 Cornea is the most powerful refractive
element of the eye contributing 43D(70%) of
refractive power of eye.
 Since the shape of corneal surface
determines its refractive power , even a
minor modification of its surface can lead to
significant alteration of image formed on
retina.
 Prolate shape
 Anterior surface of cornea: Elliptical
 Horizontal dia: 11.5mm
 Vertical dia:10.6mm
 Posterior surface of cornea is circular with
average diameter of 11.5mm
 Thickness of cornea:
 0.52mm at centre
 0.8mm at periphery
 1mm at limbus
 Anterior radius of curvature:7.8mm
 Posterior radius of curvature:6.5mm
 CENTRAL ZONE: Approximately 4mm
diameter.
 Also called the apical zone
 PARACENTRAL ZONE: 4-8mm diameter.
Flatter than the central zone.
 Central + Paracentral zone= optical zone.
 PERIPHERAL ZONE: 8-11 mm. It is the zone
where the normal cornea flattens the most
and becomes ashperic.
 LIMBAL ZONE
 Corneal topography refers to study of the
shape of corneal surface
 Placido based
 Elevation based
 Interferometric
 Rasterstereography
 Schiempflug imaging
 Devised by Helmholtz,who originally used the
term ophthalmometer
 Calculations are based on the geometry of a
spherical reflecting surface
 Based on fact that anterior surface of cornea
acts as convex mirror and size of image
varies with curvature
 Helps to measure the radius of curvature of
anterior corneal surface from 4 reflected
points within central 3mm of cornea
 Helmholtz keratometer
 Bausch and lomb keratometer
 Javal schiotz keratometer
 I/O=v/u
 Since image is formed near F so
v=F=r/2
therefore r can be calculated as
2uI/O
Thus for known object size ,
measurement of image size will
help determine radius of
curvature.
In all keratometers u is constant
being focal distance of viewing
telescope
 To overcome the natural movements of
patients eye for accurate measurements, the
principle of image doubling is used.
 The readings are obtained by aligning the
images with one another
 Fixed object size
 Image size is
adjusted to
measure corneal
curvature
 Uses rotationg
glass plates to
obtain doubling of
images
 Also based on
principle of
constant object
size and variable
image size
 Based on principle
of variable object
and constant
image size.
 Doubling of image
is achieved by
wollaston prism
 Assumes cornea to be spherical
 Details of only central 3mm ignoring
peripheral corneal zones
 Loses accuracy when measuring very steep or
flat corneas
 Small corneal irregularities preclude the use
due to irregular astigmatism.
 consists of equally
spaced alternating
black and white
rings with a hole in
the centre to
observe patients
cornea.
 Utilizes corneal
reflections
(purkinje image )
of bright rings
 The steeper the
cornea the closer
reflected rings of
placido disc lie to
one another.
 DISADVANTAGE:
1. small degree of abnormality of corneal
shape are not easily identifiable.
2. Cannot be used in corneas with epithelial
defects and stromal ulcers etc because of
nonreflection of image by the cornea.
3. Anatomy of nose and orbit may limit field
size and restrict the corneal area that can
be examined
 A photographic film camera attached to a
keratoscope.
 Current photokeratoscopes(eg Nidek PKS
1000 or keracorneoscope) have 9-15 rings
which cover 55-75% of corneal surface.
 Closer the line steeper is the corneal surface
and the farther apart the lines flatter is the
corneal surface.
 Corneal cylinders of upto 3D can escape
detection by use of photokeratoscopy.
 Scanning slit
topography system.
 40 scanning slit
beams(20 from left
and 20 from right)
to scan the cornea
 Each of the 40 slit
images triangulates
one slice of ocular
surface.
 Total duration of
examination 1.5sec
Orbscan II :the placido disc added in orbscan 1
 Computer calculates
a hypothetical
sphere that matches
as close as possible
to to actual corneal
shape being
measured.
 Areas above sphere
shown in warm
colours and areas
below in blue colour
 The
Pentacam(Oculus
Inc) obtains
images of anterior
segment by
rotating
Schiempflug
camera which is a
digital charged
coupling device.
 Takes 50 meridonial sections through centre
of cornea which allows the system to realign
the central thinnest point of each section
before it reconstructs the corneal image.
Thus it eliminates any eye movement
occurring during the examination.
 Enables measurement of corneas with severe
irregularities such as keratoconus that may
not be amenable to placido imaging
 Enables calculation of pachymetry from
limbus to limbus
 It projects a calibrated grid onto fluroscein
stained tear film, takes photographs and uses
computer assisted algorithms to analyse the
pictures.
 The accuracy of the system is 0.3D for
