1) TORISHIMA is a leading Japanese pump manufacturer founded in 1919, with a mission to provide high-quality pumping equipment and services.
2) The document provides product catalogs and selection tables to help customers choose the appropriate pump for their application. Pumps are categorized by type and suitable industries which they serve.
3) TORISHIMA offers a wide range of pumps including end-suction, double-suction, multi-stage, mixed-flow, submersible, and specialized pumps that can be used in industries like energy, water treatment, chemical, and more.
2. Innovative solutions coupled with
expertise in pumping technology
TORISHIMA is a leading pump manufacturer, founded in 1919 in Osaka, Japan. Our primary objective is to contribute to
society as a quality provider of pumping equipment and services. We continue to strive to be the market leader in our field.
Our on-going investment in research and development highlights our commitment to provide the best technology for our
customers. Our mission is always to listen to our customers, understand their needs and their expectations.
TORISHIMA
MAIN PUMPS
SELECTION TABLE
General specification ranges for 50Hz
and 60Hz types are shown below.
Pumps for Fresh Water
4,000
3,000
MHG
2,000
MHB
1,500
Total head H · m
1,200
MHD
850
MSH
500
400
250
MSH-T
MML
CDM
100
MMO
CDKTV
MMK
50
30
CFV
10
CE
CA Series
5
ISV
0.2
10
5
CPC
CPCN
CA Series
20
40
Capacity Q · m3/min
60
80
Non-Clogging Pumps
Chart for Selecting Pumps by Application
Multi-Stage Pumps ............................................... 20
Energy Industry....................................................... 3
Specialized Pumps ............................................... 22
Municipal Water Works, Industrial Water Works
Small Capacity Water Works, Desalination Plant ... 5
Mixed-Flow Pumps ............................................... 23
Sewerage, Agriculture, Irrigation, River Water ....... 7
Submersible Pumps.............................................. 25
Axial-Flow Pumps ................................................. 24
Regional Development, Urban Development ......... 9
Mechanical Seals..................................................... 29
General Industry ................................................... 13
Service Solutions .................................................... 30
3500
35.0
HLV,HLAV
10.0
CHR
5.0
CPW
CPR
1.5
CERS
0.1
5
20
30
Capacity Q · m3/min
50
70
100
CNA
20
5
10
Capacity Q · m3/min
15
300
100
0.1
CSV
10
15
40
50
Capacity Q · m3/min
Miscellaneous Pumps ........................................... 27
Chemical Industry ................................................. 11
60
0.1
2500
MMTV
Total head H · m
Double-Suction Pumps ......................................... 19
Total head H · m
Torishima Main Pumps Selection Table.................. 2
500 700 1000 1500
500
CNP
Main Pumps List
End-Suction Pumps .............................................. 15
100 300
Vertical Pumps for Chemical Industries
100
Content
Discharge pressure MPa(kgf/cm2)G
Total head H · m
CPR
0.1
30
Hot Water Circulating Pumps
300
200
20
Capacity Q · m3/min
Chemical Process Pumps
100
SPV
2
3. Energy Industry
Condensate pump for combined cycle power plant (MMTV)
Vaporizing pumps for LNG plant (SPV)
Barrel type super critical boiler feed pump for coal fired power plant (MHB)
Super critical pressure boiler circulating pump for thermal power plant (HLV)
Ring section boiler feed pump for combined cycle power plant (MHG)
Circulating water pump for coal fired thermal power plant (SPV)
Page
°C
Max. Operating Temperature
MPa
Max. Operating Pressure
m
1200
150
1
80
15
CE
200 to
2100
300
90
1
140
15
CHR
50 to
300
1940
125
10.8
325
16
CNP
50 to
200
850
100
1
250
17
CPC
32 to
250
1560
220
2.45
350
17
CPCN
32 to
250
1560
150
2.45
200
18
CPR
25 to
400
4320
270
4
400
18
CPW
40 to
250
1440
200
6.3
280
18
CSV
32 to
200
810
100
2.5
350
18
CDM, CDMV
200 to
33000
1400
300
1.4
80
19
CDKS
200 to
3000
500
300
350
19
CDKY
125 to
3480
400
160
210
19
CDKTV
500 to
20000
1500
100
100
19
MHB
80 to
200
2000
4200
42
200
20
MHG
40 to
250
1400
4200
42
200
20
MHD
80 to
200
300
1200
14
180
20
MMK
40 to
350
1800
150
5.4
230
21
MML
40 to
350
1800
500
5.4
230
21
MMTV
EndSuction
Pumps
DoubleSuction
Pumps
MultiStage
Pumps
40 to
400
2900
490
3.9
200
22
40 to
400
6000
180
32
420
22
300 to
80000
2800
100
80
23
150 to
9000
1000
70
50 to
800
4800
40
25 to
200
400
200
Specialized HLV, HLAV
Mixed-Flow SPV
Pumps
SMRV
Submersible T/B
Pumps
F/TB
3
Cooling by
Seawater
LNG, LPG
Utility
Geothermal
Hydropower
Oil
LNG
Sizes
CAM
Utility
15
Fire-Fighting
80
Crude oil
1
Underground
Water Drainage
100
Stripping
600
32 to
250
Oil Product
Outlet
32 to
200
Products
Gas
CAL
Coal
Max. Total Heads
m3/h
Horizontal/Vertical
mm
Horizontal/Vertical
Vertical
Max. Capacities
Oil Storage
Power
Generation
Applications
Vertical
Horizontal
Ground Tank
Chart for Selecting Pumps by Application
Horizontal
Secondary Application
Underground
Tank
Main Application
3.2
25
40
26
26
4
4. Water supply pumps for potable water distribution pumping station (CDM)
Long-distance potable water transmission pumps (CDM)
Brine recirculation pumps for MSF desalination plant (CDKTV)
Various seawater pumps for MSF desalination plant (CDM, SPV, SPSY)
High pressure seawater feed pump for RO desalination plant (MSH-T)
High pressure seawater feed pump for RO desalination plant (MSH)
Max. Operating Pressure
Max. Operating Temperature
Page
°C
Max. Total Heads
1
80
15
CAM
1200
150
1.6
80
15
CAS
32 to
250
1200
150
1.6
80
15
CFV
150 to
210000
5000
100
CPC
32 to
250
1560
220
2.45
350
17
CDM, CDMV
200 to
33000
1400
300
1.4
80
19
CDKS
200 to
3000
500
300
350
19
CDKTV
500 to
20000
1500
100
100
19
MSH
100 to
1500
300
750
21
MSH-T
200 to
3000
350
800
21
MHH
150 to
300
800
800
21
MHA
125 to
200
800
800
21
MMK
40 to
350
1800
150
5.4
230
21
MML
40 to
350
1800
500
5.4
230
21
MMO, MMOV
32 to
65
130
400
4
140
22
SPV
300 to
80000
2800
100
80
23
SPSY
350 to
20000
1200
50
23
SMIV
EndSuction
Pumps
DoubleSuction
Pumps
MultiStage
Pumps
MixedFlow
Pumps
400 to
4500
700
6
25
400 to
4200
700
14
25
150 to
9000
1000
70
25
25 to
250
