SlideShare a Scribd company logo
1 of 74
Pipe Design and Production
Marine Piping Systems

                  Ship Piping Systems
Bilge System


               Bilge System
Bilge System

• Basic requirement is to provide effective drainage
  to all dry spaces and at the same time prevent
  water from entering the spaces through this
  system.
• Discharge of oily water from machinery spaces is
  to comply with MARPOL Annex 1
• Oily water is treated in an oily-water separator
  before being allowed to be discharged.
• Discharge water must be monitored with purity
  not to exceed ppm set by MARPOL.
Bilge System
Bilge main diameter, dm
    d m = 1.68 × L × ( B + D ) + 25   (mm)

 L = length of ship
 B = Breadth
 D = Depth

Branch bilge main diameter, db

    d b = 2.15 × l × ( B + D ) + 25   (mm)

 l = length of compartment
Bilge System
Bilge pump capacity, Q
                      2
                    dm
          Q = 5.75 × 3            (m3/h)
                    10

• Two bilge pumps are required
• Suctions are arranged such that water can be
  pumped out when ship is inclined 5°
• Arrangement must be such that water cannot pass
  from sea or ballast system into dry spaces through
  the bilge system
Oily-water Separator
Ballast System




Ballast System
Ballast System
• For safe operation, at least two ballast pumps are
  to be connected to ballast tanks.
• Stripping eductor can also be used for emptying
  the bilges in cargo holds with 2 non-return valves
  between hold and system
• Ship side valve material must not of grey cast iron
  and to direct mechanical manual operate
Air and Sounding Systems
Purposes
• to secure ventilation of tanks, cofferdam and
  tunnels to prevent over-pressurizing and vacuum
  (air pipes)
• to ascertain the level of liquid in tanks, cofferdam
  and tunnels (Sounding pipes)
• Vent pipes need to prevent flooding of spaces
  through their upper ends
• Vent pipes need to safely prevent flammable
  liquids or vapours due to their fire hazards
Air and Sounding Systems
Machinery Spaces
• Heavy fuel oil overflow tank has short self-closing
  type sounding pipe
• HFO overflow tank air pipe is led to open deck as
  required.
• Lubricating oil sump tank air pipe may end inside
  machinery space but away from ignition sources
Air and Sounding Systems
Machinery Spaces
• Air or overflow pipes internal are are normally
  required to be 1.25 times the area of respective
  filling pipes for a tank.
• Velocity in the air pipe is not to exceed 4 m/s
  when using one pump for one tank.
Air and Sounding Systems
Air and Sounding Systems
Fire-Fighting Systems
Fire-fighting System
Fire-Fighting Systems

Three groups:
• Fire Main
  – Seawater as fire extinguishing medium
  – At least two fire pumps and are located in two different
    compartments
  – An international shore connection is provided at port
    and starboard for external water supply
  – System is tested with at least streams of water directed
    from one fire pump.
  – Pressure relief valve is fitted to mains to protect sudden
    over-pressure.
Fire-Fighting Systems

Three groups:
• Carbon Dioxide system
  – Dry fire protection
  – Used in compartments that have potential for fire:
    engine room, emergency generator room, paint locker
    and galley hood
  – System is equipped with audio and visual alarm to alert
    personnel to evacuate
  – Prior to CO2 release, ventilation fans and fire damper to
    be shut.
Fire-Fighting Systems

Three groups:
• Sprinkle system
  – Wet fire protection mainly for accommodation area
  – System is filled with fresh water and pressurized by
    compressed air
  – Subsequently, water is supplied from fire main
  – Sprinkle and fire main systems are separated by an
    alarm check valve.
  – When the pressure in the sprinkle drops below the fire
    main fire pressure, the fire main pressure will overcome
    the internal pressure of the valve lift and automatically
    push open to accommodate the fire main.
Fuel Oil Systems

Main concerns
• Fire hazards
   –   Flash point
   –   Insulation
   –   Remote control of fuel oil valves
   –   Stopping of pumps
   –   Collection of drains from leaks
• Materials
   – Fuel oil pipes and their valves and fittings is required to
     be of steel or other fire-resistance materials
FO Storage and Transfer