diameter of 7mm.
 Uses the technique of lightwave interfernce.
 The interference fringes can cover the entire
anterior ocular surface not just cornea.
 Not in widespread clinical use.
 GREEN: near
normal power
 BLUE and its
shade: lower than
normal power
 RED and its shade:
higher than normal
power
 NORMALISED SCALE(VARIABLE SCALE):
 Different colour scales assigned to each map
 Instrument identifies actual minimal and
maximal keratometric diopteric value of
particular cornea
 Gives more detailed description
 ABSOLUTE SCALE(FIXED SCALE)
 Preset colour scale with same diopteric steps
 Minimum and maximum assigned to same
colours
 Larger increment in steps(0.5D) so may miss
subtle changes
 AXIAL MAP(SAGGITAL
MAP): original and most
commonly used map.
 Measures radius of
curvature for a
comparable sphere with
centre of rotation on
the axis of
videokeratoscope.
 Localised changes in
curvature and
peripheral changes are
poorly represented.
 LOCAL TANGENTIAL
CURVATURE
MAP(INSTANTANEOUS
MAP): it displays
tangential radius of
curvature or tangential
power which is
calculated by referring
to a neighbouring point
and not to axis of
videokeratoscope.
 Reflects local changes
and peripheral data
better than axial map
 REFRACTIVE MAP: displays refractive power
of cornea.
 ELEVATION MAP: displays corneal elevation
relative to a reference plane.
 DIFFERENCE MAP: displays changes in
certain values between 2 maps.
 RELATIVE MAP: displays some values by
comparing them to an arbitrary standard..
 Simulated keratometry(Sim K) :maximum
power of surface along any axis and the
power orthogonal to that axis(Sim K1 and Sim
K2)
 Surface Regularity Index(SRI): measure
regularity in central 4.5mm
 Zero for smooth surface, increases with
increasing astigmatism
 Surface Asymmetry Index(SAI):weighted
summation of differences in corneal power
between corresponding points 180 degrees
apart
 Asphericity: described quantitavely by the Q
value
 Q=0 for sphere
 Q<0 for prolate surface
 Q>0 for oblate surface
 Normal cornea has Q value of -0.26
 Anterior Float(Elevation Best Sphere):
 Anterior best fit sphere is calculated to best
match the anterior corneal surface.
 Elevation BFS map subtracts the calculated
BFS against the eye surface.
 Posterior Float(Elevation Best Sphere Map):
describes the back surface of the cornea in
the same manner.
 Keratometric(mean Power) Map:displays
refractive power of anterior surface of cornea
 Thickness (Pachymetry )map: displays
corneal thickness
 Warm colour indicates thinner cornea
 Keratometric
reading
 White to white
distance in mm
 Thinnest point of
cornea
 Angle kappa
readings
 Irregularity within
central 3mm and
5mm
 Normal cornea flattens progressively from
centre to periphery, nasal area flattening
more than temporal area
 Approximate distribution of keratographic
pattern varies as
 Round(23%)
 Oval(21%)
 Symmetric bow tie typical for regular
astigmatism(18%)
 Asymmetric bow tie(32%)
 Irregular(7%)
 Typically there is inferior area of steepening.
 Area of increased power surrounded by
concentric areas of decreased power
 An inferior superior power asymmetry
 A skewing of the steepest radial axis above
and below the horizontal meridian
 Keratoconus Predictability Index(KPI):
derived from 8 topographic indices.
KPI of >0.23 is indicative of keratoconus
KISA % index:
product of central K reading, I-S value,
astigmatism measured by Sim K value and
Skewed radial axis index(SRAX).
60%-or more is suspect
100% diagnostic
 RABINOWITZ DIAGNOSTIC CRITERIA :
 Consists of 3 topography derived indices
1.Keratometry value of 47.2 D or greater in the
central cornea
2. Inferior –Superior asymmetry value –
1.4D-1.9D is suggestive and >1.9D is
diagnostic
3. Posterior float elevation >40 micro m
suggestive of posterior ectasia
 Classical butterfly
appearance
 Against the rule
astigmatism in
early stage
 Thinning is
concentric to the
limbus generally
between 4 to 8 O
clock position
 Flattening over areas of peripheral
thinning(mostly superior and inferior cornea)
 High against the rule or oblique astigmatism
is a common feature
 Topographic
pattern with a
polygonal shape is
most common
pattern
 Depending on
number of
incisions made
square , hexagons
or octagons can be
seen
 Characterised by topograhic changes in
cornea following contact lens wear as a
result of mechanical pressure exerted by lens
 Usually 4 different form which occur alone or
with one another
i.Peripheral steepening
ii. Central flattening
iii. Furrow depression
iv. Central moulding
 To guide removal of tight sutures after
corneal surgery
 Guide contact lens fitting
 Evaluate effect of keratographic procedure

