June 2011
Page 5 of 7


plenty of heat energy but not enough heat to efficiently evaporate moisture before it contacts the
equipment surface. Corrosion rates can double for every 18°F rise in temperature6.

At the service temperatures considered in this paper (below freezing point of water), the
temperature should be insufficient to precipitate corrosion even if water, oxygen, and chloride
ions are present. Yet, virtually all piping systems spend some time at ambient temperatures,
such as during shutdowns for maintenance. Thus there must still be an exerted effort to
minimize moisture and the presence of chloride or other environmental contributors or catalysts
An insulation engineer should be consulted when a carbon steel mechanical system cycles into
service temperatures between 32°F and 300°F for more than 20% of the time. Typical practice
in such circumstance is to apply an epoxy coating, or equivalent.

PITTING (OR CREVICE) CORROSION

Pitting corrosion is a broad term for corrosion that either begins within pits (non-uniformities) in
the pipe surface, or causes pits. Pipe failure can occur if a pit fully penetrates the pipe wall.
Pitting can occur in both carbon steel and stainless steel pipes, although it is more commonly
associated with stainless steels. Pitting is often considered to be more dangerous than uniform
corrosion damage because it is more difficult to detect, predict and design against.

Generally, pitting on pipe exteriors can be associated with:

    -    Localized chemical or mechanical damage to the protective oxide films in carbon steel;

              o   chemistry factors such as acidic rain or high concentrations of chloride (as in salt
                  air that has penetrated the insulation system, or indeed from a poorly selected
                  insulant itself in certain circumstances) can cause breakdown of a passive film;
                  and/or

    -    The presence of non-uniformities in the metal structure of the component (e.g.
         nonmetallic inclusions); and/or

    -    Localized damage to the protective chromium oxide layer on stainless steel (such as at
         manganese sulfide inclusions on the steel surface) caused by:

              o   chloride or chlorine-containing ions

              o   bromides (fluorides and iodides are not aggressive)

              o   cupric, ferric and mercuric ions (such ions may act in concert with chloride to
                  promote pitting without dissolved O2) [or may indeed prevent pitting in a
                  phosphoric acid environment (e.g. it’s complicated)];


6
 Mechanical Integrity and Carbon Steel Refrigerant Piping, Daniel J. Dettmers and Douglas T. Reindl, ASHRAE Journal,
October 2007


CB 0611                                                                                                      June 2011
Page 6 of 7


             o    thiosulphate ions (S2O3) may also promote pitting.

Metals that are susceptible to uniform corrosion (e.g. carbon steel) do not tend to suffer from
pitting. Thus, carbon steel will corrode uniformly in sea water, while stainless steel will pit. An
addition of about 2% of molybdenum increases pitting resistance of stainless steels.

Note that crevice corrosion takes place where physical crevices are present, such as at the joint
between two overlapping sheets of stainless steel, in the crevice between a stainless steel
flange and a non-metallic gasket or under surface deposits.



STRESS CORROSION CRACKING

SCC is the initiation and propagation of micro-cracks caused by the combined effects of tensile
stress coupled with direct surface contact with an enabling chemical7. The stress can be
externally applied, thermal, or residual from the manufacturing process. This stress, coupled
with a susceptible material and environment, causes small cracks inherent or formed in the
material to propagate - - thereby relieving the material’s stress. If the stress level is low, the
cracks will self-limit (stop propagating) prior to fully penetrating the pipe wall. If the stress level is
high, the cracks have the potential to propagate completely through the entire wall thickness,
resulting in a leak.

Contrary to conventional wisdom, Stress Corrosion Cracking (SCC) can occur in carbon steels
as well as stainless steels. Yet SCC in carbon steel pipes is unusual on the exterior of the pipe
since it requires exposure to either hydroxides, nitrates, carbonate, bicarbonates, liquid
ammonia, or CO/CO2/H2O at very low temperatures. SCC in carbon steel is more of a concern
on the inside the pipe in certain ammonia refrigerant applications/conditions where oxygen may
be present.

The most common form of SCC in mechanical systems within the temperature ranges
addressed in this document is Chloride Stress Corrosion of stainless steel pipe, which involves
four requisites:

    1.   High temperature
    2.   Chloride (or fluoride or similar) ions
    3.   Moisture (dissolved oxygen)
    4.   Metal is under tensile stress


Chloride SCC can occur between 140°F and 300°F for 300 series stainless steel. The
"optimum" temperature range for aggressive corrosion on 300 series stainless steel seems to


7
 American Society of Materials International. 2003. ASMI Handbook Volume 13a, Corrosion: Fundamentals, Testing, and
Protection, “Selecting Materials to Prevent or Control Corrosion.”