400
200
26
40 to
300
660
90
26
SMSV
Submersible SMV
Pumps
F/TB
F/VC, F/VD
F/UW, F/SP
5
Sizes
100
Product Water
600
32 to
250
Back Wash
32 to
200
Filtered Water
CAR
High Pressure
Feed
15
Product Water
80
Seawater Feed
1
Brine Blow Down
100
Brine
Recirculation
600
Distribution
32 to
300
Products
Supply
CAL
Intake
Max. Capacities
MPa
Horizontal/Vertical
m
Horizontal/Vertical
Vertical
m3/h
Vertical
Horizontal
Seawater
Desalination
(RO)
Applications
Seawater
Desalination
(MSF)
Chart for Selecting Pumps by Application
Horizontal
Secondary Application
mm
Main Application
MunicipaI
Waterworks
IndustriaI
Waterworks
Small Scale
Waterworks
Municipal Water Works
Industrial Water Works
Small Capacity Water Works
Desalination Plant
16
6
5. Storm water drainage pumps for sewage treatment plant (SPV)
Drainage pumps for agriculture (SP)
Irrigation pumps (CDM)
Sludge transfer pumps for sludge disposal plant (CNP)
Waste water transfer pumps for sewage treatment plant (CFV-SM)
Sewage pumps for sewage treatment plant (CFV)
Horizontal/Vertical
Vertical
Horizontal/Vertical
River Water
Agriculture
Max. Total Heads
Max. Operating Pressure
Max. Operating Temperature
Page
150
1.6
80
15
CE
200 to
2100
300
90
1
140
15
CFV
150 to
210000
5000
100
16
CFV-SM
200 to
3000
600
50
16
CNA
50 to
200
500
70
1
140
17
CNP
50 to
250
850
100
1
250
17
CNS, CNSV
EndSuction
Pumps
80 to
250
660
70
105
17
80
19
Double-Suction
CDM, CDMV
Pumps
Sizes
1200
Water Utilization
CAM
FIood Control,
Water Supply
15
Irrigation, Sprinkler
80
Drainage
1
Agricultural Water
100
Storm Water
Drainage
Small Capacity
Sewerage
600
32 to
250
Sludge
Disposal Plant
32 to
300
Products
Sewage
Disposal Plant
CAL
Sewage Transfer
Plant
Max. Capacities
Sewerage
mm
Applications
°C
Vertical
Horizontal
MPa
Chart for Selecting Pumps by Application
Horizontal
Secondary Application
m
Main Application
m3/h
Sewerage
Agriculture
Irrigation
River Water
750
21
MSH-T
200 to
3000
350
800
21
MMK
40 to
350
1800
150
5.4
230
21
MML
40 to
350
1800
500
5.4
230
21
32 to
65
130
400
4
140
22
SP
400 to
36000
2000
9
SPV
300 to
80000
2800
100
SPSY
350 to
20000
1200
50
23
SPSX
250 to
1380
350
17
24
IS
400 to
36000
2000
5
24
ISV
400 to
186000
4600
5
24
SMI, SMS
400 to
210000
5000
8
25
SMIV
400 to
4500
700
6
25
400 to
4200
700
14
25
50 to
800
4800
40
F/TB
25 to
200
400
200
26
F/VC, F/VD
F/UW, F/SP
AxialFlow
Pumps
100 to
1500
300
MMO, MMOV
MixedFlow
Pumps
300
MSH
MultiStage
Pumps
200 to
33000
1400
40 to
300
660
90
26
10
28
SubSMSV
mersible
Pumps T/B, T/C, T/N
Miscellaneous
SNK
Pumps
7
400 to
18000
3500
1.4
23
80
40
23
26
8
6. Regional Development
Urban Development
Pumps for air conditioning system for building facility (CAL)
Cooling water pumps for district heating and cooling system (CDM)
Boiler feed pumps for district heating and cooling system (MML)
Cooling water pumps for district heating and cooling system (CDM)
Cooling water pumps for air conditioning facility (CE)
Boiler feed pumps for district heating and cooling system (MMO)
Max. Operating Pressure
Max. Operating Temperature
Page
°C
Max. Total Heads
150
1.6
80
15
CAS
32 to
1200
250
150
1.6
80
15
200 to
2100
300
90
1
140
15
32 to
65
42
65
1
100
16
CNA
50 to
200
500
70
1
140
17
CPC
32 to
1560
250
220
2.45
350
17
CPCN
32 to
1560
250
150
2.45
200
18
200 to
33000
1400
300
1.4
80
19
MMK
40 to
1800
350
150
5.4
230
21
MML
40 to
1800
350
500
5.4
230
21
MMO, MMOV
32 to
65
130
400
4
140
22
50 to
4800
800
40
40
26
25 to
200
400
200
26
F/UW, F/SP
40 to
300
660
90
26
K/LP
25 to
100
84
60
100
27
15 to
80
72
300
90
27
25 to
200
300
40
40
28
40 to
150
600
75
80
28
EndCE
Suction
Pumps CEBS
Double-Suction
CDM, CDMV
Pumps
MultiStage
Pumps
T/B, T/C, T/N
Submersible F/TB
Pumps F/VC, F/VD
Miscel- N/WR
laneous
Pumps TE/O
S/T
9
Sizes
32 to
1200
250
Fountains
CAM
Sewage
Treatment
15
Drainage
80
Water Supply
1
Sewage
Treatment
100
Drainage
600
Water Supply
CAR
Vacuum Supply Water,
Supply Water, Raw Water
15
Boiler Feed
80
Hot Water
1
Cold Water
100
Cooling Water
600
32 to
200
Fire-Fighting
32 to
200
Water Supply and
Drainage, Sanitation
CAL
Products
Air Conditioning
Max. Capacities
mm
MPa
Horizontal/Vertical
m
Horizontal/Vertical
Vertical
Park and Resort
Facilities
Intelligent
Building
District Heating
and Cooling
Applications
Vertical
Horizontal
Airport and
Harbor Facilities
Chart for Selecting Pumps by Application
Horizontal
Secondary Application
m3/h
Main Application
1
10
7. Chemical Industry
Process pumps for chemical plant (CPC)
Process pumps for DMT plant (CPC)
Cooling water pumps for petrochemical plant (CDM)
Boiler feed pump for petrochemical plant (MHD)
Lifting pump for chemical plant (CDKS)
Cooling water pumps for oil refinery plant (CPC)
Max. Operating Pressure
Max. Operating Temperature
Page
°C
Max. Total Heads
15
CAM
32 to
250
1200
150
1.6
80
15
CAS
32 to
250
1200
150
1.6
80
15
CE
200 to
2100
300
90
1
140
15
CERS
32 to
100
300
98
1.4
340
16
CNP
50 to
250
850
100
1
250
17
CPC
32 to
250
1560
220
2.45
350
17
CPCN
32 to
250
1560
150
2.45
200
18
CPR
25 to
400
4320
270
4
400
18
CPW
40 to
250
1440
200
6.3
280
18
CSV
EndSuction
Pumps
32 to
200
810
Sizes
80
Coal Conversion
1
Refinery
100
Utility
600
Process
CAR
Utility
15
Process
80
Utility
1
Process
100
Utility
600
32 to
200
Process
32 to
200
Products
Utility
CAL
Process
Max. Capacities
Oil and Coal
Products
MPa
Horizontal/Vertical
m
Horizontal/Vertical
Vertical
m3/h
Vertical
Horizontal
Bio-Chemical
Fine-Chemical
Chemical
Fertilizer
Inorganic
Chemical
Applications
Petro-Chemical
Chart for Selecting Pumps by Application
Horizontal
Secondary Application
mm
Main Application
100
2.5
350
18
200 to
33000
1400
300
1.4
80
19
200 to
3000
500
300
350
19
MHB
80 to
200
2000
4200
42
200
20
MHG
40 to
250
1400
4200
42
200
20
MHD
80 to
200
300
1200
14
180
20
MMK
40 to
350
1800
150
5.4
230
21
MML
40 to
350
1800
500
5.4
230
21
MMTV
40 to
400
3.9
200
22
Double- CDM
Suction
Pumps CDKS
MultiStage
Pumps
Mixed-Flow
SPV
Pumps
Submersible
T/B, T/C, T/N
Pumps
Miscellaneous
N/WR
Pumps
11
2900
490
300 to
80000
2800
100
80
23
50 to
800
4800
40
40
26
15 to
80
72
300
90
27
12
8. General Industry
Water supply pumps for machinery plant (CAL)
