Prysmian Draka supplies a complete range of marine, offshore oil and gas power, control and instrumentation cables for use on oil platforms and floating oil production units (FPSO). T&D distribute an extensive range of cables from 250V to 33kV - a complete range of marine, offshore oil and gas industry cables to IEEE, UKOOA and IEC specification.
The T&D and Prysmian commercial relationshipgoes back to the previous century. T&D have distributed the Prysmian Components range of cable joints, cable glands, cable cleats and high voltage cable terminations for several decades. The new relationship will now extend T&D's portfolio to embrace Prysmian Draka Offshore Marine, Oil & Gas cables.
Prysmian Draka Marine Offshore Oil & Gas Cables - Overview
RFOU(i) 250V S1/S5 Halogen-free, mud resistant instrumentation cable
RFOU(c)250V S2/S6 Halogen-free, mud resistant instrumentation cable
BFOU(i)250V S3/S7 Halogen-free, mud and fire resistant instrumentation cable
BFOU(c)250V S4/S8 Halogen-free, mud and fire resistant instrumentation cable
RU(i) 250V S11 Halogen-free, unarmoured, mud resistant instrumentation cable
BU(i) 250V S13 Halogen-free, unarmoured, mud resistant instrumentation cable
BU(c) 250V S14 Halogen-free, unarmoured, mud resistant instrumentation cable
RFOU 0,6/1kV P1/P8 Halogen-free, mud resistant power cable
RFOU 6/10(12)kV P3/P10 Halogen-free, mud resistant HV power cable
RFOU 12/20(24)kVP19/P21 Halogen-free, mud resistant HV power cable
BFOU 0,6/1kV P5/P12 Halogen-free, mud resistant, fire resistant power cable
UX 1000V P15 Halogen-free, mud resistant insulated conductor
RU 0,6/1kV P18 Halogen-free, unarmoured, mud resistant power cable
BU 0,6/1kV P17 Halogen-free, fire resistant, unarmoured, mud resistant power cable
QFCI Fire resistant optical fibre cable, halogen-free
AICI Optical cable for industrial environments
IFLI 250V P16 Cables for living quarter and office areas, halogen-free
2. CONTENTS
1Bostmarine Type LSX Power Cable Four Conductor .............................................................................................
3Bostmarine Type LSX Power Cable Multi-Conductor ............................................................................................
5Bostmarine Type LSX Power Cable Three Conductor ...........................................................................................
7Bostmarine Type LSX Power Cable Two Conductor .............................................................................................
9Bostmarine Type LSX Signal Cable 16 AWG ........................................................................................................
11Bostmarine Type LSX Signal Cable 18 AWG ........................................................................................................
13Bostmarine Type LSX Signal Cable 20 AWG ........................................................................................................
15Bostmarine Type T/N Control Cable Multi-Conductor ............................................................................................
17Bostmarine Type T/N Control Cable Multi-Conductor Shielded .............................................................................
19Bostmarine Type T/N Control Cable Shielded Triads ............................................................................................
21Bostmarine Type T/N Power Cable Four Conductor ..............................................................................................
23Bostmarine Type T/N Power Cable Three Conductor ............................................................................................
25Bostmarine Type T/N Power Cable Two Conductor ..............................................................................................
27Bostmarine Type T/N Signal Cable 14 AWG .........................................................................................................
29Bostmarine Type T/N Signal Cable 16 AWG .........................................................................................................
31Bostmarine Type T/N Signal Cable 18 AWG .........................................................................................................
33Bostmarine Type T/N Signal Cable 20 AWG .........................................................................................................
35Bostmarine Type X Control Cable ..........................................................................................................................
37Bostmarine Type X Power Cable Four Conductor .................................................................................................
39Bostmarine Type X Power Cable Three Conductor ...............................................................................................
41Bostmarine Type X Power Cable Two Conductor ..................................................................................................
43Bostmarine Type X Signal Cable 16 AWG .............................................................................................................
45Bostmarine Type X Signal Cable 18 AWG .............................................................................................................
47Bostmarine Type X Signal Cable 20 AWG .............................................................................................................
49Bostrig 125 Type P Control 10&12AWG ................................................................................................................
