Sensors
Definition
A sensor; is a device that measures a physical quantity and converts it into a signal which can be
read by an observer or by an instrument. For example, a mercury-in-glass thermometer converts
the measured temperature into expansion and contraction of a liquid which can be read on a
calibrated glass tube. A thermocouple converts temperature to an output voltage which can be
read by a voltmeter. For accuracy, most sensors are calibrated against known standards.
Description
A sensor is a device which receives and responds to a signal. A sensor's sensitivity indicates how
much the sensor's output changes when the measured quantity changes. For instance, if the
mercury in a thermometer moves 1 cm when the temperature changes by 1 °C, the sensitivity is
1 cm/°C (it is basically the slope Dy/Dx assuming a linear characteristic). Sensors that measure
very small changes must have very high sensitivities. Sensors also have an impact on what they
measure; for instance, a room temperature thermometer inserted into a hot cup of liquid cools the
liquid while the liquid heats the thermometer. Sensors need to be designed to have a small effect
on what is measured; making the sensor smaller often improves this and may introduce other
advantages.
Characteristics of a good sensor
A good sensor obeys the following rules:
Is sensitive to the measured property
Is insensitive to any other property likely to be encountered in its application
Does not influence the measured property.
Linearity & Sensitivity
Ideal sensors are designed to be linear or linear to some simple mathematical function of the
measurement, typically logarithmic. The output signal of such a sensor is linearly proportional to
the value or simple function of the measured property.
The sensitivity is then defined as the ratio between output signal and measured property. For
example, if a sensor measures temperature and has a voltage output, the sensitivity is a constant
with the unit [V/K]; this sensor is linear because the ratio is constant at all points of
measurement.
Resolution
The resolution of a sensor is the smallest change it can detect in the quantity that it is measuring.
Often in a digital display, the least significant digit will fluctuate, indicating that changes of that
magnitude are only just resolved. The resolution is related to the precision with which the
measurement is made. For example, a scanning tunneling probe (a fine tip near a surface collects
an electron tunneling current) can resolve atoms and molecules.
Capacitive Displacement Sensors
An Overview
Capacitive sensors are noncontact devices capable of high-resolution measurement of the
position and/or change of position of any conductive target. The nanometer resolution of high-
performance sensors makes them indispensible in today's nanotechnology world. Capacitive
sensing can also be used to measure the position or other properties of nonconductive targets.
A Capacitive Sensor Measurement System
Capacitive sensor dimensional measurement requires three basic components:
a probe that uses changes in capacitance to sense changes in distance to the target,
driver electronics to convert these changes in capacitance into voltage changes,
a device to indicate and/or record the resulting voltage change.
Each of these components is a critical part in providing reliable, accurate measurements. The
probe geometry, sensing area size, and mechanical construction affect range, accuracy, and
stability. A probe requires a driver to provide the changing electric field that is used to sense the
capacitance. The performance of the driver electronics is a primary factor in determining the
resolution of the system; they must be carefully designed for a high-preformance application.
The voltage measuring device is the final link in the system. Oscilloscopes, voltmeters and data
acquisition systems must be properly selected for the application.
What is Capacitance?
Capacitance describes how the space between two conductors affects an electric field between
them. If two metal plates are placed with a gap between them and a voltage is applied to one of
the plates, an electric field will exist between the plates. This electric field is the result of the
difference between electric charges that are stored on the surfaces of the plates. Capacitance
refers to the ―capacity‖ of the two plates to hold this charge. A large capacitance has the capacity
to hold more charge than a small capacitance. The amount of existing charge determines how
much current must be used to change the voltage on the plate. It’s like trying to change the water
level by one inch in a barrel compared to a coffee cup. It takes a lot of water to move the level
one inch in the barrel, but in a coffee cup it takes very little water. The difference is their
capacity.
When using a capacitive sensor, the sensing surface of the probe is the electrified plate and what
you’re measuring (the target) is the other plate (we’ll talk about measuring non-conductive
targets later). The driver electronics continually change the voltage on the sensing surface. This
is called the excitation voltage. The amount of current required to change the voltage is measured
by the circuit and indicates the amount of capacitance between the probe and the target. Or,
conversely, a fixed amount of current is pumped into and out of the probe and the resulting
voltage change is measured.
How Capacitance Relates to Distance
Capacitance is determined by Area, Gap, and Dielectric (the material in the gap). Capacitance
increases when Area or Dielectric increase, and capacitance decreases when the Gap increases.
The capacitance between two plates is determined by three things:
Size of the plates: capacitance increases as the plate size increases
Gap Size: capacitance decreases as the gap increases
Material between the plates (the dielectric):
Dielectric material will cause the capacitance to increase or decrease depending on the
material
Area and Dielectric are held constant for ordinary capacitive sensing so only the Gap can change
the capacitance.
In ordinary capacitive sensing the size of the sensor, the size of the target, and the dielectric
material (air) remain constant. The only variable is the gap size. Based on this assumption, driver
electronics assume that all changes in capacitance are a result of a change in gap size. The
electronics are calibrated to output specific voltage changes for corresponding changes in
capacitance. These voltages are scaled to represent specific changes in gap size. The amount of
voltage change for a given amount of gap change is called the sensitivity. A common sensitivity
setting is 1.0V/100µm. That means that for every 100µm change in the gap, the output voltage
changes exactly 1.0V. With this calibration, a +2V change in the output means that the target has
moved 200µm closer to the probe.
Focusing the Electric Field
Probes use a guard to focus the electric field.
When a voltage is applied to a conductor, an electric field is emitted from every surface. For
accurate gauging, the electric field from a capacitive sensor needs to be contained within the
space between the probe’s sensing area and the target. If the electric field is allowed to spread to
other items or other areas on the target, then a change in the position of the other item will be
measured as a change in the position of the target. To prevent this from happening, a technique
called guarding is used. To create a guarded probe, the back and sides of the sensing area are
surrounded by another conductor that is kept at the same voltage as the sensing area itself. When
the excitation voltage is applied to the sensing area, a separate circuit applies the exact same
voltage to the guard. Because there is no difference in voltage between the sensing area and the
guard, there is no electric field between them to cause current flow. Any conductors beside or
behind the probe form an electric field with the guard instead of the sensing area. Only the
unguarded front of the sensing area is allowed to form an electric field to the target.
Effects of Target Size
The target size is a primary consideration when selecting a probe for a specific application.
When the sensor’s electric field is focused by guarding, it creates a field that is a projection of
the sensor size and shape. The minimum target diameter for standard calibration is 30% of the
diameter of the sensing area. The further the probe is from the target, the larger the minimum
target size
Range of Measurement
The range in which a capacitive sensor is useful is a function of the area of the sensing surface.
The greater the area, the larger the range. The driver electronics are designed for a certain
amount of capacitance at the sensor. Therefore, a smaller sensor must be considerably closer to
the target to achieve the desired amount of capacitance. The electronics are adjustable during
calibration, but there is a limit to the range of adjustment.
In general, the maximum gap at which a probe is useful is approximately 40% of the sensing
surface diameter. Standard calibrations usually keep the gap considerably less than that.
Multiple Channel Sensing
Frequently, a target is measured simultaneously by multiple probes. Because the system
measures a changing electric field, the excitation voltage for each probe must be synchronized or
the probes would interfere with each other. If they were not synchronized, one probe would be
trying to increase the electric field while another was trying to decrease it thereby giving a false
reading.
Driver electronics can be configured as masters or slaves. The master sets the synchronization
for the slaves in multiple channel systems.