CB 0611                                                                                                    June 2011
Page 7 of 7


be between 200°F and 240°F. Chloride SCC is most commonly overcome by using a duplex
stainless steel, such as 2205, or a grade with a higher nickel content, such as a 6% Mo material
or high-nickel alloys like Alloy 825 (N08825). Ferritic stainless steels are very resistant to SCC
but grades with equivalent pitting resistance to the austenitic grades have other major
drawbacks.




CB 0611                                                                                June 2011

More Related Content

Viewers also liked

Marks Sattin Accounting Sector Market Research Presentation - Sydney
Marks Sattin Accounting Sector Market Research Presentation - SydneyMarks Sattin Accounting Sector Market Research Presentation - Sydney
Marks Sattin Accounting Sector Market Research Presentation - Sydneyieuan84
 
Social Media Efficiency 5 31-12
Social Media Efficiency 5 31-12Social Media Efficiency 5 31-12
Social Media Efficiency 5 31-12mydutchuncle
 
Mooc: BUSCAR INFORMACIÓN EN GOOGLE
Mooc: BUSCAR INFORMACIÓN EN GOOGLEMooc: BUSCAR INFORMACIÓN EN GOOGLE
Mooc: BUSCAR INFORMACIÓN EN GOOGLENelsonshare
 
Discovery of Cow Rumen Biomass-Degrading Genes and Genomes through DNA Sequen...
Discovery of Cow Rumen Biomass-Degrading Genes and Genomes through DNA Sequen...Discovery of Cow Rumen Biomass-Degrading Genes and Genomes through DNA Sequen...
Discovery of Cow Rumen Biomass-Degrading Genes and Genomes through DNA Sequen...Copenhagenomics
 
惠南镇日间照料中心设计方案2
惠南镇日间照料中心设计方案2惠南镇日间照料中心设计方案2
惠南镇日间照料中心设计方案2yongnianlou
 
Case Study: Philadelphia Mail Processing and Distribution
Case Study: Philadelphia Mail Processing and DistributionCase Study: Philadelphia Mail Processing and Distribution
Case Study: Philadelphia Mail Processing and DistributionDyplast Products
 
07 bio มข
07 bio มข07 bio มข
07 bio มขBiobiome
 

Viewers also liked (9)

Marks Sattin Accounting Sector Market Research Presentation - Sydney
Marks Sattin Accounting Sector Market Research Presentation - SydneyMarks Sattin Accounting Sector Market Research Presentation - Sydney
Marks Sattin Accounting Sector Market Research Presentation - Sydney
 
Social Media Efficiency 5 31-12
Social Media Efficiency 5 31-12Social Media Efficiency 5 31-12
Social Media Efficiency 5 31-12
 
Mooc: BUSCAR INFORMACIÓN EN GOOGLE
Mooc: BUSCAR INFORMACIÓN EN GOOGLEMooc: BUSCAR INFORMACIÓN EN GOOGLE
Mooc: BUSCAR INFORMACIÓN EN GOOGLE
 
No Title
No TitleNo Title
No Title
 
Discovery of Cow Rumen Biomass-Degrading Genes and Genomes through DNA Sequen...
Discovery of Cow Rumen Biomass-Degrading Genes and Genomes through DNA Sequen...Discovery of Cow Rumen Biomass-Degrading Genes and Genomes through DNA Sequen...
Discovery of Cow Rumen Biomass-Degrading Genes and Genomes through DNA Sequen...
 