More Related Content

What's hot

What's hot (20)

Measurements of the optical constants of the eye
Measurements  of  the optical constants of the eyeMeasurements  of  the optical constants of the eye
Measurements of the optical constants of the eye
 
Optics of contact lens
Optics of contact lensOptics of contact lens
Optics of contact lens
 
Maddox rod
Maddox rodMaddox rod
Maddox rod
 
Jackson cross cylinder
Jackson cross cylinderJackson cross cylinder
Jackson cross cylinder
 
Amsler grid
Amsler gridAmsler grid
Amsler grid
 
pentacam
pentacampentacam
pentacam
 
keratometry
 keratometry keratometry
keratometry
 
Types of pediatric contact lens [autosaved]
Types of pediatric contact lens [autosaved]Types of pediatric contact lens [autosaved]
Types of pediatric contact lens [autosaved]
 
Keratoconus
KeratoconusKeratoconus
Keratoconus
 
Amblyopia
Amblyopia Amblyopia
Amblyopia
 
Measuring interpupillary distance
Measuring interpupillary distanceMeasuring interpupillary distance
Measuring interpupillary distance
 
subjective refraction
  subjective refraction  subjective refraction
subjective refraction
 
Retinoscopy and its principles
Retinoscopy and its principlesRetinoscopy and its principles
Retinoscopy and its principles
 
Pachymetry
PachymetryPachymetry
Pachymetry
 
Potential acuity meter
Potential acuity meterPotential acuity meter
Potential acuity meter
 
Bifocal lenses
Bifocal lensesBifocal lenses
Bifocal lenses
 
Scleral lenses
Scleral lensesScleral lenses
Scleral lenses
 
Ac/a ratio
Ac/a ratio Ac/a ratio
Ac/a ratio
 
AC/A
AC/AAC/A
AC/A
 
JCC -Jackson Cross Cylinder
JCC -Jackson Cross CylinderJCC -Jackson Cross Cylinder
JCC -Jackson Cross Cylinder
 

Viewers also liked (8)

Galilei corneal imaging
Galilei corneal imagingGalilei corneal imaging
Galilei corneal imaging
 
Orbscan &amp; topo
Orbscan &amp; topoOrbscan &amp; topo
Orbscan &amp; topo
 
Corneal topography wavefront analysis
Corneal topography wavefront analysisCorneal topography wavefront analysis
Corneal topography wavefront analysis
 