Effects of Target Material
The electric field from the probe sensing area is seeking a conductive surface. For this reason,
capacitive sensors are not affected by the target material provided that it is a conductor. Because
the electric field from the sensor stops at the surface of the conductor, target thickness does not
affect the measurement.
Surface finish can affect the measurement. Capacitive sensors will measure the average position
of the target surface within the spot size of the sensor.
Measuring Non-Conductors
Nonconductors can be measured by passing the electric field through them to a stationary
conductive target behind.
Capacitive sensors are most often used to measure the change in position of a conductive target.
But capacitive sensors can be very effective in measuring presence, density, thickness, and
location of non-conductors as well. Non-conductive materials like plastic have a different
dielectric constant than air. The dielectric constant determines how a non-conductive material
affects capacitance between two conductors. By inserting a non-conductive material in the gap
between the probe and a stationary reference target, the capacitance will change in relationship to
the thickness, density, or location of the material.
Fringing can be used to measure nonconductive targets without a conductive background target.
Sometimes it’s not feasible to have a reference target in front of the probe. If the material has a
high dielectric constant and a large sensor is used, measurements can still be made by a
technique called fringing. If there is no conductive surface directly in front of the probe, the
sensor’s electric field will wrap back to the shell of the probe itself. This is called a fringe field.
If a non-conductive material is brought in proximity to the probe, its dielectric will change the
fringe field and this can be used to measure the non-conductive material.
Strategies for maximizing effectiveness and minimizing error
Maximizing Accuracy: Target Size
Small targets make measurement accuracy sensitive to small probe position errors.
Unless otherwise specified, factory calibrations are done with a flat conductive target that is
considerably larger than the sensor area. A system calibrated in this way will give accurate
results when measuring a flat target more than 30% larger than the sensing area. If the target area
is too small, the electric field will begin to wrap around the sides of the target. In this case, the
electric field extends farther than it did in calibration and will measure the target as farther away.
This means that the probe must be closer to the target for the same zero point. Because this
distance differs from the original calibration, error will be introduced. Error is also created
because the probe is no longer measuring a flat surface.
An additional problem of an undersized target is that the system becomes sensitive to X and Y
location of the probe relative to the target. Without changing the gap, the output will change
significantly if the probe is moved left or right because less of the electric field is going to the
center of the target and more is going around to the sides.
Maximizing Accuracy: Target Shape
Curved targets change the shape of the electric field, affecting accuracy.
Target shape is also a consideration. Since the capacitive sensors are calibrated to a flat target,
measuring a target with a curved surface will cause errors. Because the sensor will measure the
average distance to the target, the gap at zero volts will be different than when the system was
calibrated. Errors will also be introduced because of the different behavior of the electric field
with the curved surface. In cases where a non-flat target must be measured, the system can be
factory calibrated to the final target shape. Alternatively, when flat calibrations are used with
curved surfaces, multipliers can be provided to correct the measurement value.
Maximizing Accuracy: Surface Finish
Irregular surface finish can cause different measurements as the target moves parallel to the
probe face.
When the target surface is not perfectly smooth, the capacitive sensor will average over the area
covered by the spot size of the sensor. The measurement value can change as the sensor is moved
across the surface due to a change in the average location of the surface. The magnitude of this
error depends on the nature and symmetry of the surface irregularities.
Maximizing Accuracy: Parallelism
During calibration, the surface of the sensor is parallel to the target surface. If the probe or target
is tilted any significant amount, the shape of the spot where the field hits the target elongates and
changes the interaction of the field between the probe and target. Because of the different
behavior of the electric field, measurement errors will be introduced. Parallelism must be
considered when designing a fixture for the measurement.
Parameters used to determine the quality of the sensor
Sensitivity Error
Sensitivity Error - The slope of the actual measurements deviates from the ideal slope.
A sensor’s sensitivity is set during calibration. When sensitivity deviates from the ideal value
this is called sensitivity error, gain error, or scaling error. Since sensitivity is the slope of a line,
sensitivity error is usually presented as a percentage of slope; comparing the ideal slope with the
actual slope.
Offset Error
Offset Error - A constant value is added to all measurements.
Offset error occurs when a constant value is added to the output voltage of the system.
Capacitive sensor systems are usually ―zeroed‖ during setup, eliminating any offset deviations
from the original calibration. However, should the offset error change after the system is zeroed,
error will be introduced into the measurement. Temperature change is the primary factor in offset
error.
Linearity Error
Linearity Error - Measurement data is not on a straight line.
Sensitivity can vary slightly between any two points of data. This variation is called linearity
error. The linearity specification is the measurement of how far the output varies from a straight
line.
To calculate the linearity error, calibration data is compared to the straight line that would best fit
the points. This straight reference line is calculated from the calibration data using a technique
called least squares fitting. The amount of error at the point on the calibration curve that is
furthest away from this ideal line is the linearity error. Linearity error is usually expressed in
terms of percent of full scale. If the error at the worst point was 0.001mm and the full scale range
of the calibration was 1mm, the linearity error would be 0.1%.
Error Band
Gap
(mm)
Expected
Value
(VDC)
Actual
Value
(VDC)
Error
Band
(mm)
0.50 -10.000 -9.800 -0.010
0.75 -5.000 -4.900 -0.005
1.00 0.000 0.000 0.000
1.25 5.000 5.000 0.000
1.50 10.000 10.100 0.005
Error Band- the worst case deviation of the measured values from the expected values in a
calibration chart. In this case, the total error is -0.010mm.
Error band accounts for the combination of linearity and sensitivity errors. It is the measurement
of the worst case absolute error in the calibrated range. The total error is calculated by comparing
the output voltages at specific gaps to their expected value. The worst case error from this
comparison is listed as the capacitive sensor system’s total error.
High-Performance Capacitive Sensors
It is important to distinguish between "high-performance" sensors and inexpensive sensors.
Simple capacitive sensors, such as those used in inexpensive proximity switches or elevator
touch switches, are simple devices and in their most basic form could be designed in a high
school electronics class. Proximity type sensors are tremendously useful in automation
applications and many commercially available models are well made, but they are not suited to
precision metrology applications.
In contrast, capacitive sensors for use in precision displacement measurement and metrology
applications use complex electronic designs to execute complex mathematical algorithms. Unlike
inexpensive sensors, these high-performance sensors have outputs which are very linear, stable
with temperature, and able to resolve incredibly small changes in capacitance resulting in high
resolution measurements of less than one nanometer.
Advantages
Compared to other noncontact sensing technologies such as optical, laser, eddy-current, and
inductive, high-performance capacitive sensors have some distinct advantages.
Higher resolutions including sub nanometer resolutions
Not sensitive to material changes: Capacitive sensors respond equally to all conductors
Inexpensive compared to laser interferometers.
Capacitive sensors are not a good choice in these conditions:
Dirty or wet environment (eddy-current sensors are ideal).
Large gap between sensor and target is required (optical and laser are better).
Applications
Capacitive sensors are useful in any application requiring the measurement or monitoring of the
position of a conductive target.
Position Measurement/Sensing
Capacitive sensors are basically position measuring devices. The outputs
always indicate the size of the gap between the sensor's sensing surface
and the target. When the probe is stationary, any changes in the output
are directly interpreted as changes in position of the target. This is useful
in:
Automation requiring precise location
Semiconductor processing
Final assembly of precision equipment such as disk drives
Precision stage positioning
Dynamic Motion
Measuring the dynamics of a continuously moving target, such as a
rotating spindle or vibrating element, requires some form of noncontact