                 FO Storage and Transfer
FO Storage and Transfer

Important concerns
• Overflow pipes
• Quick-closing valves
• Drain to waste oil tanks (spill trays)
• Level gauge with heat-resistant glass for sounding
• Remote control of fuel oil valves
• Insulation of hot surfaces where fuel oil leaks
  (possibly in a spray form) is possible
HFO Settling Tank
HFO Service Tank
Quick-closing Valves
FO Supply to Engine




FO System
FO Supply to Engine

Main components
• Storage (bunkers)
• Transfer pump
• Settling tank
• Heater
• Purifier
• Service tank
• Filter
• Viscosity controller
• Return Tank (10 to 15 minutes engine operation)
HFO Duplex Filter
HFO Transfer Pump
HFO Heater
HFO Separator
HFO Separation System
Diesel Fuel Separation System
Diesel Fuel Separation System
Lubricating Oil Storage and Transfer
Lubricating Oil Storage and Transfer

Main components
• Filling from deck to tanks
• Main LO storage tank to deliver to ME sump tank
• Quick-closing valves operable from outside ER
  where valves are below top of tanks (not
  applicable for small tanks below 0.5 m3)
• Air pipes may terminate inside ER provided their
  openings do not constitute a fire hazard
• Duplex filters (or self-cleaning) are used without
  interrupting operations
Lubricating Oil Circulation System
Lubricating Oil Service Tank
Lubricating Oil Pump
Lubricating Oil Filter – Self-cleaning
Lubricating Oil Filter – Self-cleaning
Lubricating Oil System - Thermostatic Valve
Shell-and-Tube LO Cooler
Lubricating Oil Purifier
Lubricating Oil Purifier
Seawater Cooling System
Seawater Cooling System

Arrangement
• Conventional and Central cooling
• High and low sea chests
• Suctions are arranged from two sea inlets
  preferably on the opposite sides of the ships
• Filters can be cleaned without interrupting the
  water supply in the system.
• Temperature controlled three-way valves to re-
  circulate water when the water is cold
Seawater Cooling System
Overboard Discharge
Freshwater Cooling System
Freshwater Cooling System
Freshwater Cooling System

Arrangement
• Freshwater from engine is delivered to freshwater
  generator (evaporator)
• Pressure in the system is regulated by he
  expansion tank
• Temperature-controlled three-way valves to allow
  re-circulation
• High-temperature circuit (jacket cooler), low-
  temperature circuit (lubricating oil)
Freshwater Generator (Evaporator)
Freshwater Cooler (Plate-type)
Jacket Water Pump
Freshwater Header Tank
Compressed Air System
Compressed Air System

• Normally three systems
   – Starting air
   – Service air
   – Control air
• Require two main compressors to charge two air
  receivers from atmospheric within one hour
• Capacity of receivers sufficient to produce:
   – 12 starts for reversible engines
   – 6 starts for non-reversible engines
   – 3 starts for auxiliary engines
Compressed Air System

• No connections to other machinery between air
  compressors and main air receivers
• Emergency air compressor can be diesel driven or
  power supplied from emergency generator
• Pressure reduction stations and filters are required
  to be duplicates
• Safety relief valves are fitted at receivers and set at
  10% above operating pressure
• Compressed air line is classes as Class II due to
  high pressure.
Air Compressors
Air Receivers
Auxiliary Air
  Receiver
Emergency Air Receiver
Control Air Dryer (Refrigerant-type)
Pressure-reducing Station
Domestic Water System
Domestic
 Water
System
Domestic Water System

• Freshwater is made by Freshwater generator
  (evaporator)
• Delivery of water to accommodation from
  hydrophore units is by compressed air
• Domestic water is sterilized before consumption
• Domestic water is heated and then circulated (by
  hot-water circulating pumps)
• Domestic water is also used by HFO, DO and LO
  separators
Hydrophore
   unit
Domestic Water Heater
Power Generating System
Generator System
                     Diesel
                   Generator
                    System
Steam System




                Steam
               System
Steam System

• Normally divided into:
   – Feed water systems
   – Steam supply
      • For heating tanks
      • For heating pipelines
      • To heat exchangers
   – Condensate
• Heat of exhaust gas is recovered in economizer to
  generate steam
• Diesel propulsion system is normally fitted with
  an auxiliary boiler
Steam System