Direct Ophthalmoscopy
Direct OphthalmoscopyDirect Ophthalmoscopy
Direct Ophthalmoscopy
 
Direct opthalmoscopy~@Farhana.Islam
Direct opthalmoscopy~@Farhana.IslamDirect opthalmoscopy~@Farhana.Islam
Direct opthalmoscopy~@Farhana.Islam
 
Principles of Ophthalmoscopy
Principles of OphthalmoscopyPrinciples of Ophthalmoscopy
Principles of Ophthalmoscopy
 
Corneal topography
Corneal topographyCorneal topography
Corneal topography
 
Ophthalmoscopy
OphthalmoscopyOphthalmoscopy
Ophthalmoscopy
 

Similar to Corneal topography

Understanding corneal-topography
Understanding corneal-topographyUnderstanding corneal-topography
Understanding corneal-topography
manojraut125
 
keratometry-180905154718.pdf
keratometry-180905154718.pdfkeratometry-180905154718.pdf
keratometry-180905154718.pdf
anju468752
 

Similar to Corneal topography (20)

ELEVATION BASED CORNEAL TOPOGRAPHY.pptx
ELEVATION BASED  CORNEAL TOPOGRAPHY.pptxELEVATION BASED  CORNEAL TOPOGRAPHY.pptx
ELEVATION BASED CORNEAL TOPOGRAPHY.pptx
 
Topography presentation
Topography presentationTopography presentation
Topography presentation
 
Corneal topography
Corneal topographyCorneal topography
Corneal topography
 
Defending
DefendingDefending
Defending
 
Corneal topography and wavefront imaging
Corneal topography and wavefront imagingCorneal topography and wavefront imaging
Corneal topography and wavefront imaging
 
Corneal topography final
Corneal topography finalCorneal topography final
Corneal topography final
 
Corneal topography by suraj
Corneal topography by surajCorneal topography by suraj
Corneal topography by suraj
 
Corneal topography
Corneal topographyCorneal topography
Corneal topography
 
Corneal topography...ppt
Corneal topography...pptCorneal topography...ppt
Corneal topography...ppt
 
Understanding corneal-topography
Understanding corneal-topographyUnderstanding corneal-topography
Understanding corneal-topography
 
Keratometry
KeratometryKeratometry
Keratometry
 
Coneal topography instrumentation, techniques, procedures, limitations, advan...
Coneal topography instrumentation, techniques, procedures, limitations, advan...Coneal topography instrumentation, techniques, procedures, limitations, advan...
Coneal topography instrumentation, techniques, procedures, limitations, advan...
 
Corneal topography
Corneal topographyCorneal topography
Corneal topography
 
Keratometry
KeratometryKeratometry
Keratometry
 
keratometry-180905154718.pdf
keratometry-180905154718.pdfkeratometry-180905154718.pdf
keratometry-180905154718.pdf
 
IMAGING TECHNIQUES IN GLAUCOMA
IMAGING TECHNIQUES IN GLAUCOMAIMAGING TECHNIQUES IN GLAUCOMA
IMAGING TECHNIQUES IN GLAUCOMA
 
Pentacam and Corneal topography
Pentacam and Corneal topographyPentacam and Corneal topography
Pentacam and Corneal topography
 
Scheimpflug imaging in ophthalmology
Scheimpflug imaging in ophthalmologyScheimpflug imaging in ophthalmology
Scheimpflug imaging in ophthalmology
 
Keratometry & autorefraction
Keratometry & autorefractionKeratometry & autorefraction
Keratometry & autorefraction
 
A scan biometry
A scan biometryA scan biometry
A scan biometry
 

Recently uploaded

Salient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functionsSalient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functions
KarakKing
 
The basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptxThe basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptx
heathfieldcps1
 

Recently uploaded (20)

On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptxOn_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
 
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdf
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdfUnit 3 Emotional Intelligence and Spiritual Intelligence.pdf
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdf
 
ICT role in 21st century education and it's challenges.
ICT role in 21st century education and it's challenges.ICT role in 21st century education and it's challenges.
ICT role in 21st century education and it's challenges.
 