Treated water pumps for beverage plant (CAR)
Process pumps for beer brewery plant (CAR)
Furnace cooling water pump for steel plant (CDM)
Cooling water pump in paper mill (CDM)
Plating cooling water pumps for steel plant (CAL)
Max. Operating Pressure
Max. Operating Temperature
Page
°C
Max. Total Heads
80
15
CAM, CAS
1200
150
1.6
80
15
CE
200 to
2100
300
90
1
140
15
CEBS
32 to
65
42
6.5
1
100
16
CERS
EndSuction CNA
Pumps
CNP
32 to
100
300
98
1.4
340
16
50 to
200
500
70
1
140
17
50 to
200
850
100
1
250
17
CNS, CNSV
80 to
250
660
70
105
17
CPC
32 to
250
1560
220
2.45
350
17
CPCN
32 to
250
1560
150
2.45
200
18
CPW
40 to
250
Utility
Process
Utility
Sizes
1
Dock Drainage
100
Food
600
32 to
250
Drainage
32 to
200
Utility
CAL, CAR
Products
Waste Water
Treatment
Max. Capacities
MPa
Horizontal/Vertical
m
Horizontal/Vertical
Vertical
m3/h
Vertical
Horizontal
mm
Paper & Pulps
Process
Descaling
Motor Car
Machinery
Ceramics
New Materials
Cooling Water
Water Supply
Nonferrous
Metal
Water Intake,
Water Supply
Applications
Iron and Steel
Chart for Selecting Pumps by Application
Horizontal
Secondary Application
Shipbuilding
Main Application
1440
200
6.3
280
18
200 to
33000
1400
300
1.4
80
19
MHG
40 to
250
1400
4200
42
200
20
MHD
80 to
200
300
1200
14
180
20
MMK
40 to
350
1800
150
5.4
230
21
MML
40 to
350
500
1800
5.4
230
21
MMO, MMOV
32 to
65
130
400
4
140
22
Specialized HLV/HLAV
40 to
400
6000
180
32
420
22
Mixed-Flow
SPV
Pumps
300 to
80000
2800
100
80
23
40 to
350
1000
230
50 to
800
4800
40
25 to
200
400
200
26
40 to
300
660
90
26
15 to
80
72
300
90
27
25 to
200
300
40
40
28
50 to
250
780
70
Double-Suction
CDM
Pumps
MultiStage
Pumps
S/M
SubT/B, T/C, T/N
mersible
Pumps F/TB
F/VC, F/VD
F/UW, F/SP
N/WR
Miscellaneous TE/O
Pumps
O/PS
13
26
40
26
28
14
9. CEBS
Pressing stainless end-suction volute pump
5
USgpm
20
80 100
End-Suction
End-Suction
End-Suction Pumps
300
80
200
50
100
A motor block pump made by pressing stainless
steel. The liquid contact areas are all made of
stainless steel so as to be highly resistant to
corrosion. The pump motor unit design allows to
be compact and light-weight and easy to handle.
Applications
Hot water supply / Hot water circulation
in building facilities,
Various processes in food industries,
Water and hot water supply for general industries,
To prevent breakage from freezing for pump
facilities in cold areas, and others
CAL (Cast Iron),
CAR (Stainless Steel)
10bar end-suction volute pump
Taking advantage of our existing pump designs,
CAL and CAR are totally optimized design pumps
which adopt the efficient impeller design. The
components focus on interchangeability.
20
In common with CAL and CAR as CA series, CAM
and CAS are totally optimized design pumps which
adopt the efficient impeller design.
Applications
Feed / Drainage water for general industries, Feed /
Drainage water / Various processes for chemical /
food industries, Cold / Hot water circulation in district
heating / cooling plants, Water pumping,
Fire-fighting, Water intake / Distribution / Supply for
water works, Industrial water, and others
CE
4000 6000
490
300
30
H
m
H
ft
20
5
2
A single- or two-stage end-suction volute pump.
Various materials and structural designs employed
to meet specification requirements for a variety of
applications from fresh water, chemicals and heat
transfer.
H
ft
10
2
1
0.2
1
Capacity
Total Head
Temperature
Pressure
Size
CERS
55
5
Q l/s
Q m3/h
1
10
25
20
90
3
up to 42 m /h / 165 USgpm
up to 65 m / 210 ft
up to 100ºC / 210°F
up to 1 MPa / 10 bar / 145 psi
32 to 65 mm
USgpm
200
2000
4000
300
100
20
Q l/s
Q m3/h 50
100
10
Capacity
Total Head
Temperature
Pressure
Size
20
200
500
350
9001400
up to 600 m3/h / 2,640 USgpm
up to 100 m / 320 ft
-10 to 80°C / -50 to 170°F
up to 1 MPa / 10 bar / 145 psi
32 to 200 mm
USgpm
100
150
1000
4000 6500
490
100
End-suction volute pump for heat
transfer oil
50
100
Specialized for heat transfer oil.
Effective air-cooled design leads to no requirement
for cooling at shaft sealing or bearing to 340°C
heat transfer oil.
H
m
H
ft
5
10
5
2
300
30
100
H
m
H
ft
Applications
Dry / Agitator / Heating systems
for chemical industries,
Oven / Dry / Heating systems for food industries,
Dry / Heating systems for general industries, and
others
CFV, CFV-SM
Vertical mixed-flow volute pump
Vertical mixed-flow volute pump with motor
2
3.3
10
50
12
Capacity
Total Head
Temperature
Size
500
100
100
Q l/s
Q m3/h
100
500
1000
3
up to 300 m /h / 1,320 USgpm
up to 98 m / 320 ft
up to 340ºC / 640°F
32 to 100 mm
USgpm
20000
200000
1000000
300
50
100
20
5
5
2
0.8
2
10
Q l/s
Q m3/h
Capacity
Total Head
Temperature
Pressure
Size
20
100
100
20
50
200
100
500
350
9001500
up to 1,200 m3/h / 5,280 USgpm
up to 150 m / 490 ft
-40 to 80ºC / -100 to 170°F
up to 1.6 MPa / 16 bar / 230 psi
32 to 250 mm
USgpm 500
2000
10000
400
End-suction volute pump
30
H
m
100
Applications
Feed / Drainage water for general industries, Feed /
Drainage water / Various processes for chemical /
food industries, Cold / Hot water circulation in district
heating / cooling plants, Water pumping,
Fire-fighting, Water intake / Distribution / Supply for
water works, Industrial water, and others
16bar end-suction volute pump
1000
100
0.8
CAM (Cast Iron),
CAS (Stainless Steel)
USgpm
100
150
50
10
Applicable for wide range from low head to high
head. CFV-SM are a design of water resistant
motor and pump. The design enables it to
operate when a pump room is flooded. In
addition, CFV-SM doesn’t require intermediate
shaft and thus reduces construction cost.
Applications
Sewage transfer, Rain water drainage, Water
intake / Distribution / Boosting for water works,
Water pumping / Drainage for agriculture, and
others
CHR
End-suction volute pump for hot
water circulation
80
50
H
m
H
ft
5
H
m
50
CFV-SM
H
ft
5
10
2
30
500
100
2000
20000
20000
50000
200000
CFV
120 to 210,000 m3/h / 520 to 924,000 USgpm
3 to 100 m / 10 to 320 ft
150 to 5,000 mm
Capacity
Total Head
Size
50
5000
Q l/s
Q m3/h
200
USgpm
1000
Applicable mainly for hot water circulation of
forced-circulation boilers. The forced cooling
system is applied to the bearing bracket, stuffing
box and base plate.