51Bostrig 125 Type P Control 12&10AWG ................................................................................................................
53Bostrig 125 Type P Control 14AWG ......................................................................................................................
55Bostrig 125 Type P Control 14AWG AS .................................................................................................................
57Bostrig 125 Type P Control 16AWG ......................................................................................................................
II
3. CONTENTS
59Bostrig 125 Type P Control 16AWG AS .................................................................................................................
61Bostrig 125 Type P Control 18AWG ......................................................................................................................
63Bostrig 125 Type P Control 18AWG AS .................................................................................................................
65Bostrig 125 Type P MR Power Cable ....................................................................................................................
67Bostrig 125 Type P Power 1C ............................................................................................................................
69Bostrig 125 Type P Power 1C AS ..........................................................................................................................
71Bostrig 125 Type P Power 2C ............................................................................................................................
73Bostrig 125 Type P Power 2C AS ..........................................................................................................................
75Bostrig 125 Type P Power 3C ............................................................................................................................
77Bostrig 125 Type P Power 3C AS ..........................................................................................................................
79Bostrig 125 Type P Power 4C ............................................................................................................................
81Bostrig 125 Type P Power 4C AS ..........................................................................................................................
83Bostrig 125 Type P Power 5C ............................................................................................................................
85Bostrig 125 Type P Power 5C AS ..........................................................................................................................
87Bostrig 125 Type P Signal Cable ...........................................................................................................................
89Bostrig 125 Type P Signal Cable ...........................................................................................................................
91Bostrig 125 Type P Signal IO P 16&14AWG .........................................................................................................
93Bostrig 125 Type P Signal IO P 16&14AWG AS ....................................................................................................
95Bostrig 125 Type P Signal IO P 20&18AWG .........................................................................................................
97Bostrig 125 Type P Signal IO P 20&18AWG AS ....................................................................................................
99Bostrig 125 Type P Signal IO T 18&16AWG ..........................................................................................................
101Bostrig 125 Type P Signal IO T 18&16AWG AS ....................................................................................................
103Bostrig 125 Type P VFD 2kV ............................................................................................................................
105Bostrig MHV-15 Cable IEC 12/20 kV .....................................................................................................................
106Bostrig MHV-15 Cable IEC 8.7/15 kV ....................................................................................................................
107Bostrig MHV-15B Cable 100% Level .....................................................................................................................
108Bostrig MHV-15B Cable 133% Level .....................................................................................................................
109Bostrig MHV-15BS Cable IEC 12/20 kV ................................................................................................................
110Bostrig MHV-15BS Cable IEC 8.7/15 kV ...............................................................................................................
III
8. BOSTMARINE TYPE LSX POWER CABLE
four conductor / LSZH / unarmored & armored
14 AWG to 500 MCM / 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90°C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
FEATURES
• IEEE STANDARD 45 (1998)
• IEEE STANDARD 1580 (2001)
• UL 1309/CSA 245 (1995) FIRST EDITION
CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness as
shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.
RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.
APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to Draka Cableteq USA Specifying Standard J-502
DUSA_LSX05_1005
CustRef LSX-05
2
1
3
Draka Marine Shipboard Cables
DRAKAMOGBOSTMARINE
1
10. BOSTMARINE TYPE LSX CONTROL CABLE
multi-conductor / LSZH / unarmored & armored
18, 16 and 14 AWG / 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smOke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90°C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
FEATURES
• IEEE STANDARD 45 (1998)
• IEEE STANDARD 1580 (2001)
• UL 1309/CSA 245 (1995) FIRST EDITION
CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness as
shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.
RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.
APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to Draka Cableteq USA Specifying Standard J-502
DUSA_LSX07_1005
CustRef LSX-07
2
1
3
Draka Marine Shipboard Cables
DRAKAMOGBOSTMARINE
3
12. BOSTMARINE TYPE LSX POWER CABLE
three conductor / LSZH / unarmored & armored
14 AWG to 1000 MCM / 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90°C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
FEATURES
• IEEE STANDARD 45 (1998)
• IEEE STANDARD 1580 (2001)
• UL 1309/CSA 245 (1995) FIRST EDITION
CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness as
shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.
RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.
APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to Draka Cableteq USA Specifying Standard J-502
DUSA_LSX03_1005
CustRef LSX-03
2
1
3
Draka Marine Shipboard Cables
DRAKAMOGBOSTMARINE
5
14. BOSTMARINE TYPE LSX POWER CABLE
two conductor / LSZH / unarmored & armored
14 AWG to 1000 MCM / 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90°C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
FEATURES
• IEEE STANDARD 45 (1998)
• IEEE STANDARD 1580 (2001)
• UL 1309/CSA 245 (1995) FIRST EDITION
CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-500. Thickness as
shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.
RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.
APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to Draka Cableteq USA Specifying Standard J-500
DUSA_LSX01_1005
CustRef LSX-01
2
1
3
Draka Marine Shipboard Cables
DRAKAMOGBOSTMARINE
7
16. BOSTMARINE TYPE LSX SIGNAL CABLE
indiv. and overall STP / LSZH / unarmored & armored
16 AWG • 1.31 mm2
/ 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90°C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
FEATURES
• IEEE STANDARD 45 (1998)
• IEEE STANDARD 1580 (2001)
• UL 1309/CSA 245 (1995) FIRST EDITION
CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness as
shown in tables on the reverse.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.
RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.
APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to Draka Cableteq USA Specifying Standard J-512
DUSA_LSX13_1005
CustRef LSX-13
2
1
4
3
Draka Marine Shipboard Cables
DRAKAMOGBOSTMARINE
9
18. BOSTMARINE TYPE LSX SIGNAL CABLE
indiv. and overall STP signal / LSZH / unarmored & armored
18 AWG • 0.82 mm2
/ 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90°C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
FEATURES
• IEEE STANDARD 45 (1998)
• IEEE STANDARD 1580 (2001)
• UL 1309/CSA 245 (1995) FIRST EDITION
CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness as
shown in tables on the reverse.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.
RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.
APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to BIW Specifying Standard J512
DUSA_LSX11_0905
CustRef LSX-11
2
1
4
3
Draka Marine Shipboard Cables
DRAKAMOGBOSTMARINE
11
20. BOSTMARINE TYPE LSX SIGNAL CABLE
indiv. and overall STP signal / LSZH / unarmored & armored
20 AWG • 0.52 mm2
/ 300V
APPLICATIONS
BOSTMARINE Type LSX 300 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90°C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 300
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
FEATURES
• IEEE STANDARD 45 (1998)
• IEEE STANDARD 1580 (2001)
• UL 1309/CSA 245 (1995) FIRST EDITION
CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness as
shown in tables on the reverse.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.
RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.
APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to BIW Specifying Standard J512
DUSA_LSX09_1005
CustRef LSX-09
2
1
4
3
Draka Marine Shipboard Cables
DRAKAMOGBOSTMARINE
13
22. BOSTMARINE TYPE T/N CONTROL CABLE
multi-conductor / unarmored & armored
18, 16 and 14 AWG / 600V
APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
FEATURES
• IEEE STANDARD 45 (1998)
• IEEE STANDARD 1580 (2001)
• UL 1309/CSA 245 (1995) FIRST EDITION
CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.
3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.
RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.
APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-500
DUSA_TN07_0905
CustRef TN-07
2
1
3
Draka Marine Shipboard Cables
DRAKAMOGBOSTMARINE
15
24. BOSTMARINE TYPE T/N CONTROL CABLE
multi-conductor shielded / unarmored & armored
16 and 14 AWG / 600V
APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
FEATURES
• IEEE STANDARD 45 (1998)
• IEEE STANDARD 1580 (2001)
• UL 1309/CSA 245 (1995) FIRST EDITION
CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.
3. SHIELD
An aluminum/polyester tape with drain wire, 100% coverage, is applied over the
cabled core.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.
RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.
APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-500
DUSA_TN19_0905
CustRef TN-19
2
3
1
4
Draka Marine Shipboard Cables
DRAKAMOGBOSTMARINE
17
26. BOSTMARINE TYPE T/N CONTROL CABLE
indiv. & overall shielded triads / unarmored & armored
18, 16 and 14 AWG / 600V
APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
FEATURES
• IEEE STANDARD 45 (1998)
• IEEE STANDARD 1580 (2001)
• UL 1309/CSA 245 (1995) FIRST EDITION
CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.