Towards a code of practice for AI in AT.pptx
Towards a code of practice for AI in AT.pptxTowards a code of practice for AI in AT.pptx
Towards a code of practice for AI in AT.pptx
 
Sensory_Experience_and_Emotional_Resonance_in_Gabriel_Okaras_The_Piano_and_Th...
Sensory_Experience_and_Emotional_Resonance_in_Gabriel_Okaras_The_Piano_and_Th...Sensory_Experience_and_Emotional_Resonance_in_Gabriel_Okaras_The_Piano_and_Th...
Sensory_Experience_and_Emotional_Resonance_in_Gabriel_Okaras_The_Piano_and_Th...
 
Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)
 
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
 
General Principles of Intellectual Property: Concepts of Intellectual Proper...
General Principles of Intellectual Property: Concepts of Intellectual  Proper...General Principles of Intellectual Property: Concepts of Intellectual  Proper...
General Principles of Intellectual Property: Concepts of Intellectual Proper...
 
Mehran University Newsletter Vol-X, Issue-I, 2024
Mehran University Newsletter Vol-X, Issue-I, 2024Mehran University Newsletter Vol-X, Issue-I, 2024
Mehran University Newsletter Vol-X, Issue-I, 2024
 
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
 
Salient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functionsSalient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functions
 
Wellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptxWellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptx
 
Google Gemini An AI Revolution in Education.pptx
Google Gemini An AI Revolution in Education.pptxGoogle Gemini An AI Revolution in Education.pptx
Google Gemini An AI Revolution in Education.pptx
 
ICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptx
 
The basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptxThe basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptx
 
Holdier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdfHoldier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdf
 
Single or Multiple melodic lines structure
Single or Multiple melodic lines structureSingle or Multiple melodic lines structure
Single or Multiple melodic lines structure
 
How to Create and Manage Wizard in Odoo 17
How to Create and Manage Wizard in Odoo 17How to Create and Manage Wizard in Odoo 17
How to Create and Manage Wizard in Odoo 17
 
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptx
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptxCOMMUNICATING NEGATIVE NEWS - APPROACHES .pptx
COMMUNICATING NEGATIVE NEWS - APPROACHES .pptx
 