CFV
CFV-SM
180 to 3,000 m3/h / 790 to 13,200 USgpm
up to 50 m / 160 ft
200 to 600 mm
5000
150
100
300
H
ft
50
100
20
CFV
100
H
m
50
10
5
Applications
Water intake / Distribution / Supply / Boosting /
Clarification for water works,
Various processes for chemical industries,
Water pumping / Drainage for agriculture,
Boiler feed pump,
Heat medium circulation,
Heater drain, and others
15
2
1.2
10
10
40
Capacity
Total Head
Temperature
Pressure
Size
Q l/s
Q m3/h
100
400
3
650
2000
up to 2,100 m /h / 9,240 USgpm
up to 90 m / 295 ft
up to 140ºC / 280°F (340ºC /
640°F for heat medium)
up to 1 MPa / 10 bar / 145 psi
200 to 300mm
Applications
Hot water circulation in forced-circulation boilers
in thermal power plants,
Petrochemical industries,
Coal gasification plants,
Oil refinery, and others
20
5
2
5
10
20
50
Capacity
Total Head
Temperature
Pressure
Size
Q l/s
Q m3/h
100
500
500
1500
3
up to 1,940 m /h / 8,530 USgpm
up to 125 m / 410 ft
up to 325°C / 615°F
up to 10.8 MPa / 108 bar / 1,560 psi
50 to 300 mm
16
10. USgpm
100
500
1000
2000
250
Non-clogging end-suction volute pump
30
50
200
150
10
USgpm
100
1000
7000
500
100
H
m
CPCN
End-suction volute pump for process
40
80
End-Suction
End-Suction
CNA
300
The discharge opening of the non-clogging
impeller is produced especially wide to permit free
passing of any solids measuring 50 to 70% of the
pump nozzle size.
10
H
ft
4
Applications
Sewage transfer,
Transfer / Drainage of liquids containing sludge
for general industries,
Transfer of grain and water mixtures,
Transfer of cellulous pulp of less than 2.5% B.D.
free from air, and others
CNP
Non-clogging End-suction volute pump
Conforms to ISO2858, compact, durable and
reliable based on CPC type. The design corresponding to space saving installation and high
suction pressure fits in building facilities, district
cooling and heating, energy related industries.
Applications
Transfer of corrosive liquids / abrasive liquids /
chemical drainage including rough mixtures
for chemical industries,
Transfer / Drainage of solid mixtures for food /
general industries, and others
CNS, CNSV(Vertical)
2
2.5
10
10
50
50
120
200
170
500
9∼500 m3/h / 39 to 2,200 USgpm
up to 70 m / 230 ft
up to 140°C / 280°F
50 to 200mm
Capacity
Total Head
Temperature
Size
55
25
Q l/s
Q m3/h 100
USgpm
200
2000
400
100
Applications
Cooling water circulation in building facilities, Cool /
Hot water / Cooling water circulation for district
cooling and heating, Water pumping, Fire-fighting,
Cooling systems / Water feed for deaerator /
Condensate / Drain in energy industries, Water
feed / Drainage for general industries
CPR
4000
100
H
m
H
ft
CPC
H
ft
5
0.5
0
5
3
20
Capacity
Total Head
Temperature
Pressure
Size
200
1800
up to 1,560 m3/h / 6,860 USgpm
up to 150 m / 490 ft
-40 to 200°C / -100 to 390°F
up to 2.45 MPa / 24.5 bar / 355 psi
32up to 250 mm
USgpm
100
5
500
50
Q l/s
Q m3/h
1000
10000
1000
300
End-suction volute pump for process
500
Simple and durable design providing high
reliability. Widely used for oil refinery, petrochemical, and general industries. Series with
inducer for low NPSH req. also available.
200
H
m
H
ft
30
50
10
20
5
10
2
3.3
10
12
50
Capacity
Total Head
Temperature
Size
30
100
Q l/s
Q m3/h
270
500
Applications
Processes in oil refinery / petrochemical / general
industries
USgpm
300
200
100
H
m
H
ft
10
30
End-suction volute pump for hot water
circulation
20
Q l/s
10
Q m3/h
Capacity
Total Head
Temperature
Size
10
100
200
100
600
1000
Centerline pump foot mounted. Mainly used as
feed pump or circulation pump of hot water in
large-size heating systems.
Applications
Feed water / Circulation in high pressure hot
water generating plants
10
USgpm
1000
7000
700
Vertical centrifugal volute pump
End-suction volute pump for process
up to 4,320 m3/h / 19,000 USgpm
up to 270 m / 885 ft
-70 to 400°C / - 150 to 750°F
up to 4 MPa / 40 bar / 580 psi
25 to 400 mm
500
5000
500
H
ft
H
m
30
100
10
30
10
3
0.35
2
1
5
60
Q l/s 20
5 Q m3/h 25
Capacity
Total Head
Temperature
Pressure
Size
CSV
4000
1000
100
up to 660 m /h / 2,900 USgpm
up to 70 m / 230 ft
up to 105°C / 220°F
80 to 250 mm
200
1200
Q m3/h
USgpm
50
300
3
300
100
Q l/s
100
Capacity
Total Head
Temperature
Pressure
Size
CPW
3000
10
10
960
100
3
0
3
1
up to 850 m3/h / 3,740 USgpm
up to 100 m / 320 ft
-30 to 250°C / -20 to 480°F
50 to 200mm
30
Applications
Sewage / Sludge transfer,
Pulp / Black liquid / White liquid transfer,
Transfer / Drainage of solid mixtures in food /
general industries, and others
50
100
End-suction volute pump with screw
impeller
Specially designed to handle crude sewage
containing heavily contaminated solid and
long-fibre admixtures liable to twist or bunch.
High efficiency and high energy saving.
100
H
m
10
50
Five kinds of standardized impellers available
according to liquid. Applicable in various
industries. The back pull-out structure and high
interchangeability of this pump providing ease of
maintenance.
50
100
100
500
500
2000
up to 1,440 m3/h / 6,300 USgpm
up to 200 m / 670 ft
up to 280°C / 530°F
up to 6.3 MPa / 63 bar / 910 psi
40 to 250 mm
100 USgpm 300
1000
2000
6000
100
200
50
300
Conforms to ISO2858. A wide range of structural
designs of material and seals meet various
specification requirements as process pump for
chemical and general industries.
50
100
H
m
50
H
ft
5
Applications
Cooling systems / Water feed for deaerator /
Condensate / Drain in energy industries,
Processes in petrochemical / chemical industries,
Water feed / Drainage for general industries
17
0.5
0
5
3
20
Capacity
Total Head
Temperature
Pressure
Size
Q l/s
Q m3/h
5
500
50
200
3
1800
up to 1,560 m /h / 6,860 USgpm
up to 220 m / 720 ft
up to 350°C / 660°F
up to 2.45 MPa / 24.5 bar / 355 psi
32 to 250 mm
Standardized vertical pump, making full use of
the features of various horizontal volute pumps
covering a wide range of specifications.
Applications
Pumping / Drainage of pit water in construction
facilities / chemical / steel / power generating /
pulp / food industries, and others
100
H
m
50
10
H
ft
15
2
3
10
15
50
Capacity
Total Head
Temperature
Size
100
Q l/s
100 Q m3/h 300
900
3
up to 810 m /h / 3,560 USgpm
up to 100 m / 320 ft
-100 to 350°C / -210 to 660°F
32 to 200 mm
18
11. Double-Suction Pumps
Multi-Stage Pumps
Double-Suction
Axially split double-suction pump
The world’s most advanced high efficiency pump achieved
by design to match the double suction and
three-dimensional impeller with the latest hydraulics.
Simple disassembly of upper half casing without disturbing
pipe work enables ease of maintenance and inspection.
Applications
Water intake / Distribution / Boosting / Circulation /
Drainage / Fire-fighting in energy industries, Cooling water
circulation for district heating and cooling, Water intake /
Distribution / Boosting for general industries, Water intake /
Distribution / Water supply / Boosting in seawater
desalination / water works / sewage, Irrigation for
agriculture, Drainage, Pipe-line boosting, and others
CDKY, CDKS
USgpm 5000
200
500
10000
30000
MHB
50000 100000 150000
1000
300
100
Radially split barrel casing pump
The barrel casing is fully welded to the pipe work
and supported at its centerline on a fabricated
steel base plate. The inner cartridge, which
contains all pump components except the barrel
and main stud bolts, is removable from the barrel
as a complete unit for ease of maintenance.