• Steam with pressure above 7 bar or temperature
  above 170°C are considered Class II piping.
• Steam with pressure above 16 bar or temperature
  above 300°C is of Class I piping.
• With respect to materials for valves and fittings in
  Class II piping system, grey cast iron may not be
  used up to ND 200, pressure up to 13 bar and
  temperature up to 250°C
Auxiliary Boiler
Cargo Pump Turbine and Condenser

More Related Content

What's hot (20)

Auxiliary Boilers
Auxiliary Boilers Auxiliary Boilers
Auxiliary Boilers
 
Incinerator and MARPOL Requirements
Incinerator and MARPOL RequirementsIncinerator and MARPOL Requirements
Incinerator and MARPOL Requirements
 
Marine Fresh Water Generators
Marine Fresh Water Generators Marine Fresh Water Generators
Marine Fresh Water Generators
 
Fresh Water Generator
Fresh Water GeneratorFresh Water Generator
Fresh Water Generator
 
Marine boilers
Marine boilersMarine boilers
Marine boilers
 
Two stroke main engine piston overhaul
Two stroke main engine piston overhaulTwo stroke main engine piston overhaul
Two stroke main engine piston overhaul
 
Ship Rudder
Ship RudderShip Rudder
Ship Rudder
 
Sewage treatment plant on a ship
Sewage treatment plant on a ship Sewage treatment plant on a ship
Sewage treatment plant on a ship
 
Auxiliary marine machinery systems
Auxiliary marine machinery systemsAuxiliary marine machinery systems
Auxiliary marine machinery systems
 
bilge,ballast & fire pump
 bilge,ballast & fire pump bilge,ballast & fire pump
bilge,ballast & fire pump
 
Boiler Mountings
Boiler MountingsBoiler Mountings
Boiler Mountings
 
Stern Tube and Shafting Arrangements
Stern Tube and Shafting ArrangementsStern Tube and Shafting Arrangements
Stern Tube and Shafting Arrangements
 
Ship Construction by Jayan Pillai
Ship Construction by Jayan PillaiShip Construction by Jayan Pillai
Ship Construction by Jayan Pillai
 
101103077-Tanker-Pipeline-Systems.ppt
101103077-Tanker-Pipeline-Systems.ppt101103077-Tanker-Pipeline-Systems.ppt
101103077-Tanker-Pipeline-Systems.ppt
 
Marine Steering Gear and SOLAS Requirements
Marine Steering Gear and SOLAS RequirementsMarine Steering Gear and SOLAS Requirements
Marine Steering Gear and SOLAS Requirements
 
Marine Boilers
Marine BoilersMarine Boilers
Marine Boilers
 
Introduction of Boiler
Introduction of BoilerIntroduction of Boiler
Introduction of Boiler
 
Inspections On Board
Inspections On BoardInspections On Board
Inspections On Board
 
Continuous machinery survey
Continuous machinery surveyContinuous machinery survey
Continuous machinery survey
 
Heat Exchangers by Hanif Dewan
Heat Exchangers by Hanif DewanHeat Exchangers by Hanif Dewan
Heat Exchangers by Hanif Dewan
 

Similar to Marine piping systems

marine piping system and Pipe Design and Production
marine piping system and Pipe Design and Productionmarine piping system and Pipe Design and Production
marine piping system and Pipe Design and ProductionInkiPasung
 
Module 1 heating - steam (wecompress.com)
Module 1   heating - steam (wecompress.com)Module 1   heating - steam (wecompress.com)
Module 1 heating - steam (wecompress.com)DeepakSingh1807
 
Central heating level 3
Central heating level 3Central heating level 3
Central heating level 3Barry Everard
 
AUXILIARY POWER SUPPLY SCHEME FOR THERMAL POWER PLANT
AUXILIARY POWER SUPPLY SCHEME FOR THERMAL POWER PLANTAUXILIARY POWER SUPPLY SCHEME FOR THERMAL POWER PLANT
AUXILIARY POWER SUPPLY SCHEME FOR THERMAL POWER PLANTsheikhalfiya
 
Concept NoteR1.ppt
Concept NoteR1.pptConcept NoteR1.ppt
Concept NoteR1.pptMILIND569137
 
flare-system-design-for-oil-and-gas-installations-chris-park.pdf
flare-system-design-for-oil-and-gas-installations-chris-park.pdfflare-system-design-for-oil-and-gas-installations-chris-park.pdf
flare-system-design-for-oil-and-gas-installations-chris-park.pdfjustmaul1
 