measurement. Capacitive sensors are ideal when the environment is clean
and the motions are small, requiring high-resolution.
Disk drive spindles
High-speed drill spindles
Ultrasonic welders
Vibration measurements
Thickness Measurement
Measuring material thickness in a noncontact fashion is a common
application for capacitive sensors. The most useful application is a two-
channel differential system in which a separate sensor is used for each
side of the piece being measured. Details on thickness measurements
with capacitive sensors are available in the Conductive Material
Thickness Measurement with Capacitive Sensors Application Note.
Capacitive sensor technology is used for thickness measurement in these
applications:
Silicon wafer thickness
Brake rotor thickness
Disk drive platter thickness
Nonconductive Thickness
Capacitive sensors are sensitive to nonconductive materials which are
placed between the probe's sensing area and a grounded back target. If
the gap between the sensor and the back target is stable, changes in the
sensor output are indicative of changes in thickness, density, or
composition of the material in the gap. This is used for measurements in
these applications:
Label positioning during application
Label counting
Glue detection
Glue thickness
Assembly testing
Assembly testing
Capacitive sensors have a much higher sensitivity to conductors than to
nonconductors. For this reason, they can be used to detect the
presence/absence of metallic subassemblies in completed assemblies. An
example is a connector assembly requiring an internal metallic snap ring
which is not visible in the final assembly. Online capacitive sensing can
detect the defective part and signal the system to remove it from the line.
Capacitive Sensing in HID
Capacitance sensors detect a change in capacitance when something or someone approaches or
touches the sensor. Capacitive sensing as a human interface device (HID) technology, for
example to replace the computer mouse, is becoming increasingly popular. Capacitive sensors
are used in devices such as laptop track-pads, MP3 players, computer monitors, cell phones and
others. More and more engineers choose capacitive sensors for their flexibility, unique human-
device interface and cost reduction over mechanical switches. Capacitive touch sensors have
become a predominant feature in a large number of mobile devices and MP3 players.
Capacitive sensors detect anything which is conductive or having dielectric properties. While
capacitive sensing applications can replace mechanical buttons with capacitive alternatives, other
technologies such as multi-touch and gesture-based touchscreens are also premised on capacitive
sensing.
Working Principle
A basic sensor includes a receiver and a transmitter, each of which consists of metal traces
formed on layers of a printed-circuit board (PCB). As shown in Figure 1, the AD714x has an on-
chip excitation source, which is connected to the transmitter trace of the sensor. Between the
receiver and the transmitter trace, an electric field is formed. Most of the field is concentrated
between the two layers of the sensor PCB. However, a fringe electric field extends from the
transmitter, out of the PCB, and terminates back at the receiver. The field strength at the receiver
is measured by the on-chip sigma-delta capacitance-to-digital converter. The electrical
environment changes when a human hand invades the fringe field, with a portion of the electric
field being shunted to ground instead of terminating at the receiver. The resultant decrease in
capacitance—on the order of femtofarads as compared to picofarads for the bulk of the electric
field—is detected by the converter.
In general, there are three parts to the capacitance-sensing solutions:
The driver IC, which provides the excitation, the capacitance-to-digital converter, and
compensation circuitry to ensure accurate results in all environments.
The sensor—a PCB with a pattern of traces, such as buttons, scroll bars, scroll wheels, or
some combination. The traces can be copper, carbon, or silver, while the PCB can be
FR4, flex, PET, or ITO.
Software on the host microcontroller to implement the serial interface and the device
setup, as well as the interrupt service routine. For high-resolution sensors such as scroll
bars and wheels, the host runs a software algorithm to achieve high resolution output. No
software is required for buttons.
AD714x Driver ICs
These capacitance-to-digital converters are designed specifically for capacitance sensing in
human-interface applications. The core of the devices is a 16-bit sigma-delta capacitance-to-
digital converter (CDC), which converts the capacitive input signals (routed by a switch matrix)
into digital values. The result of the conversion is stored in on-chip registers. The on-chip
excitation source is a 250-kHz square wave.
These devices interface with up to 14 external capacitance sensors, arranged as buttons, bars,
wheels, or a combination of sensor types. The external sensors consist of electrodes on a 2- or 4-
layer PCB that interfaces directly with the IC.
The devices can be set up to interface with any set of input sensors by programming the on-chip
registers. The registers can also be programmed to control features such as averaging and offset
adjustment for each of the external sensors. An on-chip sequencer controls how each of the
capacitance inputs is polled.
The AD714x also include on-chip digital logic and 528 words of RAM that are used for
environmental compensation. Humidity, temperature, and other environmental factors can affect
the operation of capacitance sensors; so, transparently to the user, the devices perform
continuous calibration to compensate for these effects, giving error-free results at all times.
One of the key features of the AD714x is sensitivity control, which imparts a different sensitivity
setting to each sensor, controlling how soft or hard the user’s touch must be to activate the
sensor. These independent settings for activation thresholds, which determine when a sensor is
active, are vital when considering the operation of different-size sensors. Take, for example, an
application that has a large, 10-mm-diameter button, and a small, 5-mm-diameter button. The
user expects both to activate with same touch pressure, but capacitance is related to sensor area,
so a smaller sensor needs a harder touch to activate it. The end user should not have to press one
button harder than another for the same effect, so having independent sensitivity settings for each
sensor solves this problem.
Different Shapes & Sizes in capacitance sensing
As noted earlier, the sensor traces can be any number of different shapes and sizes. Buttons,
wheels, scroll-bar, joypad, and touchpad shapes can be laid out as traces on the sensor PCB.
Figure below shows a selection of capacitance sensor layouts.
Button
8-Way
Switch
Slider
Wheel
Keypad
Touchpad
Selection of capacitance sensors
Many options for implementing the user interface are available to the designer, ranging from
simply replacing mechanical buttons with capacitive button sensors to eliminating buttons by
using a joypad with eight output positions, or a scroll wheel that gives 128 output positions.
The number of sensors that can be implemented using a single device depends on the type of
sensors required. The AD7142 has 14 capacitance input pins and 12 conversion channels. The
AD7143 has eight capacitance inputs and eight conversion channels. The table below shows the
number of input pins and conversion stages required for each sensor type. Any number of
sensors can be combined, up to the limit established by the number of available inputs and
channels.
Sensor Type
Number of CIN inputs
required
Number of conversion channels
required
Button 1 1 (0.5 for differential operation)
8-Way Switch 4—top, bottom, left, and right 3
Slider 8—1 per segment 8—1 per segment
Wheel 8—1 per segment 8—1 per segment
Keypad
Touchpad
1 per row, 1 per column 1 per row, 1 per column
Measurements are taken on all connected sensors sequentially—in a ―round-robin‖ fashion. All
sensors can be measured within 36 ms, though, allowing essentially simultaneous detection of
each sensor’s status—as it would take a very fast user to activate or deactivate a sensor within 40
ms.
Advantages
Capacitance sensors are more reliable than mechanical sensors—for a number of reasons. There
are no moving parts, so there is no wear and tear on the sensor, which is protected by covering
material, for example, the plastic cover of an MP3 player. Humans are never in direct contact
with the sensor, so it can be sealed away from dirt or spillages. This makes capacitance sensors
especially suitable for devices that need to be cleaned regularly—as the sensor will not be
damaged by harsh abrasive cleaning agents—and for hand-held devices, where the likelihood of
accidental spillages (e.g., coffee) is not negligible.
Conclusion
Capacitance sensors are an emerging technology for human-machine interfaces and are rapidly
becoming the preferred technology over a range of different products and devices. Capacitance
sensors enable innovative yet easy-to-use interfaces for a wide range of portable and consumer
products. Easy to design, they use standard PCB manufacturing techniques and are more reliable
than mechanical switches. They give the industrial designer freedom to focus on styling,
knowing that capacitance sensors can be relied upon to give a high-performance interface that
will fit the design.
References:
• http://www.analog.com/library/analogdialogue/
• http://www.lionprecision.com/tech-library/
• http://electronicdesign.com/Articles/
• http://www.sensorsmag.com/sensors
• http://en.wikipedia.org