300
H
ft
H
m
100
30
CDM
5
50
300
Q l/s
500
2000
Total Head
Temperature
Size
500
Q m3/h
USgpm
1000
3000
10000
10000
5000
MHG
500
1000
8000
13000
2000
7000
H
ft
H
m
1000
3000
500
1500
200
5
20
20
50
100
700
700
100
Q l/s
Q m3/h
200
2000
3
up to 2,000 m /h / 8,800 USgpm
up to 4,200 m / 13,800 ft
up to 230°C / 440°F
up to 42 MPa / 420 bar / 6,090 psi
up to 7,000min-1
80 to 200 mm
Capacity
Total Head
Temperature
pressure
Speed
Size
CDMV
10000 20000
USgpm
4200
Applications
Boiler feed in thermal power plants,
High pressure feed water in various industries,
and others
30000
180 to 33,000 m3/h /
790 to 145,200 USgpm
3 to 300 m / 10 to 980 ft
up to 80°C / 175°F
200 to 1,400 mm
Capacity
500
1000
100
USgpm
500
1000
4000
300
CDKS
The rotating parts can be taken out by removing
the side cover in axial direction. Suitable for
handling high temperature and pressure liquids
in chemical plants and power plants. CDKY
mainly used as booster pump for boiler feed
pump and hot water circulation pump.
Applications
Processes in power / chemical / pulp industries,
and others
50
100
100
200
120
5000
Q l/s
500 Q m3/h
500
40
2000
1000
2000
5000
CDKY
up to 3,480 m3/h / 15,300 USgpm
up to 160 m / 520 ft
up to 210°C / 410°F
125 to 400 mm
15000
30000
USgpm
CDKY
Applications
Boiler feed in power plants,
High pressure feed water in various industries,
and others
350
100
Applications
Brine recirculation / Brine blow down
in seawater desalination plants,
Hot well / Large volume condensate
in geothermal power plants
19
80
H
ft
H
m
200
50
150
40
350
1000
850
2000
1500
Q m3/h 5000
Capacity
Total Head
Temperature
Size
Q l/s
10000
4000
20000
up to 20,000 m3/h / 220,000 USgpm
up to 100 m / 320 ft
up to 100°C / 210°F
500 to 1,500 mm
1000
3000
1500
200
5
20
20
50
Capacity
Total Head
Temperature
Pressure
Speed
Size
20
700
400
100
Q l/s
Q m3/h
200
1000
up to 1,400 m³/h / 6,100 USgpm
up to 4,200 m / 13,800 ft
up to 200°C / 390°F
up to 42 MPa / 420 bar / 6,090 psi
up to 7,000 min-1
40 to 250 mm
USgpm
100
2000
1000
Horizontal multistage ring section pump
Radially split ring-section high-pressure
multistage diffuser type pump achieving high
efficiency and low NPSH. No warming through
required enabling rapid start-up.
Applications
Boiler feed in power plants,
High pressure feed water in RO desalination /
various industries, and others
2000
5000
H
ft
1000
300
The hydraulic design of the double-suction
impeller offering low-shut off head, low NPSH
and high speed. Mainly applicable for brine
recirculation in seawater desalination plants and
condensate in geothermal power plants when
severe suction condition with large capacity and
high head required.
H
ft
CDKS
up to 3,000 m3/h / 13,200 USgpm
up to 300 m / 960 ft
up to 350°C / 660°F
200 to 500 mm
MHD
80000
7000
H
m
500
100
Capacity
Total Head
Temperature
Size
Vertical double-suction pump with canister
Radially split ring-section high-pressure
multistage diffuser type pump. No warming
through required enabling rapid start-up.
H
ft
30
10
20
CDKTV
400
CDKY
13000
Horizontal multistage ring section pump
100
H
m
4200
2000
Horizontal radially split double-suction pump
1000
Multi-Stage
CDM, CDMV(Vertical)
H
m
2000
400
1000
200
500
100
1
3
10
Capacity
Total Head
Temperature
Pressure
Speed
Size
10
Q l/s
3
Q m /h
100
100
140
500
3
up to 300 m /h / 1,320 USgpm
up to 1,200 m / 4,000 ft
up to 180°C / 350°F
up to 14 MPa / 140 bar / 2,030 psi
up to 7,000 min-1
80 to 200 mm
20
12. MSH, MSH-T(twin-suction)
Horizontal axially split multistage volute pump
The axially split design offers ease of
maintenance of rotating equipment without
removing the lower casing. MSH-T covering high
head range is twin-suction structure to satisfy
high suction capability.
2000
5000 USgpm 10000
3000
MMO,
MMOV(Vertical)
15000
800
2500
Multistage ring section pump
MSH-T
H
ft
MSH-T
H
m
Compact and light-weight. Pump feet integrally cast
onto bearing housings, allowing free orientation of
both suction and discharge nozzles. No cooling of
shaft seals required up to 140°C liquid.
1500
100
200
800
3500
2000 USgpm 3000
1000
MMTV
4000
800
2000
500
100
H
ft
100
10
20
Applications
Boiler feed / Condensate / Distribution for general
industries, Water intake / Distribution / Water supply /
Boosting for water works, Feed water / Drainage in
building facilities, Cooling water / Hot and Cold water
circulation, Water pumping / Drainage for agriculture,
and others
MSH-T
up to 3,000 m3/h / 13,200 USgpm
up to 800 m / 2,600 ft
200 to 350 mm
MSH
up to 1,500 m3/h / 6,600 USgpm
up to 750 m / 2,460 ft
100 to 300 mm
1000
500
3
1
MSH
1000
3000
2000
500
2500
2
30
Q m3/h
USgpm
100
500
70
250
100
up to 130 m3/h / 570 USgpm
up to 400 m / 1,320 ft
up to 140°C / 280°F
32 to 65 mm
Capacity
Total Head
Temperature
Size
20
10
Q l/s
10
1000
10000
Ring casing type
1000
Vertical multistage pump with canister
H
ft
100
The axially split design offers ease of
maintenance of rotating equipment without
removing the lower casing. Applicable for high to
low head duty by changing the number of
stages.
H
ft
H
m
1500
300
Applications
High pressure seawater feed
in RO desalination plants,
Distribution for water works, and others
0
50
The diffuser guides flow from impeller discharge
to next impeller suction eye. The axial force is
compensated by a hydraulic balancing device.
The integrated design accumulated by high
pressure and high speed pumps results in
excellent cost performance and high efficiency.
Q l/s
Q m3/h
400
200
300
800
2000 USgpm 3000
1000
3
1
10
10
100
10
850
100
Q l/s
Q m3/h
1000
3000
up to 2,900 m3/h / 12,760 USgpm
up to 490 m / 1,560 ft
up to 200°C / 390°F
up to 3.9 MPa / 39 bar / 565 psi
40 to 400 mm
Capacity
Total Head
Temperature
Pressure
Size
H
ft
H
m
1500
300
50
100
200
Q l/s
Q m3/h
400
200
300
800
1000
up to 800 m3/h / 3,520 USgpm
up to 800 m / 2,600 ft
125 to 200 mm
Capacity
Total Head
Size
30
USgpm
300
HLV, HLAV
8000
3000
500
1500
300
21
10
2500
Horizontal multistage ring section pump
Applications
Boiler feed in power plants,
High pressure feed water in various industries,
Condensate in seawater desalination,
Distribution / Boosting for water works,
Irrigation for agriculture, and others
100
30
Specialized Pumps
4000
800
0
Axial thrust of MMK is balanced by the impeller
balance holes, and by way of MML the balance
disc, so that MMK and MML can operate with high
reliability at high speed.