惠南镇日间照料中心设计方案2
惠南镇日间照料中心设计方案2惠南镇日间照料中心设计方案2
惠南镇日间照料中心设计方案2
 
Case Study: Philadelphia Mail Processing and Distribution
Case Study: Philadelphia Mail Processing and DistributionCase Study: Philadelphia Mail Processing and Distribution
Case Study: Philadelphia Mail Processing and Distribution
 
Rails3 asset-pipeline
Rails3 asset-pipelineRails3 asset-pipeline
Rails3 asset-pipeline
 
07 bio มข
07 bio มข07 bio มข
07 bio มข
 

More from Joe Hughes

Qwik-Guide PIR vs XPS Pipe Insulation 0518
Qwik-Guide PIR vs XPS Pipe Insulation 0518Qwik-Guide PIR vs XPS Pipe Insulation 0518
Qwik-Guide PIR vs XPS Pipe Insulation 0518Joe Hughes
 
Technical Bulletin 0418 Polyiso vs. XPS Pipe Insulation Systems
Technical Bulletin 0418 Polyiso vs. XPS Pipe Insulation SystemsTechnical Bulletin 0418 Polyiso vs. XPS Pipe Insulation Systems
Technical Bulletin 0418 Polyiso vs. XPS Pipe Insulation SystemsJoe Hughes
 
QWIK GUIDE: GeoFoam 0218
QWIK GUIDE: GeoFoam 0218QWIK GUIDE: GeoFoam 0218
QWIK GUIDE: GeoFoam 0218Joe Hughes
 
Customer Bulletin 0717 ISO C1® Polyisocyanurate Insulation Flame Spread and S...
Customer Bulletin 0717 ISO C1® Polyisocyanurate Insulation Flame Spread and S...Customer Bulletin 0717 ISO C1® Polyisocyanurate Insulation Flame Spread and S...
Customer Bulletin 0717 ISO C1® Polyisocyanurate Insulation Flame Spread and S...Joe Hughes
 
LNG Industry Magazine (Commercial Quality Control The Missing Link) Jan 2017
LNG Industry Magazine (Commercial Quality Control The Missing Link) Jan 2017LNG Industry Magazine (Commercial Quality Control The Missing Link) Jan 2017
LNG Industry Magazine (Commercial Quality Control The Missing Link) Jan 2017Joe Hughes
 
LNG Industry Magazine (Risk Mitigation Standards) July 2016
LNG Industry Magazine (Risk Mitigation Standards) July 2016LNG Industry Magazine (Risk Mitigation Standards) July 2016
LNG Industry Magazine (Risk Mitigation Standards) July 2016Joe Hughes
 
LNG Industry Magazine (Logical Thinking) Feb 2016
LNG Industry Magazine (Logical Thinking) Feb 2016LNG Industry Magazine (Logical Thinking) Feb 2016
LNG Industry Magazine (Logical Thinking) Feb 2016Joe Hughes
 
The Role of the Insulation System in Optimizing value in LNG Facilities
The Role of the Insulation System in Optimizing value in LNG FacilitiesThe Role of the Insulation System in Optimizing value in LNG Facilities
The Role of the Insulation System in Optimizing value in LNG FacilitiesJoe Hughes
 
2015 RETA's Exhibition Conference
2015 RETA's Exhibition Conference2015 RETA's Exhibition Conference
2015 RETA's Exhibition ConferenceJoe Hughes
 
2015 SWICA 57th Annual Conference
2015 SWICA 57th Annual Conference2015 SWICA 57th Annual Conference
2015 SWICA 57th Annual ConferenceJoe Hughes
 
2015 Polyurethanes Technical Conference
2015 Polyurethanes Technical Conference2015 Polyurethanes Technical Conference
2015 Polyurethanes Technical ConferenceJoe Hughes
 
2015 ESICA Conference
2015 ESICA Conference2015 ESICA Conference
2015 ESICA ConferenceJoe Hughes
 
Polyisocyanurate Environmental Sustainability
Polyisocyanurate Environmental SustainabilityPolyisocyanurate Environmental Sustainability
Polyisocyanurate Environmental SustainabilityJoe Hughes
 
2015 SWICA EXPO
2015 SWICA EXPO2015 SWICA EXPO
2015 SWICA EXPOJoe Hughes
 
Technical Bulletin 0714 Elastomeric insulation versus polyisocyanurate in low...
Technical Bulletin 0714 Elastomeric insulation versus polyisocyanurate in low...Technical Bulletin 0714 Elastomeric insulation versus polyisocyanurate in low...
Technical Bulletin 0714 Elastomeric insulation versus polyisocyanurate in low...Joe Hughes
 
Customer Bulletin 05-15 A Comparison of ISO-C1 and HT-300 Polyisocyanurate In...
Customer Bulletin 05-15 A Comparison of ISO-C1 and HT-300 Polyisocyanurate In...Customer Bulletin 05-15 A Comparison of ISO-C1 and HT-300 Polyisocyanurate In...
Customer Bulletin 05-15 A Comparison of ISO-C1 and HT-300 Polyisocyanurate In...Joe Hughes
 