Hydro Power Plant Auxaleries
Hydro Power Plant AuxaleriesHydro Power Plant Auxaleries
Hydro Power Plant AuxaleriesMahajan Saurabh
 
flare-system-design-for-oil-and-gas-installations-chris-park.pptx
flare-system-design-for-oil-and-gas-installations-chris-park.pptxflare-system-design-for-oil-and-gas-installations-chris-park.pptx
flare-system-design-for-oil-and-gas-installations-chris-park.pptxssuser940899
 
EC8DE5D2-3B41-4599-8A5D-AB833F9397F5.pdf
EC8DE5D2-3B41-4599-8A5D-AB833F9397F5.pdfEC8DE5D2-3B41-4599-8A5D-AB833F9397F5.pdf
EC8DE5D2-3B41-4599-8A5D-AB833F9397F5.pdfsuryanshsingh836763
 
Class 7- Cooling system.pptx
Class 7- Cooling system.pptxClass 7- Cooling system.pptx
Class 7- Cooling system.pptxFrancisSenapati
 
AC System Components.ppt
AC System Components.pptAC System Components.ppt
AC System Components.pptVishalGarje7
 
C3.2.2. Topside Gas Compression_2020
 C3.2.2. Topside Gas Compression_2020 C3.2.2. Topside Gas Compression_2020
C3.2.2. Topside Gas Compression_2020David Seow
 
Hvac Equipment and Maintenance
Hvac Equipment and MaintenanceHvac Equipment and Maintenance
Hvac Equipment and MaintenanceVaisakh Subash
 
Tipsfor energyconservationforindustries
Tipsfor energyconservationforindustriesTipsfor energyconservationforindustries
Tipsfor energyconservationforindustriesApurv Pandit
 
Diesel Power Plant
Diesel Power Plant Diesel Power Plant
Diesel Power Plant dishantpati
 

Similar to Marine piping systems (20)

marine piping system and Pipe Design and Production
marine piping system and Pipe Design and Productionmarine piping system and Pipe Design and Production
marine piping system and Pipe Design and Production
 
Module 1 heating - steam (wecompress.com)
Module 1   heating - steam (wecompress.com)Module 1   heating - steam (wecompress.com)
Module 1 heating - steam (wecompress.com)
 
Central heating level 3
Central heating level 3Central heating level 3
Central heating level 3
 
AUXILIARY POWER SUPPLY SCHEME FOR THERMAL POWER PLANT
AUXILIARY POWER SUPPLY SCHEME FOR THERMAL POWER PLANTAUXILIARY POWER SUPPLY SCHEME FOR THERMAL POWER PLANT
AUXILIARY POWER SUPPLY SCHEME FOR THERMAL POWER PLANT
 
Concept NoteR1.ppt
Concept NoteR1.pptConcept NoteR1.ppt
Concept NoteR1.ppt
 
flare-system-design-for-oil-and-gas-installations-chris-park.pdf
flare-system-design-for-oil-and-gas-installations-chris-park.pdfflare-system-design-for-oil-and-gas-installations-chris-park.pdf
flare-system-design-for-oil-and-gas-installations-chris-park.pdf
 
fire fighting System
fire fighting Systemfire fighting System
fire fighting System
 
Hydro Power Plant Auxaleries
Hydro Power Plant AuxaleriesHydro Power Plant Auxaleries
Hydro Power Plant Auxaleries
 
Oil production 2
Oil production 2Oil production 2
Oil production 2
 
flare-system-design-for-oil-and-gas-installations-chris-park.pptx
flare-system-design-for-oil-and-gas-installations-chris-park.pptxflare-system-design-for-oil-and-gas-installations-chris-park.pptx
flare-system-design-for-oil-and-gas-installations-chris-park.pptx
 
EC8DE5D2-3B41-4599-8A5D-AB833F9397F5.pdf
EC8DE5D2-3B41-4599-8A5D-AB833F9397F5.pdfEC8DE5D2-3B41-4599-8A5D-AB833F9397F5.pdf
EC8DE5D2-3B41-4599-8A5D-AB833F9397F5.pdf
 