H
m
Applications
Hot water / Condensate / High and low pressure
drain in thermal power plants
1000
up to 800 m3/h / 3,520 USgpm
up to 800 m / 2,600 ft
150 to 300 mm
Capacity
Total Head
Size
Applications
High pressure seawater feed
in RO desalination plants
MMK, MML
100
200
MHA
Horizontal end-suction multistage ring
section pump
The high pressure vertical canister pump offers
significant advantage in those cases where
limited suction head is available. Applicable
especially for condensers in power plants,
desalination plants and other pipeline pumping
applications.
Bowl casing type
Multi-Stage / Specialized
Multi-Stage
Axially split multistage pump
500
1000
Capacity
Total Head
Size
MHH
300
Q l/s
Q m3/h
500
USgpm
100
H
m
MSH
400
Applications
High pressure seawater feed
in RO desalination plants,
Distribution for water works,
Water pumping for agriculture, and others
30
1000
1000
MML
H
m
Glandless(sealless) pump motor unit
(Boiler circulation pump)
H
ft
MMK
Pump and motor are integrated in a pressuretight casing. The glandless design (no shaft seal)
makes this pump best suited for pumping of high
temperature and high pressure liquids without
any leakage. Volute, annular or spherical casing
designs optionally available.
500
150
100
MMK
100
0
2
10
20
3
Q m /h
Capacity
Total Head
Temperature
Size
100
Q l/s
200
1000
600
2000
MMK
up to 1,800 m3/h / 7,930 USgpm
up to 150 m / 490 ft
up to 230°C / 440°F
40 to 350 mm
MML
MML
up to 1,800 m3/h / 7,930 USgpm
up to 500 m / 1,640 ft
up to 230°C / 440°F
40 to 350 mm
Applications
Boiler circulation in super / sub critical power
plants
100
USgpm 1000
10000
30000
200
500
H
ft
100
H
m
200
50
100
20
1
10
10
100
Q l/s
Q m3/h 1000
100
Capacity
Total Head
Temperature
Pressure
Motor Rating
Voltage
Size
1000
6000
up to 6,000 m3/h / 26,420 USgpm
up to 180 m / 590 ft
up to 420°C / 790°F
up to 32 MPa / 320 bar / 4,640 psi
up to 1,000 kW
400V to 11 kV
40 to 400 mm
22
13. Mixed-Flow Pumps
SPSX
Mixed-flow volute pump
Mainly used for water pumping and drainage for
agriculture. Simple back pull-out structure
allowing ease of overhaul.
Applications
Water pumping / Drainage for agriculture,
Drainage for civil engineering work,
Flood control, and others
2000
20
USgpm
15
50
H
m
40
H
ft
10
30
20
5
100
200
400
Horizontal mixed-flow pump
10
Offering the highest efficiency in low head and
large capacity range. The axially split design
offering ease of maintenance of rotating
equipment without removing the lower casing.
H
m
Applications
Water pumping / Drainage for agriculture,
Sewage transfer,
Rain water drainage,
Storm surge drainage, and others
USgpm
3000
Mixed-Flow
Vertical mixed-flow pump
200000
50
360 to 1,380 m3/h /
1,580 to 6,070 USgpm
5 to 17 m / 16 to 54 ft
250 to 350 mm
H
ft
20
10
2
150
1500
600
Q l/s
Q m3/h
5000
Capacity
600 to 36,000 m3/h /
2,600 to 158,400 USgpm
2 to 9 m / 6 to 29 ft
up to 40°C / 100°F
400 to 2,000 mm
USgpm
3000
15000
50000
30000
300000
100
300
200
50
IS
H
m
50
10
H
ft
15
2
150
1500
Q l/s
Q m3/h
5000
600
Capacity
Total Head
Temperature
Size
SPSY
5000
60
Mixed-flow volute pump
50000
600 to 80,000 m3/h /
2,600 to 360,000 USgpm
up to 100 m / 330 ft
-10 to 80°C / -50 to 175°F
300 to 2,800 mm
Suitable for fresh water and waste water
pumping. Both open and closed type impeller
available.
20000
50000
160
80
20
40
Applications
Distribution / Drainage for water works / sewage,
Water pumping for agriculture,
Cooling water in power plants,
Seawater recirculation in seawater desalination
plants, and others
23
Diffuser type, axial flow propeller suspended
within wet pit. Offering various hydraulic models
suitable for large capacity with low pump head of
water. Axially split design offering easy
maintenance without removing the lower casing.
10
6
300
500
1500
1000
3000
Capacity
Total Head
Size
2000
Q m3/h
Q l/s
10000
5000
20
10000
30000
up to 20,000 m3/h / 88,000 USgpm
up to 50 m / 160 ft
350 to 1,200 mm
1000000
H
m
10
2
H
ft
5
1
110
400
500
20000 66000
Q l/s 5000
Q m3/h 20000 50000
200000
2000
660 to 36,000 m3/h /
2,900 to 158,400 USgpm
1.5 to 5 m / 5 to 16 ft
400 to 2,000 mm
Capacity
2000
20000
6
USgpm
200000
Vertical axial-flow propeller pump
H
ft
H
m
200000
15
Total Head
Size
100000
USgpm
4
ISV
40
USgpm
20000
Axial-flow propeller pump
Applications
Water pumping / Drainage for agriculture,
Sewage transfer,
Rain water drainage,
Storm surge drainage, and others
15000
2000
6
Axial-Flow
Applications
Rain water drainage / Water intake for water
works / sewage, Circulation / Cooling water /
Condensate in power plants, Seawater intake /
Brine recirculation in seawater desalination
plants, Water intake / Cooling water in petrochemical industries, Cooling water / Water
intake / Dock drainage for general industries
400
1400
Axial-Flow Pumps
100
Diffuser type, single or multistage design,
mixed-flow impeller suspended within wet pit.
Offering various hydraulic models, materials,
and installation arrangement (above or below
floor discharge) to suit the plant specific design.
300
1000
30
Total Head
Temperature
Size
SPV
30000
Q l/s
Q m3/h
700
Total Head
Size
20
6000
60
Capacity
SP
4000
1000000
15
4
Diffuser type, axial flow propeller suspended
within wet pit. Especially used for large capacity
with low head of water. The various hydraulic
models applied to the change of the capacity and
head.
Applications
Water pumping / Drainage for agriculture,
River water drainage,
Cooling water in power plants
H
m
10
2
H
ft
5
1
110
400
500
2000
Capacity
Total Head
Size
20000 66000
Q l/s 5000
Q m3/h 20000 50000
200000
600 to 186,000 m3/h /
2,640 to 818,400 USgpm
1.5 to 5 m / 5 to 16 ft
400 to 4,600 mm
24
14. Submersible Pumps
S/M
Dry-type submersible motor pump
Small light-weight and easy to handle. Best suited
for discharging waste water at construction sites
and draining water in buildings and factories. The
motor is equipped with an auto-cut device,
submersion detection device and protection
device. The impeller is made of wear resistant
materials.
500
10000
USgpm
100000
30
Horizontal tubular pump-units combining an
axial-flow or mixed-flow pump and a dry-type electric
motor in a single tube. Little noise and compact
owing to the small water flow loss and the combined
motor. Either connected directly to an electric motor
or used with a reduction gear for slower rotation.
6
SMS
H
m
H
ft
10
Dry-type submersible pump
Large capacity submersible propeller pumps with low
head capabilities. Offering high efficiency and superior
performance with compact design and easy operation.
Designed to meet the requirements for efficient handling
of large capacity of water. In particular, for installation,
maintenance and inspection in pits, “Auto In-Pipe Column
Installation type” adopted because of the high reliability
and rapid discharge connections.