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
 

Corneal topography

  • 1.
  • 2.  Cornea is the most powerful refractive element of the eye contributing 43D(70%) of refractive power of eye.  Since the shape of corneal surface determines its refractive power , even a minor modification of its surface can lead to significant alteration of image formed on retina.
  • 3.  Prolate shape  Anterior surface of cornea: Elliptical  Horizontal dia: 11.5mm  Vertical dia:10.6mm  Posterior surface of cornea is circular with average diameter of 11.5mm  Thickness of cornea:  0.52mm at centre  0.8mm at periphery  1mm at limbus  Anterior radius of curvature:7.8mm  Posterior radius of curvature:6.5mm
  • 4.  CENTRAL ZONE: Approximately 4mm diameter.  Also called the apical zone  PARACENTRAL ZONE: 4-8mm diameter. Flatter than the central zone.  Central + Paracentral zone= optical zone.  PERIPHERAL ZONE: 8-11 mm. It is the zone where the normal cornea flattens the most and becomes ashperic.  LIMBAL ZONE
  • 5.  Corneal topography refers to study of the shape of corneal surface
  • 6.  Placido based  Elevation based  Interferometric  Rasterstereography  Schiempflug imaging
  • 7.  Devised by Helmholtz,who originally used the term ophthalmometer  Calculations are based on the geometry of a spherical reflecting surface  Based on fact that anterior surface of cornea acts as convex mirror and size of image varies with curvature  Helps to measure the radius of curvature of anterior corneal surface from 4 reflected points within central 3mm of cornea
  • 8.  Helmholtz keratometer  Bausch and lomb keratometer  Javal schiotz keratometer
  • 9.  I/O=v/u  Since image is formed near F so v=F=r/2 therefore r can be calculated as 2uI/O Thus for known object size , measurement of image size will help determine radius of curvature. In all keratometers u is constant being focal distance of viewing telescope
  • 10.  To overcome the natural movements of patients eye for accurate measurements, the principle of image doubling is used.  The readings are obtained by aligning the images with one another
  • 11.  Fixed object size  Image size is adjusted to measure corneal curvature  Uses rotationg glass plates to obtain doubling of images
  • 12.  Also based on principle of constant object size and variable image size
  • 13.
  • 14.  Based on principle of variable object and constant image size.  Doubling of image is achieved by wollaston prism
  • 15.  Assumes cornea to be spherical  Details of only central 3mm ignoring peripheral corneal zones  Loses accuracy when measuring very steep or flat corneas  Small corneal irregularities preclude the use due to irregular astigmatism.
  • 16.
  • 17.  consists of equally spaced alternating black and white rings with a hole in the centre to observe patients cornea.  Utilizes corneal reflections (purkinje image ) of bright rings
  • 18.  The steeper the cornea the closer reflected rings of placido disc lie to one another.
  • 19.  DISADVANTAGE: 1. small degree of abnormality of corneal shape are not easily identifiable. 2. Cannot be used in corneas with epithelial defects and stromal ulcers etc because of nonreflection of image by the cornea. 3. Anatomy of nose and orbit may limit field size and restrict the corneal area that can be examined
  • 20.  A photographic film camera attached to a keratoscope.  Current photokeratoscopes(eg Nidek PKS 1000 or keracorneoscope) have 9-15 rings which cover 55-75% of corneal surface.  Closer the line steeper is the corneal surface and the farther apart the lines flatter is the corneal surface.  Corneal cylinders of upto 3D can escape detection by use of photokeratoscopy.
  • 21.  Scanning slit topography system.  40 scanning slit beams(20 from left and 20 from right) to scan the cornea  Each of the 40 slit images triangulates one slice of ocular surface.  Total duration of examination 1.5sec
  • 22. Orbscan II :the placido disc added in orbscan 1
  • 23.  Computer calculates a hypothetical sphere that matches as close as possible to to actual corneal shape being measured.  Areas above sphere shown in warm colours and areas below in blue colour
  • 24.  The Pentacam(Oculus Inc) obtains images of anterior segment by rotating Schiempflug camera which is a digital charged coupling device.
  • 25.  Takes 50 meridonial sections through centre of cornea which allows the system to realign the central thinnest point of each section before it reconstructs the corneal image. Thus it eliminates any eye movement occurring during the examination.  Enables measurement of corneas with severe irregularities such as keratoconus that may not be amenable to placido imaging  Enables calculation of pachymetry from limbus to limbus