More Related Content

What's hot

1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...
1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...
1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...AL- AMIN
 
Data acquisition system
Data acquisition systemData acquisition system
Data acquisition systemAkash Atul
 
Biomedical Instrumentation
Biomedical InstrumentationBiomedical Instrumentation
Biomedical Instrumentationlinsstalex
 
Permanent Magnet Moving Coil
Permanent Magnet Moving Coil Permanent Magnet Moving Coil
Permanent Magnet Moving Coil Chandan Singh
 
Temperature transduser ppt
Temperature transduser pptTemperature transduser ppt
Temperature transduser pptTayagarDiwakar
 
Temperature Transducers
Temperature TransducersTemperature Transducers
Temperature TransducersAsim Raza
 
Semiconductor sensors
Semiconductor sensorsSemiconductor sensors
Semiconductor sensorsSathvik Reddy
 
Digital storage ocilloscope
Digital storage ocilloscopeDigital storage ocilloscope
Digital storage ocilloscopekajal8899
 
digita storage oscilloscope (dso)
digita storage oscilloscope (dso)digita storage oscilloscope (dso)
digita storage oscilloscope (dso)Parind Patel
 
Temperature Sensors – Types
Temperature Sensors – TypesTemperature Sensors – Types
Temperature Sensors – Typeselprocus
 
MEASUREMENT OF BIO POTENTIAL USING TWO ELECTRODES AND RECORDING PROBLEMS
MEASUREMENT OF BIO POTENTIAL  USING TWO ELECTRODES AND RECORDING PROBLEMSMEASUREMENT OF BIO POTENTIAL  USING TWO ELECTRODES AND RECORDING PROBLEMS
MEASUREMENT OF BIO POTENTIAL USING TWO ELECTRODES AND RECORDING PROBLEMSBharathasreejaG
 
Signal conditioning unit
Signal conditioning unit Signal conditioning unit
Signal conditioning unit BharathasreejaG
 
ac dc bridges
ac dc bridgesac dc bridges
ac dc bridgesAJAL A J
 

What's hot (20)

Sweep Frequency Generator
Sweep Frequency GeneratorSweep Frequency Generator
Sweep Frequency Generator
 
1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...
1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...
1.Oscilloscope. 2.Block diagram of Oscilloscope. 3.Types of Oscilloscope. 4.A...
 
Data acquisition system
Data acquisition systemData acquisition system
Data acquisition system
 
Biomedical Instrumentation
Biomedical InstrumentationBiomedical Instrumentation
Biomedical Instrumentation
 
Permanent Magnet Moving Coil
Permanent Magnet Moving Coil Permanent Magnet Moving Coil
Permanent Magnet Moving Coil
 
Temperature transduser ppt
Temperature transduser pptTemperature transduser ppt
Temperature transduser ppt
 
Temperature Transducers
Temperature TransducersTemperature Transducers
Temperature Transducers
 
Semiconductor sensors
Semiconductor sensorsSemiconductor sensors
Semiconductor sensors
 
Digital storage ocilloscope
Digital storage ocilloscopeDigital storage ocilloscope
Digital storage ocilloscope
 
digita storage oscilloscope (dso)
digita storage oscilloscope (dso)digita storage oscilloscope (dso)
digita storage oscilloscope (dso)
 
Temperature Sensors – Types
Temperature Sensors – TypesTemperature Sensors – Types
Temperature Sensors – Types
 
Oscilloscope
OscilloscopeOscilloscope
Oscilloscope
 
Transducers
TransducersTransducers
Transducers
 
MEASUREMENT OF BIO POTENTIAL USING TWO ELECTRODES AND RECORDING PROBLEMS
MEASUREMENT OF BIO POTENTIAL  USING TWO ELECTRODES AND RECORDING PROBLEMSMEASUREMENT OF BIO POTENTIAL  USING TWO ELECTRODES AND RECORDING PROBLEMS
MEASUREMENT OF BIO POTENTIAL USING TWO ELECTRODES AND RECORDING PROBLEMS
 
Unit 1 cro ppt
Unit 1  cro pptUnit 1  cro ppt
Unit 1 cro ppt
 
Types of sensors
Types of sensorsTypes of sensors
Types of sensors
 
Amplifier
AmplifierAmplifier
Amplifier
 
Transducers
Transducers Transducers
Transducers
 
Signal conditioning unit
Signal conditioning unit Signal conditioning unit
Signal conditioning unit
 
ac dc bridges
ac dc bridgesac dc bridges
ac dc bridges
 

Viewers also liked

New Sensors for the Sensor Web
New Sensors for the Sensor WebNew Sensors for the Sensor Web
New Sensors for the Sensor WebTheodor Foerster
 
Advanced insrumentation lab manual
Advanced insrumentation lab manualAdvanced insrumentation lab manual
Advanced insrumentation lab manualGautam sai teza
 
Joshua Beckerman, MAE 315 Lab 2 Final Report
Joshua Beckerman, MAE 315 Lab 2 Final ReportJoshua Beckerman, MAE 315 Lab 2 Final Report
Joshua Beckerman, MAE 315 Lab 2 Final ReportJoshua Beckerman
 
process control instrumentation lab and labview report
process control  instrumentation lab and labview  reportprocess control  instrumentation lab and labview  report
process control instrumentation lab and labview reportHari Krishna
 
Sensors, Proximity sensors. Optical – Through-beam, Optical - Diffuse
Sensors, Proximity sensors. Optical – Through-beam, Optical - DiffuseSensors, Proximity sensors. Optical – Through-beam, Optical - Diffuse
Sensors, Proximity sensors. Optical – Through-beam, Optical - Diffuseأشرف أمجد الشريف
 
Sensors in Everyday Life
Sensors in Everyday LifeSensors in Everyday Life
Sensors in Everyday LifeKamlesh Kumar
 
Sensors for Biomedical Devices and systems
Sensors for Biomedical Devices and systemsSensors for Biomedical Devices and systems
Sensors for Biomedical Devices and systemsGunjan Patel
 
Smart sensors and their Application
Smart sensors and their ApplicationSmart sensors and their Application
Smart sensors and their ApplicationYash Kant
 
Android Development: The Basics
Android Development: The BasicsAndroid Development: The Basics
Android Development: The BasicsMike Desjardins
 
Flat slab design
Flat slab designFlat slab design
Flat slab designMoussa Rili
 
Home automation using android mobiles
Home automation using android mobilesHome automation using android mobiles
Home automation using android mobilesDurairaja
 
Level measuring instruments
Level measuring instrumentsLevel measuring instruments
Level measuring instrumentsAttiya Rehman
 

Viewers also liked (20)

4 bit Binary to Gray converter using XOR
4 bit Binary to Gray converter using XOR4 bit Binary to Gray converter using XOR
4 bit Binary to Gray converter using XOR
 
New Sensors for the Sensor Web
New Sensors for the Sensor WebNew Sensors for the Sensor Web
New Sensors for the Sensor Web
 
Smart Sensors,Modern Methods of Irrigation by saving water IDM10
Smart Sensors,Modern Methods of Irrigation by saving water IDM10Smart Sensors,Modern Methods of Irrigation by saving water IDM10
Smart Sensors,Modern Methods of Irrigation by saving water IDM10
 
Advanced insrumentation lab manual
Advanced insrumentation lab manualAdvanced insrumentation lab manual
Advanced insrumentation lab manual
 
Joshua Beckerman, MAE 315 Lab 2 Final Report
Joshua Beckerman, MAE 315 Lab 2 Final ReportJoshua Beckerman, MAE 315 Lab 2 Final Report
Joshua Beckerman, MAE 315 Lab 2 Final Report
 
A report on Proximity Sensor
A report on Proximity SensorA report on Proximity Sensor
A report on Proximity Sensor
 
process control instrumentation lab and labview report
process control  instrumentation lab and labview  reportprocess control  instrumentation lab and labview  report
process control instrumentation lab and labview report
 
Proximity Sensor
Proximity Sensor Proximity Sensor
Proximity Sensor
 
Proximity Sensors
Proximity SensorsProximity Sensors
Proximity Sensors
 
Sensors, Proximity sensors. Optical – Through-beam, Optical - Diffuse
Sensors, Proximity sensors. Optical – Through-beam, Optical - DiffuseSensors, Proximity sensors. Optical – Through-beam, Optical - Diffuse
Sensors, Proximity sensors. Optical – Through-beam, Optical - Diffuse
 
Sensors in Everyday Life
Sensors in Everyday LifeSensors in Everyday Life
Sensors in Everyday Life
 
Biomedical Optical Sensor
Biomedical Optical SensorBiomedical Optical Sensor
Biomedical Optical Sensor
 
Proximity sensors
Proximity sensorsProximity sensors
Proximity sensors
 
Proximity sensor
Proximity sensorProximity sensor
Proximity sensor
 
Sensors for Biomedical Devices and systems
Sensors for Biomedical Devices and systemsSensors for Biomedical Devices and systems
Sensors for Biomedical Devices and systems
 