Technical Bulletin 0213 Polyisocyanurate vs. Cellular Glass Insulation
Technical Bulletin 0213 Polyisocyanurate vs. Cellular Glass InsulationTechnical Bulletin 0213 Polyisocyanurate vs. Cellular Glass Insulation
Technical Bulletin 0213 Polyisocyanurate vs. Cellular Glass InsulationJoe Hughes
 
Customer Bulletin 0610 Polyisocyanurate vs. Cellular Glass Insulation
Customer Bulletin 0610 Polyisocyanurate vs. Cellular Glass InsulationCustomer Bulletin 0610 Polyisocyanurate vs. Cellular Glass Insulation
Customer Bulletin 0610 Polyisocyanurate vs. Cellular Glass InsulationJoe Hughes
 
Customer Bulletin 0511 Questions You Should Ask When Selecting Mechanical Ins...
Customer Bulletin 0511 Questions You Should Ask When Selecting Mechanical Ins...Customer Bulletin 0511 Questions You Should Ask When Selecting Mechanical Ins...
Customer Bulletin 0511 Questions You Should Ask When Selecting Mechanical Ins...Joe Hughes
 
Customer Bulletin 0510 Polyisocyanurate vs Polyurethane Insulation
Customer Bulletin 0510 Polyisocyanurate vs Polyurethane InsulationCustomer Bulletin 0510 Polyisocyanurate vs Polyurethane Insulation
Customer Bulletin 0510 Polyisocyanurate vs Polyurethane InsulationJoe Hughes
 

More from Joe Hughes (20)

Qwik-Guide PIR vs XPS Pipe Insulation 0518
Qwik-Guide PIR vs XPS Pipe Insulation 0518Qwik-Guide PIR vs XPS Pipe Insulation 0518
Qwik-Guide PIR vs XPS Pipe Insulation 0518
 
Technical Bulletin 0418 Polyiso vs. XPS Pipe Insulation Systems
Technical Bulletin 0418 Polyiso vs. XPS Pipe Insulation SystemsTechnical Bulletin 0418 Polyiso vs. XPS Pipe Insulation Systems
Technical Bulletin 0418 Polyiso vs. XPS Pipe Insulation Systems
 
QWIK GUIDE: GeoFoam 0218
QWIK GUIDE: GeoFoam 0218QWIK GUIDE: GeoFoam 0218
QWIK GUIDE: GeoFoam 0218
 
Customer Bulletin 0717 ISO C1® Polyisocyanurate Insulation Flame Spread and S...
Customer Bulletin 0717 ISO C1® Polyisocyanurate Insulation Flame Spread and S...Customer Bulletin 0717 ISO C1® Polyisocyanurate Insulation Flame Spread and S...
Customer Bulletin 0717 ISO C1® Polyisocyanurate Insulation Flame Spread and S...
 
LNG Industry Magazine (Commercial Quality Control The Missing Link) Jan 2017
LNG Industry Magazine (Commercial Quality Control The Missing Link) Jan 2017LNG Industry Magazine (Commercial Quality Control The Missing Link) Jan 2017
LNG Industry Magazine (Commercial Quality Control The Missing Link) Jan 2017
 
LNG Industry Magazine (Risk Mitigation Standards) July 2016
LNG Industry Magazine (Risk Mitigation Standards) July 2016LNG Industry Magazine (Risk Mitigation Standards) July 2016
LNG Industry Magazine (Risk Mitigation Standards) July 2016
 
LNG Industry Magazine (Logical Thinking) Feb 2016
LNG Industry Magazine (Logical Thinking) Feb 2016LNG Industry Magazine (Logical Thinking) Feb 2016
LNG Industry Magazine (Logical Thinking) Feb 2016
 
The Role of the Insulation System in Optimizing value in LNG Facilities
The Role of the Insulation System in Optimizing value in LNG FacilitiesThe Role of the Insulation System in Optimizing value in LNG Facilities
The Role of the Insulation System in Optimizing value in LNG Facilities
 
2015 RETA's Exhibition Conference
2015 RETA's Exhibition Conference2015 RETA's Exhibition Conference
2015 RETA's Exhibition Conference
 
2015 SWICA 57th Annual Conference
2015 SWICA 57th Annual Conference2015 SWICA 57th Annual Conference
2015 SWICA 57th Annual Conference
 