Class 7- Cooling system.pptx
Class 7- Cooling system.pptxClass 7- Cooling system.pptx
Class 7- Cooling system.pptx
 
cdu and vdu unit
cdu and vdu unitcdu and vdu unit
cdu and vdu unit
 
AC System Components.ppt
AC System Components.pptAC System Components.ppt
AC System Components.ppt
 
C3.2.2. Topside Gas Compression_2020
 C3.2.2. Topside Gas Compression_2020 C3.2.2. Topside Gas Compression_2020
C3.2.2. Topside Gas Compression_2020
 
Hvac Equipment and Maintenance
Hvac Equipment and MaintenanceHvac Equipment and Maintenance
Hvac Equipment and Maintenance
 
MODULE - 5 (2).pdf
MODULE - 5 (2).pdfMODULE - 5 (2).pdf
MODULE - 5 (2).pdf
 
Tipsfor energyconservationforindustries
Tipsfor energyconservationforindustriesTipsfor energyconservationforindustries
Tipsfor energyconservationforindustries
 
Dry riser system
Dry riser systemDry riser system
Dry riser system
 
Diesel Power Plant
Diesel Power Plant Diesel Power Plant
Diesel Power Plant
 

More from kmsu

Slideshare
SlideshareSlideshare
Slidesharekmsu
 
Propulsion%20system %203rd[1]
Propulsion%20system %203rd[1]Propulsion%20system %203rd[1]
Propulsion%20system %203rd[1]kmsu
 
Hydrodinamic[1]
Hydrodinamic[1]Hydrodinamic[1]
Hydrodinamic[1]kmsu
 
Hooshmand[1]
Hooshmand[1]Hooshmand[1]
Hooshmand[1]kmsu
 
Offshore platform design
Offshore platform designOffshore platform design
Offshore platform designkmsu
 
Marine fire safety
Marine fire safetyMarine fire safety
Marine fire safetykmsu
 
Tug launching by air bag
Tug launching by air bagTug launching by air bag
Tug launching by air bagkmsu
 
Multiframe intro
Multiframe introMultiframe intro
Multiframe introkmsu
 
Naval museum of bushehr
Naval museum of bushehrNaval museum of bushehr
Naval museum of bushehrkmsu
 
Khazar lake
Khazar lakeKhazar lake
Khazar lakekmsu
 
Arvandan
ArvandanArvandan
Arvandankmsu
 
Pp
PpPp
Ppkmsu
 
Erfan
ErfanErfan
Erfankmsu
 
Delvar
DelvarDelvar
Delvarkmsu
 
Maxsurf
MaxsurfMaxsurf
Maxsurfkmsu
 
هندسه پروانه
هندسه پروانههندسه پروانه
هندسه پروانهkmsu
 
Modern ships
Modern shipsModern ships
Modern shipskmsu
 
Marine Production Technology
Marine Production TechnologyMarine Production Technology
Marine Production Technologykmsu
 
Ocean energy
Ocean energyOcean energy
Ocean energykmsu
 
مراحل اجرای شمع های درجا ریز
مراحل اجرای شمع های درجا ریزمراحل اجرای شمع های درجا ریز
مراحل اجرای شمع های درجا ریزkmsu
 

More from kmsu (20)

Slideshare
SlideshareSlideshare
Slideshare
 
Propulsion%20system %203rd[1]
Propulsion%20system %203rd[1]Propulsion%20system %203rd[1]
Propulsion%20system %203rd[1]
 
Hydrodinamic[1]
Hydrodinamic[1]Hydrodinamic[1]
Hydrodinamic[1]
 
Hooshmand[1]
Hooshmand[1]Hooshmand[1]
Hooshmand[1]
 
Offshore platform design
Offshore platform designOffshore platform design
Offshore platform design
 
Marine fire safety
Marine fire safetyMarine fire safety
Marine fire safety
 
Tug launching by air bag
Tug launching by air bagTug launching by air bag
Tug launching by air bag
 
Multiframe intro
Multiframe introMultiframe intro
Multiframe intro
 
Naval museum of bushehr
Naval museum of bushehrNaval museum of bushehr
Naval museum of bushehr
 