4
1
100
100
10
0
0
4000
Capacity
Total Head
Size
10000
Q l/s
Q m3/h
Applications
Waste water / material drainage for sewage,
Waste water / material drainage for construction
facilities,
Rain water drainage, and others
60000
40000
200000
up to 210,000 m3/h / 924,000 USgpm
2 to 8 m / 6.5 to 26 ft
400 to 5,000 mm
Applications
Water intake / Distribution / Drainage for water works,
Water pumping / Drainage for agriculture,
Industrial water / cooling water / drainage,
Drainage for civil engineering work, and others
150
300
3000
15
5000
USgpm
10000
40
Submersible motor pump for deep well
10
SMSV
20
5
Vertical or horizontal submersible motor pumps
with radial or mixed flow impellers, multi-stage.
Water sealed three-phase induction motor is
highly reliable electrically and mechanically as
submersible motor, and enables less trouble and
safe operation.
H
ft
H
m
10
SMIV
2
5
1
200
800
500
Q l/s
1000
Q m3/h
1000
2000
1400
5000
SMIV
Capacity
Total Head
Size
1000
80
SMIV
up to 4,500 m3/h / 19,800 USgpm
up to 6 m / 19 ft
400 to 700 mm
USgpm
10000
SMSV
SMSV
up to 4,200 m3/h / 18,500 USgpm
up to 14 m / 46 ft
400 to 700 mm
200
50
Submersible motor pump for shallow well
50
10
30
Water sealed three-phase induction motor is
adopted for submersible motor. Suction entry of
F/VC and F/UW is located at the bottom and that
of F/VD and F/SP is between pump and motor.
H
ft
H
m
10
2
1
0.8
100
50
200
Capacity
Total Head
Size
Q l/s
Q m3/h
500
2000 3000
2000
10000
3
up to 9,000 m /h / 39,600 USgpm
up to 70 m / 230 ft
150 to 1,000 mm
1200
USgpm 2000
5000
Applications
Water intake / Distribution / Water supply
for water works,
Water feed / Distribution for general industries,
Water pumping for agriculture
10000
20000
40000
10
30
T/B
H
m
H
ft
2
5
3
100
Q l/s
10
400
1000 Q m3/h 2000
50
500
1000
3000
4000
T/C (Cutter)
up to 72 m3/h /
310 USgpm
up to 22 m / 72 ft
50 to 100 mm
T/B (Bladeless)
up to 4,800 m3/h /
21,100 USgpm
up to 40m /130ft
50 to 800m
100
10000
USgpm 500
1000
T/B
T/N (Non-clog)
up to 78 m3/h /
340 USgpm
up to 26 m / 85 ft
32 to 100 mm
2000
700
200
350
100
H
m
H
ft
100
30
Applications
Water intake / Distribution / Water supply
for water works,
Water feed / Distribution for general industries,
Water pumping for agriculture
F/VC, F/VD, F/UW,
F/SP
40000
900
150
F/TB
20000
10
330
200
Q l/s
Q m /h 600
3
up to 1,000 m3/h / 4,400 USgpm
up to 230 m
40 to 350 mm
Capacity
Total Head
Size
Total Head
Size
SMV
25
0
100
Capacity
100
SMV is vertical tubular casing pump with
submersible motor. Water-filled or oil-filled type
motor is provided.
SMRV uses an oil-filled type submersible motor
whose suction entry is located between motor and
pump.
50
1
5
10
10
Capacity
Total Head
Size
10
100
Q l/s
Q m3/h
20
100
50
130
200
400
3 to 400 m3/h / 13 to 1,760 USgpm
up to 200 m / 655 ft
25 to 200 mm
100
USgpm
1000
4000
300
Submersible
Submersible
Large-size submersible motor pump
1000
400
Applications
Water pumping for agriculture, River drainage, Rain water
drainage, Water intake / Drainage for sewage, and others
SMV, SMRV
H
ft
50
30
Wide ranges of impellers suited for all types of
sewage and effluent, especially untreated sewage
containing fibers, solid admixtures, sewage sludge,
circulating sludge. Removable device for ease of
maintenance and inspection also available.
SMI
SMI
Applications
Water intake / Distribution / Drainage for water
works, Water pumping / Drainage for agriculture,
Industrial water / cooling water / drainage, Drainage
for civil engineering work, and others
SMIV(Axial-flow),
SMSV(Mixed-flow)
300
H
m
50
60
20
3
Tubular pump
5000
800
100
T/B, T/C, T/N
700000
4000
600
Submersible motor pump
2000
10
USgpm
2000
200
Applications
Waste water / Sludge drainage
for civil engineering works,
Drainage in factories, and others
SMI (Axial-Flow),
SMS (Mixed-Flow)
1000
250
200
50
100
H
m
H
ft
50
10
20
4
0.6
2
20
Q l/s
10
Capacity
Total Head
Size
50
200 300
Q m3/h
F/VC
up to 66 m3/h /
290 USgpm
up to 90 m / 295 ft
40 to 100 mm
500
F/VC
1000
F/VD
up to 300 m3/h /
1,320 USgpm
up to 70 m / 229 ft
65 to 250 mm
F/UW
up to 420 m3/h /
1,850 USgpm
up to 46 m / 150 ft
125 to 250 mm
F/SP
up to 660 m3/h /
2,900 USgpm
up to 46 m / 150 ft
125 to 300 mm
26
15. Miscellaneous Pumps
TE/O,
TE/CO (Stainless steel)
Self priming pump
No need for priming. Offering outstanding self
priming performance and durability.
Direct-connected motor is standard.
Applications
For industrial facilities, construction facilities,
agriculture, waste water treatment, and others
10
USgpm 200
50
50
5
100
USgpm
20
100
300
300
30
100
H
m
H
ft
40
10
15
4
0.5
2
2
10
3
Q m /h
10
H
ft
20
5
5
1
1
1
3
3
10
5
Q l/s
Q m3/h
10
25
20
90
up to 84 m3/h / 370 USgpm
up to 60 m / 20 ft
up to 100°C / 210°F
25 to 100 mm
Capacity
Total Head
Temperature
Size
N/WR
Wesco pump
USgpm
20
100
200
500
300
Applications
Water feed / pumping for general industries,
Chemical liquid transfer,
Various fuel oil transfer,
High pressure boiler feed,
High pressure washing, and others
NV
Vacuum pump
Suitable for pumping slurry and pulp stocks up
to 5% consistency. The Impeller is Mixed flow
type allowing the pump to be used for a wide
range of applications.
Applications
Pulp liquid transfer for paper / pulp industries,
Solid transfer / drainage for general industries,
Fruit or cereal and water mixture transfer for
food industries, and others
SNK
Screw Pump
H
m
Specially-shaped impeller revolves at high speed
in casing, makes the flow and absorbs up.
Extremely small impeller clearance due to the use
of a special method of fixing and special materials
to assure high stability. Best suited for
applications with small capacity and high head.
200
500
500
2000
800
H
ft
200
500
100
Suitable for pumping liquids containing small
stones, other suspended solids or rags, pieces of
wood or ropes, digested or activated sludge etc.
The simple, rugged construction and the open
screw trough facilitate maintenance and
inspection.
100
0
0
1
2
2
5
Q l/s
Q m3/h
Capacity
Total Head
Temperature
Size
10
8
16
50
32
100
up to 72 m3/h / 310 USgpm
up to 300 m / 980 ft
up to 90°C / 190°F
15 to 80 mm
Air Capacity
up to 72 m3/min
Negative Pressure up to 88 kPa
Size
20 to 100 mm
Applications
Water pumping for treatment plants,
Water pumping / Drainage for agriculture,
Return sludge for sewage treatment plants,
Waste water transfer, and others
S/T
TE/CO
up to 180 m3/h / 790 USgpm
up to 50 m / 160 ft
0 to 40°C / 30 to100°F
25 to 125 mm
5000
80
250
H
ft
100
30
H
m
Applications
Water and hot water circulation in building facilities,
Processes for various industries,
General water feed,
Boosting for water works, and others
50
200
up to 780m³/h / 3,434USgpm
TE/O
up to 70mm229ft
300 / 3/h / 1,320 USgpm
up 40 m / 130 ft
50 to 250mm
0 to 40°C / 30 to100°F
25 to 200 mm
USgpm
100
50
Q l/s
Pulp pump
Line pump
Pump and 2-pole motor close coupled with
common shaft. Line construction of suction entry
and discharge fits in any position into a pipeline.