2015 Polyurethanes Technical Conference
2015 Polyurethanes Technical Conference2015 Polyurethanes Technical Conference
2015 Polyurethanes Technical Conference
 
2015 ESICA Conference
2015 ESICA Conference2015 ESICA Conference
2015 ESICA Conference
 
Polyisocyanurate Environmental Sustainability
Polyisocyanurate Environmental SustainabilityPolyisocyanurate Environmental Sustainability
Polyisocyanurate Environmental Sustainability
 
2015 SWICA EXPO
2015 SWICA EXPO2015 SWICA EXPO
2015 SWICA EXPO
 
Technical Bulletin 0714 Elastomeric insulation versus polyisocyanurate in low...
Technical Bulletin 0714 Elastomeric insulation versus polyisocyanurate in low...Technical Bulletin 0714 Elastomeric insulation versus polyisocyanurate in low...
Technical Bulletin 0714 Elastomeric insulation versus polyisocyanurate in low...
 
Customer Bulletin 05-15 A Comparison of ISO-C1 and HT-300 Polyisocyanurate In...
Customer Bulletin 05-15 A Comparison of ISO-C1 and HT-300 Polyisocyanurate In...Customer Bulletin 05-15 A Comparison of ISO-C1 and HT-300 Polyisocyanurate In...
Customer Bulletin 05-15 A Comparison of ISO-C1 and HT-300 Polyisocyanurate In...
 
Technical Bulletin 0213 Polyisocyanurate vs. Cellular Glass Insulation
Technical Bulletin 0213 Polyisocyanurate vs. Cellular Glass InsulationTechnical Bulletin 0213 Polyisocyanurate vs. Cellular Glass Insulation
Technical Bulletin 0213 Polyisocyanurate vs. Cellular Glass Insulation
 
Customer Bulletin 0610 Polyisocyanurate vs. Cellular Glass Insulation
Customer Bulletin 0610 Polyisocyanurate vs. Cellular Glass InsulationCustomer Bulletin 0610 Polyisocyanurate vs. Cellular Glass Insulation
Customer Bulletin 0610 Polyisocyanurate vs. Cellular Glass Insulation
 
Customer Bulletin 0511 Questions You Should Ask When Selecting Mechanical Ins...
Customer Bulletin 0511 Questions You Should Ask When Selecting Mechanical Ins...Customer Bulletin 0511 Questions You Should Ask When Selecting Mechanical Ins...
Customer Bulletin 0511 Questions You Should Ask When Selecting Mechanical Ins...
 
Customer Bulletin 0510 Polyisocyanurate vs Polyurethane Insulation
Customer Bulletin 0510 Polyisocyanurate vs Polyurethane InsulationCustomer Bulletin 0510 Polyisocyanurate vs Polyurethane Insulation
Customer Bulletin 0510 Polyisocyanurate vs Polyurethane Insulation
 

Recently uploaded

The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024Rafal Los
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Drew Madelung
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 3652toLead Limited
 
Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slidespraypatel2
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024Scott Keck-Warren
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slidevu2urc
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountPuma Security, LLC
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Allon Mureinik
 
Google AI Hackathon: LLM based Evaluator for RAG
Google AI Hackathon: LLM based Evaluator for RAGGoogle AI Hackathon: LLM based Evaluator for RAG
Google AI Hackathon: LLM based Evaluator for RAGSujit Pal
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesSinan KOZAK
 
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | DelhiFULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhisoniya singh
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityPrincipled Technologies
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘RTylerCroy
 
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...HostedbyConfluent
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking MenDelhi Call girls
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024Results
 

Recently uploaded (20)

The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
 
Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slides
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path Mount
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)
 
Google AI Hackathon: LLM based Evaluator for RAG
Google AI Hackathon: LLM based Evaluator for RAGGoogle AI Hackathon: LLM based Evaluator for RAG
Google AI Hackathon: LLM based Evaluator for RAG
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen Frames
 
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | DelhiFULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024
 

Customer Bulletin 0611 Insulant Impact on Corrosion in Steel Piping Applications Below 32F