Smart sensors and their Application
Smart sensors and their ApplicationSmart sensors and their Application
Smart sensors and their Application
 
Android Development: The Basics
Android Development: The BasicsAndroid Development: The Basics
Android Development: The Basics
 
Flat slab design
Flat slab designFlat slab design
Flat slab design
 
Home automation using android mobiles
Home automation using android mobilesHome automation using android mobiles
Home automation using android mobiles
 
Level measuring instruments
Level measuring instrumentsLevel measuring instruments
Level measuring instruments
 

Similar to Seminar Report - Capacitive Sensors

Transducers and it's types
Transducers and it's typesTransducers and it's types
Transducers and it's typesAbdul Sami
 
Sensors-Interfacing Techniques
Sensors-Interfacing TechniquesSensors-Interfacing Techniques
Sensors-Interfacing TechniquesDr.YNM
 
Electromagnetic and mechanical sensors
Electromagnetic and mechanical sensorsElectromagnetic and mechanical sensors
Electromagnetic and mechanical sensorsW3Edify
 
New electromagnetic force sensor measuring the density of liquids
New electromagnetic force sensor measuring the density of liquidsNew electromagnetic force sensor measuring the density of liquids
New electromagnetic force sensor measuring the density of liquidseSAT Publishing House
 
New electromagnetic dynamometer measuring the surface tension of liquids
New electromagnetic dynamometer measuring the surface tension of liquidsNew electromagnetic dynamometer measuring the surface tension of liquids
New electromagnetic dynamometer measuring the surface tension of liquidseSAT Publishing House
 
Sensors for Engineering Applications
Sensors for Engineering ApplicationsSensors for Engineering Applications
Sensors for Engineering Applicationsvenkatasuman1983
 
Sensors and data acquisation system
Sensors and data acquisation systemSensors and data acquisation system
Sensors and data acquisation systemMukut Kalita
 
Sensors and Transducers (1).pdf
Sensors and Transducers (1).pdfSensors and Transducers (1).pdf
Sensors and Transducers (1).pdfRAM PRAKASH PATEL
 
Capacitive sensing technology
Capacitive sensing technologyCapacitive sensing technology
Capacitive sensing technologykaroline Enoch
 
Sensor and transducers lect 1
Sensor and transducers lect 1Sensor and transducers lect 1
Sensor and transducers lect 1prashant tripathi
 

Similar to Seminar Report - Capacitive Sensors (20)

Transducers and it's types
Transducers and it's typesTransducers and it's types
Transducers and it's types
 
3288264.ppt
3288264.ppt3288264.ppt
3288264.ppt
 
Measurements Basics
Measurements BasicsMeasurements Basics
Measurements Basics
 
Proximity sensors
Proximity sensorsProximity sensors
Proximity sensors
 
Amit mahto final
Amit mahto finalAmit mahto final
Amit mahto final
 
Sensors-Interfacing Techniques
Sensors-Interfacing TechniquesSensors-Interfacing Techniques
Sensors-Interfacing Techniques
 
instrumentation-lecture-3
instrumentation-lecture-3instrumentation-lecture-3
instrumentation-lecture-3
 
PLC
PLCPLC
PLC
 
Electromagnetic and mechanical sensors
Electromagnetic and mechanical sensorsElectromagnetic and mechanical sensors
Electromagnetic and mechanical sensors
 
New electromagnetic force sensor measuring the density of liquids
New electromagnetic force sensor measuring the density of liquidsNew electromagnetic force sensor measuring the density of liquids
New electromagnetic force sensor measuring the density of liquids
 
New electromagnetic dynamometer measuring the surface tension of liquids
New electromagnetic dynamometer measuring the surface tension of liquidsNew electromagnetic dynamometer measuring the surface tension of liquids
New electromagnetic dynamometer measuring the surface tension of liquids
 
Sensors for Engineering Applications
Sensors for Engineering ApplicationsSensors for Engineering Applications
Sensors for Engineering Applications
 
SENSORS_UNIT-2.pdf
SENSORS_UNIT-2.pdfSENSORS_UNIT-2.pdf
SENSORS_UNIT-2.pdf
 
Report
ReportReport
Report
 
Sensors and data acquisation system
Sensors and data acquisation systemSensors and data acquisation system
Sensors and data acquisation system
 
Sensors and Transducers (1).pdf
Sensors and Transducers (1).pdfSensors and Transducers (1).pdf
Sensors and Transducers (1).pdf
 
Capacitive sensing technology
Capacitive sensing technologyCapacitive sensing technology
Capacitive sensing technology
 
Sensors
SensorsSensors
Sensors
 
Transducer main
Transducer mainTransducer main
Transducer main
 
Sensor and transducers lect 1
Sensor and transducers lect 1Sensor and transducers lect 1
Sensor and transducers lect 1
 

Recently uploaded

Traction part 2 - EOS Model JAX Bridges.
Traction part 2 - EOS Model JAX Bridges.Traction part 2 - EOS Model JAX Bridges.
Traction part 2 - EOS Model JAX Bridges.Anamaria Contreras
 
India Consumer 2024 Redacted Sample Report
India Consumer 2024 Redacted Sample ReportIndia Consumer 2024 Redacted Sample Report
India Consumer 2024 Redacted Sample ReportMintel Group
 
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deck
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deckPitch Deck Teardown: Geodesic.Life's $500k Pre-seed deck
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deckHajeJanKamps
 
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort ServiceCall US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Servicecallgirls2057
 
Kenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby AfricaKenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby Africaictsugar
 
Annual General Meeting Presentation Slides
Annual General Meeting Presentation SlidesAnnual General Meeting Presentation Slides
Annual General Meeting Presentation SlidesKeppelCorporation
 
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCRashishs7044
 
Innovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfInnovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfrichard876048
 
2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis UsageNeil Kimberley
 
APRIL2024_UKRAINE_xml_0000000000000 .pdf
APRIL2024_UKRAINE_xml_0000000000000 .pdfAPRIL2024_UKRAINE_xml_0000000000000 .pdf
APRIL2024_UKRAINE_xml_0000000000000 .pdfRbc Rbcua
 
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCRashishs7044
 
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptxContemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptxMarkAnthonyAurellano
 
MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?Olivia Kresic
 
Ms Motilal Padampat Sugar Mills vs. State of Uttar Pradesh & Ors. - A Milesto...
Ms Motilal Padampat Sugar Mills vs. State of Uttar Pradesh & Ors. - A Milesto...Ms Motilal Padampat Sugar Mills vs. State of Uttar Pradesh & Ors. - A Milesto...
Ms Motilal Padampat Sugar Mills vs. State of Uttar Pradesh & Ors. - A Milesto...ShrutiBose4
 
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / NcrCall Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncrdollysharma2066
 
PSCC - Capability Statement Presentation
PSCC - Capability Statement PresentationPSCC - Capability Statement Presentation
PSCC - Capability Statement PresentationAnamaria Contreras
 
Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Riya Pathan
 
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadIslamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadAyesha Khan
 
International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...ssuserf63bd7
 

Recently uploaded (20)

Traction part 2 - EOS Model JAX Bridges.
Traction part 2 - EOS Model JAX Bridges.Traction part 2 - EOS Model JAX Bridges.
Traction part 2 - EOS Model JAX Bridges.
 
Corporate Profile 47Billion Information Technology
Corporate Profile 47Billion Information TechnologyCorporate Profile 47Billion Information Technology
Corporate Profile 47Billion Information Technology
 
India Consumer 2024 Redacted Sample Report
India Consumer 2024 Redacted Sample ReportIndia Consumer 2024 Redacted Sample Report
India Consumer 2024 Redacted Sample Report
 
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deck
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deckPitch Deck Teardown: Geodesic.Life's $500k Pre-seed deck
Pitch Deck Teardown: Geodesic.Life's $500k Pre-seed deck
 
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort ServiceCall US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
 
Kenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby AfricaKenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby Africa
 
Annual General Meeting Presentation Slides
Annual General Meeting Presentation SlidesAnnual General Meeting Presentation Slides
Annual General Meeting Presentation Slides
 
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
 
Innovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfInnovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdf
 
2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage
 
APRIL2024_UKRAINE_xml_0000000000000 .pdf
APRIL2024_UKRAINE_xml_0000000000000 .pdfAPRIL2024_UKRAINE_xml_0000000000000 .pdf
APRIL2024_UKRAINE_xml_0000000000000 .pdf
 
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
 
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptxContemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
 
MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?
 