O/PS
2000
150
Capacity
Capacity
Total Head
Total
Size Head
Temperature
Size
K/LP,
K/SLP2 (Stainless steel)
1000
30
100
H
m
50
10
30
4
0
Q l/s 10
20
50
50
400
200
1000
up to 780 m3/h / 3,430 USgpm
up to 70 m / 230 ft
50 to 250 mm
Capacity
Total Head
Size
350 1000
Q m3/h
USgpm
5000 20000
50000
30
9
H
m
H
ft
6
15
3
2
20
200
75
500
1000
Q l/s
7
5100
2000
Q m3/h
5000
10000
up to 18,000 m3/h / 79,250 USgpm
up to 10 m / 32 ft
400 to 3,500 mm
Capacity
Total Head
Size
10
100
100
USgpm
1000
4000
300
Vertical Volute Pump
200
50
The rotating, water-sealed pump sucks and
exhausts gas using the centrifugal force of the
liquid. Continuous gas exhaustion is made
without vibration and in complete safety even
when water enters in the pump interior during
operation.
27
Applications
Boosting / Water feed / Water pumping for
general industries, and others
100
H
m
H
ft
50
10
20
4
0.6
2
10
Q l/s
Q m3/h
Capacity
Total Head
Temperature
Size
20
50
200 300
100
500
1000
3
up to 600 m /h / 2,640 USgpm
up to 75 m / 240 ft
0 to 80°C / 32 to 176°F
40 to 150 mm
28
Miscellaneous
Miscellaneous
Applications
Pump water priming,
Gas exhaustion / Vacuum generation /
Pressure-feeding for chemical industries
Easy-installation close-coupled construction. Size
40 to 100mm back pull-out structure facilitates
ease of maintenance.
16. Torishima’s
Torishima’s
Mechanical Seals
Service Solutions
Mechanical seals - the shaft seals used in rotating machinery such as pumps, hydraulic turbines, agitators and
centrifuges - play an important role in maintaining the safety and economic efficiency of machinery. As a comprehensive
manufacturer of pumps, Torishima has never lost sight of the importance of mechanical seals. We are the fastest in the
country at moving products from the research and development phase to manufacturing and commercialization.
As a premier engineered equipment supplier, Torishima is
committed to provide the highest quality aftermarket service.
Our innovative solutions can enhance performance and
increase the life span of pumps, other equipment and plants.
This allows operators to maximize efficiency, reduce
maintenance costs and conserve energy.
Today, we provide a wide range of mechanical seals for applications requiring high levels of safety and quality, such as
mechanical seals for sealing high-temperature and high-pressure fluids in power plant pumps (including boiler feed
pumps and boiler circulating pumps). We also manufacture mechanical seals for pumps used in sewage plants,
chemical plants, and desalination plants handling slurry-rich liquid, special highly corrosive liquids, and seawater.
Moreover, we have utilized our years of experience in pump manufacturing to provide eco-friendly non-flushing seals,
easy-maintenance cartridge seals, and a variety of other optimal mechanical seals for a diverse range of applications.
Mechanical Seal Applications
Rubber
bellows seals
● ● ● ●
(Double seal)
●
● ●
●
● ●
●
HB2000 Series
● ● ● ● ● ● ●
●
● ●
●
●
● ● ● ●
● ●
● ● ● ● ● ● ●
MB2000 Series
● ●
● ● ● ●
● ●
● ● ● ● ● ● ●
(Balanced type)
MT2700
● ●
MB2500
● ●
●
MB2704CN
● ● ● ● ● ● ● ● ● ● ● ●
MB2704CZ
● ●
MB8500CZ
● ●
(Inside rotating type)
(Inside rotating type,
with pumping ring)
(Stationary inside type)
(Stationary inside type,
with pumping ring)
●
●
● ●
● ● ● ● ● ●
MB2901
●
(Stationary balanced type,
non-flushing)
Split seals
● ●
MT9200
Special-purpose
seals
For hydraulic
turbines
For submersible
sand pumps
29
● ● ●
● ●
● ●
● ● ● ●
(Stationary balanced type,
dry running application)
(Balanced type)
●
Energy
Saving
●
●
●
● ●
Torishima has the ability to combine field service
engineering and product design technology.
This results in our engineers being able to provide
advice on improved design and the upgrade of in-site
pumping equipment and other rotating equipment.
upgrading to a more reliable and higher-efficiency pump.
●
Reduction of
energy consumption
and CO2 emissions
Impeller
Before
upgrading
●
● ● ● ● ● ●
What’s
REDU?
Operating cost and CO2 emissions are reduced by
● ● ● ●
(Stationary balanced type,
dry running application)
MT4100
●
●
● ● ● ● ● ● ● ● ● ● ● ● ●
MU2922
Stationary
seals
●
●
MB2400CN
(Outside rotating type)
●
● ● ● ● ● ● ● ● ● ● ●
●
Inspecting of pumping plants
*REDU is a registration of
trademark of TORISHIMA
To improve your plant's productivity, Torishima offers
longer reliable and high-efficiency pumps. In addition to
servicing our own units, we restore, repair, improve and
upgrade even for pumps of other manufacturers. Using
the most advanced technologies, we offer products that
provide you with the highest efficiency and highest
possible performance.
● ●
MB8500CN
(Balanced type)
Torishima offers targeted advice after performing a full
maintenance inspection of the entire pump installation,
performing necessary maintenance, and diagnosing
whether the facility is being operated under the optimal
conditions. When pumping equipment breaks down,
our experienced engineers determine the basic cause
through a full analysis and replace broken parts to
ensure rapid restoration. In addition, we provide
hands-on guidance and training to plant operators.
Solution Provider
●
(Balanced type)
Cartridge
seals
Sand pumps
● ● ● ● ● ● ●
(Unbalanced type)
(Unbalanced type)
Stationary
multi-spring
seals
Hydraulic turbines
● ● ● ● ● ● ●
(Balanced type)
Rotating
multi-spring
seals
Submersible pumps
● ●
HU2000 Series
MU2000 Series
Rotating
single-spring
seals
Electro-deposition paint pumps
Cooling water pumps
Process pumps
● ● ● ● ● ● ● ● ●
●
LD1000 Series
Torishima provides field engineering service wherever needed to supervise pump installation work and equipment
commissioning, ensuring the pumping equipment can meet customer expectations.
Maintenance, Overhaul, Operator Training
General Industry, etc.
Feed water pumps
Feed water pumps
Cooling water pumps
Chemicals &
Petrochemicals
Process pumps
Irrigation pumps
Agricultural drainage pumps
Agricultural pumps
Rivers, Agriculture
& Irrigation
River drainage pumps
Sewage treatment pumps
● ● ●
Stormwater drainage pumps
Water transmission & distribution pumps
Product water pumps
Seawater intake pumps
Brine blowdown pumps
Brine recirculation pumps
Back wash pumps
High-pressure pumps
Water filtration pumps
Condensate pumps
●
LU1000 Series
Water Works
& Sewerage
Seawater Desalination
Cooling water pumps
Boiler feed pumps
Model of
Mechanical Seal
Boiler circulating pumps
Power
Generation
Field and Application
Installation & Field Test
Impeller
After
upgrading
Upgrade
●
●
●
Existing pump
High-efficiency pump
Existing
pump
Highefficiency
pump
Casing
Casing
30