Kotlin Multiplatform & Compose Multiplatform - Starter kit for pragmatics
Grøn betong II – Ett danskt projekt om klimatreducerad betong - Claus Vestergaard, Teknologisk Institut.
1. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
Danish Innovation Consortium (2014-2018)
Green Transition of Cement and Concrete
Production in Denmark
2. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
Companies
Aalborg Portland A/S
Sweco A/S
Rambøll Danmark A/S
MT Højgaard A/S
Unicon A/S
Dansk Beton Fabriksbetonforeningen
A/S Ikast Betonvarefabrik
Betonværket Brønderslev A/S
DK Beton A/S
Frejlev Cementstøberi A/S
Gammelrand Beton A/S
IBF Beton Nordvestjylland A/S
K.G. Beton A/S
NCC Roads, Bornholms Betonværk A/S
Skagen Cementstøberi A/S
Thisted-Fjerritslev Cementvarefabrik A/S
Unicon A/S
VK Beton og Byggemarked A/S
Wewers Belægningssten A/S
Participants
Knowledge and dissemination
Teknologisk Institut (DTI)
Københavns Erhvervsakademi
Erhvervsakademi Sjælland
Erhvervsakademiet Lillebælt
Via University College – Campus Horsens
Center for Betonuddannelse (AMU
Nordjylland)
Academia (Research)
DTU Byg
Other
Energistyrelsen
InnoBYG network
Building owners
Vejdirektoratet
Banedanmark
Femern A/S
3. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
Purpose and motivation
Denmark has a long tradition for Green Concrete
since the late 1990ies
Cement manufacturer under pressure to develop
new green binder materials
General lack of SCM’s in the market
Sustainability is getting high on the agenda
Need to collaborate across the “specifier –
designer – producer – supplier” chain
4. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
Activities
Test and demonstrate new binder systems in full scale
Development of transport model for concrete (DTU)
for durability modelling
Develop and apply the methodology for the use of
performance-based specifications/requirements
instead of deemed-to-satisfy requirements
…
5. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
Activities …cont.
Assess the potential for CO2 reductions
Full-scale demonstration projects
(three bridges and an indoor wall)
Establish exposure sites for long-term observations
Workshops for concrete students
6. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
Danish concrete branch organisation has
launched a sustainability initiative:
50 % reduction of CO2 footprint per unit concrete
in 2030 compared with today (2019)
Aalborg Portland is working on new cement
type for 2020
Based on CEM II/B-M (LL-Q)
Danish EN 206 DK NA has opened up for more
use of bio-coal-FA and limestone filler
What is next step ?
7. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
Marine exposure sites and a highway between traffic lanes
Exposure sites for long-term
durability data
Hirtshals, West Coast Rødby near Femern
9. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
Funktionsbaseret optimering
Motorway bridge – Rødby, 2016
Trial castings. Unicon, MT Højgaard
Bridge elements to be lifted in place
Extension of railway bridge
10. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
XC2, XC3, XC4 + XF1 (air entrainment), V/C < 0.55
Requirement on min. strength class C30/37
Danish requirements on binder
Cement C
(EN 197-1)
SCM’s
(if used)
Limitations when
calculating V/C
Other remarks
CEM I (min.
42.4 MPa)
+ FA + MS
k = 0.5 and 2.0
FA/C ≤ 0.33
MS/C ≤ 0.11
Normal approach in DK.
Clinker ratio typically > 80%
CEM II/A-V
CEM II/B-V
+ MS
k = 2.0
MS/C ≤ 0.11 Normally not used
CEM II/A-L
CEM II/A-LL
+ FA + MS
k = 0.5 and 2.0
FA/C ≤ 0.33
MS/C ≤ 0.11
CEM II/A-LL is used in DK precast
Clinker ratio as low as 60 %
CEM I (min.
52.5 MPa)
+ GCC type A
+ GCC type B
GCC/C ≤ 0.25 (k = 1.0)
GCC/C ≤ 0.10 (k = 1.0)
GCC = Ground limestone filler
(fulfilling certain requirements)
11. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
XD2, XD3, XS3, V/C < 0.40 and strength class C40/50
For XF4 air void structure shall be good
For XA3 sulphate resistant cement, CEM I - SR5
Danish requirements on binder
Cement C
(EN 197-1)
SCM’s
(if used)
Limitations when
calculating V/C
Other remarks
CEM I (min.
42.4 MPa)
+ FA + MS
k = 0.5 and 2.0
FA/C ≤ 0.33
MS/C ≤ 0.11
Normal approach in DK.
Clinker ratio typically > 80%
CEM II/A-V
+ MS
k = 2.0
MS/C ≤ 0.11 Normally not used.
CEM II/A-L
CEM II/A-LL
+ FA + MS
k = 0.5 and 2.0
FA/C ≤ 0.33
MS/C ≤ 0.11
Only for XD3 without frost.
Clinker ratio as low as 60 %
Normally not used.
12. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
Two concrete applications
Bridge concrete XD3, XS3, XF4, XA3 - C35/40
Indoor concrete XC1, C25/30, SCC
Compare the candidate concretes with
reference mix designs
CEM I 42.5 SR5, Fly ash FA/C = 0.15 for the
bridge application, V/C = 0.37, C40/50
CEM I 52.5 N, Fly ash FA/C = 0.25 for the
building application, V/C = 0.69, C25/30, SCC
How did we investigate ?
13. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
Performance-based development for hardened
concrete:
Strength and E-modulus
Freeze-thaw resistance (only for bridge)
Chloride migration at different times up to
one year (only for bridge)
Carbonation resistance (only for indoor)
Fresh properties:
Slump/flow, air content
Viscosity, stickiness
How did we investigate ?
14. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
For the bridge applications CEM I 52.5 N was used:
FA/C = 0.8. Clinker only 55% of binder.
FA/C = 0.5 and LL/C = 0.35. Clinker only 54%.
FA/C = 0.5 and no LL. up to 0.8. Clinker 67%.
Mixes with limestone and calcined clay:
CEM I / LL / Q = 86% / 2% / 12% CEM II/A-M (Q-LL)
CEM I / LL / Q = 86% / 6% / 8% CEM II/A-M (Q-LL)
Plus mixes with FA addition 10 to 20% of binder
For the building application
CEM I / LL / Q = 65% / 14% / 21% CEM II/B-M (Q-LL)
Resulting mixes
15. Claus Vestergaard Nielsen, Svensk Betongdagen, 2019-11-21
www.gronbeton.dk
www.baeredygtigbeton.dk
CLN@DTI.dk
Questions… ?
More information