Khazar lake
Khazar lakeKhazar lake
Khazar lake
 
Arvandan
ArvandanArvandan
Arvandan
 
Pp
PpPp
Pp
 
Erfan
ErfanErfan
Erfan
 
Delvar
DelvarDelvar
Delvar
 
Maxsurf
MaxsurfMaxsurf
Maxsurf
 
هندسه پروانه
هندسه پروانههندسه پروانه
هندسه پروانه
 
Modern ships
Modern shipsModern ships
Modern ships
 
Marine Production Technology
Marine Production TechnologyMarine Production Technology
Marine Production Technology
 
Ocean energy
Ocean energyOcean energy
Ocean energy
 
مراحل اجرای شمع های درجا ریز
مراحل اجرای شمع های درجا ریزمراحل اجرای شمع های درجا ریز
مراحل اجرای شمع های درجا ریز
 

Recently uploaded

Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024The Digital Insurer
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonAnna Loughnan Colquhoun
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationRadu Cotescu
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...Neo4j
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreternaman860154
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonetsnaman860154
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processorsdebabhi2
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slidespraypatel2
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdfhans926745
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking MenDelhi Call girls
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slidevu2urc
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfsudhanshuwaghmare1
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...apidays
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?Igalia
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountPuma Security, LLC
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfEnterprise Knowledge
 

Recently uploaded (20)

Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreter
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slides
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path Mount
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
 