  • 1. Page 1 of 7 CUSTOMER BULLETIN 0611 Insulant Impact on Corrosion in Steel Piping Applications Below 32°F BACKGROUND Corrosion is defined by the National Association of Corrosion Engineers as “the deterioration of a material, usually a metal, by reaction with its environment.” Corrosion under insulation (CUI) is not a distinct form of corrosion; rather it refers to the location where pipe wall material deterioration is occurring—underneath the insulation material and on the external surfaces of piping. CUI (and the corrosion of metal jackets and banding which is not addressed herein) is a recognized problem that must be addressed by designers, specifiers, and end-users. CUI can occur under any type of thermal insulation. The type of corrosion will depend on the metallurgy of the pipe as well as the mix of corrosive elements - - understanding that corrosive elements can be introduced during pipe production, pipe shipping/storage, installation, insulation contact, process liquid contact, weather, or other environmental influences. Focusing on CUI, the three most common types of CUI include oxidation (rusting), stress corrosion cracking (SCC), and pitting. Yet there are also several specialized types of CUI such as formicary corrosion1 of copper which in general are not associated with insulated refrigerant systems and therefore not addressed herein. Metals vary considerably in their susceptibility to various types of corrosion. PURPOSE The purpose of this Customer Bulletin is to provide general information on the causes of CUI in steel pipe, which insulants in general terms may be best for low temperature applications, and how to avoid of CUI in steel piping systems operating at service temperatures below 32°F. We also discuss how corrosion differs between the two common types of steel2 used in such piping systems. To keep it simple, we define carbon steel as steel with less than 10.5% chromium, and stainless steel3 as a steel with a minimum of 10.5% chromium content by weight. 1 Formicary (“ants-nest) corrosion may best be described as micro-pitting most common in refrigeration grade copper tubing in HVAC systems although other forms of attack, similar in appearance, have been observed in other alloys. Although poorly understood, attack has been attributed to the growing use of synthetic lubricating oils that were introduced as refrigerant fluids changed, or to vaporous species derived from the immediate surroundings, including volatiles from process fluids. 2 We define “Steel” as an alloy that consists mostly of iron and has a carbon content between 0.2% and 2.1% by weight. 3 Refer to http://www.corrosionist.com/Stainless_Steel_grades.htm. CB 0611 June 2011
  • 2. Page 2 of 7 There are of course many types and grades of both carbon and stainless steels, with varying degrees of susceptibility to various corrosion processes. SUMMARY Too often, discussions of CUI focus only on the insulation, rather than on the broader spectrum of factors that will more likely be the cause of any CUI. At temperatures below 32F, the likelihood of any form of CUI is remote. Yet the majority of mechanical systems spend some time above 32F, such as during outages, so the extent to which an insulant may contribute to CUI must be considered. There are several premises to keep in mind: 1. CUI can in fact occur under any insulant - - some more likely than others a. Insulants with higher Water Absorption and Water Vapor Transmission exacerbate CUI b. Insulants with higher leachable chlorides (or fluorides) can exacerbate CUI (yet such ions must be leachable at the actual temperature presents, and the temperature must be above 32F!) c. CUI is time and temperature dependent 2. CUI can be prevented from occurring by following basic guidelines: - Pre-design identification of environmental factors that could exacerbate CUI, such as rain, acid rain, humidity, “salt air”, wash-down water/chemicals, sprinkler systems, fire control systems, etc.); - Pipe/component design using appropriate metallurgy for the conditions, and control of metallurgy during construction (e.g. welding; pickling/heat treating; avoidance of dissimilar metals in contact; etc.); - Proper specification and application of any pipe coatings; - Proper selection and installation of insulation system materials (insulant, vapor barriers, jackets, mastics, etc.); o This includes compliance with the guidelines of the manufacturers of the various insulation system components as well as the procedures established by a qualified insulation engineer, including for example, keeping the insulation and pipe surfaces dry during the installation process. o Zero-perm vapor barriers can eliminate moisture penetration from the environment. - Operational diligence, including such action as avoidance of excessive impingement of water on pipe during wash-downs, periodic inspection for corrosion, and proper CB 0611 June 2011