Ms Motilal Padampat Sugar Mills vs. State of Uttar Pradesh & Ors. - A Milesto...
Ms Motilal Padampat Sugar Mills vs. State of Uttar Pradesh & Ors. - A Milesto...Ms Motilal Padampat Sugar Mills vs. State of Uttar Pradesh & Ors. - A Milesto...
Ms Motilal Padampat Sugar Mills vs. State of Uttar Pradesh & Ors. - A Milesto...
 
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / NcrCall Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
 
PSCC - Capability Statement Presentation
PSCC - Capability Statement PresentationPSCC - Capability Statement Presentation
PSCC - Capability Statement Presentation
 
Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737
 
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadIslamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
 
International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...
 

Seminar Report - Capacitive Sensors

  • 1. Seminar Report On CAPACITIVE SENSORS Submitted by Student name: Tarun Nekkanti Roll No: 142 Section: C In partial fulfillment of the requirements for the award of the degree of BACHELOR OF ENGINEERING IN ELECTRONICS AND COMMUNICATION ENGINEERING DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING MANIPAL INSTITUTE OF TECHNOLOGY (A Constituent College of Manipal University) MANIPAL – 576104, KARNATAKA, INDIA 13 October 2010
  • 2. Sensors Definition A sensor; is a device that measures a physical quantity and converts it into a signal which can be read by an observer or by an instrument. For example, a mercury-in-glass thermometer converts the measured temperature into expansion and contraction of a liquid which can be read on a calibrated glass tube. A thermocouple converts temperature to an output voltage which can be read by a voltmeter. For accuracy, most sensors are calibrated against known standards. Description A sensor is a device which receives and responds to a signal. A sensor's sensitivity indicates how much the sensor's output changes when the measured quantity changes. For instance, if the mercury in a thermometer moves 1 cm when the temperature changes by 1 °C, the sensitivity is 1 cm/°C (it is basically the slope Dy/Dx assuming a linear characteristic). Sensors that measure very small changes must have very high sensitivities. Sensors also have an impact on what they measure; for instance, a room temperature thermometer inserted into a hot cup of liquid cools the liquid while the liquid heats the thermometer. Sensors need to be designed to have a small effect on what is measured; making the sensor smaller often improves this and may introduce other advantages. Characteristics of a good sensor A good sensor obeys the following rules: Is sensitive to the measured property Is insensitive to any other property likely to be encountered in its application Does not influence the measured property. Linearity & Sensitivity Ideal sensors are designed to be linear or linear to some simple mathematical function of the measurement, typically logarithmic. The output signal of such a sensor is linearly proportional to the value or simple function of the measured property. The sensitivity is then defined as the ratio between output signal and measured property. For example, if a sensor measures temperature and has a voltage output, the sensitivity is a constant
  • 3. with the unit [V/K]; this sensor is linear because the ratio is constant at all points of measurement. Resolution The resolution of a sensor is the smallest change it can detect in the quantity that it is measuring. Often in a digital display, the least significant digit will fluctuate, indicating that changes of that magnitude are only just resolved. The resolution is related to the precision with which the measurement is made. For example, a scanning tunneling probe (a fine tip near a surface collects an electron tunneling current) can resolve atoms and molecules. Capacitive Displacement Sensors An Overview Capacitive sensors are noncontact devices capable of high-resolution measurement of the position and/or change of position of any conductive target. The nanometer resolution of high- performance sensors makes them indispensible in today's nanotechnology world. Capacitive sensing can also be used to measure the position or other properties of nonconductive targets. A Capacitive Sensor Measurement System Capacitive sensor dimensional measurement requires three basic components: a probe that uses changes in capacitance to sense changes in distance to the target, driver electronics to convert these changes in capacitance into voltage changes, a device to indicate and/or record the resulting voltage change. Each of these components is a critical part in providing reliable, accurate measurements. The probe geometry, sensing area size, and mechanical construction affect range, accuracy, and stability. A probe requires a driver to provide the changing electric field that is used to sense the capacitance. The performance of the driver electronics is a primary factor in determining the resolution of the system; they must be carefully designed for a high-preformance application. The voltage measuring device is the final link in the system. Oscilloscopes, voltmeters and data acquisition systems must be properly selected for the application. What is Capacitance? Capacitance describes how the space between two conductors affects an electric field between them. If two metal plates are placed with a gap between them and a voltage is applied to one of
  • 4. the plates, an electric field will exist between the plates. This electric field is the result of the difference between electric charges that are stored on the surfaces of the plates. Capacitance refers to the ―capacity‖ of the two plates to hold this charge. A large capacitance has the capacity to hold more charge than a small capacitance. The amount of existing charge determines how much current must be used to change the voltage on the plate. It’s like trying to change the water level by one inch in a barrel compared to a coffee cup. It takes a lot of water to move the level one inch in the barrel, but in a coffee cup it takes very little water. The difference is their capacity. When using a capacitive sensor, the sensing surface of the probe is the electrified plate and what you’re measuring (the target) is the other plate (we’ll talk about measuring non-conductive targets later). The driver electronics continually change the voltage on the sensing surface. This is called the excitation voltage. The amount of current required to change the voltage is measured by the circuit and indicates the amount of capacitance between the probe and the target. Or, conversely, a fixed amount of current is pumped into and out of the probe and the resulting voltage change is measured. How Capacitance Relates to Distance Capacitance is determined by Area, Gap, and Dielectric (the material in the gap). Capacitance increases when Area or Dielectric increase, and capacitance decreases when the Gap increases. The capacitance between two plates is determined by three things: Size of the plates: capacitance increases as the plate size increases Gap Size: capacitance decreases as the gap increases Material between the plates (the dielectric): Dielectric material will cause the capacitance to increase or decrease depending on the material Area and Dielectric are held constant for ordinary capacitive sensing so only the Gap can change the capacitance.
  • 5. In ordinary capacitive sensing the size of the sensor, the size of the target, and the dielectric material (air) remain constant. The only variable is the gap size. Based on this assumption, driver electronics assume that all changes in capacitance are a result of a change in gap size. The electronics are calibrated to output specific voltage changes for corresponding changes in capacitance. These voltages are scaled to represent specific changes in gap size. The amount of voltage change for a given amount of gap change is called the sensitivity. A common sensitivity setting is 1.0V/100µm. That means that for every 100µm change in the gap, the output voltage changes exactly 1.0V. With this calibration, a +2V change in the output means that the target has moved 200µm closer to the probe. Focusing the Electric Field Probes use a guard to focus the electric field. When a voltage is applied to a conductor, an electric field is emitted from every surface. For accurate gauging, the electric field from a capacitive sensor needs to be contained within the space between the probe’s sensing area and the target. If the electric field is allowed to spread to other items or other areas on the target, then a change in the position of the other item will be measured as a change in the position of the target. To prevent this from happening, a technique called guarding is used. To create a guarded probe, the back and sides of the sensing area are surrounded by another conductor that is kept at the same voltage as the sensing area itself. When the excitation voltage is applied to the sensing area, a separate circuit applies the exact same voltage to the guard. Because there is no difference in voltage between the sensing area and the guard, there is no electric field between them to cause current flow. Any conductors beside or behind the probe form an electric field with the guard instead of the sensing area. Only the unguarded front of the sensing area is allowed to form an electric field to the target. Effects of Target Size The target size is a primary consideration when selecting a probe for a specific application. When the sensor’s electric field is focused by guarding, it creates a field that is a projection of the sensor size and shape. The minimum target diameter for standard calibration is 30% of the diameter of the sensing area. The further the probe is from the target, the larger the minimum target size