  • 26.  It projects a calibrated grid onto fluroscein stained tear film, takes photographs and uses computer assisted algorithms to analyse the pictures.  The accuracy of the system is 0.3D for diameter of 7mm.
  • 27.  Uses the technique of lightwave interfernce.  The interference fringes can cover the entire anterior ocular surface not just cornea.  Not in widespread clinical use.
  • 28.
  • 29.  GREEN: near normal power  BLUE and its shade: lower than normal power  RED and its shade: higher than normal power
  • 30.  NORMALISED SCALE(VARIABLE SCALE):  Different colour scales assigned to each map  Instrument identifies actual minimal and maximal keratometric diopteric value of particular cornea  Gives more detailed description
  • 31.  ABSOLUTE SCALE(FIXED SCALE)  Preset colour scale with same diopteric steps  Minimum and maximum assigned to same colours  Larger increment in steps(0.5D) so may miss subtle changes
  • 32.  AXIAL MAP(SAGGITAL MAP): original and most commonly used map.  Measures radius of curvature for a comparable sphere with centre of rotation on the axis of videokeratoscope.  Localised changes in curvature and peripheral changes are poorly represented.
  • 33.  LOCAL TANGENTIAL CURVATURE MAP(INSTANTANEOUS MAP): it displays tangential radius of curvature or tangential power which is calculated by referring to a neighbouring point and not to axis of videokeratoscope.  Reflects local changes and peripheral data better than axial map
  • 34.  REFRACTIVE MAP: displays refractive power of cornea.  ELEVATION MAP: displays corneal elevation relative to a reference plane.  DIFFERENCE MAP: displays changes in certain values between 2 maps.  RELATIVE MAP: displays some values by comparing them to an arbitrary standard..
  • 35.  Simulated keratometry(Sim K) :maximum power of surface along any axis and the power orthogonal to that axis(Sim K1 and Sim K2)  Surface Regularity Index(SRI): measure regularity in central 4.5mm  Zero for smooth surface, increases with increasing astigmatism  Surface Asymmetry Index(SAI):weighted summation of differences in corneal power between corresponding points 180 degrees apart
  • 36.  Asphericity: described quantitavely by the Q value  Q=0 for sphere  Q<0 for prolate surface  Q>0 for oblate surface  Normal cornea has Q value of -0.26
  • 37.
  • 38.  Anterior Float(Elevation Best Sphere):  Anterior best fit sphere is calculated to best match the anterior corneal surface.  Elevation BFS map subtracts the calculated BFS against the eye surface.  Posterior Float(Elevation Best Sphere Map): describes the back surface of the cornea in the same manner.  Keratometric(mean Power) Map:displays refractive power of anterior surface of cornea  Thickness (Pachymetry )map: displays corneal thickness  Warm colour indicates thinner cornea
  • 39.  Keratometric reading  White to white distance in mm  Thinnest point of cornea  Angle kappa readings  Irregularity within central 3mm and 5mm
  • 40.  Normal cornea flattens progressively from centre to periphery, nasal area flattening more than temporal area  Approximate distribution of keratographic pattern varies as  Round(23%)  Oval(21%)  Symmetric bow tie typical for regular astigmatism(18%)  Asymmetric bow tie(32%)  Irregular(7%)
  • 41.
  • 42.  Typically there is inferior area of steepening.  Area of increased power surrounded by concentric areas of decreased power  An inferior superior power asymmetry  A skewing of the steepest radial axis above and below the horizontal meridian
  • 43.  Keratoconus Predictability Index(KPI): derived from 8 topographic indices. KPI of >0.23 is indicative of keratoconus KISA % index: product of central K reading, I-S value, astigmatism measured by Sim K value and Skewed radial axis index(SRAX). 60%-or more is suspect 100% diagnostic
  • 44.  RABINOWITZ DIAGNOSTIC CRITERIA :  Consists of 3 topography derived indices 1.Keratometry value of 47.2 D or greater in the central cornea 2. Inferior –Superior asymmetry value – 1.4D-1.9D is suggestive and >1.9D is diagnostic 3. Posterior float elevation >40 micro m suggestive of posterior ectasia
  • 45.
  • 46.  Classical butterfly appearance  Against the rule astigmatism in early stage  Thinning is concentric to the limbus generally between 4 to 8 O clock position
  • 47.  Flattening over areas of peripheral thinning(mostly superior and inferior cornea)  High against the rule or oblique astigmatism is a common feature
  • 48.  Topographic pattern with a polygonal shape is most common pattern  Depending on number of incisions made square , hexagons or octagons can be seen
  • 49.  Characterised by topograhic changes in cornea following contact lens wear as a result of mechanical pressure exerted by lens  Usually 4 different form which occur alone or with one another i.Peripheral steepening ii. Central flattening iii. Furrow depression iv. Central moulding
  • 50.