  • 3. Page 3 of 7 replacement of the insulation and insulation components after mechanical repairs or inspection. Dyplast is not a piping system designer, so cannot provide credible advice on the overall design of a piping system. We thus focus on insulant selection in the next subsection, and on some general information on corrosion in the remainder of the document - - so the involved parties may better understand the issues and thus better able to communicate with system designers, engineers, and contractors. Insulant Selection Selection of the optimal insulant material is first driven by the long term thermal performance of the insulant, just as the first priority of the piping is to ensure mechanical integrity of the process. Corrosion mitigation must inevitably be a secondary concern, unless the pipe system is likely to be exposed to a chemically intense environment, such as an acid regeneration plant in a steel mill with frequent leaks. In such an environment, cellular glass may be the only insulant that could withstand the chemical onslaught, assuming the chemicals do not include hydrogen fluoride, hydrofluoric acid, or related compounds. As explained in Customer Bulletin 0411, polyisocyanurate (particularly Dyplast’s ISO-C1) is inevitably the optimal selection in the vast majority of piping applications with operating temperatures below 32°F. Polyiso’s thermal conductivity combined with its moisture resistance characteristics result in energy savings and process control advantages that far outweigh any concern over corrosion. The additional good news is that ISO-C1 polyiso is low in leachable chloride. At the low temperatures typical of a polyiso installation, CUI is highly unlikely. In systems where there is frequent cycling above 32F, pipe coatings4 can further mitigate any risk of CUI. CORROSION OF STEEL: GENERAL While dramatically different in nature, the corrosion through oxidation, SCC, and pitting each share one common requirement - - moisture. The corrosion of metals is an electrochemical process. That is, there is an electrical circuit where the exchange of electrons (electricity) is 4 Typical industry practice is to apply an epoxy primer in the following circumstances: 1) for 300 series stainless steel systems operating in a temperature range between 140°F and 300°F or if in a cycling temperature service where the service temperature is between 140° and 300°F for more than 20% of the time; and 2) for carbon steel piping operating at a service temperature between 32°F and 300°F or in cycling temperature service where the service temperature is between 32°F and 300°F for more than 20% of the time shall be at a minimum primer coated with an epoxy coating. Coating manufacturers should be consulted for appropriate coating materials and application methods for the operating temperature range of the equipment. CB 0611 June 2011
  • 4. Page 4 of 7 conducted by chemical reactions in part of the circuit. These chemical reactions occur at the surface of the metal exposed to the electrolyte. Water in the form of liquid or vapor must be present at the surface of the metal for corrosion to occur. Therefore, anything that can be done to prevent moisture (rain, wash-down water, sprinkler systems, condensation, etc.) from reaching the metal surface will help prevent corrosion from occurring. Selecting an insulant with both low water absorption and water vapor transmission, and properly installing a zero-perm vapor barrier with a protective jacket is an appropriate approach in addition to minimizing the external presence of water. The presence of leachable chloride or certain other elements has been found to exacerbate corrosion. Too often the search for the source of such ions has been centered incorrectly on the insulation system components, rather than an external environmental factor which is more often the cause. Chemical exposure is the final major environmental element affecting CUI. Acids and acid gases, hydrochloric acid, sulfuric acid, strong bases (caustics), and salts are aggressive corrosive agents and will both cause and accelerate CUI. The complexity of addressing the reaction of various metals to corrosion by chemicals is beyond the scope of this Customer Bulletin. OXIDATION Oxidation (or simply rusting) is sometimes referred to as uniform corrosion, and is one of the most common mechanisms for corrosion of carbon steel pipe; oxidation does not occur on stainless steel. Oxidation of carbon steel involves four requisites: 1. High temperature 2. Moisture 3. Oxygen 4. Concentration of corrosive ions It is an inescapable fact that iron in the presence of oxygen and water is thermodynamically unstable with respect to its oxides. Because oxidation corrosion is an electrolytic process, the presence of an electrolyte is required. This should not be taken to mean that the steel surface must be awash in water; a very thin adsorbed film of water is all that is required. Oxidation on carbon steel pipe can occur between 32°F and 300°F; the “optimum” temperature range for aggressive corrosion seems to be between 200°F and 240°F5. In this range, there is 5 “Is There a Cure for Corrosion Under Insulation?” Michael Lettich, National Insulation Association, http://www.insulation.org/articles/article.cfm?id=IO051101 CB 0611 June 2011