  • 6. Range of Measurement The range in which a capacitive sensor is useful is a function of the area of the sensing surface. The greater the area, the larger the range. The driver electronics are designed for a certain amount of capacitance at the sensor. Therefore, a smaller sensor must be considerably closer to the target to achieve the desired amount of capacitance. The electronics are adjustable during calibration, but there is a limit to the range of adjustment. In general, the maximum gap at which a probe is useful is approximately 40% of the sensing surface diameter. Standard calibrations usually keep the gap considerably less than that. Multiple Channel Sensing Frequently, a target is measured simultaneously by multiple probes. Because the system measures a changing electric field, the excitation voltage for each probe must be synchronized or the probes would interfere with each other. If they were not synchronized, one probe would be trying to increase the electric field while another was trying to decrease it thereby giving a false reading. Driver electronics can be configured as masters or slaves. The master sets the synchronization for the slaves in multiple channel systems. Effects of Target Material The electric field from the probe sensing area is seeking a conductive surface. For this reason, capacitive sensors are not affected by the target material provided that it is a conductor. Because the electric field from the sensor stops at the surface of the conductor, target thickness does not affect the measurement. Surface finish can affect the measurement. Capacitive sensors will measure the average position of the target surface within the spot size of the sensor. Measuring Non-Conductors Nonconductors can be measured by passing the electric field through them to a stationary conductive target behind.
  • 7. Capacitive sensors are most often used to measure the change in position of a conductive target. But capacitive sensors can be very effective in measuring presence, density, thickness, and location of non-conductors as well. Non-conductive materials like plastic have a different dielectric constant than air. The dielectric constant determines how a non-conductive material affects capacitance between two conductors. By inserting a non-conductive material in the gap between the probe and a stationary reference target, the capacitance will change in relationship to the thickness, density, or location of the material. Fringing can be used to measure nonconductive targets without a conductive background target. Sometimes it’s not feasible to have a reference target in front of the probe. If the material has a high dielectric constant and a large sensor is used, measurements can still be made by a technique called fringing. If there is no conductive surface directly in front of the probe, the sensor’s electric field will wrap back to the shell of the probe itself. This is called a fringe field. If a non-conductive material is brought in proximity to the probe, its dielectric will change the fringe field and this can be used to measure the non-conductive material. Strategies for maximizing effectiveness and minimizing error Maximizing Accuracy: Target Size Small targets make measurement accuracy sensitive to small probe position errors. Unless otherwise specified, factory calibrations are done with a flat conductive target that is considerably larger than the sensor area. A system calibrated in this way will give accurate results when measuring a flat target more than 30% larger than the sensing area. If the target area is too small, the electric field will begin to wrap around the sides of the target. In this case, the electric field extends farther than it did in calibration and will measure the target as farther away.
  • 8. This means that the probe must be closer to the target for the same zero point. Because this distance differs from the original calibration, error will be introduced. Error is also created because the probe is no longer measuring a flat surface. An additional problem of an undersized target is that the system becomes sensitive to X and Y location of the probe relative to the target. Without changing the gap, the output will change significantly if the probe is moved left or right because less of the electric field is going to the center of the target and more is going around to the sides. Maximizing Accuracy: Target Shape Curved targets change the shape of the electric field, affecting accuracy. Target shape is also a consideration. Since the capacitive sensors are calibrated to a flat target, measuring a target with a curved surface will cause errors. Because the sensor will measure the average distance to the target, the gap at zero volts will be different than when the system was calibrated. Errors will also be introduced because of the different behavior of the electric field with the curved surface. In cases where a non-flat target must be measured, the system can be factory calibrated to the final target shape. Alternatively, when flat calibrations are used with curved surfaces, multipliers can be provided to correct the measurement value. Maximizing Accuracy: Surface Finish Irregular surface finish can cause different measurements as the target moves parallel to the probe face. When the target surface is not perfectly smooth, the capacitive sensor will average over the area covered by the spot size of the sensor. The measurement value can change as the sensor is moved across the surface due to a change in the average location of the surface. The magnitude of this error depends on the nature and symmetry of the surface irregularities.
  • 9. Maximizing Accuracy: Parallelism During calibration, the surface of the sensor is parallel to the target surface. If the probe or target is tilted any significant amount, the shape of the spot where the field hits the target elongates and changes the interaction of the field between the probe and target. Because of the different behavior of the electric field, measurement errors will be introduced. Parallelism must be considered when designing a fixture for the measurement. Parameters used to determine the quality of the sensor Sensitivity Error Sensitivity Error - The slope of the actual measurements deviates from the ideal slope. A sensor’s sensitivity is set during calibration. When sensitivity deviates from the ideal value this is called sensitivity error, gain error, or scaling error. Since sensitivity is the slope of a line, sensitivity error is usually presented as a percentage of slope; comparing the ideal slope with the actual slope. Offset Error Offset Error - A constant value is added to all measurements. Offset error occurs when a constant value is added to the output voltage of the system. Capacitive sensor systems are usually ―zeroed‖ during setup, eliminating any offset deviations from the original calibration. However, should the offset error change after the system is zeroed, error will be introduced into the measurement. Temperature change is the primary factor in offset error.
  • 10. Linearity Error Linearity Error - Measurement data is not on a straight line. Sensitivity can vary slightly between any two points of data. This variation is called linearity error. The linearity specification is the measurement of how far the output varies from a straight line. To calculate the linearity error, calibration data is compared to the straight line that would best fit the points. This straight reference line is calculated from the calibration data using a technique called least squares fitting. The amount of error at the point on the calibration curve that is furthest away from this ideal line is the linearity error. Linearity error is usually expressed in terms of percent of full scale. If the error at the worst point was 0.001mm and the full scale range of the calibration was 1mm, the linearity error would be 0.1%. Error Band Gap (mm) Expected Value (VDC) Actual Value (VDC) Error Band (mm) 0.50 -10.000 -9.800 -0.010 0.75 -5.000 -4.900 -0.005 1.00 0.000 0.000 0.000 1.25 5.000 5.000 0.000 1.50 10.000 10.100 0.005 Error Band- the worst case deviation of the measured values from the expected values in a calibration chart. In this case, the total error is -0.010mm.
  • 11. Error band accounts for the combination of linearity and sensitivity errors. It is the measurement of the worst case absolute error in the calibrated range. The total error is calculated by comparing the output voltages at specific gaps to their expected value. The worst case error from this comparison is listed as the capacitive sensor system’s total error. High-Performance Capacitive Sensors It is important to distinguish between "high-performance" sensors and inexpensive sensors. Simple capacitive sensors, such as those used in inexpensive proximity switches or elevator touch switches, are simple devices and in their most basic form could be designed in a high school electronics class. Proximity type sensors are tremendously useful in automation applications and many commercially available models are well made, but they are not suited to precision metrology applications. In contrast, capacitive sensors for use in precision displacement measurement and metrology applications use complex electronic designs to execute complex mathematical algorithms. Unlike inexpensive sensors, these high-performance sensors have outputs which are very linear, stable with temperature, and able to resolve incredibly small changes in capacitance resulting in high resolution measurements of less than one nanometer. Advantages Compared to other noncontact sensing technologies such as optical, laser, eddy-current, and inductive, high-performance capacitive sensors have some distinct advantages. Higher resolutions including sub nanometer resolutions Not sensitive to material changes: Capacitive sensors respond equally to all conductors Inexpensive compared to laser interferometers. Capacitive sensors are not a good choice in these conditions: Dirty or wet environment (eddy-current sensors are ideal). Large gap between sensor and target is required (optical and laser are better). Applications Capacitive sensors are useful in any application requiring the measurement or monitoring of the position of a conductive target. Position Measurement/Sensing