3. TRIAD SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.
RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.
APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-510
DUSA_TN17_1005
CustRef TN-17
2
1
4
3
Draka Marine Shipboard Cables
ISO9001
QSC3497
DRAKA-USA
DRAKAMOGBOSTMARINE
19
27. BOSTMARINE TYPE T/N CONTROL CABLE
indiv. & overall shielded twisted triad / unarmored & armored
18, 16 and 14 AWG / 600V
18 AWG • 1.0 mm2
Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* triads Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km
TT18(IS-OS)T/NT-1 350370 1 7/15.2 0.019 • 0.48 0.045 • 1.14 0.31 • 7.9 56 • 83 0.37 • 9.4 75 • 112 119 • 177
TT18(IS-OS)T/NT-3 350371 3 7/15.2 0.019 • 0.48 0.060 • 1.52 0.59 • 15.0 174 • 259 0.65 • 16.5 209 • 311 291 • 433
TT18(IS-OS)T/NT-6 350372 6 7/15.2 0.019 • 0.48 0.060 • 1.52 0.76 • 19.3 294 • 437 0.82 • 20.8 339 • 504 444 • 661
TT18(IS-OS)T/NT-12350373 12 7/15.2 0.019 • 0.48 0.080 • 2.03 1.05 • 26.7 567 • 844 1.11 • 28.2 629 • 936 772 • 1149
16 AWG • 1.3 mm2
Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* triads Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km
TT16(IS-OS)T/NT-1 350366 1 7/19.2 0.019 • 0.48 0.045 • 1.14 0.33 • 8.4 70 • 104 0.39 • 9.9 91 • 135 138 • 205
TT16(IS-OS)T/NT-3 350367 3 7/19.2 0.019 • 0.48 0.060 • 1.52 0.64 • 16.3 222 • 330 0.70 • 17.8 260 • 387 349 • 519
TT16(IS-OS)T/NT-6 350368 6 7/19.2 0.019 • 0.48 0.060 • 1.52 0.84 • 21.3 380 • 565 0.90 • 22.9 430 • 640 555 • 826
TT16(IS-OS)T/NT-12350369 12 7/19.2 0.019 • 0.48 0.080 • 2.03 1.15 • 29.2 683 • 1016 1.21 • 30.7 751 • 1117 907 • 1350
14 AWG • 2.1 mm2
Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* triads Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km
TT14(IS-OS)T/NT-1 350362 1 7/24.2 0.019 • 0.48 0.045 • 1.14 0.36 • 9.1 93 • 138 0.42 • 10.7 115 • 171 166 • 247
TT14(IS-OS)T/NT-3 350363 3 7/24.2 0.019 • 0.48 0.060 • 1.52 0.70 • 17.8 294 • 437 0.76 • 19.3 336 • 500 431 • 641
TT14(IS-OS)T/NT-6 350364 6 7/24.2 0.019 • 0.48 0.060 • 1.52 0.96 • 24.4 558 • 830 1.02 • 25.9 614 • 914 745 • 1109
TT14(IS-OS)T/NT-12350365 12 7/24.2 0.019 • 0.48 0.080 • 2.03 1.26 • 32.0 1007 • 1498 1.32 • 33.5 1081 • 1609 1251 • 1861
*NOTE: For aluminum armored versions, add an A (ex. 350356A). For bronze armored versions, add a B (ex. 350356B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.
CustRef TN-18
Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com
20
28. BOSTMARINE TYPE T/N POWER CABLE
four conductor power distribution / unarmored & armored
14 AWG to 750 MCM / 600V
APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
FEATURES
• IEEE STANDARD 45 (1998)
• IEEE STANDARD 1580 (2001)
• UL 1309/CSA 245 (1995) FIRST EDITION
CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated Vw1.
3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.
RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.
APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-500
DUSA_TN05_0905
CustRef TN-05
2
1
3
Draka Marine Shipboard Cables
DRAKAMOGBOSTMARINE
21