  • 5. Page 5 of 7 plenty of heat energy but not enough heat to efficiently evaporate moisture before it contacts the equipment surface. Corrosion rates can double for every 18°F rise in temperature6. At the service temperatures considered in this paper (below freezing point of water), the temperature should be insufficient to precipitate corrosion even if water, oxygen, and chloride ions are present. Yet, virtually all piping systems spend some time at ambient temperatures, such as during shutdowns for maintenance. Thus there must still be an exerted effort to minimize moisture and the presence of chloride or other environmental contributors or catalysts An insulation engineer should be consulted when a carbon steel mechanical system cycles into service temperatures between 32°F and 300°F for more than 20% of the time. Typical practice in such circumstance is to apply an epoxy coating, or equivalent. PITTING (OR CREVICE) CORROSION Pitting corrosion is a broad term for corrosion that either begins within pits (non-uniformities) in the pipe surface, or causes pits. Pipe failure can occur if a pit fully penetrates the pipe wall. Pitting can occur in both carbon steel and stainless steel pipes, although it is more commonly associated with stainless steels. Pitting is often considered to be more dangerous than uniform corrosion damage because it is more difficult to detect, predict and design against. Generally, pitting on pipe exteriors can be associated with: - Localized chemical or mechanical damage to the protective oxide films in carbon steel; o chemistry factors such as acidic rain or high concentrations of chloride (as in salt air that has penetrated the insulation system, or indeed from a poorly selected insulant itself in certain circumstances) can cause breakdown of a passive film; and/or - The presence of non-uniformities in the metal structure of the component (e.g. nonmetallic inclusions); and/or - Localized damage to the protective chromium oxide layer on stainless steel (such as at manganese sulfide inclusions on the steel surface) caused by: o chloride or chlorine-containing ions o bromides (fluorides and iodides are not aggressive) o cupric, ferric and mercuric ions (such ions may act in concert with chloride to promote pitting without dissolved O2) [or may indeed prevent pitting in a phosphoric acid environment (e.g. it’s complicated)]; 6 Mechanical Integrity and Carbon Steel Refrigerant Piping, Daniel J. Dettmers and Douglas T. Reindl, ASHRAE Journal, October 2007 CB 0611 June 2011
  • 6. Page 6 of 7 o thiosulphate ions (S2O3) may also promote pitting. Metals that are susceptible to uniform corrosion (e.g. carbon steel) do not tend to suffer from pitting. Thus, carbon steel will corrode uniformly in sea water, while stainless steel will pit. An addition of about 2% of molybdenum increases pitting resistance of stainless steels. Note that crevice corrosion takes place where physical crevices are present, such as at the joint between two overlapping sheets of stainless steel, in the crevice between a stainless steel flange and a non-metallic gasket or under surface deposits. STRESS CORROSION CRACKING SCC is the initiation and propagation of micro-cracks caused by the combined effects of tensile stress coupled with direct surface contact with an enabling chemical7. The stress can be externally applied, thermal, or residual from the manufacturing process. This stress, coupled with a susceptible material and environment, causes small cracks inherent or formed in the material to propagate - - thereby relieving the material’s stress. If the stress level is low, the cracks will self-limit (stop propagating) prior to fully penetrating the pipe wall. If the stress level is high, the cracks have the potential to propagate completely through the entire wall thickness, resulting in a leak. Contrary to conventional wisdom, Stress Corrosion Cracking (SCC) can occur in carbon steels as well as stainless steels. Yet SCC in carbon steel pipes is unusual on the exterior of the pipe since it requires exposure to either hydroxides, nitrates, carbonate, bicarbonates, liquid ammonia, or CO/CO2/H2O at very low temperatures. SCC in carbon steel is more of a concern on the inside the pipe in certain ammonia refrigerant applications/conditions where oxygen may be present. The most common form of SCC in mechanical systems within the temperature ranges addressed in this document is Chloride Stress Corrosion of stainless steel pipe, which involves four requisites: 1. High temperature 2. Chloride (or fluoride or similar) ions 3. Moisture (dissolved oxygen) 4. Metal is under tensile stress Chloride SCC can occur between 140°F and 300°F for 300 series stainless steel. The "optimum" temperature range for aggressive corrosion on 300 series stainless steel seems to 7 American Society of Materials International. 2003. ASMI Handbook Volume 13a, Corrosion: Fundamentals, Testing, and Protection, “Selecting Materials to Prevent or Control Corrosion.” CB 0611 June 2011
  • 7. Page 7 of 7 be between 200°F and 240°F. Chloride SCC is most commonly overcome by using a duplex stainless steel, such as 2205, or a grade with a higher nickel content, such as a 6% Mo material or high-nickel alloys like Alloy 825 (N08825). Ferritic stainless steels are very resistant to SCC but grades with equivalent pitting resistance to the austenitic grades have other major drawbacks. CB 0611 June 2011