  • 12. Capacitive sensors are basically position measuring devices. The outputs always indicate the size of the gap between the sensor's sensing surface and the target. When the probe is stationary, any changes in the output are directly interpreted as changes in position of the target. This is useful in: Automation requiring precise location Semiconductor processing Final assembly of precision equipment such as disk drives Precision stage positioning Dynamic Motion Measuring the dynamics of a continuously moving target, such as a rotating spindle or vibrating element, requires some form of noncontact measurement. Capacitive sensors are ideal when the environment is clean and the motions are small, requiring high-resolution. Disk drive spindles High-speed drill spindles Ultrasonic welders Vibration measurements Thickness Measurement Measuring material thickness in a noncontact fashion is a common application for capacitive sensors. The most useful application is a two- channel differential system in which a separate sensor is used for each side of the piece being measured. Details on thickness measurements with capacitive sensors are available in the Conductive Material Thickness Measurement with Capacitive Sensors Application Note. Capacitive sensor technology is used for thickness measurement in these applications: Silicon wafer thickness Brake rotor thickness
  • 13. Disk drive platter thickness Nonconductive Thickness Capacitive sensors are sensitive to nonconductive materials which are placed between the probe's sensing area and a grounded back target. If the gap between the sensor and the back target is stable, changes in the sensor output are indicative of changes in thickness, density, or composition of the material in the gap. This is used for measurements in these applications: Label positioning during application Label counting Glue detection Glue thickness Assembly testing Assembly testing Capacitive sensors have a much higher sensitivity to conductors than to nonconductors. For this reason, they can be used to detect the presence/absence of metallic subassemblies in completed assemblies. An example is a connector assembly requiring an internal metallic snap ring which is not visible in the final assembly. Online capacitive sensing can detect the defective part and signal the system to remove it from the line. Capacitive Sensing in HID Capacitance sensors detect a change in capacitance when something or someone approaches or touches the sensor. Capacitive sensing as a human interface device (HID) technology, for example to replace the computer mouse, is becoming increasingly popular. Capacitive sensors are used in devices such as laptop track-pads, MP3 players, computer monitors, cell phones and others. More and more engineers choose capacitive sensors for their flexibility, unique human-
  • 14. device interface and cost reduction over mechanical switches. Capacitive touch sensors have become a predominant feature in a large number of mobile devices and MP3 players. Capacitive sensors detect anything which is conductive or having dielectric properties. While capacitive sensing applications can replace mechanical buttons with capacitive alternatives, other technologies such as multi-touch and gesture-based touchscreens are also premised on capacitive sensing. Working Principle A basic sensor includes a receiver and a transmitter, each of which consists of metal traces formed on layers of a printed-circuit board (PCB). As shown in Figure 1, the AD714x has an on- chip excitation source, which is connected to the transmitter trace of the sensor. Between the receiver and the transmitter trace, an electric field is formed. Most of the field is concentrated between the two layers of the sensor PCB. However, a fringe electric field extends from the transmitter, out of the PCB, and terminates back at the receiver. The field strength at the receiver is measured by the on-chip sigma-delta capacitance-to-digital converter. The electrical environment changes when a human hand invades the fringe field, with a portion of the electric field being shunted to ground instead of terminating at the receiver. The resultant decrease in capacitance—on the order of femtofarads as compared to picofarads for the bulk of the electric field—is detected by the converter. In general, there are three parts to the capacitance-sensing solutions:
  • 15. The driver IC, which provides the excitation, the capacitance-to-digital converter, and compensation circuitry to ensure accurate results in all environments. The sensor—a PCB with a pattern of traces, such as buttons, scroll bars, scroll wheels, or some combination. The traces can be copper, carbon, or silver, while the PCB can be FR4, flex, PET, or ITO. Software on the host microcontroller to implement the serial interface and the device setup, as well as the interrupt service routine. For high-resolution sensors such as scroll bars and wheels, the host runs a software algorithm to achieve high resolution output. No software is required for buttons. AD714x Driver ICs These capacitance-to-digital converters are designed specifically for capacitance sensing in human-interface applications. The core of the devices is a 16-bit sigma-delta capacitance-to- digital converter (CDC), which converts the capacitive input signals (routed by a switch matrix) into digital values. The result of the conversion is stored in on-chip registers. The on-chip excitation source is a 250-kHz square wave.
  • 16. These devices interface with up to 14 external capacitance sensors, arranged as buttons, bars, wheels, or a combination of sensor types. The external sensors consist of electrodes on a 2- or 4- layer PCB that interfaces directly with the IC. The devices can be set up to interface with any set of input sensors by programming the on-chip registers. The registers can also be programmed to control features such as averaging and offset adjustment for each of the external sensors. An on-chip sequencer controls how each of the capacitance inputs is polled. The AD714x also include on-chip digital logic and 528 words of RAM that are used for environmental compensation. Humidity, temperature, and other environmental factors can affect the operation of capacitance sensors; so, transparently to the user, the devices perform continuous calibration to compensate for these effects, giving error-free results at all times. One of the key features of the AD714x is sensitivity control, which imparts a different sensitivity setting to each sensor, controlling how soft or hard the user’s touch must be to activate the sensor. These independent settings for activation thresholds, which determine when a sensor is active, are vital when considering the operation of different-size sensors. Take, for example, an application that has a large, 10-mm-diameter button, and a small, 5-mm-diameter button. The user expects both to activate with same touch pressure, but capacitance is related to sensor area, so a smaller sensor needs a harder touch to activate it. The end user should not have to press one button harder than another for the same effect, so having independent sensitivity settings for each sensor solves this problem. Different Shapes & Sizes in capacitance sensing As noted earlier, the sensor traces can be any number of different shapes and sizes. Buttons, wheels, scroll-bar, joypad, and touchpad shapes can be laid out as traces on the sensor PCB. Figure below shows a selection of capacitance sensor layouts. Button
  • 18. Many options for implementing the user interface are available to the designer, ranging from simply replacing mechanical buttons with capacitive button sensors to eliminating buttons by using a joypad with eight output positions, or a scroll wheel that gives 128 output positions. The number of sensors that can be implemented using a single device depends on the type of sensors required. The AD7142 has 14 capacitance input pins and 12 conversion channels. The AD7143 has eight capacitance inputs and eight conversion channels. The table below shows the number of input pins and conversion stages required for each sensor type. Any number of sensors can be combined, up to the limit established by the number of available inputs and channels. Sensor Type Number of CIN inputs required Number of conversion channels required Button 1 1 (0.5 for differential operation) 8-Way Switch 4—top, bottom, left, and right 3 Slider 8—1 per segment 8—1 per segment Wheel 8—1 per segment 8—1 per segment Keypad Touchpad 1 per row, 1 per column 1 per row, 1 per column Measurements are taken on all connected sensors sequentially—in a ―round-robin‖ fashion. All sensors can be measured within 36 ms, though, allowing essentially simultaneous detection of each sensor’s status—as it would take a very fast user to activate or deactivate a sensor within 40 ms. Advantages Capacitance sensors are more reliable than mechanical sensors—for a number of reasons. There are no moving parts, so there is no wear and tear on the sensor, which is protected by covering material, for example, the plastic cover of an MP3 player. Humans are never in direct contact with the sensor, so it can be sealed away from dirt or spillages. This makes capacitance sensors especially suitable for devices that need to be cleaned regularly—as the sensor will not be damaged by harsh abrasive cleaning agents—and for hand-held devices, where the likelihood of accidental spillages (e.g., coffee) is not negligible.
  • 19. Conclusion Capacitance sensors are an emerging technology for human-machine interfaces and are rapidly becoming the preferred technology over a range of different products and devices. Capacitance sensors enable innovative yet easy-to-use interfaces for a wide range of portable and consumer products. Easy to design, they use standard PCB manufacturing techniques and are more reliable than mechanical switches. They give the industrial designer freedom to focus on styling, knowing that capacitance sensors can be relied upon to give a high-performance interface that will fit the design. References: • http://www.analog.com/library/analogdialogue/ • http://www.lionprecision.com/tech-library/ • http://electronicdesign.com/Articles/ • http://www.sensorsmag.com/sensors • http://en.wikipedia.org