Marine piping systems

  • 1. Pipe Design and Production
  • 2. Marine Piping Systems Ship Piping Systems
  • 3. Bilge System Bilge System
  • 4. Bilge System • Basic requirement is to provide effective drainage to all dry spaces and at the same time prevent water from entering the spaces through this system. • Discharge of oily water from machinery spaces is to comply with MARPOL Annex 1 • Oily water is treated in an oily-water separator before being allowed to be discharged. • Discharge water must be monitored with purity not to exceed ppm set by MARPOL.
  • 5. Bilge System Bilge main diameter, dm d m = 1.68 × L × ( B + D ) + 25 (mm) L = length of ship B = Breadth D = Depth Branch bilge main diameter, db d b = 2.15 × l × ( B + D ) + 25 (mm) l = length of compartment
  • 6. Bilge System Bilge pump capacity, Q 2 dm Q = 5.75 × 3 (m3/h) 10 • Two bilge pumps are required • Suctions are arranged such that water can be pumped out when ship is inclined 5° • Arrangement must be such that water cannot pass from sea or ballast system into dry spaces through the bilge system
  • 9. Ballast System • For safe operation, at least two ballast pumps are to be connected to ballast tanks. • Stripping eductor can also be used for emptying the bilges in cargo holds with 2 non-return valves between hold and system • Ship side valve material must not of grey cast iron and to direct mechanical manual operate
  • 10. Air and Sounding Systems Purposes • to secure ventilation of tanks, cofferdam and tunnels to prevent over-pressurizing and vacuum (air pipes) • to ascertain the level of liquid in tanks, cofferdam and tunnels (Sounding pipes) • Vent pipes need to prevent flooding of spaces through their upper ends • Vent pipes need to safely prevent flammable liquids or vapours due to their fire hazards
  • 11. Air and Sounding Systems Machinery Spaces • Heavy fuel oil overflow tank has short self-closing type sounding pipe • HFO overflow tank air pipe is led to open deck as required. • Lubricating oil sump tank air pipe may end inside machinery space but away from ignition sources
  • 12. Air and Sounding Systems Machinery Spaces • Air or overflow pipes internal are are normally required to be 1.25 times the area of respective filling pipes for a tank. • Velocity in the air pipe is not to exceed 4 m/s when using one pump for one tank.
  • 13. Air and Sounding Systems
  • 14. Air and Sounding Systems
  • 16. Fire-Fighting Systems Three groups: • Fire Main – Seawater as fire extinguishing medium – At least two fire pumps and are located in two different compartments – An international shore connection is provided at port and starboard for external water supply – System is tested with at least streams of water directed from one fire pump. – Pressure relief valve is fitted to mains to protect sudden over-pressure.
  • 17. Fire-Fighting Systems Three groups: • Carbon Dioxide system – Dry fire protection – Used in compartments that have potential for fire: engine room, emergency generator room, paint locker and galley hood – System is equipped with audio and visual alarm to alert personnel to evacuate – Prior to CO2 release, ventilation fans and fire damper to be shut.
  • 18. Fire-Fighting Systems Three groups: • Sprinkle system – Wet fire protection mainly for accommodation area – System is filled with fresh water and pressurized by compressed air – Subsequently, water is supplied from fire main – Sprinkle and fire main systems are separated by an alarm check valve. – When the pressure in the sprinkle drops below the fire main fire pressure, the fire main pressure will overcome the internal pressure of the valve lift and automatically push open to accommodate the fire main.
  • 19. Fuel Oil Systems Main concerns • Fire hazards – Flash point – Insulation – Remote control of fuel oil valves – Stopping of pumps – Collection of drains from leaks • Materials – Fuel oil pipes and their valves and fittings is required to be of steel or other fire-resistance materials
  • 20. FO Storage and Transfer FO Storage and Transfer
  • 21. FO Storage and Transfer Important concerns • Overflow pipes • Quick-closing valves • Drain to waste oil tanks (spill trays) • Level gauge with heat-resistant glass for sounding • Remote control of fuel oil valves • Insulation of hot surfaces where fuel oil leaks (possibly in a spray form) is possible
  • 25. FO Supply to Engine FO System
  • 26. FO Supply to Engine Main components • Storage (bunkers) • Transfer pump • Settling tank • Heater • Purifier • Service tank • Filter • Viscosity controller • Return Tank (10 to 15 minutes engine operation)
  • 34. Lubricating Oil Storage and Transfer
  • 35. Lubricating Oil Storage and Transfer Main components • Filling from deck to tanks • Main LO storage tank to deliver to ME sump tank • Quick-closing valves operable from outside ER where valves are below top of tanks (not applicable for small tanks below 0.5 m3) • Air pipes may terminate inside ER provided their openings do not constitute a fire hazard • Duplex filters (or self-cleaning) are used without interrupting operations
  • 39. Lubricating Oil Filter – Self-cleaning
  • 40. Lubricating Oil Filter – Self-cleaning
  • 41. Lubricating Oil System - Thermostatic Valve
  • 46. Seawater Cooling System Arrangement • Conventional and Central cooling • High and low sea chests • Suctions are arranged from two sea inlets preferably on the opposite sides of the ships • Filters can be cleaned without interrupting the water supply in the system. • Temperature controlled three-way valves to re- circulate water when the water is cold
  • 50. Freshwater Cooling System Arrangement • Freshwater from engine is delivered to freshwater generator (evaporator) • Pressure in the system is regulated by he expansion tank • Temperature-controlled three-way valves to allow re-circulation • High-temperature circuit (jacket cooler), low- temperature circuit (lubricating oil)
  • 56. Compressed Air System • Normally three systems – Starting air – Service air – Control air • Require two main compressors to charge two air receivers from atmospheric within one hour • Capacity of receivers sufficient to produce: – 12 starts for reversible engines – 6 starts for non-reversible engines – 3 starts for auxiliary engines
  • 57. Compressed Air System • No connections to other machinery between air compressors and main air receivers • Emergency air compressor can be diesel driven or power supplied from emergency generator • Pressure reduction stations and filters are required to be duplicates • Safety relief valves are fitted at receivers and set at 10% above operating pressure • Compressed air line is classes as Class II due to high pressure.
  • 60. Auxiliary Air Receiver
  • 62. Control Air Dryer (Refrigerant-type)
  • 65. Domestic Water System • Freshwater is made by Freshwater generator (evaporator) • Delivery of water to accommodation from hydrophore units is by compressed air • Domestic water is sterilized before consumption • Domestic water is heated and then circulated (by hot-water circulating pumps) • Domestic water is also used by HFO, DO and LO separators
  • 66. Hydrophore unit
  • 69. Generator System Diesel Generator System
  • 70. Steam System Steam System
  • 71. Steam System • Normally divided into: – Feed water systems – Steam supply • For heating tanks • For heating pipelines • To heat exchangers – Condensate • Heat of exhaust gas is recovered in economizer to generate steam • Diesel propulsion system is normally fitted with an auxiliary boiler
  • 72. Steam System • Steam with pressure above 7 bar or temperature above 170°C are considered Class II piping. • Steam with pressure above 16 bar or temperature above 300°C is of Class I piping. • With respect to materials for valves and fittings in Class II piping system, grey cast iron may not be used up to ND 200, pressure up to 13 bar and temperature up to 250°C
  • 74. Cargo Pump Turbine and Condenser